Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.1 L+₹87,079.95 (6.14%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹16.8 L+₹2.6 L (18.7%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹17.1 L+₹2.9 L (20.5%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹19.5 L+₹5.3 L (37.3%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹18.4 L
EMD Value
₹36,800
Closing Date
11 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
PROVN OF CERTAIN SANCTION JOB AT AF STATION FARIDABAD
2020_MES_400335_2
GE (FBD)/AF-27/2020-2021
Open Tender
Civil Works - Canal
Item Rate
180 days
AF STATION FARIDABAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF FARIDABAD
₹36,800
Yes
2 Feb 2021
24 Dec 2020
13 Jan 2021
24 Dec 2020
11 Jan 2021
28 Dec 2020
60 days
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and as directed by Engineer-in-Charge.
Demolition of reinforced cement concrete in roof, floors (other than ground floor), beams, stair case, landing, chhajas and similar suspended work complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick work or stone /boulder masonry, built in cement mortar and desposal of debris complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in Hard/dense soil complete all as specified and as directed by Engineer-in-Charge.
M&L PCC in 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation/drains and surface channels etc complete all as specified and as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in Columns, pillars, piers, postsand struts etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-Charge.
M&L TMT bars 10 mm dia & over cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends & binding with & including mild steel wire (not less than 0.9 mm dia) or securing with clips quality conforming complete all as specified and as directed by Engineer-in-Charge.
All as per item No 9 here-in-before but 6 mm to 8 mm dia complete all as specified and as directed by Engineer-in-Charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed by Engineer-in-Charge.
M&L for Formwork to sides of Square,rectangular or polygonal pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed by Engineer-in-Charge.
M&L for Formwork to flat sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed by Engineer-in-Charge.
M/L for brick work with sub class `B' bricks straight or curved on plan exc 6m mean radius built in cement mortal 1:4 using old size bricks complete all as specified and as directed by Engineer-in-Charge.
M&L for 15 mm thick rendering on fair faces of brick work or cement concrete surfaces in cement mortar 1:4, finished fair and even without using extra cement incl mixing of water proofing compound as per manufacturer's instructions complete all as specified and as directed by Engineer-in-Charge. (Note: Water Proofing compound shall be measured and paid for separately)
Supply only integral water proofing compound complete all as specified and as directed by Engineer-in-Charge.
Preparing new or old plastered surfaces of walls and applying two coats of exterior emulsion paint (Weather Coat) over a coat of priming paint on roof boarder, drops, fins, chajja / roof facia, column etc, complete all as specified and as directed by Engineer-in-Charge.
Rendering, 10 mm thick, in cement mortar 1:4, on wall surafaces, as backing coat to tiles complete all as specified and as directed by Engineer-in-Charge.
M&L for Granite 20 mm thick (of any type ) (table runned and polished ) in floors, steps , jamns, pillars,window-cills,cooking plateforms and vertical surfaces bedded and jointed with grey cement slurry and pointing in white ciment (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer-in-Charge.
S&F Framed work such as grills, gratings, etc.for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-Charge.
Material and labour for providing PVDF aluminium composite panels shall consist of following (I) Aluminium sheet making a total panel thickness of 4 mm with outer surface finished with PVDF based coating 0.25mm ,inner surface finished with a thin coat of polyster paint. The cleness of aluminium cover sheet shall be 0.50 mm inner core shall be of LDPE (II) aluminim framing of section 25 mmx50 mm x1.50mm thick , (III) aluminium grid shall not be exceed 1.0 sqm each the aluminium grid not more than 1 m c/c shall be fixed with MS angle 30x30x5 mm projected 150mm from surface of wall, (IV) Colour shall be approved by GE. Note: Canopy,borders, projections etc will be measured in sqm for payment purpose.
Excavating in post holes each nexc 0.5cum getting out in soft/loose soil,ramming earth filling or broken rubble mixed with earth around in layers nexc 25cm watering and removing surfaces soil to a distance nexc 50m and making good surfaces complete all as specified and as directed by Engineer-in-Charge.
S & F MS steel work in tubular trusses including special shaped washers etc., complete using but ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240 with one shop coat of zinc chromate primer paint complete all as specified and as directed by Engineer-in-Charge.
M & L mild steel plates (Plain or chequred) channel square cut or not chequred (ordinary and counter sunk) ferming holes, sithout any attachment for Fe-410-W Gde-E 250 quality 'A' complete all as specified and as directed by Engineer-in-Charge.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe- 290 (Gde E- 165) complete all as specified and as directed by Engineer-in-Charge.
S&F Pre-painted galvatume aluminium zince coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge.
M&L for brickwork using old size bricks Sub class B straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed by Engineer-in-Charge.
M&L for 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed by Engineer-in-Charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge.
M&L for 100mm thick cement concrete type D-2 1:4:8 using 40mm graded aggregate as in subbase , floor, paving etc including necessary formwork complete all as specified and as directed by the Engineer-in-Charge
M&L for screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge.
M&L for chequered and coloured cement concrete car parking tiles 20 to 25mm thick (square/ rectangular) area of each tile exc 0.09 sqm but n.exc 0.25 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-in-Charge., (Note- colour and design will be approved by GE)
M&L for Pre-cast cement concrete solid blocks as in kerbstones(factory made), exc.10 cm in width, in 1:2:4 type B1 using 20mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.. Make:- Raj tiles and eqivalent
M&L for application of two coat of synthetic enamel paint over a coat of primer on with preparing new plastered /concrete surfaces as in kerb stone of foot path with different tints in alternate strips matching to existing etc after necessary preparation complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in any position not otherwise specifically provived complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 (40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-Charge.
M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 15mm thick in CM 1:6 over brick or concrete wall surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
S&F Joist channel angle or tee sections ficed independently without connecting plates etc (cut to ordinary lengths i.e within 20mm of the length indicated) FE 410-W (Gde-E250 quality A complete all as specified and as directed by Engineer-in-Charge.
S&F mild steel flat iron asstruts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge.
S&F mild steel screw bolts(Machine made) with hexagonal or square head at one end and screwed the other end n exc 5 cm long and diametre of neck exc 5 mm but n exc 10 mm dia complete all as specified and as directed by Engineer-in-Charge.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and as directed by Engineer-in-Charge.
Fixing only Chain link fencing including line wires any mesh size and type to any type of standards, rails straining bolts etc including provision of binding wire complete all as specified and as directed by Engineer-in-Charge.
Supply only for TMT bar 8 to 10 mm dia bent to shape etc, and fixed asa in line wire for chain link fencing complete all as specified and as directed by Engineer-in-Charge.
S&F Framed work F-410W(Gde E-250) quality-B as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed by Engineer-in-Charge.
M&L for Providing precast cement concrete type b0 1:2:4 (12.5mm graded aggregate) set in cement morter 1:4 louvres and jallies, 25mm thick (mea sured solid outer to outer edge), including all mould- ings but excluding frame (Pre cast frame shall be measured separately and paid complete all as specified and as directed by Engineer - in - Charge. (Note:- Design of jali will be approved by GE)
M&L for preparation of new cemented surfaces and applying two coats of weather proof emulsion (Apex Ultima) of approved colour over a coat of exterior wall primer in (projections of column/wall/edges of chajja, roofs and other narrow locations in buildings upto ground plus three floor) complete all as specified and as directed by Engineer-in-Charge.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide priner including preparation on new steel surfaces of any description not other wise described over 10cm width or girth complete all as specified and as directed by Engineer-in-Charge.
Surface Excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in Hard/ dense soil complete all as specified and as directed by Engineer-in-Charge.
M & L 100mm thick PCC (1:2:4) type D-2 using 40mm graded stone aggregates in PLITH/ HARD STANDING complete all as specified and as directed by Engineer-in-Charge.
M&L for thick machine cut kota stone slab flooring20-25 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, moulding on edge and polishing over and including 20 mm thick screed bed in CM 1:4 complete all as directed by engineer-in-charge
M&L for providing PCC type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete all as specified and directed by Engr-in-charge.
S&F aluminium door shutters air tight with natural anodized aluminium frame size of 63.50 x 44.45 x 1.80 mm with rebate and fully panelled (hollow profile PVC panelling of thickness 12 mm) with centre partition with middle rail (all aluminium member Top, bottom, verticle & middle of shutter made of size 82.55 x 44.5 x 1.80 mm thick including necessary joining cleats, glazing clips, rubber packing with anodized aluminium beading/glazing clip size 19 x 17.30 x 0.7 mm, wt 0.097 kg/RM of both side and fixing aluminium fitting i.e aluminium hinges 100 mm three numbers,alluminium door stoper handles 200 mm long two numbers; tower bolts150 mm 3 numbers and mortic lock with 6 lever fitting should be (ISI marked) complete all as specified and directed. (Rates will also include making good floor/wall jambs of doors/windows surface with plaster and match with existing finshes) complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs anodized aluminium powder coated window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55Kg/m including necessary jointing cleats, glazing clips rubber packing, anodised aluminium snap beading screws etc complete all as specified and as directed by Engineer-in-Charge.
S&F sheet glass5.5 mm thick ordinary quality and glazing with oil putty/wooden beads in square n exc 0.5 sqm in each pane complete all as specified and as directed by Engineer-in-Charge.
M&L for preparing New plastered surfaces and applying two coats of distemper oil emulsion on surfaces of walls over a coat of 3 mm thick wall care putty complete all as specified and as directed by Engineer-in-Charge. ( Note-work shall be got executed through skilled representative of manfcture company)
M&L for rubber cement concrete chequered tile 25 cm x 25 cm x25 mm thick with coloured and white pigment laid over screed bed or bedding layer of cement mortar 1:6, 20 mm thick for laying floor finishes complete as directed by engg in charge
Surface dressing n. exc 15 cm deep in hard/ dense soil complete all as specified and as directed by Engineer-in-Charge.
Removing Excavated material not exc 50 M and depositing where directed at level not exc1.5 M above the starting point complete all as specified and as directed by Engineer-in-Charge.
M & L for Rolling and consolidating formation surfaces using power roller exceeding 8 Tonne and not exceeding 12 Tonne complete all as specified and as directed by Engineer-in-Charge.
M&L for plain cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in 100mm thick hard standing with using of glass strip for between slabes, surface finished even and smooth with out using extra cement complete all as specified and as directed by Engineer-in-Charge.
M& L For Brick work with old size sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete complete all as specified and as directed by Engineer-in-Charge.
M&L Plain cement Concrete Type B0 1:2:4 (using 12.5 mm graded stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by Engineer-in-Charge.
Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exce 200 mm thick, rough finished flat surface of concrete complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, over all size 495 mm x 420 and bowl size 410mm x 330 mm x 160mm complete all as specified and as directed by Engineer-in-Charge.
Rounding to edges of stone slabs one edge such as in steps cooking platform and other similar work complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-Charge.
S & F 15 mm bore Galvanized Steel tubes, medium grade with all fittings for water supply pipes etc., laid in trenches complete all as specified and as directed by Engineer-in-Charge.
S& F in repairs small fitings of galvanized iron heavy grade such as socket elbow nipples of different tee chuknet of any size union reduceer float valve etc for 15 mm bore 20 mm bore pipe complete all as specified and as directed by engg complete all as specified and as directed by Engineer-in-Charge.
M&L for digital design coloured Glazed ceramic tiles in vertical surfaces of size of each tile 300 x 450 mm/350 x 250 mm and 7 to 8 mm thick fixed to wall with 10 mm thick cement sand mortar in CM 1:4 set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge.
S&F 40 mm dia waste coupling of PTMT (half or full threaded) complete all as specified and as directed by Engineer-in-Charge.
S/F in repairs 15 mm two way angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make complete all as specified and directed of make jaguar or equvivelent complete all as specified and as directed by Engineer-in-Charge.
chiselling/cutting for stone/brick wall to conceal the GI pipes into the walls and including the finishing with cement motar in 1: 4 ratio and matching with existing surface all as specified and directed by Engineer-in-Charge.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-Charge.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed by Engineer-in-Charge.
Forming jambs etc., to openings, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete new work built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster or cement lime plaster of any description on bricks or stone walls etc inclusive raking our joints hacking for scrubbing down with water etc & M & L 15mm thick plaster in CM1:4 finished even & smooth without using extra cement in patches all as specified and directed by Engr-in-charge.
S & F Collapsible steel gates, top hung consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets, complete all as specified and as directed by Engineer-in-Charge.
S&F powder coated aluminium frames and shutters for doors,windows,ventilators & partitions with one or more rebates including jointing cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge. NOTE:- Floor spring/door closer ,Glazing& panelling shall be measured and paid separatly
M & L 09 mm thick both sides prelaminated Particle board, exterior grade, fixed with screws to timber frame work in cup board shutters/ shelves complete all as specified and as directed by Engineer-in-Charge.
S & F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sq. M in each pane complete all as specified and as directed by Engineer-in-Charge.
S & F 200 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and as directed by Engineer-in-Charge.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engineer-in-Charge.
S&F Door closer hydraulically regulated, designation No 3, aluminium (die cast ) body, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed including taking down old one complete all as specified and as directed by Engineer-in-Charge.
S&F mild steel 2 levers Mortice lock, vertical type, size 100 mm complete all as specified and as directed by Engineer-in-Charge.
Plain Cement Concrete Type E2 1:5:10 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge.
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by Engineer-in-Charge.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade,with grey cement complete all as specified and as directed by Engineer-in-Charge.
Plain Cement Concrete Type C1 1:3:6 (using 20 mm graded stone aggregate) in roof kerbs, mud stops or chamfered on edges complete all as specified and as directed by Engineer-in-Charge.
M/L M-25 using 20mm graded stone aggregate in foundations, footing, plinth beams, columns and slab, complete (reinforcement to be measured separately) complete all as specified and as directed by Engineer-in-Charge.
M&L for 15 mm thick cement plaster in cement mortar 1:6 on brick or concrete surface etc. on wall finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-Charge.
M & L for preparing new surfaces of walls, distempering 2 coats with oil emulsion distemper white or tinted over one coat of wall care putty complete all as specified and as directed by the Engineer-in-Charge
Excavation over areas not exceeding 1.5 M deep and getting out in Soft/ Loose Soil complete all as specified and as directed by the Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/loose soil complete all as specified and as directed by the Engineer-in-Charge
Removing Excavated soils exceeding 1.50 Km but not exceeding 5.0 Km and depositing where complete all as specified and as directed by the Engineer-in-Charge
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
Plain cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in copings, beding and benching of manholes and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by the Engineer-in-Charge
M&L coloured Glazed ceramic tiles in vertical surfaces 350 x 250 x7 mm/ 450 x 350 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed by the Engineer-in-Charge
75 mm thick Cement concrete (between wall and drain) type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing/pavings/plinth protections, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
Supply, laying & commissioning cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor 50 Sqmm 2 core complete all as specified and as directed by the Engineer-in-Charge
Excavation in trenches in soft/loose soil not exceeding 1.5Mtr wide and not exceeding 1.5Mtr depth laying of cables/poles or foundation etc and getting out all as specified and directed by Engineer-in-Charge.
Removing of surplus excavated soil to distance not exceeding 50mtr from starting point and depositing where directed at a level not exceeding 1.5 mtr above the staring point all as specified and directed by Engineer-in-Charge.
M&L for sand cusioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cables to trenches complete all as specified and directed by Engineer-in-Charge.
Supply and laid old sub class `B' bricks dry in trenches over the cables adjoining each other width wise for cable protection complete all as specified and as directed by Engineer-in-Charge.
S&F boring of holes under road pavement hardstanding by trenchless technology using ultrasound technique and necessary machine incl HDPE pipe 100mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing sheet metal enclosures for double door single pole and neutral enclosures 8 way MCB DB suitable for one No MCB SPN as incommer and 6 Nos MCB SP as outgoing complete with complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing MCB SP 6-32 Amp, 10 KA complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing MCB SPN 40 Amp 240 Volts , 10 KA complete all as specified and as directed by the Engineer-in-Charge
laxmi enterprises
MAHABIR SINGH
High Tech Metal India
M/s Vijay Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .