Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LQualified 2 3 AMIT VIJAY APT CHSL KASTURBA CROSS ROAD NEAR BHANU PARK KANDIVALI WEST MUMBAI 400 067 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | L1 | Qualified MSE, MII, Category: General | |
| 2 | L2₹6.0 L+₹4,200 (0.71%)Qualified B 10 KRISHNA INDUSTRIAL ESTATE OPP B I D C GORWA ESTATE VADODARA 390016 GUJARAT | VADODARA | GUJARAT | 390016 | L2 | Qualified MSE, MII, Category: General | |
| 3 | L3₹8.9 L+₹3.0 L (50.0%)Qualified OFFICE E2 MANALI ARCADE NEAR D MART PADMAVATI PUNE SATARA ROAD PUNE MAHARASHTRA 411009 PUNE MAHARASHTRA 411009 | PUNE | MAHARASHTRA | 411009 | L3 | Qualified MSE, MII, Category: SC | |
| 4 | Disqualified 52 A 4TH FLOOR INDIAN REGISTER OF SHIPPING ADI SHANKARACHARYA MARG POWAI LAKE POWAI MUMBAI MAHARASHTRA | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
29 Apr 2022, 6:00 pmClosed
Structural Audit of GE Panaji Goa
3345836
GEM/2022/B/2126701
Visual Observation Indentify and note the distress damages leakage and take required photographs in
21 days
Goa; North Goa
Total value wise evaluation
BOQ
5 documents required · 5 mandatory
10%
Exempted
29 Apr 2022
22 Apr 2022
29 Apr 2022
| Item No | Item Title | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|
| 1 | Visual Observation Indentify and note the distress damages leakage and take required photographs incl total internal and external data collection of the Bldgs | 6 | Each | Makwana@2018 | 21 |
| 2 | Rebound hammer test to know the surface strength of the concrete | 108 | Each | Makwana@2018 | 21 |
| 3 | Ultra Pulse Velocity test to evaluate the integrity of concrete | 108 | Each | Makwana@2018 | 21 |
| 4 | Carbonation test to identify the depth of carbonation on concrete define the weather effect of concrete | 33 | Each | Makwana@2018 | 21 |
| 5 | Half Cell potential test to define the corrosion potential of RCC sections | 33 | Each | Makwana@2018 | 21 |
| 6 | Chemical analysis to find out the PH value of existing concrete members | 12 | Each | Makwana@2018 | 21 |
| 7 | Chemical Analysis to identify the Chloride content CI of existing concrete members | 12 | Each | Makwana@2018 | 21 |
| 8 | Chemical Analysis to identify the Sulphate contest SO3 of existing concrete members | 12 | Each | Makwana@2018 | 21 |
| 9 | Core cutting and compression testing including reinforcement mapping, cutting of core from existing structural RCC members to find out the equivalent cube compression strength of in-situ concrete | 12 | Each | Makwana@2018 | 21 |
| 10 | Compile NDT report and Analysis data collected to ascertain status of the structure soundness of the building Checking the feasibility and stability of the building | 6 | Each | Makwana@2018 | 21 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3345836.pdf
GEM_BID
panajjisoil_2022-04-22-17-00-28_870a40a751ea058a97d5b77c18196a44.pdf
BOQ
boq_item_sample_file__16__2022-04-08-12-31-09_c8bf9_2022-04-22-17-00-28_28bc964e8e2f6f2ddd6b3ec19d6327b5.csv
BOQ
OTHER
termsCondition.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .