Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.2 LAccepted-AOC PLOT NO 83 84 DEVELOPED PLOT INDUSTRIAL ESTATE PERUNGUDI CHENNAI TAMILNADU 600096 | CHENNAI | TAMIL NADU | 600096 | ₹21.2 L | 1 | Accepted-AOC Technically approved and lowest bidder |
| Sl No | Description | Qty | Unit | Spincotech Pvt Ltd |
|---|---|---|---|---|
| 1.00Machinery & Equipment | ||||
| 1.01 | HPLC Module Pump(Quaternary Gradient)
•High Precision dual plunger design.
•System designed to work in micro , semi-micro analytical to semi prep scale
•High speed double micro plunger in –parallel pump with automatic pulsation correction mechanism
•Achieving pulse –free solvent delivery
•Forced check valve designed for excellent solvent delivery control
•Flow raterange:0.0001ml to 10.0ml/min each pump
•Flow rate resolution of 3nl/step increment
•Built in self diagnostic, Auto purge function
•Flow precision is less than±0.06% RSD
•Flow rate accuracy:±1%
•Concentration accuracy±0.5%
Washing kit
Gradient mixer,
Reservoir tray
Quaternary Gradient unit
DGU-20A5R BKL Degassing unit
Manual injector: Rheodyne injector with 20 ul loop & mounting plate 25ul Hamilton syringe
PDA Detector
Wavelength 190 – 800 nm, Channel 512, Drift smaller than 0.5x10-3 AU/Hour, Noise smaller than 0.6x10-5 AU. Wavelength accuracy should be ±1 nm, Linearity: 2.0AU or more. A deuterium lamp [D2] and a Tungsten lamp [W] should be available as Light Source
A Conventional HPLC flow cell [12 μL volume, 10 mm cell path length]. Lamp Replacement: Front access, Lamp Life Time : 2000 hours (D2 lamp)
Controller alite system controller, Solvent bottles with cap 5/pkt, Chromatographic software | 1 | Nos | 21,24,000 ₹21,24,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
8 Dec 2025, 5:00 pmClosed
Principal Goa College of Pharmacy
GOA College of Pharmacy
TENDER FOR SUPPLY OF LABORATORY EQUIPMENTS andINSTRUMENTS
2025_GCP_26491_1
20/03/25-26/SP/GCP/01
Open Tender
Laboratory and scientific equipment
Supply
30 days
Goa College of Pharmacy
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
₹1.2 L
16 Jun 2026
20 Nov 2025
9 Dec 2025
20 Nov 2025
8 Dec 2025
21 Nov 2025
21 Nov 2025 - 5 Dec 2025
Machinery & Equipment
HPLC Module Pump(Quaternary Gradient) •High Precision dual plunger design. •System designed to work in micro , semi-micro analytical to semi prep scale •High speed double micro plunger in –parallel pump with automatic pulsation correction mechanism •Achieving pulse –free solvent delivery •Forced check valve designed for excellent solvent delivery control •Flow raterange:0.0001ml to 10.0ml/min each pump •Flow rate resolution of 3nl/step increment •Built in self diagnostic, Auto purge function •Flow precision is less than±0.06% RSD •Flow rate accuracy:±1% •Concentration accuracy±0.5% Washing kit Gradient mixer, Reservoir tray Quaternary Gradient unit DGU-20A5R BKL Degassing unit Manual injector: Rheodyne injector with 20 ul loop & mounting plate 25ul Hamilton syringe PDA Detector Wavelength 190 – 800 nm, Channel 512, Drift smaller than 0.5x10-3 AU/Hour, Noise smaller than 0.6x10-5 AU. Wavelength accuracy should be ±1 nm, Linearity: 2.0AU or more. A deuterium lamp [D2] and a Tungsten lamp [W] should be available as Light Source A Conventional HPLC flow cell [12 μL volume, 10 mm cell path length]. Lamp Replacement: Front access, Lamp Life Time : 2000 hours (D2 lamp) Controller alite system controller, Solvent bottles with cap 5/pkt, Chromatographic software
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.46 MB
BOQ
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .