Tender Value
Refer Docs
EMD Value
₹58,500
Closing Date
4 Jan 2021, 9:30 amClosed
Executive Engineer Design
o/o the Estate Officer Dr YSP UHF Nauni, Solan HP
Providing Elevator in plant health clinic lab and lecture hall building at COHF Neri, Distt. Hamirpur.
2020_YSPU_43132_1
UHF/Const.1/Partfile/20/1881 dt 10-12-20
Open Tender
Electrical Works
Item Rate
180 days
Neri, Distt Hamirpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹4,000
EE Design
₹58,500
12 Feb 2021
10 Dec 2020
4 Jan 2021
10 Dec 2020
4 Jan 2021
10 Dec 2020
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface / recessed PVC conduit and earthing the light point with 1.5 sqmm HRFRLS / PVC insulated single core copper conductor cable as required complete in all respect as per satisfaction of Engineer-in-charge (Group – C).
Wiring for power plug with 2x4 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. 4 sqmm HRFRLS / PVC insulated single core copper conductor cable for earthing as required complete in all respect as per satisfaction of Engineer-in-charge.
Wiring for power plug with 4x4 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No. 4 sqmm HRFRLS / PVC insulated single core copper conductor cable for earthing as required complete in all respect as per satisfaction of Engineer-in-charge.
Wiring for circuit /submain with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 NO. HRFRLS/PVC insulated single core copper conductor cable or same size for earthing as required complete in all respect as per satisfaction of Engineer-in-charge. a). 2x10 Sqmm.
Supplying & fixing metal box of 200x150x75mm deep (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
Supplying & fixing following rating Piano-type switch / socket on the existing switch box / cover including connections etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
a)S.P. 5/6 amps one way switch, piano type.
b)S.P. 15/16 amps one way switch, porcelain base / piano type.
c)5 pin 5/6 amps socket outlet, porcelain base / piano type.
d)6 pin 15/16 amps socket outlet, porcelain base / piano type.
Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work make of M.S. angle iron 50mm x 50mm x 6mm thick duly welded complete with 3mm thick M.S. sheet fixed with hinges as open able front, complete with locking arrangement including painting and bonding to the existing earth as required complete in all respect as per satisfaction of Engineer-in-charge.
Supplying & fixing sheet metal bus-bar chamber suitable for 100 amp. 415 volts capacity with 4 Nos. copper strip bus-bars each of length 450mm & cross-sectional area (25.4mmx3.17mm), enclosure made from 1.6mm thick M.S. sheet having overall dimensions (530mmx400mmx150mm) nominal with all accessories including connections, earthing the body etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
Providing & fixing TP&N switch disconnector fuse unit cubical type, 415/500 volts with 3 Nos. HBC/HRC fuses, in sheet steel enclosure including drilling holes on the board, connections, earthing the body etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
a)63 amps. category – A
b)100 amps. Category – A
Supplying & erection of 6 amps. to 32 amps. rating, 10KA breaking capacity, 240 volts, ‘C’ curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required complete in all respect as per satisfaction of Engineer-in-charge. a) Single pole. Category – A
Supplying and erection of 40/50/63 amps rating, 10KA breaking capacity, 240 volts, ‘C’ curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required complete in all respect as per satisfaction of Engineer-in-charge. a). Double pole. Cat. A.
Supplying and fixing following rating, four pole (single phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 millampers in the existing MCB DB complete with connections, testing and commissioning etc. as required complete in all respect as per satisfaction of Engineer-in-charge. a) 63 Amps. Cat-A.
Supplying and fixing of following way triple pole and neutral sheet steel MCB distribution board, 415 volts, on surface / recess, with provision for 4-pole MCB / isolator / RCCB / RCBO as incomer and SP MCBs as outgoing, complete with tinned copper bus-bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required complete in all respect as per satisfaction of Engineer-in-charge. a) Single door-4 way (8+12), horizontal type.
Earthing with copper earth plate 600mm x 600mm x 3mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and water pipe etc. (but without charcoal or coke and salt) complete as required complete in all respect as per satisfaction of Engineer-in-charge.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required complete in all respect as per satisfaction of Engineer-in-charge.
Supplying and laying 8 SWG copper wire at 0.50 Rmt. below ground level for earth electrode conductor, including soldering etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
Providing and fixing 25mmx5mm copper strip on surface or in recess for earth connections etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
Providing, laying & fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size complete in all respect as per satisfaction of Engineer-in-charge. a)Armoured cable 50 Sqmm (3.5 core).
Supplying & fixing of bulk head fitting of all sizes & shapes, containing one No. thread type LED lamp holder (s), complete with all accessories but including LED lamp including making connections, testing etc. as required complete in all respect as per satisfaction of Engineer-in-charge. a). Bulk head fitting, LED type (Category-A)
Supplying and erection of Baton integrated LED channel integral sleek extruded polycarbonate LED channel with white acrylic cover of BCLSB 18 WH including making all necessary connection etc. as required complete in all respect as per satisfaction of Engineer-in-charge (Bajaj make).
Providing, installation, testing and commissioning of electric elevator traction ( 10 passenger capacity) to relevant standard to be erected with following specification with two year free AMC from the date of handling over the lift complete in all respect as per satisfaction of Engineer-in-Charge (Kone / Schindler /Otis / Fugitek make)
CIVIL REQUIREMENTS : Shaft walls – concrete, Clear inside shaft (required) – 1804mm width x 1700mm depth, Clear inside shafts – 2200mm width x 2400mm depth, Pit depth – 1500mm, Minimum floor to floor height (required ) – 2600mm, Travel Height – 10500 mm, Head room height – 4200mm, Lintel Height (required) – 2180mm from finished floor level, Locable storage room (required) – 250 Sq.feet, Stilt -5- area under roof (required) – 200 Sq.feet and spreader channel if required at site for installation and preparation of lift well.
CAPACITY : Number of person 10, rated load 680 kg SPEED : 1.0 m/s LOCATION OF MAHCINE ROOM : Permanent magnet synchronous Electric traction gearless motor to be hoisted on guide rail within the elevator Hoistway.
ELEVATOR SPECIFICATIONS : Number of Stops – 4, Number of access sides – 1, Floor designations- G,1,2,3, Drive System – Alternating current voltage Frequency (ACVF), Type of Controller – Full collective control –Simplex, Door Width – 800mm, Door Height – 2000mm, rated output motor – 4.6kw. TRAVEL : Approximately 9.9 metres (Ground floor to 3rd floor). SERVING : 4 floor 4 stops 4 levels 4 opening ( all on the same side). HOISTWAY AVAILABLE : (2400mm wide x 2700mm deep) Clear Dimensions. CAR SIZE : 1200mm (W) x 1400mm (D) x 2139 mm (H). PIT DEPTH REQUIRED : 1500mm below the finished floor level of first landing. HEADROOM REQUIRED : 4000mm beyond inished floor level of last landing. CAR DESIGN : Car walls finish in SS leather LED spot in ceiling, Car doors finish in stainless steel leather 304, Car door in st/steel leather, Granite flooring finish in black sea, Deco ceiling finish in stainless steel mirror 304 and Full height mirror on rear car panel. CAR ENTRANCE : Centre opening automatic doors in stainless steel in hairline finish with a clear opening 800mm wide x 2000mm high.
HOISTWAY ENTRANCE : Centre opening automatic door in stainless steel in hairline finish with provision of emergency key opening at all landing with a clear opening 800mm wide x 2000mm high. DOOR OPERATION : Fully automatic landing doors in Stainless steel leather 304 finish. Door opening Direction – Centre. CAR OPERATING PANEL : Stylish, touch sensitive glass panel, Door panel / close and alarm buttons, Visual call confirmation, Car position indicator, Pre-announcing arrows for collective controls, 16 segment display. LANDING DOORS : Fully automatic landing doors in stainless steel Leather 304 finish.
Dhiman Elect-
sanjay kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .