| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.0 L+₹22,809.30 (0.79%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹29.2 L+₹51,095.30 (1.78%)Rejected-Finance NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹29.6 L+₹83,628.10 (2.91%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹32.9 L+₹4.1 L (14.4%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
30 Sept 2020, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Repair / maint of LT over head line, LT underground cable and connected items in MAP area repair / maintenance of LT panel, APFC panel and connected items at certain locations and all ASCON Nodes under GE (Army) Suratgarh at Suratgarh Mil Stn
2020_MES_374066_1
GE (A) SOG - 47/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹70,000
Yes
18 Nov 2020
2 Sept 2020
2 Oct 2020
2 Sept 2020
30 Sept 2020
16 Sept 2020
Amount
Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Disconnecting and re-stretching ACSR conductor of any size and re-fixing with and including new 2mm dia aluminum binding wire complete all as specified. Note :- (i) The rate quoted by the contractor shall deemed to be included for cutting / trimming of tree branches touching / approaching the LT over lines upto 3 metre width on each side with hacksaw / axe to clear the LT line including disposal of trimmed branches 100 metre away inside the cantonment area & cleaning site as directed by Engineer-in-charge. (ii) Length of each conductor shall be measured as one length.
Supplying, fixing & stretching aluminium conductor steel, reinforced (ACSR) of any size fixed on LT poles fixed on insulators and binding with & including 2 mm binding wire complete all as specified and directed by Engineer-in-Charge. Notes: - (i) The ACSR conductors shall be conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also be deemed to include for supply and fixing of binding wire, aluminum tapes etc. which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size multiplied by length of span and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.
S&F in replacement shackle type insulators, vitreous porcelain white, brown or green for working pressure 1100 volts grade of 100 mm height and 115 mm dia including galvanized mild steel straps of 31mm x 5mm size,14mm dia insulator bolts, washers and nuts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement pin type insulator of size 100mm height, 65 mm dia porcelain, vitreous white, brown or green insulator suitable for 1100 volts grade including one galvanized mild steel spindle, two GI washer and one GI nut complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles, filling & mass concrete including necessary form work complete all as specified and directed by Engineer-in-charge .
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge
Supplying, installing, testing and commissioning of thermoplastic polycarbonate IP 65 outdoor type in accordance with EN 60 529 (dust proof, weather proof & water proof) power distribution board of suitable dimension, shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extingushing, UV Resistant, silica and halogen free recyclable material, glow wire tested at 960⁰C in accordance with IEC 60 695-2-11. type tested as per IEC 61 439-1. total insulated with system. The manufacturer of board / panel shall submit a copy of ASTA certification by CPRI for the Degree of ingress protection in accordance with IEC 60529. The gasket material shall be polyurethane while the gasket shall be internally embedded including provision for taking incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable , danger board, detachable plate at bottom for cable entry etc. with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs. The manufacturer of board / panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 61 439-1. The report shall have mention of following tests performed and passed out satisfactorily:- (i) Tempreture rise. (ii) Dielectric properties (iii) Short circuit withstand current - rated peak & short time with stand current and rated conditional short circuit current. (iv) Efffectiveness of protective circuits (v) Clearance & Creepage distance (vi) Degree of protection (vii) Mechanical operation
The impact strength of polycarbonate enclosure / boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B-1 as in floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accessories :- Incoming (a) 400 Amps copper bus bar for phases and Neutral - 01 Set (b) MCCB 250 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA068092R1 / L&T cat part No CM92109OOP1OG / Schnieder Outgoing (a) MCCB 63 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 04 Nos Make - ABB ordering code No 1SDA067404R1 / L&T cat part No CM91712OOHOOG / Schnieder (b) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (c) Digital Ampere meter flush type 0-250 Amps square type 96mm x 96mm - 01 No (d) CTs 200/5 Amps - 01 Set (set of three) (f) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
All as per item No 9 above but comprising of following accessories Incoming (a) 250 Amps copper bus bar for phases and Neutral - 01 Set (b) MCCB 250 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA068092R1 / L&T cat part No CM92109OOP1OG / Schnieder Outgoing (a) MCCB 100 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA067406R1 / L&T cat part No CM90681OOLOOG / Schnieder (b) MCCB 40 Amps, 16 KA, 4 Pole, thermal Magnetic release type - 04 No Make - ABB ordering code No 1SDA066814R1 / L&T / Schnieder (c) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (d) Digital Ampere meter flush type 0-250 Amps square type 96mm x 96mm - 01 No (b) indicator lamp LED type complete - 01 Set (d) CTs 200/5 Amps - 01 Set (set of three) (f) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
All as per item No 9 above but comprising of following accessories Incoming (a) 400 Amps copper bus bar for phases and Neutral - 01 Set (b) MCCB 320 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA054436R1 / L&T cat part No CM98401OOROOG / Schnieder Outgoing (a) MCCB 100 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA067406R1 / L&T cat part No CM90681OOLOOG / Schnieder (b) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 08 No Make - ABB ordering code No 1SDA067404R1 / L&T cat part No CM91712OOHOOG / Schnieder (c) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (d) Digital Ampere meter flush type 0-350 Amps square type 96mm x 96mm - 01 No (b) indicator lamp LED type complete - 01 Set (d) CTs 200/5 Amps - 01 Set (set of three) (f) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
S & F in replacement pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
Disconnecting over head conductors and insulators any Nos on existing damaged steel tubular swaged LT poles, dismantling MS work such as cross arms /clamps/hooks etc, stay and street light (where exists), excavating and taking out damaged pole making good hole to receive new pole and S&F in same position new steel tubular swaged pole 09 meter long type 410 SP-31, re-fixing the MS work cross arms/clamps/hooks etc and insulators retrieved from dismantling and re-jointing the conductors with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying two coats of aluminium paint to remaining portion of pole, over cross arms, brackets, bracings, clamps, hooks etc and marking pole number complete all as specified and as directed by Engineer-in-charge.
M&L for painting on steel tubular poles 9 metre long including attachments (cross arms, clamps GI pipes etc) complete with one coat of aluminium paint after preparation of steel surfaces and black & yellow strips 30cm each upto 1.5 metre height from top of PCC foundation block or PCC coping including numbering of poles with synthetic enamel paint (Black) in 80mm high letters over 150mmx230mm yellow base complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in L & T / Havells / Schneider
S&F in replacement MCB, Triple Pole 40 Amps, , 415 volts, having breaking capacity 10 KA, 'C' Curve complete all as specified and directed by Engineer-in-Charge. Make :- Legrand Cat Part No 408659 or equivalent in L & T / C&S / Havells
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 25mm x 4mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts / nuts / washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engr-in-charge. Note:- (i) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position (iv) Minimum weight of reinforcement for RCC cover shall be 1 KG.
Laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 240 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions. (iii) Cable required for laying shall be issued under Schedule 'B' free for fixing only.
All as per item No 18 above but cable of cross sectional area 180 sq mm 3.5 core
All as per item No 18 above but cable of cross sectional area 120 sq mm 3.5 core
All as per item No 18 above but cable of cross sectional area 95 sq mm 3.5 core
All as per item No 18 above but cable of cross sectional area 70 sq mm 3.5 core
All as per item No 18 above but cable of cross sectional area 16 sq mm 4 core
All as per item No 18 above but cable of cross sectional area 10 sq mm 2 core
Supplying, laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 50 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc including taking down old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 25 above but cable of cross sectional area 25 sq mm 3.5 core
All as per item No 25 above but cable of cross sectional area 10 sq mm 4 core
Supplying, jointing and testing heat shrinkable type straight through jointing kit, suitable for cable of size 16 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 28 above but suitable for cable of size 70 sqmm to 120 sqmm.
All as per item No 28 above but suitable for cable of size 150 sqmm to 185 sqmm.
All as per item No 28 above but suitable for cable of size 240 sqmm to 300 sqmm.
Supplying, jointing and testing heat shrinkable type, in / out door, end termination jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 32 above but suitable for cable of size 70 sqmm to 120 sqmm.
All as per item No 32 above but suitable for cable of size 150 sqmm to 185 sqmm.
All as per item No 32 above but suitable for cable of size 240 sqmm to 300 sqmm.
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT / HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT / HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge. (Approximate length of span 40 to 50 metre) Note:-The contractor shall be responsible to maintain this item of work till the date of completion work. Nothing shall extra be paid on this account.
Taking out old unserviceable underground LT Cable with strandad aluminium conductor 1100 volts grade cross sectional area upto 95 Sqmm form trenches / floor / road / pipe / along poles and relaying in the same location after repair complete all as specified and directed by Engineer-in-Charge. Note : Excavation & earthwork shall be measured and paid seperately under respective items of BOQ.
All as per item No 37 above but cable of cross sectional area 120 sqmm to 300 sqmm
S&F in replacement cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel confirming to Fe-290 (Gde E-165) including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size complete all as specified and directed by Engr-in-Charge. Note :Exposed steel surface shall be treated with two coats of synthetic enamel paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer.
S&F in replacement stay assembly complete with accessories as shown in electrical plate No 1 using stay rod 20 mm dia x 1800mm long, stay bow 14mm dia and stay plate 30 cm x 30 cm x 6 mm including stay wire 8 SWG x 7 strands, loop type insulator with over all dimensions 90x140mm and clearence of hole 25.5mm, stay clamps and painting to exposed surfaces of mild steel work with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. Note : Excavation, earthwork and PCC in foundation shall be measured and paid seperately under respective items of BOQ.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 41 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F in replacement Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
All as per item No 47 above but 80mm bore tubing
All as per item No 47 above but 50mm bore tubing
All as per item No 47 above but 40mm bore tubing
M&L for preparation of existing painted surfaces of Panel Board / Feeder Pillar box (indoor / outdoor type), area not exceeding 10 square metre each and applying one coat of synthetic enamel paint after preparation of surfaces on external and internal surfaces of approved tint by using spray machine inclusive of writing SM / MES No / name of feeders etc. (not exceeding of height 5 cm each) including welding of broken panel door, tightening electric connection of switch gears and cleaning of vegetation all around the panels up to one meter from all sides complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge. Make : Legrand Cat Part No. DPX³ 160 420055 or equivalent in ABB / L & T / Schneider
All as per item No. 52 here-in-before but MCCB 4 Pole, 125 Amps rating, breaking capacity 25 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 160 420056 or equivalent in Havells / L & T / Schneider
All as per item No. 52 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 160 420097 or equivalent in ABB / L & T / Schneider
All as per item No. 52 here-in-before but MCCB 4 Pole, 250 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 250 420249 or equivalent in ABB / L & T / Schneider
All as per item No. 52 here-in-before but MCCB 4 Pole, 400 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 630 422007 or equivalent in ABB / L & T / Schneider
All as per item No. 52 here-in-before but MCCB 4 Pole, 630 Amps rating, breaking capacity 50 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 630 422023 or equivalent in Havells / L & T / Schneider
S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 360mm, width 25mm, thickness 12mm, suitable for 2-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 640mm, width 25mm, thickness 12mm, suitable for 3-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 940mm, width 25mm, thickness 12mm, suitable for 4-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 1250mm, width 25mm, thickness 12mm, suitable for 5-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MCB, four Pole 63 Amps, having breaking capacity 10 KA, 'C' Curve complete all as specified and directed by Engineer-in-Charge. Make :- Legrand Cat Part No 408702 or equivalent in L & T / Schneider / ABB
S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1 complete all as specified & as directed by Engineer-in-charge
S&F in replacement Digital type Ammeter 96mm x 96 mm of range 0-200 Amp, single phase, class -1 complete all as specified & as directed by Engineer-in-charge
S&F in replacement Phase indicator lamp assembly LED type complete with indicator lamp including making connections with 2.5 Sq mm copper conductor PVC insulated and PVC sheathed single core cable complete all as specified and as directed by Engineer-in-charge.
S&F in replacement 100mm size mild steel butt hinges cold rolled medium weight complete all as specified & directed by Engineer-in-Charge.
S&F in replacement 250mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in-Charge.
M&L for decarbonazing of bus bar chamber and all affected parts, after disconnecting electric connections, taking out brunt accessories / control wiring, providing insulation of suitable size around bus bar with colour coding as per engineering practice and replacement of brunt accessories (Male - female connector, tongle switch etc) and wiring, repairing of tripping mechanisam for making LT ACB panel (630 Amps to 800 Amps as per site) serviceable in all respect complete all as specified and directed by Engineer-in-Charge. Note :- Any item / spare parts required at site deemed included quoted rate no extra payment will be made on this account.
Supplying, testing, commissioning & testing of automatic intelligent power factor corrector (AIPFC) capacitor bank of capacity 50 KVAR with staging 1+2+3+4+5+10+10+15 LT 3 Phase 440 voltages 50 Hz AC supply system to improve power factor 0.80 to 0.98 automatic step wise switches capacitor panel platform mounted outdoor type, weather proof, dust vermin proof, made out of M.S. sheet 3.15mm thick and MS angle iron 40mm x 40mm x 6mm frame, factory fabricated as modulate in construction duly power coated light grey / cream color paint, front openable panel shutters with locking arrangement to facialite easy maintenance, exhaust panel in platform (as & where required), 40 x 6mm copper bus bar and necessary internal connections with 10 sqmm, 4sqmm & 1.5 sqmm insulated standered copper conductor complete comprising of the following:-
Serial Item No 70 Contd/-.... (a) 160 Amps aluminium bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 160 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA067410R1 / L&T cat part No CM090634OOMO / Schnieder Cat part No LV430320 (c) AIPFC micro processor based relay 8 stage - 01 No Make :- Epcos / Siemens / Neptune (d) Capacitor duty contactors 3 phase suitable for 1,2,3,4,5,10,10,15 KVAR = 8 Nos Make :- ABB / Siemens / Schneider (e) MCB 32 Amps, Triple Pole 240 Volts, 10 KA, ‘C’ Curve - 08 Nos Make :- ABB order code No 1SYS273012R0324 / L&T/ Schneider (f) indicator lamp LED type complete - 08 Nos (g) Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (h) Ampere meter flush type 0-200 Amps square type 96mm x 96mm - 01 No (j) LT 415 Volts current transformer (CT) of ratio 100/5, 10VA - 04 Nos (k) 440 volts 3 phase power capacitor double dielectric heavy duty 1,2,3,4,5,10,10,15 KVAR - 01 No
All as per item No 70 above but capacity 100 KVAR with staging 1+2+3+4+5+5+5+10+10+15+15+25 LT 3 Phase 440 voltages 50 Hz AC and comprising of following accessories:- (a) 200 Amps aluminium bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 250 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA068092R1 / L&T cat part No CM92109OOP1OG / Schnieder (c) AIPFC micro processor based relay 12 stage - 01 No Make :- Epcos / Siemens / Neptune (d) Capacitor duty contactors 3 phase suitable for 1,2,3,4,5,5,5,10,10,15,15,25 KVAR = 12 Nos Make :- ABB / Siemens / Schneider (e) MCB 32 Amps, Triple Pole 240 Volts, 10 KA, ‘C’ Curve - 12 Nos Make :- ABB order code No 1SYS273012R0324 / L&T/ Schneider (f) indicator lamp LED type complete - 12 Nos (g) Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (h) Ampere meter flush type 0-200 Amps square type 96mm x 96mm - 01 No (j) LT 415 Volts current transformer (CT) of ratio 100/5, 10VA - 04 Nos (k) 440 volts 3 phase power capacitor double dielectric heavy duty 1,2,3,4,5,5,5,10,10,15,15,25 KVAR - 01 No
Inspection/checking of APFC panel 3 phase, 440 voltage 50 Hz AC supply system to improve power factor 0.80 to 0.98 automatic step wise switched capacitor panel to make it serviceable with the help of connecting relays, capacitors, contactors, MCB's, CT's etc and rectifying the defects, replacement of unserviceable part as required at site and cleaning of AMF panel as detecting during inspection or pointed out by users/department and carry out maintenance complete all as specified as directed by Engineer-in-charge. Note:- Spare parts required shall be measured and paid for separately under respective items of BOQ as supply only..
Supply only in replacement of AIPFC micro processor based relay 4 Stage PFC CONTROLLER-BR-4904-04 ST RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton
Supply only in replacement of AIPFC micro processor based relay 8 Stage PFC CONTROLLER-BR-4000-08 ST RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton
Supply only in replacement of AIPFC micro processor based relay 12 Stage BR6000 SERIES 12 STP RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 1 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32447A4012B 40 / GE/L& T / Siemens / Crompton
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 2 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32447A4022B 40 / GE / L& T / Siemens / Crompton
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 3 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4032B 40 / GE/L& T / Siemens /Crompton
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 4 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4042B 40 / GE / L& T / Siemens /Crompton
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 5 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4052B 40 / GE / L& T / Siemens /Crompton
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 10 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4102B 40 / GE / L& T / Siemens / Crompton
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 12.5 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part-B32448A4122B540 / GE / L& T / Siemens / Crompton
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 15 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4122B540 / GE / L& T / Siemens /Crompton
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 10 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge.. Make - EPCOS Cat Part No B44066S1011C240N 1 or Equvilent in L&T / GE / Siemens / Crompton
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 16 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge. Make - EPCOS Cat Part No B44066S1611C240N 1 or Equvilent in L&T / GE / Siemens / Crompton
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 25 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge.. Make - EPCOS Cat Part No B44066S2511C240N 1 or Equvilent in L&T / GE / Siemens / Crompton
Supply only in replacement of current transformer of ratio 100/5, 5 VA with accuracy class 1.0 including connection with 4 sqmm twin core copper PVC cable complete all as specified and as directed by Engineer in charge.
Supply only in replacement of current transformer of ratio 200/5, 10 VA with accuracy class 1.0 including connection with 4 sqmm twin core copper PVC cable complete all as specified and as directed by Engineer in charge.
Disconnecting LT cable connection, opening 3 phase voltage stabilizer upto 500KVA capacity, of any make, balanced or unbalanced type, draining of transformer oil, replacement of unserviceable parts, servicing of moving parts, adjustment of bush assembly, tightening of electric connection, repair of worn out nuts, bolt, gaskets, carbon brushes, dehydration & filtration of transformer oil re-filling of transformer oil including painting with one coat of grey synthetic enamel paint after well cleaning and preparation of surface including marking of SM/MES No with white synthetic enamel paint, reassembling, making connections and testing complete all as specified and directed by Engineer-in-charge. Note:- (a) Parts required to be replaced shall be measured and paid for separately as supply only. (b) The cost of minor spare parts as mentioned in the item deemed included in the quoted rate.
Supply only in replacement micoprocessor based control card for each phase suitable for three phase servo voltage stabilizer upto 500KVA capacity of existing make complete all as specified and directed by Engr-in-Charge :- Make : VOLINA / BLUE LINE / SINETRAC
Supply only in replacement Digital Voltmeter 0-500 V, size 96 mm square type suitable for three phase servo voltage stabilizer upto 500KVA capacity of existing make complete all as specified and directed by Engr-in-Charge Make: AE / BCH / L & T
Supply only in replacement Digital Ampere meter 0-100 Amps with CT size 96 mm, square type suitable for three phase servo voltage stabilizer upto 500KVA capacity of existing make complete all as specified and directed by Engr-in-Charge Make: AE / BCH / L & T
Supply only in replacement Servo synchronizing motor single phase AC 230 V, 3 Kg torque suitable for three phase servo voltage stabilizer upto 500KVA capacity of existing make complete all as specified and directed by Engr-in-Charge Make: AE / BCH / L & T
Supply only in replacement Servo synchronizing motor single phase AC 230 V, 10 Kg torque suitable for three phase servo voltage stabilizer upto 500KVA capacity of existing make complete all as specified and directed by Engr-in-Charge Make: AE / BCH / L & T
Supply only in replacement dimmerstate unit suitable for 63 KVA, 32 Amps capacity of three phase servo voltage stabilizer complete all as specified and directed by Engineer-in-Charge :- Make: VOLINA / BLUE LINE / SINETRAC
All as per srl item No 95 here-in-before but capacity 75 KVA, 40 Amps.
All as per srl item No 95 here-in-before but capacity 100 KVA, 60 Amps.
Supply only carbun bush suitable for three phase servo voltage stabilizer upto 200KVA capacity of existing make complete all as specified and directed by Engr-in-Charge Make: AE / BCH / L & T
Supply only over / under voltage cut off relay suitable for three phase servo voltage stabilizer upto 200KVA capacity of existing make complete all as specified and directed by Engr-in-Charge Make: AE / BCH / L & T
Supply only transformer oil (confirming to IS-335/93) having dielectric strength not less than 60 KVA complete all as specified and as directed by Engineer-in-charge. Make:- Power oil,Castrol. Note: Test report for transformer oil from manufacturer shall be submitted --------------------------------------------------------------------- Note :- A sum of Rs. 202974/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 27 & 28 (Schedule of Credit) of Tender documents.
GURDEEP SINGH AND COMPANY
M/S GODARA CONSTRUCTION CO.
BHADU BUILDERS
SRI SAI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .