Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC KHATRA BANKURA | KHATRA | BANKURA | WEST BENGAL | L1 | Accepted-AOC Accepted | |
| 2 | L2₹2.2 L+₹17,823.17 (9.02%)Rejected-Finance NUTANCHATI BHOWMIK GATE BANKURA | BANKURA | L2 | Rejected-Finance Rejected | |
| 3 | L3₹2.2 L+₹19,471.43 (9.85%)Rejected-Finance AT NUTANCHATI P O BANKURA DIST BANKURA PIN 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹2.2 L+₹21,162.59 (10.7%)Rejected-Finance INDARAGORA BANKURA W B | BANKURA | BANKURA | WEST BENGAL | L4 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹5,200
Closing Date
16 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer, BMSD, PHE Dte
Office of the Assistant Engineer. Bankura Mechanical Sub-Division. P.H.E. Dte. PHE Complex, Ailakundi, PO Kenduadihi, Bankura 722102.
Withdrawing repairing and lowering of 1 nos 40HP HL submersible pump set at intake well and rectification of cable line and river bed pump motor set at Chabra of Onda water supply scheme under Bankura Mechanical Division,P.H.E. Dte.
2022_PHED_400764_1
WBPHED/AE/BMSD/NIeT- 3 OF 2022-2023
Open Tender
MECHANICAL
Item Rate
15 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,200
Yes
28 Oct 2022
7 Sept 2022
19 Sept 2022
7 Sept 2022
16 Sept 2022
7 Sept 2022
Amount
Withdrawing of the HL 40 H.P capacity submersible pump and motor set along with column pipe after disconnection of pipe line and power line by help of chain pulley arrangement and manual labour to complete the job as per direction of EIC.
Carrying charges of withdrawn pump motor set from Intake well platform to workshop at Bankura town for repairing including loading unloading charges.
i)Dismantling the damaged 40 HP pump motor set part by part with cleaning & through checking
a) For pump
b) For Motor
Supply the following spares as per sample :-
ii) For Pump
a) Pump casing bush (GM)
b) Shaft sleeve bush (SS)
c) 8mm stud (8mm x 33mm)
d) Pump shaft SS410 22 mmX900mm as per sample
iii) For Motors
a) Rotor bush (GM)
b) Rotor sleeve (SS)
c) 10mm nut for upper & lower casing
d) Motor sand guard (Rubber)
f) 16sq. mm. 3core copper water proof submersible cable (Finolex)
h) Motor water seal
iv) Rewinding the 40 HP submersible motor by supplying suitable gauge copper wire dual coated class F insulation as per existing gauge as per direction of E.I.C.(Rate is after deduction of old cu coil cost)
v) Reassembling charges for pump motor by old spares & new spares of Sl. No. 3 ( i & ii) with through cleaning & overhauling complete
i) For pump
ii) For motor
vi) Painting the pump motor sets with 2(two) coats by approved anticorrosive paint after through scraping the body of pump & motor all complete as per direction of E.I.C.
vii) Carrying the repaired pump motor sets from workshop to Chabra Intake including loading & unloading at both ends
Supply and delivery of the following materials at site.
MS ERW black pipe conforming to IS 1239 Part-I (2004)
a) 150mm dia
MS Tee branch welded ERW (class B )
a) 150mm dia
MS slipon weldable flange ( type- table E)
a) 150mm dia
MS Blind flange ( type- table E)
a) 150mm dia
GI pipe medium (TATA make ) 50mm dia
Rubber gasket
a) 150mm dia
MS nut bolt IS mark 5/8''x 2.5'' (56nos x1 set )
Nylon rope 25 mm
Glycerin filled Burdon tube pressure gauge with syphon and stop cock dial SS, 3'' range 0-10kg/cm2
Contineous welding charges for making flanged end pipe with 2 nos flanges and fittings (Tee) .This includes all charges of hiring machine and tools etc as required.( Total running length of contineous welding 150 mm dia 5 nos pipe + Tee 1 no [email protected]=10602
Lowering of repaired submersible pump motor set along with supplied column pipe and fittings in item no (4) stage by stage by means of chain pulley block arrangement and making safety arrangement by fitting fixing of nylon rope and making power line and supply main line connection, interconnection with the delivery line all complete as per direction of E.I.C.
Rectification of LL installation
Carrying charges of 400 mtr 10 sq mm Al.Ar.cable, 100A porceline fuse grip 3 nos from office store to chabra ,onda W/S scheme including loading unloading charges.
Laying of 10 sq mm 3 core Al.Ar. Cable along delivery pipe line including binding with GI wire from MCC panel to 2 nos river bed tubewell seperately.
Laying of 10 sq mm 3 core Al.Ar. Cable along delivery pipe line after shifting sand and earth including binding with GI wire and refilling sand at river bed tubewell .(2 nos TW)
Withdrawing the 3 HP Submersible Pump Motor set from river bed tubewell after disconnection of Power line and pipe line as per direction of EIC. For river bed TW-2 &5
Due to shifting of sand around casing pipe charges for lowering the height of the casing & column pipe by Cutting MS Casing pipe 200 mm and column pipe 80mm to its requisite length. This includes hiring charges of gas cutter and tools and tackles at river bed. For TW no 2
Lowering of the submersible pump and motor set along with column pipe and fitting fixing well top cover on the Tube with nut bolt , washer gasket kit with sealing the tube well and power line connection as per direction of EIC. For TW-2&5.
Finishing the end of the 10 sq mm 3 core Al Ar cable by crimping method by supplying all necessary materials.
Interconnection the tubewell and existing rising main (150mm) by supplied all materials as per direction.
Fitting fixing 100A /415V porcelinerewireable fuse grip on wall with supply and fixing wooden plank at back as per direction.
Supply and fixing LED tube light fittings 28W on wall and making power line connection.Make:- Philips/as per approved vender list of phed. At Intake well HL pump room.
Rectification of 5 nos LED bracket by supplying and fixing 9W LED lamp at Intake bridge.
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Add: 18% GST
Add: 1% Cess
PRADIP KUMAR DHABAL
SUTRADHAR TRADERS
M/S NABIN GOPAL SENGUPTA
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .