| 1 | L1₹19.2 LAccepted-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹22.0 L+₹2.5 L (12.8%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹22.6 L+₹3.1 L (15.9%)Rejected-Finance M S GMR CO 151 2 MAHENDRA NILAYAM 11TH MAIN 2ND CROSS BEHIND SRI RAMA TEMPLE KAMMAGONDANAHALLI JALAHALLI WEST BANGALORE 560 015 | BENGALURU URBAN | KARNATAKA | 560015 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹23.3 L+₹3.8 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹58,500
Closing Date
16 Jan 2023, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
8737SPECIAL REPAIRS TO ELECTRICAL INFRASTRUCTURE AT 2AFDC BLDG AND IMMOLS SERVER ROOM JALAHALLI EAST UNDER GE M AF STATION JALAHALLI BANGALORE
2022_MES_570356_1
8737/E8
Open Tender
Electrical and Maintenance Works
Item Rate
122 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT PUBLIC FUND ACCOUNT
₹58,500
25 Feb 2023
20 Dec 2022
18 Jan 2023
20 Dec 2022
16 Jan 2023
3 Jan 2023
20 Dec 2022 - 27 Dec 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified.
Material and labour for point wiring for one Light point using approved colour code as per IS (Red, Black and Green for single phase circuits) with multistrand copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked with valid CM/L No. drawn in Conduit pipe 20mm PVC rigid non metalic conduit, including mild steel Modular sunken box including inner/outer sheet/cover plate and fixed covered etc including PVC insulated multi-stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continiuty conductor to common earth and connecting to earth dolly complete for one light/fan point controlled by one 5/6 amps one way switch. (Note: switch,socket , and fan regulator item to be measured and paid seperatly)
All as per item No here -in- before but for One Exhaust Fan point with Cable 1.5 Sqmm Size complete all as specified and directed.
All as per item No here -in- before but for one celing/wall mounted fan point with Cable 1.5 Sqmm Size complete all as specified and directed.
All as per item No here -in- before but for One Light point for building security light with Cable 1.5 Sqmm Size complete all as specified and directed.
All as per item No here -in- before but for One point for 3 pin modular socket outlet 5/6 Amps 2-in-1, on independent board.
All as per item No here -in- before but for One point for 3 pin modular socket outlet 5/6 Amps 2-in-1, on the same board with other switch.
All as per item no 2 herein before but for above but one point for 5/6 pin modular socket outlet 15/16 Amps 2-in-1, independent board with cable 4sq mm size.
All as per item No 2 herein before but for one point for 5/6 pin modular socket outlet 15/16 Amps 2-in-1, Same board with cable 2.5 sq mm size and other switch.
All as per item No 2 here -in- before but for One bell point controlled by one bell push on independent board.
All as per item No-2 here in before but for One Light point for controlled by two 2-way switches , with cables 1.5 sq. mm size.
All as per item No-2 here-in-before but for One 3 pin modular socket combination 15/16 Amps Independent board for AC point/power equipment with cable 4 Sq mm size complete all as specified.
Supply and fixing Modular Switch 1 way 6 A, 1 Module all as specified and directed.
Supply and fixing Modular Switch 1 way 16 A, 1 Module all as specified and directed.
Supply and fixing Modular bell push 6 A, 1 Module all as specified and directed.
Supply and fixing Modular socket 6 A, - 2/3 pin combined 2 module all as specified and directed.
Supply and fixing Modular socket 6/16 A, - 2 / 3 pin comb 2 module all as specified and directed.
Supply and fixing Modular fan regulator 120W, 2 Module for C/F complete all as specified and directed.
Supply and fixing Bell Ding-Dong AC 230 V AC complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 3 terminals 65x50mm complete all as specified and directed.
Supply and fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with Ledz inverter Lamp 9 watts with suitable back plate angle type complete all as specified and directed. Make : Bajaj / Anchor / panasonic
Supply and fixing LED light fitting,4 feet ,1x20 watt 230 Volt, PC body. Compact appearance, simple and versatile in nature makes it as long lasting, efficient solution for offices and other commercial spaces. Efficacy : 100 lumen/watt with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting .
Supply and fixing LED light fitting, 2 feet ,1x10 watt 230 Volt, PC body. Compact appearance, simple and versatile in nature makes it as long lasting, efficient solution for offices and other commercial spaces. Efficacy : 100 lumen/watt with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting .
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 4 sq mm drawn through and including 20MM size of non-metallic PVC rigid conduit with 4 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 6 sq mm drawn through and including 20MM size of non-metallic PVC rigid conduit with 6 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 10 sq mm drawn through and including 20MM size of non-metallic PVC rigid conduit with 10 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Supply and Fixing surface mounted 36 Watt LED Surface full lit luminaire with glare free uniform illumination with longer life and less maintenance 36 wattages in 2 ft x 2 ft (>100 Lumen/Watt) and electric connection complete all as specified and directed.
Supply and Fixing Recess mounted 36 Watt LED Surface full lit luminaire with glare free uniform illumination with longer life and less maintenance 36 wattages in 2 ft x 2 ft (>100 Lumen/Watt) and electric connection complete all as specified and directed.
Supply&Fixing Ceiling fan 1200 mm sweep 240 volt with blade white colour and electric connection complete all as per site requirement and including taking down old u/s fan complete all as specified and directed by Engr-in-Charge.
Supply & Fixing New Wall mounting fan 400 mm sweep High speed 240 volt copper motor and electric connection complete all as per site requirement and including taking down old u/s fan complete all as specified and directed by Engr-in-Charge.
Supply & Fixing New Exhaust fan Metal Body Heavy duty 300mm high speed 1400RPM with blade Net & Louver and electric connection all as per site requirement and including taking down old u/s fan complete all as specified and directed by Engr-in-Charge.
Supply & Fixing New Exhaust fan Metal Body Heavy duty 450mm sweep with blade Net & Louver and electric connection all as per site requirement and including taking down old u/s fan complete all as per specified and directed by Engr-in-Charge.
Taking down old unserviceable MCB, MCCBs any capacity and size including making good the disturbed area complete as directed
Supply and fixing MCCB 125 Amps 16 KA, Four Pole 415 volts, 50 HZ complete all as specified and as directed.
Supply and fixing MCBTPN/FP 40 to 100 AMP 10 KA, Triple pole 415 volts, 50 HZ complete all as specified and as directed.
Supply and fixing 32 amp MCB SPN rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity 32 amps, in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing MCB SP 5 to 32 AMP 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection, testing and commissioning complete all as specified and as directed.
Taking down old unserviceable main VTPN DBs/MCB DBs any capacity and size including making good the disturbed area complete as directed.
Supply & Fixing Single pole and neutral enclosure with a two pin and earth plug & socket Modular type with one sigle pole MCB 20 Amps, fixed for AC/ other Equipment on wall and making all connections all as directed.
Supply and fixing MCB DB(distibution board) 8 Way SPN(single pole and neutral) single phase made sheet steel cement spill protector , isolated neutral bar, IP:54 protection door earthing Mechanical impect strength IK 09, 240 volts and connection complete all as specified.
Supply and fixing TPN MCB DB(distibution board) Double Door 12 Way, TPN (triple pole neutra) IP:54 protection, isolated neutral bar, Mechanical impect strength three phase, cement spill protector, 415 volts and connection complete all as specified and as directed.
Supply and fixing in repair VTPN MCCB DB(distibution board) 125A Double Door 8 Way, IP:54 protection, isolated neutral bar, Mechanical impect strength IK 09 three phase, cement spill protector, 415 volts including one new mccb 125A 4pole 16kA and fixing at site,electric connection complete all as specified and as directed.
Supply and fixing in repair VTPN MCCB DB(distibution board) 250A Double Door 12Way, IP:54 protection, isolated neutral bar, Mechanical impect strength IK 09 three phase, cement spill protector, 415 volts, including one new mccb 250A 4pole 25kA fixing at site and electric connection complete all as specified and as directed.
Supply and fixing LED Building security light fitting 60 watts with cast aluminium housing, toughened glass diffuser, IP 65 and wired including all accessories , suitable size GI bracket made with light grade pipe & clamps-02 Nos with bolts & nuts. and fixed at site and eletric connection complete all specified and as directed.
Material and labour for New Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified including excavation earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe testing on completion including taking down old earthing material complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level complete all as specified and directed by Engr-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-charge.
Removing surplus exacavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed by Engr-in-charge.
Spreading riddled soil in trenches as cable cushionng all as per IS 1255-1983 as directed.Note:- Excavated approved soil shall be riddled by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8cm and 15cm after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable(ii) For the purpose of measurement punned thickness will be considered for payment.
Material and labour for well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as speified and directed by Engr-in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½ core UG cable runinng on wall / floor/dcut) including taking down old U/S UG cable.
Material and labour for earthing complete with copper earth plate electrode 60x60cmx3.15mm buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top dege of the plate not less than 1.5 meters below normal ground level, connected to 20X3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in elctrical plate No 3 connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe but all as specified and directed by Engineer-in-Charge. all as specified including testing on completion and taking down old earthing material.
Material and labour for detailed study and recommendation for carrying out Soil Resistivity Test in 4 (Four) Directions at various location within the 25 mtr radius complete all as specified in following general condition including misc works required for the soil resistivity test as per IS (Indian electricity rules) requirement. Note - General condition (i) Field Audit Team to be deployed at site duly observing the safety rules as prescribed as per testing regulations. (ii) Safety procedures and any other action / precaution such as health check up to be undertaken by the firm before commencing the work in the area. (iii) The detailed study/analysis and design reports of existing building earthing infrastracture shall be furnish in Auto Cadd formet and also recommend the quantity of earth electrode with connected accessories for required value of earth resistence as per AFO 24/19 and OEM specified values as per following details :- (a) Power Earthing (PS) - Less than 1 Ohm (b) Signal Earthing (SG) - Less than 1 Ohm (c) Equipment Earthing (EQ) - Less than 1 Ohm for AFNET Equipment room and Less than 3 OHM for L-2 Locations (d) Lightning Arrester (LA)- Less than 5 Ohms (e) Labour charge for disconnecting/Connecting of earth strip from / to the earth electrode and required any hardware such as bolts, nuts etc for breaking of concrete or any other civil required to drive the spike / probes during testing shall be includes quoted rates of items. (f) Study of existing building earthing infrastructure at AFS Jalahalli and remedial action to overcome deficiencies in accordance with following standard:- (i) BS -7430 clause 8.5 (ii) Indian standard code of practice for earthing IS : 3043-1987 (reaffirmed 2006) (iii) IS/IEC 62305-3 of 2010 IS: protection against lightning. (iv) IEEE 1100-2205 - IEEE recommended practices for powering and ground electronics equipment. Ohms (v) National building code of India 2016- Volume 2 part- 8 :- Building services section 2 electrical and allied installations. The quoted rates of items included all above including submission report in soft and hard copy in approved manner of Engr in charge
Supply and Fix of comprising of 17.2 mm dia 3 mtr long Earth electrode of low carbon steel electrode with 250 micron copper bonding, 50 pounds of Ecosafe Based environment friendly backfill and suitable clamp, Back-fill earthing enhancing compound should strictly be a Eco Safe Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compund shall not be mixed with any soil while pouring in the bore hole. Test Certificate as per as per IEC : 62561-7 for Back-fill compound shall be submitted along with the material. 17.2 OD SS clamp both side, Eco Friendly rust proof heavy duty weatherproof Polyethylene Earth Pit Chamber with dimensions :254 mm dia (top), 330mm dia (bottom) & 260 mm (height). NOTE : Number of Earth pit Qty will vary with subject to the Soil resistivity Test report.
Material and labour for earthing complete for lightning conductor with Galvanised iron earth plate electrode 60x60cmx6mm buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top dege of the plate not less than 1.5 meters below normal ground level, connected to 20X3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in elctrical plate No 3 connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe but all as specified and directed by Engineer-in-Charge. all as specified including testing on completion and taking down old earthing material.
Taking down existing copper/aluminium/GI strip of any size and making good the disturbed surface all as directed by Engineer-in-Charge.
Supply and fix in replacement copper strip 20 X 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground brazing at each joints between strip including saddle/Ceramic insulator/PCC block where required all as directed by Engineer-in-Charge.
Supply and fixing in replacement of aluminium strip 25x3mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut and bolt, gutties, screws etc all as specified and as directed .
Supply and fixing in replacement of GI strip 32x6mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut and bolt, gutties, screws etc all as specified and as directed .
Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm longhex. head screw all as specified and directed.
Material and labour for sub main wiring with 4 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 10 sqmm drawn through suitable size of non-metallic PVC rigid conduit with 1x10 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, connecting up and taking down old wiring complete all as specified Including taking down old sub main wiring.
Supply and Fixed in repairs MCB single pole 240 volts 5 to 30 Amps 10 KA rupturing capacity 'C' series all as specified and as dircted.
Supply and fixing VTPN 4 way MCCB distribution box, Double door IP : 43 protection, door earthing, Isolated neutral bar, Mechanical Impact Strength IK 08, Insulated bus bar assembly suitable for MCCBs upto 63 Amps, 16 kA, 4 Pole Including taking down old MCB DB's.
Supply and fixing MCCB 16kA 63 Amps 4 pole optium 1.0E (Fixed TM Range) suitable for isolation, fixed Overload & fixed short circuit setting F1.
M/S SRI BALAJI ENTERPRISES
G.M.R.& CO
eurekaenterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .