Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC VPO JAGRAM BASS TEHSIL BADHRA DISTT CH DADRI 127308 | JAGRAM BASS | CHARKHI DADRI | HARYANA | 127308 | ₹2.8 Cr | L1 | Accepted-AOC L1 |
| 2 | Not Admitted-Fee/PreQual/Technical 62 BALSAMAND ROAD HISAR 125001 | HISAR | HARYANA | 125001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.8 Cr
EMD Value
₹3.7 L
Closing Date
3 Jun 2022, 11:00 amClosed
XEN Adampur
Canal Colony Hisar
Dewatering SSWL Digging of Bore Operation with Solar Pumps outfall in various points / channel in village Chider Dist. Fatehabad
2022_HRY_223488_2
adampur0522
Open Tender
Civil Works
Item-rate/Agreement basic
365 days
Hisar
Please refer Tender documents.
5 documents required · 5 mandatory
₹15,000
₹3.7 L
Yes
Hisar
20 Dec 2022
27 May 2022
3 Jun 2022
27 May 2022
3 Jun 2022
27 May 2022
31 May 2022
Amount
Boring/drilling bore well of required dia for casing/ strainer pipe,by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, luding hire & running charges of all equipments, tools, plants & machineries required for the job, allcomplete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. 10 main pumps + 2 auxillary pumps for sump wellsAll types of soil 300 mm dia
Development of tube well in accordance with IS : 2800 (part I) hour 592 561 1153 and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V'' notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 10 main pumps + 4 auxillary pumps
Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia
MS Steel 10mm thick Plate for covering 3 ft x3 ft = 9 sqft or 0.84 sqm
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tube well as per IS: 2800 (part 1), including necessary bolts & nuts of required size complete
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): 150 mm dia class 1
150 mm i/d PVC 10kg.cm2, 2234 m x 2
200 mm i/d PVC 10kg.cm2, from NSK to Hansawala 2911 (2 no.) for 6 pumps + NSK to hansawala disty 5700 m (2 no.) for 6 pumps
Stringing out A.C./P.V.C pipes and specials casting along trenches and laying the same in trenches, to correct alignment and gradients including cartage from divisional stores or nearest railway station to site of works and return of pieces of pipes to stores. 150 mm
Stringing out A.C./P.V.C pipes and specials casting along trenches and laying the same in trenches, to correct alignment and gradients including cartage from divisional stores or nearest railway station to site of works and return of pieces of pipes to stores. 200 mm
Excavating trences of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not
All kinds of soil pipes, cables etc. exceeding 80mm metre dia. But not exceeding 300mm dia
Providing GI pipes class B marked with IS: 1239 in 3.05 m length, their threading and welding with flanges (Heavy Duty) on both sides, jointing with nuts and bolts ( 'W make), rubber gaskets, lowering into Tube wells and testing including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. 80 mmi/d
Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge.
Extra for fixing sluice valves/flap valves socketed or flanged including cartage from store or nearest Railway Station to site of works
Rubber insertion for 200 mm dia pipe joint
225mm outer dia filter Jali (1 O Kg/CM2)
Providing and fixing 250 mm M.S. clamp as for suitable pipe with nut & bolt each complete in all respect as per directions of Engineer-in-charge
Providing & fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with 5312 including nuts & bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 80 mm i/d
Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths cast iron (Cl) standard specials plain /flanged/ socketed confirming to IS13382 with rubber ring, nut bolts and rubber sheet such as tees, bends, tapers, caps etc. complete ncluding all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. upto 300 mm dia
Laying of underground cable 0.75 metre below ground level covered without sand and bricks including excavation and refilling of trenches.:-
Solar pump controller is specially designed electronics to run the solar pump through solar power.Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage It will get maximum possible power from solar panel for particular point of time by using maximum power point tracking (MPPT) Algorithm. It also controls all the parameters to run the pump in safe environment and provide many useful protections like, dry run, over voltage, under voltage, reverse polarity etc., mobile discharge controller, GPS tagged, variable frequency drive, SPD, IOT based new age monitoring system, complete in data storage internet controlled
Supplying, erection testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034 - 1989 (as amended up to date for pumps ) and IS 9283 – 1979 (as amended up to date for motor ) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause – 4 of IS 8034 – 1989 and clause 4.1 of IS 9283 – 1979. Varuna, Oswal,Lubi, Crompton make complete in all respect, with complete onsite service for 7 years maintenance period, 400 LPM /40 M Head/ 10 BHP, 10 main pumps + 4 auxillary pumps, 5 year warranty and service period
Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-(a) Solar Photovoltaic Module manufactured in India, conformingto IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part 2. Solar Photovoltaic Module conversion efficiency shall not beless than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity,which should not be less than 90% at the end of 1 O years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Inputvoltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from O to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequenc (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required
G.I Barbed Wire Fencing 1.8 Metre High Providing and fixing 1.8 metres high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 metres centre to centre founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and comer post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, tum buckles etc complete as per clause 807, 16 mtr for each pump
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work 1:3:6 (1 Cement : 3 coarse sand (zone-Ill): 6 graded cum stone aggregate 40 mm nominal size below plinth level and up to Floor IV level: 20 number crossings over pipe, 6ft x 4ft x 4ft = 96 cft or 2.72 cum, sump chambers 2.62 cum per chamber
Brick work with common burnt clay non modular bricks of class designation 10 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) (-)B.Bat
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .