Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.8 L+₹78,117.50 (6.52%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹13.9 L+₹1.9 L (16.3%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹14.4 L+₹2.5 L (20.5%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹14.7 L+₹2.7 L (22.6%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
8 Jun 2020, 6:00 pmClosed
GE UTILITIES UDHAMPUR
GE UTILITIES UDHAMPUR
Repair/Maintenance and Replacement of LED Street light and accessories in CPH and MPH area under GE Utilities Udhampur
2020_MES_326715_2
GE/U-62/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹39,000
Yes
23 Jul 2020
20 Apr 2020
10 Jun 2020
20 Apr 2020
8 Jun 2020
28 Apr 2020
Amount
Taking down carefully existing unserviceable LED street light fittings of any capacity & size & any make from poles and refixing the same on existing location after making the LED fitting serviceable by replacement of defective drivers with new one complete all as specified and directed by Engr-in-Charge. Note:- (i) Spare parts required for replacement shall be measured and paid separately under relevent items of BOQ. (ii) The cost of Replacement of minor Parts i.e. nuts/bolts,connectors etc are deemed to be included in this item.
S&F in replacement constant current LED driver for energy saving & environment area light fitting > 90 watts security light with active power factor correction (APFC) electronic driver. LED driver 90 watt with operating voltage between 100-270V AC of suitable for existing steel lights of make Surya/C&S/ Crompton/Havells/Bajaj/Syska complete all as specified and directed by Engr-in-Charge.
Description all as per serial Item No 2.00 here-in-before but wattage 60 watt complete all as specified and directed by Engr-in-Charge.
Description all as per serial Item No 2.00 here-in-before but wattage 45 watt complete all as specified and directed by Engr-in-Charge.
S&F in replacement Surge Protection Device (SPD) of capacity 10 KV/5KA for LED energy saving & environment area light of 45-90 watts security light with maximum operating voltage 320V AC, 50 Hz & maximum peak current 10 KA of suitable for existing streel lights of make Surya/C&S/Crompton/Havells/Bajaj/ Syska complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Power Contractor 3 Phase 415 Volts, 40 Amps, coil voltage rating 240 volts including taking down old UNSV power contractor complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Power Contractor 3 Phase 415 Volts, 32 Amps, coil voltage rating 240 volts including taking down old UNSV power contractor complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED street light fixture ≥ 90 Watt LED with pressure die cast aluminium housing with toughened glass having IP-66 degree of protection, individual LED's must have secondary lense for better throw across and along the road, with system luminarie efficacy ≥100 lumen/watt, colour rending index(CRI) of ≥ 70, co-related colour temperature (CCT) of 5700K. Luminaire should have surge protection upto 05 KV and having additional surge protection upto 10 KV for driver, PF ≥ 0.9 and THD ≤10% (Make of LED shall be Cree/Lumileds/Osram/Nichia), operating voltage range from 140 to 270 volt, The potted driver used shall be a constant curent driver with efficiency of ≥ 85%.The manufacturers LOGO shall be engraved into housing of luminaire complete all as specified and directed by Engr-in-Charge. Make: Crompton of model LSTP-90-CDL or technically and commercially equivalent model of SURYA/Havells/SYSKA
S&F in replacement of MCB DP 6-32 Amp, 230V, 50Hz, 10 KA, 'B' series complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SP 6-10 Amp, 230V, 50Hz,10 KA, 'B' series complete all as specified and directed by Engr-in-Charge.
M&L for replacement of old unserviceable rusted GI tubing brackets, 32mm bore, light grade with new GI tubing bracket, 32 mm bore, light grade, 1.20 metre length, made to shape including MS clamp with nuts, bolts and washers etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement moduler box made of FRP / impact resistance plastic & heat resistant materials of suitable size to accomodate the fixtures with IP 65 for controlling of LED security light of any wattages, including provision of MCB SP 6 Amps, connector terminal block 4 pole suitable for fixing cable connection and fixing to pole with suitable size of clamps,nuts,bolts and painting steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
M&L for replacement of old unserviceable cable with PVC insulated 2.5 sqmm, three core tri colour Red for phase, Black for neutral and Green for earth, multi stranded flexible, copper conductor cable from junction box/overhead LT line to street light fitting complete all as specified and directed by Engr-in-Charge.
Taking out UNSV UG cable of any sizes/ capacity complete all as specified and directed by Engr-in-Charge.
M&L for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 16 sq mm ,4 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Description all as per serial Item No 15.00 here-in-before but cross sectional area 16 sqmm, 2 core complete all as specified and directed by Engr-in-Charge.
M&L for painting to steel tubular pole 9 metre long with two coats of aluminium paint including brackets, clamps, nuts bolts, washer etc including making yellow and black strips alternatively (30 cm width each) on pole upto 1.5 metre from the ground level and marking of pole Nos with black paint having back ground yellow as per existing complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, foundations of poles/stays etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge
M&L for sand cushioning to UG cable laid in trenches with clean dry river sand 8 cm below & 15 cm above the cable & punned down to 18 cm thickness complete all as specified and directed by Engr-in-Charge. Note: - For payment purpose 18 cm thickness shall measured.
Brick covering with width equal to the length of the brick as mechanical protection to cable using sub class ‘B’ bricks, laid flat of size 230mmx115mmx75mm complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED lamp 5 Watt complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED lamp 10 Watt complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED lamp 15 Watt complete all as specified and directed by Engr-in-Charge.
Supplying fabricating and fixing in replacement of MS clamps for fixing street light fitting, main switches including MS nuts, bolts and washers complete all as specified and directed by Engr-in-Charge.
M&L in replacement of PVC insulated multi stranded aluminum conductor PVC cable sheathed 10 Sqmm twin core and making connections of street light fittings with overhead lines/UG Cable complete all as specified and directed by Engr-in-Charge. Make: Plaza/ Paragon/ Kalinga.
S&F in replacement of automatic street light control switch of 8 KW single phase using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitabe rating power contractor (s) and Incoming-Outgoing MCBs rating of 40-63 Amps & main load circuit wiring (copper) of min 16 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection class-2 (Hansel make). The circuit should be also have provision for manual operation (i.e. sensor by pass option) complete all as specified and directed by Engr-in-Charge. Model No SWADEEP 66- 8 KW1P or L&T or Havells
S&F in replacement of automatic street light control switch of 8 KW three phase using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitabe rating power contractor (s), one Incoming and three Outgoing MCBs rating of 20-32 Amps & main load circuit wiring (copper) of min 10 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection class-2 (Hansel make). The circuit should be also have provision for manual operation (i.e. sensor by pass option) complete all as specified and directed by Engr-in-Charge. Model No SWADEEP 66- 8 KW3P or L&T or Havells
S&F in eplacement of electronic ignitor suitable for 70-400 watt HPSV/MH lamp complete all as specified and directed by Engr-in-Charge.
S&F in replacement of copper wound polyester filled ballast designed for 240V supply voltage suitable for 1x400 watt HPSV/MH fittings complete all as specified and directed by Engr-in-Charge.
S&F in replacement of copper wound polyester filled ballast designed for 240V supply voltage suitable for 1x250 watt HPSV/MH fittings complete all as specified and directed by Engr-in-Charge. Cat No LTAS013 of C&S or Bajaj or CG
S&F in replacement of copper wound polyester filled ballast designed for 240V supply voltage suitable for 1x150 watt HPSV/MH fittings complete all as specified and directed by Engr-in-Charge. Cat No LTAS012 of C&S or Bajaj or CG
Supply only insulation tape 25 mm wide 6 Mtr long ISI mark of Red-Yellow-Blue-Black-Green colour complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 250 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement of T5 tube rod of 14 watt suitable street light fitting complete all as specified and directed by Engr-in-Charge.
S&F in repairs/replacement of garden light 1x18 watt CFL with lamp, spun aluminium funnel shape with clear acrylic cover with engineering plastic louvers, complete with all accessories complete all as specified and directed by Engr-in-Charge. Cat No LTGL002 of C&S or Bajaj or CG
ARNABH ASSOCIATES
MOHAN LAL AND SONS
FANGALIA TRADERS
HIMALAYA ENTERPRISES
proach associates
K S BUILDERS
PREM NATH KHAJURIA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .