Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC 1 C NEPAL BHATTACHARJEE STREET KALIGHAT KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.0 L+₹80,499.45 (8.79%)Rejected-Finance 13 11 MOTILAL GUPTA ROAD KOLKATA 700 008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | L2 | Rejected-Finance L2 | |
| 3 | L3₹10.6 L+₹1.5 L (16.2%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical 17 23 K P ROY LANE KOLKATA 700 031 | KOLKATA | KOLKATA | WEST BENGAL | 700031 | - | Rejected-Technical Non submission of shortfall documents |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
18 Jul 2025, 12:00 pmClosed
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor) Writers Buildings, Kolkata 700 001
Temporary EI work for working light of Tableau, security lighting, pandle lighting, CCTV, fan, power plug, split AC etc at both side of Red road IGS in connection with Independence Day Parade 15th august 2025 under MES II PWD.
2025_WBPWD_875537_1
WBPWD/EE-KED/eNIQ-12Q/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Maidan
Please refer Tender documents.
5 documents required · 5 mandatory
₹20,000
O/O The Executive Engineer Kolkata Electrical Divi
14 Aug 2025
8 Jul 2025
21 Jul 2025
8 Jul 2025
18 Jul 2025
14 Jul 2025
14 Jul 2025
Amount
Providing on hire basis following switches on wooden plank board or suitable size angle iron frame incl providing interconnection with socketing earthing attachment etc dismantling at the end of function (with pwd approved materials).( For 10 Days )
415V 200Amp TPNIC Switch with rewireable fuse.
415V 100Amp TPNIC Switch with rewireable fuse.
Providing on hire basis following change over switch etc. on wooden plank board or suitable angle iron frame incl. providing inter connection wiring with socketing earthing attachment etc. and dismantling at the end of function.( with P.W.D. approved materials )( For 7 Days )
440 Volt. 200 Amp. 4 Pole Change over
Providing and installation on hire basis 500 V, 63Amp/32Amp 4 Pole MCB fixed on sheet metal box with proper socketing and dismantling as directed by EIC after the programme (For 2 days)
Providing and installation on hire basis power BDB/TPNMCBDB 440V , 200Amp 4 Pole MCB isolator as incomer with 32Amp or 63 Amp per way(min 6 Way) out going connection, with all arrangement in a outdoor type pillar box incl interconnection with proper socketing and dismantling as direcyted by EIC after the programme (For 10 days)
Providing on hire basis 230V. 6-32A/way,6Way S.P.N.D.B. with 63 Amp.DP Isolator as incomer and 06nos 6-32A SPMCB as outgoing on wooden plank board or suitable angle iron frame incl. providing inter connection wiring with socketing earthing attachment etc. and dismantling at the end of function.( with P.W.D. approved materials.)( For 10 Days )
Providing on hire basis Main Wiring with 1.1 K.V. grade PVC insulated Al or copper armoured Cable of following size including sockleting,glanding & finishing as required incl. laying in trench (at least 230 mm.)below ground. dismantling the same & mending good damages.(For 10 Days)
4C X 50 sq.mm. PVC Copper armoured cable.
4C X 70 sq.mm. PVC Al armoured cable.
4C X 50 sq.mm. PVC Al armoured cable.
4C X 25 sq.mm. PVC Al armoured cable.
Supplying & Drawing by following Single Core of following sizes PVC insulated and unsheathed multi stranded Copper wire on hire basis with carrying cost at the sites and dismantling the same.( For 10 Days )
7/0.036(7/20) single core P.V.C. copper wire
3/0.029(3/20) single core P.V.C. copper wire
4 sqmm cu. Wire
Providing on hire basis PVC modular 5A/15A plug socket complete with necy wiring in 3x 1.5 sqmm single core copper wire and dismantling as directed by EIC after the programme.(Aveg Run-3 Mtr)(For 10 Days)
Providing and Fixing on hire basis following lights complete with all accessories and dismantling as direcyted by EIC after the programme.( For 7 Days )
Single LED Tube 1x 20/18 Watt
20 Watt LED Bulb with holder
9 Watt LED Bulb with holder
Providing and Fixing on hire basis following Flood light fittings complete with all accessories and dismantling as directed by EIC after the programme.( For 10 Days )
Minimum 200 Watt LED Flood fittings.
Providing and Fixing on hire basis following Flood light fittings complete with all accessories and dismantling as directed by EIC after the programme.( For 15 Days )
Minimum 150 Watt LED Flood fittings.
Providing on hire basis 600 mm sweep Air Circulator Fan complete including transportation, loading , unloadingand and dismantling after programme as per direction of EIC.( For 10 Days )
Earthing the installation with proper earthing practices as per direction of EIC. ( For 10 Days )
Temporary lightening arrester arrangement at the top of 20 ft bamboo with 6sqmm Cu wire.( For 10 Days )
Providing on hire basis 440V,3 Ph CPCB approved following Disel Generator Set for prime/standby operation with operation ,maintenance, transportation, appropriate size and length of 4 nos single core copper cables & mobil but without disel as per direction of EIC(Each DG set should have 2 nos body earthing and 2 nos neutral earthing).
125 KVA-1 Set
125 KVA-1 Set
Transportation charges for above Materials from Co's Godown to site & return back to godown after end of function.
Providing and installationon hire basis min 4 TR split type tower AC machine complete with all necy arrangements and dismantling as directed by EIC after the programme.( For 02 Days)
Maintenance, operation & guarding of the above installation by required 3 nos Numbers Skilled and 3 nos Unskilled labour per day round the clock ( 24 Hrs) from the beginning of the installation and upto dismanting time for proper upkeepment and preventing any unwanted incidents like theft,willful damage etc ( no additional charge will be paid for any unwanted incidents)
18 % GST on the total amount from item no 1 to 18.
Supply & refuelling of the DG set as required with all necy charges.
Special Terms and conditions for Temporary E.I. Work - 1) Earthing should conform to IS specification. Earth Continuity wire should not be broken / Jointed. Single Earth continuity wire should be used from Earth Bus-Bar to the installation. 2) All 3ɸ Electrical Panel Should be earthed by two nos. of separate earthing and 1ɸ panel should be earthed by one no earthing. 3) MCB / Rewirable Fuse type Distrubution Board should be installed with proper Trip Current setting / fuse wires. However, MCB type DBs are preferable. 4) No Part of the Electrical Circuit in the pandal / Structure shall be within 12 inches of any decorative cloth / paper. 5) Ordinary Flexible wires should not be used. Only new PVC insulated & sheathed wires (Bearing ISI mark) or PVC insulated wires of FRLS (Fire Resistant Low Smoke) type (ISI Marked) are allowed. 6) All cable ends should be properly sockedted. 7) All joints shall be made with porceline insulated connectors. Twisted & lapped joints shall be avoided. But Joints are strictly not allowed in the dias. 8) Cables / Wires should run along outside the Dias. 9) Ceiling fan (s) / Electrical fittings must not be suspended from the ceiling of Dias. Pedestal fans are not allowed on the Dias. However, Pedestal fans may be installed outside dias, but the body of the fan must be properly earthed.
10) T/L fittings shall be of box type (Indoor commercial type). Any kind of open type fittings must be avoided. 11) Each A.C. Machine should be connected with a separate circuit and earthing should be provided by separate single earth contunuity wire from Earth Bus-bar. 12) P.A. System and Microphone shoud be earthed. 13) Sufficient quantity of Fire Extinguishers and First Aid Box should be provided. 14) If the DGs are not placed at site on time pro rata rate will be reduced from bill. 15) The guarding /security arrangement of all the hired products /installation has to be made by the successful bidder at his/their own cost and responsibility. No additional charge will be paid for any unwanted incidents like theft, damage due to natural calamities or any other reasons whatsoever. 16) During entire hiring period any fault to the hired installation shall be rectified/faulty items replaced, at the cost of agency. Suitable man power for attending and rectification/replacement of damaged items has to be provided by the agency at their own cost. Rectification time is 1 hour for the event day and upto 2hrs for other days. 17) A test certificate cum safety certificate is to be provided by the agency, duly signed by the Supervisor of the agency after completion of installation. 18) A performance guarantee of hired DG sets and AC machines has to be provided by the agency after completion.
S. K. CHATTERJEE ELECTRICALS PVT LTD (BID ID -6738533)
GHANASHYAM ELECTRIC STORES (BID ID -6739448)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .