Director, HRI, Prayagraj
HRI, Chhatnag Road Jhunsi, Prayagraj
Annual maintenance contract of intelligent fire alarm system for different places in campus at HRI, Prayagraj
2026_HRI_902802_1
HRI/08/2026
Open Tender
Electrical Works
Works
365 days
HRI, Chhatnag Road, Jhunsi
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹7,400
27 Mar 2026
18 Mar 2026
27 Mar 2026
18 Mar 2026
26 Mar 2026
18 Mar 2026
1st Year - Section-1 (Annual Maintenance contract for intelligent type fire alarm system)
Fire alarm system for Library area (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 55 Nos. 2. Manual call Box : 03 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 03 Nos. 5. Response indicators : 26 Nos.
Fire alarm system for Cluster area (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 12 Nos. 2. Manual call Box : 01 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 04 Nos.
Fire alarm system for Recapp area (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 04 Nos. 2. Manual call Box : 01 No. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 02 Nos.
Fire alarm system for Auditorium (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 08 Nos. 2. Manual call Box : 02 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 Nos. 5. Response indicators : 02 Nos.
Fire alarm system for Computer centre (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 16 Nos. 2. Manual call Box : 03 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 05 Nos.
Fire alarm system for Higgs lecture hall (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 06 Nos. 2. Manual call Box : 01 No. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 01 No.
Fire alarm system for Physics Lab. (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 11 Nos. 2. Manual call Box : 01 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 02 Nos.
Fire alarm system for Engineering building (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 37 Nos. 2. Manual call Box : 02 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 02 No. 5. Response indicators : 22 Nos.
Fire alarm system for Library 1st floor (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 73 Nos. 2. Manual call Box : 04 Nos. 3. Control Panel : 02 No. 4. 24 volt DC Hooter : 03 No. 5. Response indicators : 13 Nos.
Fire alarm system for Institute building (Make: Surksha) having the following equipments. 1. Smoke cum Heat Detector : 155 Nos. 2. Manual call Box : 09 Nos. 3. Control Panel 4 Zone : 01 No. 4. 24 volt DC Hooter : 09 Nos. 5. Response indicators : 82 Nos.
Section-2 - (Mock drill)
Mock Drill for fire safety (Required manpower & Material will be in the scope of work.
Section-3 - (Refilling of Fire Extinguisher as & when required)
Refilling of Fire Extinguisher (Co2) of capacity 2 kg
Refilling of Fire Extinguisher (Co2) of capacity 4.5 kg
Refilling of Fire Extinguisher (Co2) of capacity 6.5 kg
Refilling of Fire Extinguisher (ABC type) of capacity 2.0 kg
2nd Year - Section-1 (Annual Maintenance contract for intelligent type fire alarm system)
Fire alarm system for Library area (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 55 Nos. 2. Manual call Box : 03 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 03 Nos. 5. Response indicators : 26 Nos.
Fire alarm system for Cluster area (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 12 Nos. 2. Manual call Box : 01 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 04 Nos.
Fire alarm system for Recapp area (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 04 Nos. 2. Manual call Box : 01 No. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 02 Nos.
Fire alarm system for Auditorium (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 08 Nos. 2. Manual call Box : 02 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 Nos. 5. Response indicators : 02 Nos.
Fire alarm system for Computer centre (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 16 Nos. 2. Manual call Box : 03 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 05 Nos.
Fire alarm system for Higgs lecture hall (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 06 Nos. 2. Manual call Box : 01 No. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 01 No.
Fire alarm system for Physics Lab. (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 11 Nos. 2. Manual call Box : 01 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 02 Nos.
Fire alarm system for Engineering building (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 37 Nos. 2. Manual call Box : 02 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 02 No. 5. Response indicators : 22 Nos.
Fire alarm system for Library 1st floor (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 73 Nos. 2. Manual call Box : 04 Nos. 3. Control Panel : 02 No. 4. 24 volt DC Hooter : 03 No. 5. Response indicators : 13 Nos.
Fire alarm system for Institute building (Make: Surksha) having the following equipments. 1. Smoke cum Heat Detector : 155 Nos. 2. Manual call Box : 09 Nos. 3. Control Panel 4 Zone : 01 No. 4. 24 volt DC Hooter : 09 Nos. 5. Response indicators : 82 Nos.
Section-2 - (Mock drill)
Mock Drill for fire safety (Required manpower & Material will be in the scope of work.
Section-3 - (Refilling of Fire Extinguisher as & when required)
Refilling of Fire Extinguisher (Co2) of capacity 2 kg
Refilling of Fire Extinguisher (Co2) of capacity 4.5 kg
Refilling of Fire Extinguisher (Co2) of capacity 6.5 kg
Refilling of Fire Extinguisher (ABC type) of capacity 2.0 kg
3rd Year - Section-1 (Annual Maintenance contract for intelligent type fire alarm system)
Fire alarm system for Library area (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 55 Nos. 2. Manual call Box : 03 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 03 Nos. 5. Response indicators : 26 Nos.
Fire alarm system for Cluster area (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 12 Nos. 2. Manual call Box : 01 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 04 Nos.
Fire alarm system for Recapp area (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 04 Nos. 2. Manual call Box : 01 No. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 02 Nos.
Fire alarm system for Auditorium (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 08 Nos. 2. Manual call Box : 02 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 Nos. 5. Response indicators : 02 Nos.
Fire alarm system for Computer centre (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 16 Nos. 2. Manual call Box : 03 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 05 Nos.
Fire alarm system for Higgs lecture hall (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 06 Nos. 2. Manual call Box : 01 No. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 01 No.
Fire alarm system for Physics Lab. (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 11 Nos. 2. Manual call Box : 01 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 01 No. 5. Response indicators : 02 Nos.
Fire alarm system for Engineering building (Make: Agni) having the following equipments. 1. Smoke cum Heater Detector : 37 Nos. 2. Manual call Box : 02 Nos. 3. Control Panel : 01 No. 4. 24 volt DC Hooter : 02 No. 5. Response indicators : 22 Nos.
Fire alarm system for Library 1st floor (Make: Agni) having the following equipments. 1. Smoke cum Heat Detector : 73 Nos. 2. Manual call Box : 04 Nos. 3. Control Panel : 02 No. 4. 24 volt DC Hooter : 03 No. 5. Response indicators : 13 Nos.
Fire alarm system for Institute building (Make: Surksha) having the following equipments. 1. Smoke cum Heat Detector : 155 Nos. 2. Manual call Box : 09 Nos. 3. Control Panel 4 Zone : 01 No. 4. 24 volt DC Hooter : 09 Nos. 5. Response indicators : 82 Nos.
Section-2 - (Mock drill)
Mock Drill for fire safety (Required manpower & Material will be in the scope of work.
Section-3 - (Refilling of Fire Extinguisher as & when required)
Refilling of Fire Extinguisher (Co2) of capacity 2 kg
Refilling of Fire Extinguisher (Co2) of capacity 4.5 kg
Refilling of Fire Extinguisher (Co2) of capacity 6.5 kg
Refilling of Fire Extinguisher (ABC type) of capacity 2.0 kg
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
Tender_document.pdf
Tender Documents • 0.80 MB
BOQ_949014.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .