Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹53.7 L+₹8.6 L (19.2%)Rejected-Finance OPP KIRYAPA PARK NATIONAL HIGHWAY ROAD BARAMULLA J K 193101 | NA | NA | 193101 | L2 | Rejected-Finance Not Being L1 |
Tender Value
₹41.7 L
EMD Value
₹83,328
Closing Date
2 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS
PROVN OF 300 KVA TRANSFORMER VOLTAGE STABILIZER AND ALLIED SERVICES AT 519 ASC BN AT PATTAN UNDER GE 969 EWS
2023_MES_624940_1
CWEK-40/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 969 EWS
Class D Categories b i and b ii
6 documents required · 6 mandatory
₹500
GE 969 EWS
₹83,328
HQ 133 WORKS ENGRS
2 Feb 2024
25 Oct 2023
11 Dec 2023
25 Oct 2023
2 Dec 2023
13 Nov 2023
25 Oct 2023 - 1 Nov 2023
2 Nov 2023
Amount
Supply, Installation, Commissioning of Distribution transformer of capacity 315 KVA step down outdoor type Copper Wounded ONAN Cooling 11/0.433 KV (at no load) AC 3 Phase 50 Hz on secondary side double wounded oil immersed naturally all air cooled with external tubes/radiator, delta connected as on primary and star connected with neutral brought on secondary side and having tapping at (+) 2.5%, (+) 5%, (+) 7.5% to be changed by hand operated OFF LOAD top changing gear. The maximum temperature rise should not exceed 45 degree centigrade in oil and 50 degree centigrade in HV/LV winding when measured by the resistance method after continuous full load run in ambient temprature the transformer shall confirming to IS 1180 Part-I and comprising of following accessories :-
(a) 01 No Cable end box on HV side consisting of with 03 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for XLPE cable 3 Core 120 Sqmm including cable joint complete adopter box (b) 01 No cable end box on LV secondary side consisting of 04 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for XLPE cable 3.5 Core 185 Sqmm including cable joint complete adopter box (c) Oil conservator with filter type drain valve and oil level gauge. (d) Dehydrating breather with first filling of dehydrating agent. (e) Explosive vent. (f) Thermometer Pocket. (g) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI Strip. (h) One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with maximum temprature indicator and re-setting device to maximum temprature including needle of temprature gauge max reading panted terminal.
(j) Rating plate with terminal plate. (k) Oil drain filter valve. (l) Oil filling hole on top cover with plug. (m) Air release valve/plug. (n) 4 Nos plain solid cast steel detachable rollers. (o) Extra bushing for neutral out side the cable box providing independent earthing for neutral. (p) First fill of transformer oil confirming to relevant IS and tested upto 60KV dielectric strength.
M&L for providing platform for transformer of size 3mx3mx1.2m height from GL including excavation in trenches PCC 1:5:10 type E2 for foundation, brick work in cm 1:6, PCC 1:2:4 and width of brick wall 35cm type B1 in copping plaster 10mm thick in cm 1:6 on brick/complete surface PCC 1:4:8 type B1 sub base 75mm thick as in floor, PCC 1:2:4 type B1 100mm thick floor using extra cement, returning filling and removal of surplus soil, chain link fencing 1.8m high made out of 4mm dia GI wire 150x100mm mesh, MS work angle iron 50x50x6mm as fencing post in embedded in PCC work at 2 mtr interval each side as approved 1 No steel gate (3.5m clear) span with locking arrangement made out of 15mm dia MS rod with spacing 150mm & 50x50x6mm angle iron frame painting with 2 coats of aluminium paint over a coat of red oxide primer and 3 coats of white washing on cement work including ISMC 100 channel 2 Nos for fixing transformer complete all as specified and as directed by Engr-in-Charge.
Supply, laying UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 120 Sqmm, ISI marked complete all as specified and as directed by Engr-in-Charge.
Supply, laying UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cables 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core, ISI marked complete all as specified and as directed by Engr-in-Charge.
Supply, laying UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cables 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core, ISI marked complete all as specified and as directed by Engr-in-Charge.
Supply, laying UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cables 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core, ISI marked complete all as specified and as directed by Engr-in-Charge.
Supply, laying UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cables 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core, ISI marked complete all as specified and as directed by Engr-in-Charge.
Supply, laying UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cables 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core, ISI marked complete all as specified and as directed by Engr-in-Charge.
Supply, laying UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cables 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 2 Core, ISI marked complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level complete all as specified and directed by Engr-in-charge.
All as per item No 10 above but exceeding 1.5 Mtr and not exceeding 3Mtr depth complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engr-in-charge.
Removing surplus exacavated soil material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed by Engr-in-charge.
Supply and filling dry river sand in trenches including spreading for cushioning of LT UG cablec and punning down complete all as speified and directed by Engr-in-charge. Note : Punned down thickness shall be measured and paid complete all as specified and as directed by Engr-in-Charge.
M&L for well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as speified and directed by Engr-in-charge.
S&F Steel tubular swaged poles complete with MS base plate Continuously welded to pole, finial taper plug, bolts, nuts & screws as specified type 410 SP- 55 (11 metres long ) includind two coat of black bituminous paint internally throughout and externally upto embedded portion and including applying two coats of synthetic enamel paint over a coat of red oxide primer with black and white strip of 30 cm each upto 1.5 m height and two coats of aluminium paint over a coat of red oxide primer externally on remaining exposed surface aftereraction in position incl prepration of surface, complete all as specified and directed.( earth work ,PCC and copping will be measured and paid for separately under respective item) complete all as specified and as directed by Engr-in-Charge.
M&L for Switch air break, gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps 11000 volts (12 Insulator) alongwith fuse system complete all as specified and as directed by Engr-in-Charge.
M&L for Lighting arresters expulsion type complete with all fittings transmission class, discharge capacity 65KA suitable for 11000 volts complete all as specified and as directed by Engr-in-Charge.
Material and labour of danger notice plate of 1.6 mm thick as per IS : 2551 of 1982 mild steel sheets vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and inclusive fixed with MS flat clamps 25x3mm 2Nos , bolts , and nuts for HT 11KV 25x20cm complete all as specified and as directed by Engr-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and as directed by Engr-in-Charge.
S & F cross arms bracing supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome, one under coat and one finishing coat of aluminum paint complete all as specified and as directed by Engr-in-Charge.
M & L for plain cement concrete 1:4:8 type D2 using 40 mm graded aggregate for foundation fillings and mass conctere complete all as specified and as directed by Engr-in-Charge.
M & for cement concrete 1:2:4 type B1, using 20 mm graded aggregate as in coping of poles smooth finishing without using extra cement complete all as specified and as directed by Engr-in-Charge.
M & L for plain cement concrete 1:3:6 type C2 using 40 mm graded aggregate for foundation fillings and mass conctere complete all as specified and as directed by Engr-in-Charge.
M&L for earthing with galvanised iron earth plate electrode 600mm x600mmx 6mm thick burried directly in ground (Eart pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level, inclusive galvanised iron strip 32x6mm as earth strip connected to earth plate electrode by means of bolts,nuts,check nuts and washers,earth wire protected with and including 40 mm bore light grade ISI marked GI pipe upto 7.5 meters long all as shown in electrical plate no 5 of MES schedule part-1,with and including PCC 1:2:4 type B1 pit with cover of RCC 1:2:4 type B1,reinforced with welded steel wire fabric not less than 4 kg per sqmtr with handle and angle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked,GI funnel with GI mesh,filling with mixture of common salt and charcoal,necessary excavation, refilling, removing away spoil and earth work in any type of soil, including test point, testing and commissioning complete all as specified and as directed by Engr-in-Charge.
Supply and laying GI pipe 80 mm bore light grade ISI marked with fitting for cable protection complete all as specified and as directed by Engr-in-Charge.
Supply, install, testing and commissioning of LT feeder piller box outdoor type made out of 3.15 mm thick CRCA sheet and MS angle iron frame with weather proof canopy, mounted on PCC pedestal, cubical type, front and rear side openable, compartment type with hinged door ligting lugs 2 Nos, earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc and passivated nut, bolts spring and washers and locking arrangement for each compartment, provision of air vent, dust and vermin proof, provision of cable alley with 1000 amps rated aluminium bus bar having 1100 volts grade sleaving and internal connection should be provided with aluminium strips of suitable size and to accommodate and including the following MCCBS duly painted with 2 coats powder coating over a coat of anticorrosive red oxide primer should accomodate the following accessories.
Supply, install, testing and commissioning of LT feeder piller box outdoor type made out of 3.15 mm thick CRCA sheet and MS angle iron frame with weather proof canopy, mounted on PCC pedestal, cubical type, front and rear side openable, compartment type with hinged door ligting lugs 2 Nos, earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc and passivated nut, bolts spring and washers and locking arrangement for each compartment, provision of air vent, dust and vermin proof, provision of cable alley with 400 amps rated aluminium bus bar having 1100 volts grade sleaving and internal connection should be provided with aluminium strips of suitable size and to accommodate and including the following MCCBS duly painted with 2 coats powder coating over a coat of anticorrosive red oxide primer should accomodate the following accessories.
Supply, install, testing and commissioning of LT feeder piller box outdoor type made out of 3.15 mm thick CRCA sheet and MS angle iron frame with weather proof canopy, mounted on PCC pedestal, cubical type, front and rear side openable, compartment type with hinged door ligting lugs 2 Nos, earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc and passivated nut, bolts spring and washers and locking arrangement for each compartment, provision of air vent, dust and vermin proof, provision of cable alley with 400 amps rated aluminium bus bar having 1100 volts grade sleaving and internal connection should be provided with aluminium strips of suitable size and to accommodate and including the following MCCBS duly painted with 2 coats powder coating over a coat of anticorrosive red oxide primer should accomodate the following accessories.
Supply and Installation Voltage stabilizer Copper Wound for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 300 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 300 KVA complete all as specified and as directed by Engr-in-Charge.
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc complete all as specified and as directed by Engr-in-Charge.
Supply and fix HT overhead line of 11KV on 11 meter steel poles with continuous GI earth wire, and ACSRconductor of sizes 3 of 6/1x2.59 mm complete all as specified and as directed by Engr-in-Charge.
S & F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade HT over head line and including taking down old complete all as specified and as directed by Engr-in-Charge.
S & F single Disc type insulator, porcelain, vitreous 145 mm high and 225 mm dia ball and socket type, brown, assembly for tension with tension clamps for conductors, 11000 volts complete all as specified and as directed including taking down old unserviceable one complete all as specified and as directed by Engr-in-Charge.
M&L for construction of shed for Voltage Stabilizer/Transformer including steps, plinth protection, cable duct of size 4mtr(L) x 3mtr (W) x 3 mtr (H) complete as per following (a) Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sq m on plan aqnd n exc 1.5m in depth and getting out in hard/dense soil - Cum - 2.5 (b) M&L for PCC 1:4:8 type D-2 (40mm graded agg) is in foundation filling and mass concrete - Cum - 0.85 (c) M&L for brick work in cement mortar 1:6 straight or curved on plan exc 6 m mean radius - Cum - 5.6 (d) Rendering 15mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces with including finishing the surface even and smooth using extra cement - Sqm - 15
(e) Returning filliing in in layers n exc 25 cm thick including spreading, levelling, watering and well ramming - Cum - 0.35 (f) Soil obtained from excavation filling under floors or in foundations including watering and consolidation except soil - Cum - 6.3 (g) M&L hardcore of gauge n exc .63mm, deposited, spread and levelled in ayers n exc 15 cm thick, watered and rammed to a true surface with broken stone or boulders-Cum-0.96 (h) 75mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate as in sub floors, sub bases, floor and paving etc - Sqm - 6.5 (j) 100mm thick cement concrete type B-2, 1:2:4(40mm graded aggregate) as in sub floors, sub bases, floor and paving etc - Sqm - 9.0 (k) S&F steel work in tubular trusses including, special shaped washer etc. complete unsing ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 - Kg - 315 (l) S&F mild steel work (misc) as in hold fast, cleat, wall ties and similar articles conf to Fe-290 Ge E-165 - Kg - 10
(m) S&F pre-painted galvaturme aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in wall, fixed with self tapping screws as specified - Sqm - 17 (n) - ditto - all as per item No (m) above but plain sheet as in ridge - Sqm - 2.15 (o) S&F welded steel wire fabric nexc 4 kg/sqm complete to steel members-Kg - 35 (p) M&L for preparation of new steel and iron surfaces of any discription applying two coat of synthetic enamel paint over a coat of red oxide paint - Sqm - 14 (q) M&L for preparing new surfaces plastered of walls and applying two coat of cement base paint - Sqm - 15 (r) S&F Galvanised 2 strand steel barbed wire 2.24mm dia barbed wire with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (Each line wire to be measured) -Per 100 RM - 0.6 complete all as specified and as directed by Engr-in-Charge.
M/S GHULAM RASOOL LONE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .