GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
SPECIAL REPAIR /REPLACEMENT OF LT PANELS/ FEEDERS PILLERS AND SHIFTING / RELOCATION OF 03X DG SET , OXYGEN PIPE LINE AND SEWAGE LINE AT MH JAIPUR UNDER JAIPUR MIL STN
2022_MES_538787_1
GE/J-26/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAIPUR
As per NIT
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹84,240
Yes
26 Sept 2022
16 Jul 2022
13 Aug 2022
16 Jul 2022
11 Aug 2022
29 Jul 2022
16 Jul 2022 - 28 Jul 2022
Amount
Material and labour for shifting of DG set of capacity from 160 KVA to 250 KVA including disconnecting all connected items including cable, Panel, shed from foundation to proposed site as directed place of installation and installing on PCC platform /plinth with necessary fixing arrangement with shed and connecting input and output electricity connections with minor spares, commissioning and testing complete all as specified and as as directed. Note:- (i) Cost for taking down, loading/unloading, shifting transport/ T&P (crane and vehicle) for shifting to DG Set shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. (ii) In case damage to DG set during to the shifting, panelty/ recovery cost of DG set shall be made from the contractor payment as directed. (iii) Shifting of shed including taking out from foundation and shfting and fixing at new loaction with PCC in 1:3:6 for pole deemed included in quoted rate.
M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.25 mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI strip of size 32x6mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 40mm bore GI pipe medium grade for protection of GI strip upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr, all as specified ans shown in Electrical plate No. 3 of SSR Part-1, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion complete Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
M&L for foundation of size 5.5mx 2.25mx 0.75m for installation of DG set using PCC 1:2:4 type B2, including necessary form work, anchor Nut/ Bolt all as required. DG set foundation hight will be 300 mm above from ground level and neccesaary arrangments must be included to withstand against vibration and self weight of DG set . Note: - (i) The design of Foundation of DG set wil be approved by GE (ii) Excavation of Earth work removal of same deemed included in quoted rate.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm 3 core.
M&L for taking out old under ground HT / LT XLPE/PVC cable of any size from trenches/wall/roof/road/pipe/pole/DB including taking out of brick layer and segregation/staking of serviceable brick from trenches for re-use and broken brick bats removing from site making good the disturbed surface with PCC 1:2:4, type B-1, 100mm thick for wall/ road/ PCC complete all as specified and as directed by Engineer-in-Charge. Note : (i) Cost of Earth work will be measured and paid relevant items (ii) Cost of PCC shall be deemed to be included in quated rate by tenderer
Laying only serviceable old LT /HT XLPE Cable of any size any make in trenches/ throw pipe/ under culvert/ on the wall on the ground including all necessary connection, clamps, nuts, bolts washers complete all as specified and directed.
Supply fixing and testing commissioning and errection of DHP medical grade pipe Solid drawn, seamless, dioxidised, non-arsenical, half hard tempered and degreased,materials confirming to BS: 6017/1981 Table -2 (Cu-DHP) manufactured as per BS "2871/1971 part 1 Table X and dimension tolerance confirming to BS-EN 1057 pipe fitting confirm to BS -EN 12543: 1998 for following size: Make : Janaya/ Mexflow or equivalnet as approved by GE (a) 12 X 0.7 MM OD
(b) 15 X 0.9 MM OD
(c) 22 X 0.9 MM OD
Material and labour for taking out of serviciable DHP medical grade pipe Solid drawn, seamless, dioxidised, non-arsenical, half hard tempered and degreased from wall/trench and refixing same at new location with suitable welding brezzing for connection with existing or new pipeline or as directed for following size: (a) 12 X 0.7 MM OD
(b) 15 X 0.9 MM OD
(c) 22 X 0.9 MM OD
M&L for sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying including gently punning around cable complete all as specified in SSR Part-I and directed.
M&L for bricks well burnt sub class 'B' laid in trenches flat with width equal to length of brick for cable protection laid across the cable complete all as specified and directed.
Supply and fixing Cast iron pipe 150mm bore, centrifugally cast, class 'LA' , (ISI marked) with both ends flanged pipes laid in walls / poles / laid in road crossing etc complete all as specified and as directed.
Supply and fixing Cast iron pipe 100mm bore, centrifugally cast, class 'LA' , (ISI marked) with both ends flanged pipes laid in walls / poles / laid in road crossing etc complete all as specified and as directed
S&F galvanised mild steel tubes "Medium grade" of 100 mm bore (ISI marked) with all fitting( ISI marked) and fixed to walls and ceilings or laid in floors/ trenches and under road, complete all as specified and directed.
S&F galvanised mild steel tubes "Medium grade" of 80 mm bore (ISI marked) with all fitting( ISI marked) and fixed to walls and ceilings or laid in floors/ trenches and under road, complete all as specified and directed.
S&F galvanised mild steel tubes "light grade" of 80 mm bore (ISI marked) with all fitting (ISI marked) and fixed to walls and ceilings or laid in floors/ trenches and under road, complete all as specified and directed.
All as per Item No 15 above but 100 mm size.
Taking out old servicable pipe Galvanised Iron, medium grade 80 mm dia including fittings fixed to walls / poles / laid in road crossing etc
Laying only serviciable pipe Galvanised Iron, medium grade 80 mm dia including fittings fixed to walls / poles / laid in road crossing etc
S&F in replacement of ductile iron fittings, ISI marked viz bends, tapers, reducers, tee pieces (single or double branch) any type, angle / radius and straight connecting pieces, but all ends flanged, size of pipe upto 200 mm bore, complete all as specified and directed.
M& L for 80 mm thick Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006, M-40 Grade, with grey cement laying over and including 25mm thick sand layer complete all as directed.
Taking down old unserviceable LT panel of any discription and size including demolished PCC foundation and all accessories such as MCCB/Cubical type switch /Measuring instruments /indicating lamps etc complete all as specified and directed.
Supplying, installation, testing & commissioning CPRI approved outdoor cubical type MV feeder pillar box suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system with short circuit withstand capacity 35 MVA for 1 second, IP 54 protection, fabricated in compartmentalized design from stainless steel sheet (SS 316) 2.0 mm thick totally enclosed, dust, weather & vermin proof, having TPN copper bus bars of rating 1.5 times that of controlling MCCB supported on 'F' class SMC insulators, bottom base channel of MS section not less than 75 mm x 40 mm x 5 mm thick, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size copper bus bars and control wiring with minimum 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates including digital multi functional meter to measure voltage, current, PF & frequency and mounted on by making suitable PCC foundation, necessary inter connection including following controls : Incoming : Two numbers MCCB 630 amp, 3 pole, Ics 16 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420005 or equivalent as approved by GE Outgoing:- Online Changeover switch of capacity 630 Amp TPN side hand operated = 01 Nos
M&L for of bus bar chamber pedestal type of size 75 cm x 60 cm x 40 cm fabricated in compartmentalized design from stainless steel sheet (SS 316) 2.0 mm thick totally enclosed, dust, weather & vermin proof duly painted and consisting with aluminium bus bar 3 phase and neutral 4 Nos 400 Amp fixed on insulators and one MCCB TPN 100 Amp, 25 KA rupturing capacity including necessary fixed in PCC 1:3:6 using 20 mm graded stone aggregate including danger plate etc complete.
Supply and fixing in replacement of MCCB, 3 phase, 4 pole, 415 volts of capacity 400Amps, breaking capacity not less than 50 KA, adjustable thermal and fixed magnetic setting, Ics=100% Icu conforming to IEC-947, IS-13947 including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and directed.
All as Srl per item No 28 here-in-before but capacity of MCCB 200 Amps 25 KA
All as Srl per item No 28 here-in-before but capacity of MCCB 100 Amps 25 KA
All as per Srl item No 28 here-in-before but capacity of MCCB 315 Amps 36 KA
M&L for Opening /disconnecting the electrical connection of defective/ burnt out underground LT cable of any size 2 to 4 core from main switch /DB /junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable, providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/ DB/ Junctionbox/ LT panel/O/H line etc all as directed. Note:- (I) the cost of required earth work ie excavation, returning filling, relaying of sand/bricks and cost of drawing the required length from protection pipe, breaking of required brick work/ plaster /concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.
Supply and fixing PVC separator suitable for 3/4 way conductor complete all as directed by Engineer-in-Charge.
Material and labour for replacement of indicator lamp in differenet colour code LED /Neon type (as per sample) complete (RYB) including wiring with copper conductor cable of suitable size all as specified and as directed by Engineer-in-Charge.
Material and labour for replacement of digital voltmeter of suitable range including wiring with copper conductor cable of suitable size all as specified and as directed.
Material and labour for replacement of digital ammeter of suitable range including wiring with copper conductor cable of suitable size all as specified and directed
Material and labour for rewiring of LT panel/feeder of any size including replacemnt of wornout parts , nut , bolts,backlite surface and cleaning of burnt/rusted surface/ all as specified and directed.
M&L for Preparation of the old painted surfaces of feeder piller boxes/panels/boards of any size any description and in any position including removal of faded & deteriorated paint eaither by hand scrapping or by blow lamps, applying necessary filler coat and scrapping as required and applying two coats of synthetic enamelled paint (grey in colour) with using spray machine on old prepared surfaces complete all as spcified and directed.
M&L for Repair to LT panel board body by replacing MS sheet of existing gauge size and shape for door shutter/body of feeder piller, including replacement of broken hinges and all as specified and directed.
Supply and fixing in replacement Aluminium bus bar 800 Amp capacity in existing LT panel/feeder piller /Transformer etc including provision of insulation tape RYB in colour and holes, nuts & bolts etc
Supply and fixing in replacement Aluminium bus bar 630 Amp capacity in existing LT panel/ feeder piller etc including provision of insulation tape RYB in colour and holes, nuts & bolts etc
Supply and fixing in replacement Aluminium bus bar 400 Amp capacity in existing LT panel/feeder piller etc including provision of insulation tape RYB in colour and holes, nuts & bolts etc
Supply and fixing in replacement danger notice plate of size 20x15cm made out of MS sheet 1.6 mm thick, vitreous enameled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts on LT poles complete all as directed.
M&L for 40mm graded crushed stone aggregate, deposited, spread and leveled in layers not exc 15 cm thick, rammed to a true surface, under 2/4 pole structure and around the 2/4 pole structure & outdoor electrical installations, complete all as specified and as directed.
M&L for cable jointing kit for upto 1.1 KV (Earthed) grade cable for indoor heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of following size :- 25 sqmm 4 core
50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
240 to 300 sqmm 3.5 core
400 sqmm 3.5 core
M&L for cabletermination kit for upto 1.1 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of following size :- 50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
240 to 300 sqmm 3.5 core
400 sqmm 3.5 core
S&F 11000 volt grade heavy duty HT XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 120 Sqmm nominal cross section 3 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed.
S&F 1100 volt grade heavy duty XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of following size laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. 400 sqmm nominal cross section and 3.5 core
size 300 Sqmm nominal cross section 3.5 core.
size 240 Sqmm nominal cross section 3.5 core.
size 185 Sqmm nominal cross section 3.5 core
size 95 Sqmm nominal cross section 3.5 core
size 50 Sqmm nominal cross section 3.5 core
size 35 Sqmm nominal cross section 3.5 core
size 16 Sqmm nominal cross section 4 core
M&L for construction of cable trench /Duct of brick masonry of size 400 mm x 300mm (internal size) including necessary excavation and earth work, PCC 1:2:4, type B-2, 100mm thick for foundation, 23cm thick both side brick walls in CM 1:4, Plaster in CM 1:6 on inside and out side (above ground ), PCC cover over duct of required size with hole of size 15 mm in cable trench with MS handle of approved quality complete all as directed. Note:- (i)cost of Earth work, PCC, brick works is deemed to be incuded in Quated rate (ii) Cable trench/duct with PCC cover shall be measure and paid as one unit in RM.
M& L for shifting of existing LT Panel disconnecting existing electrical connection from MCCBs/MCB/Bus bar , taking out required length from loop and reconnecting with electrical connection at new location including breaking / cutting existing PCC foundation and fixed at new location in PCC 1:3:6 using 20 mm graded stone aggregate incluting paitning with danger sign on Panel not beyond 300 mtr or as specifiied.
S & F in replacement lightening arrester metal oxide non-linear expulsion type rupturing capacity 65 KA, porcelain, conforming to IS-3070 Pt-I suitable for 11 KV, HT over head line complete including nuts, bolts, clamps, brackets etc and connecting with GI earth wire, discharge capacity 65 Kilo Amps.
M&L for separation /segregation of electrical circuits of LT cables from LT Panel to VTPN/DB box/Fidderpillar box for making new electrical circuit for lighting load and AC Load bY discoonectiong the existing cable connection from MCCB/MCB/DB/VTPN/TPN and connectiong the new/existing panel /MCCB or as specified.
M&L for taking out old unservicable LT/HT UG XLPE/PVC cable any size any make by discharging and disconnecting from Panel/ MCCBs/ DBs from trench wall/ roof/ pole/ floor/ trenchs including taking out old brikcks and cable protection cover making good with PCC 1:2:4, type B-1, 100mm thick for wall/road/pcc complete all as specified and directed. Note : (i) Cost of Earth work will be measured and paid relevant items (ii) Contractor will submit details of taking out of old spare cables to Enginner in charge and inspection/test of site shall be carried out by the rep of accepting officer. (iii) Cost of PCC shall be deemed to be included in quated rate by tenderer (iv) Old Cable retireved from this items will be contractor credit and amount for this will be deducted in schedule of credit.
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sq m on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm.etc complete as per specified and directed.
Removing excavated material exceeding 250 metres but not exceeding 500 metres and depositing where directed at a level n exc. 1.5 m above the starting point. etc complete as per specified and directed.
M&L for Cement concrete (1:4:8) type D2, using 40 mm graded aggregate in foundations, filling and mass concrete etc complete as per specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
M&L brick work with subclass 'B' bricks straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls mixed with WPC 3% by weight of cement finished even & smooth without using extra cement. etc complete all as specified & directed. Note:- WPC shall be measured and paid separately
Supply only Integral water proofing compound.
M&L Precast cement concrete B1 type, (1:2:4) using 20 mm graded aggregate in landings cover slabs (for manholes etc.) chullah, hoods, chajjas, water troughs mangers, shelves and similar articles with plain faces with set in cement mortar 1:6. etc complete all as per specified and directed.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cracking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. etc complete all as specified & directed.
Supply and laying DWC pipes ( Double wall corrugated) of class SN-4, IS-16098 (Part-II) of size internal dia of 150 mm, laid in trenches and jointed complete with coupler,bends,tee, reducers etc complete all as specified & directed. Make: Ultra plus DWC PE pipe of Supreme/ Corfit of Prince/ D-Rex DWC of Astral or equivalent as approved by GE
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid, bedded and pointed in any mortar and removal of rubbish off the site all as specified.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-40 Grade,with grey cement
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for providing precast cement concrete 1:3:6 block masonary with solid blocks, exc 10cm in width and setting in cement mortar 1:4 complete all as specified and as directed.
Cutting into existing manholes for connecting new drains of 150mm internal dai of pipes, making hood to pope and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required
Schedule of Credit
SHREE BHAGWATI ENTERPRISES
M/S TRADE LINKERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .