| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC C 125 A KUNWAR SINGH NAGAR NANGLOI NEW DELHI 110041 | NEW DELHI | WEST DELHI | DELHI | 110041 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹14.4 L+₹89,588 (6.63%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹15.5 L+₹2.0 L (14.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹19.9 L+₹6.4 L (47.0%)Rejected-Finance 0 CIVIL LINES TETARI BAZAR TETARI BAZAR NAUGARH SIDDHARTHNAGAR UTTAR PRADESH 272207 | SIDDHARTH NAGAR | UTTAR PRADESH | 272207 | L4 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | M/s A.K Construction L2 | M/S Satyam Associates L1 | PANDEY TRADERS L4 | M/S DEEKSHA CONSTRUCTION L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&O for periodical maintenance / servicing of DG set consisting of normal repairs such as tightening of nut bolts, greasing, checking of lube oil level , fuel tank, fuel pipes, water / coolent level in radiator,cleanness of air filter, condition of hose ,V belts , battery connections / checking of battery terminals , level of distilled water in battery and checking of all other visual parts of DG set including routine cleaning of dust with vacuum cleaner etc ( once a week or as required and directed by Engr-in-Charge / JE.) (a ) For DG Set 320 KVA, Make;- KIRLOSKAR
(i) The maintenance cost of DG Set for month shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts etc.
(ii) M & L for replacement of spares parts and oil will be measured and paid under relevant items of schedule ‘A’. | 6 | Per month | 3,000 ₹18,000 | 3,000 ₹18,000 | 2,000 ₹12,000 Lowest | 2,600 ₹15,600 |
| 2.00 | All as per item above but DG Set 100 KVA, Make - CROMPTON GREAVES | 6 | Per month | 1,000 ₹6,000 | 700 ₹4,200 Lowest | 1,500 ₹9,000 | 800 ₹4,800 |
| 3.00 | All as per item above but DG Set 75 KVA, Make - KIRLOSKAR | 6 | Per month | 750 ₹4,500 | 500 ₹3,000 Lowest | 1,200 ₹7,200 | 950 ₹5,700 |
| 4.00 | All as per item above but DG Set 45 KVA, Make - KIRLOSKAR | 6 | Per month | 650 ₹3,900 | 500 ₹3,000 Lowest | 1,000 ₹6,000 | 850 ₹5,100 |
| 5.00 | Supply and fix in repair following spare parts of DG set 320 KVA , Make KIRLOSKAR. (a) Diesel Filter ( fuel filter) | 1 | Set of 2 | 850 ₹850 | 3,000 ₹3,000 | 5,000 ₹5,000 | 700 ₹700 Lowest |
| 6.00 | (b) Mobile filter (lube oil filter) | 1 | Each | 150 ₹150 Lowest | 1,500 ₹1,500 | 1,200 ₹1,200 | 200 ₹200 |
| 7.00 | Air filter (primery & safety element) including air cleaner hose with T bolt and clamp. | 2 | Each | 160 ₹320 | 3,000 ₹6,000 | 2,500 ₹5,000 | 130 ₹260 Lowest |
| 8.00 | V Belt for fan drive. | 2 | Each | 110 ₹220 Lowest | 200 ₹400 | 800 ₹1,600 | 150 ₹300 |
| 9.00 | Starter ring | 1 | Each | 130 ₹130 Lowest | 400 ₹400 | 1,200 ₹1,200 | 160 ₹160 |
| 10.00 | Fuel pipe with copper washer and banjo bolt ( fuel tank to fuel filter) | 1 | Each Set | 450 ₹450 | 300 ₹300 Lowest | 500 ₹500 | 500 ₹500 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
19 Jun 2025, 6:00 pmClosed
GE AF Gorakhpur
GE AF Gorakhpur
REPAIR/ MAINT OF DG SET, STREET LIGHT AND MISC EM ITEMS AND FAN/GEYSER AT 4 AFSB UNDER GE AF GORAKHPUR
2025_MES_710128_1
9313/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF Gorakhpur
Class D cat b i
8 documents required · 8 mandatory
₹500
GE AF Gorakhpur
₹48,000
Yes
8 Aug 2025
24 May 2025
21 Jun 2025
24 May 2025
19 Jun 2025
6 Jun 2025
24 May 2025 - 30 May 2025
Amount
M&O for periodical maintenance / servicing of DG set consisting of normal repairs such as tightening of nut bolts, greasing, checking of lube oil level , fuel tank, fuel pipes, water / coolent level in radiator,cleanness of air filter, condition of hose ,V belts , battery connections / checking of battery terminals , level of distilled water in battery and checking of all other visual parts of DG set including routine cleaning of dust with vacuum cleaner etc ( once a week or as required and directed by Engr-in-Charge / JE.) (a ) For DG Set 320 KVA, Make;- KIRLOSKAR (i) The maintenance cost of DG Set for month shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts etc. (ii) M & L for replacement of spares parts and oil will be measured and paid under relevant items of schedule ‘A’.
All as per item above but DG Set 100 KVA, Make - CROMPTON GREAVES
All as per item above but DG Set 75 KVA, Make - KIRLOSKAR
All as per item above but DG Set 45 KVA, Make - KIRLOSKAR
Supply and fix in repair following spare parts of DG set 320 KVA , Make KIRLOSKAR. (a) Diesel Filter ( fuel filter)
(b) Mobile filter (lube oil filter)
Air filter (primery & safety element) including air cleaner hose with T bolt and clamp.
V Belt for fan drive.
Starter ring
Fuel pipe with copper washer and banjo bolt ( fuel tank to fuel filter)
Fuel pipe with copper washer and banjo bolt ( fuel filter to pump inlet)
Drain cock with adoptor.
Lube oil pressure sendor ( sensor + switch)
Water pump belt - V section
Supply and fix in repair following spare parts of DG Set 100 KVA, Make - CROMPTON GREAVES (a) Diesel Filter ( fuel filter)
(b) Mobile filter (lube oil filter)
Air filter (primery & safety element) including air cleaner hose with T bolt and clamp.
Breather hose with clamp as per existing size and sample
V Belt for fan drive.
Starter ring
Fuel pipe with copper washer and banjo bolt ( fuel tank to fuel filter)
Fuel pipe with copper washer and banjo bolt ( fuel filter to pump inlet)
Drain cock with adoptor.
Radiator drain cock with plug and adoptor.
Supply and fix in repair following spare parts of DG Set 75 KVA, Make - KIRLOSKAR (a ) Diesel Filter ( fuel filter)
(a ) Mobile filter (lube oil filter)
Air filter (primery & safety element) including air cleaner hose with T bolt and clamp.
Breather hose with clamp as per existing size and sample
O ring for breather plate.
V Belt for fan drive.
Starter ring
Fuel pipe with copper washer and banjo bolt ( fuel tank to fuel filter)
Drain cock with adoptor.
Water pump belt - V section
Supply and fix in repair following spare parts of DG Set 45 KVA, Make - KIRLOSKAR (a) Diesel Filter ( fuel filter)
Mobile filter (lube oil filter)
Air filter (primery & safety element) including air cleaner hose with T bolt and clamp.
Breather hose with clamp as per existing size and sample
O ring for breather plate.
V Belt for fan drive.
Starter ring
Fuel pipe with copper washer and banjo bolt ( fuel tank to fuel filter)
Fuel pipe with copper washer and banjo bolt ( fuel filter to pump inlet)
Radiator drain cock with plug and adoptor.
Supplying, installation, testing & commissioning in replacement response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. Make : Firejeet.
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including replacement of fuel tank lid by new one for DG set of capacity 320 KVA DG set
All as per item No.50 above but DG Set 100 KVA, Make - CROMPTON GREAVES
All as per item No.50 above but DG Set 75 KVA, Make - KIRLOSKAR
All as per item No.50 above but DG Set 45 KVA, Make - KIRLOSKAR
Taking down the defective water pump from DG set of any type and capacity and replace with new one for DG set of cap 45 KVA to 320 KVA all as directed .
M&L for Repair to Radiator assy by disconnecting the radiator from engine frame and servicing/cleaning with acid and brazing where required to stop leaking tubes/joints etc. cleaning fins and re-fixing the same for DG set 45 KVA to 320 KVA all as directed.
Supplying and filling coolant as recommended by manufacturer in DG sets.
Supply in sump / topping up engine oil, multi grade 20w/40 in engine or replacement of engine oil for DG SETS .Make: Indian oil / Hindustan petroleum / Castrol.
Supplying & laying in replacement of 2 core x1.5 sqmm FRLS PVC insulated unarmoured cable , 600 / 1100V rated with annealed solid copper conductor, through and including PVC conduit of suitable size , complete all as specified & required at site
Supplying & laying in replacement of 6 core x2.5 sqmm fire survival armoured cable, 600/1100V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required, rate quotted should be inclusive of earth work required for laying the cable.
M & L in repairs GI pipe 20 mm bore light grade to be fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
M & L in repairs GI pipe 40 mm bore light grade to befixed on pole/under road/on wall for protection of cable/earth strip including all fittings complete all as specified and directed.
Taking down existing street light fitting/flood light/post top lantern of any type and make & capacity.
Supply and fix roadway luminaire LED light fittings of 60 watts and including necessary electric connection with 2.5 Sqmm twin core Copper conductor unarmoured cable, complete all as specified and directed. Make Bajaj /CG /Havells.
All as per item No. 63 above but of 72 watts .
All as per item No. 63 above but of 90 watts .
All as per item No. 630 above but of 120 watts
Supply and fix LED Flood light 60 W IP 66 including necessary electric connection with twin core twisted flexible copper conductor cable of suitable size .Make Bajaj /CG /Havells.
All as per item No. 67 above but of 120 watts
All as per item No. 67 above but of 200 watts
Supply and fix LED post top lantern 25 W made in cast aluminium spigot housing with decorative opel polycarbonate diffuser and IP 65 protection including necessary electric connection with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make Bajaj /CG /Havells.
All as per item No. 66 above but of 35/40 watts
S & F bracket made with GI tube light grade (not less than 1.2 RM) in length of 32 mm bore size and fixed to the LT pole with the help of two Nos FI Clamps of size 50X6 mm nut bolt and washers,complete all as specified and directed
All as per item No. 68 above but of 40 mm bore size.
Taking down existing U/S wiring of aviation obstruction light complete from aviation obstruction light to MCB DB ( Approx 50 RM ) .
Matrial & Labour for sub main wiring using 4 sqmm two single core PVC insulated sheathed copper conductor and one run of single core copper cable 1.5 sq mm used as earth wire in PVC conduit of size not less than 20 mm complete all as specified and directed.
Supply and fix integral LED aviation light comprising of aluminium housing with polycarbonate enclosure including necessary electric connection with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make Bajaj Cat part No. BGAV 302 LED or equivalent PS.
Supply laying fixing or passing through pipe 1100 Voltage grade heavy duty unarmoured weather proof flat cable with PVC insulated and sheathed aluminium conductor comfirming to relevent IS size 4 sqmm 2 core and connecting to system complete all as specified and directed.
Supplying, installation, testing & commissioning in replacement power supply PCB for main FACP of make Simplex as per existing sample and recommended by OEM and making FACP functional complete all as specified and directed.
Taking down u/s steel tubular pole due to corrosion effect .
Supply, erecting and fixing in true vertical position steel tubular swaged pole 9 Mtr long type (410 SP -22) conforming to IS 2713 part I & III - 1980 complete with cast iron base plate, pole cap, mild steel, bolts, nuts and screws, welded and reduced section and longitudinal weld seam throughtout entire length of pole including two coats of black bituminous paint throughtout internally and externally upto planting depth and remaining exterior portion of pole with two coats of aluminium paint over a coat of red oxide primer complete including transporting the poles to plating & providing three bends/strap with paint red signal/post office colour 300 mm apart from plinth block & numbering of poles complete all as specified and directed and including foundation with the following : (a) Excavation in post holes in any type of soil , return filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtrs from the starting point. (b) PCC (1:3:6 ) type C2 using 40 mm graded stone aggregate as in foundation. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping , including necessary form work.
Supply and fix in replacement FRP , hot press moulded SMC pole box 295X255X120 mm comprising of 100 Ams aluminium bus bar 4 strips ( IP 55 protection ) with one MCB SP 6 Ams to be fixed inside the box and box will be clamped bottom of the pole with FI clamps (duly painted ) nut bolt washers of required size.Make - SINTEX ,Model GSJB-2520 or any other sample approved by GE.
Preparation of old painted steel surface and painting of steel tubular pole upto 09 RM long applying two coats of aluminium paint on complete poles including cross arms and writing of numbers on pole with black paint in 40 mm font size of letters including surface dressing all around the poles approximetely 01 Sq Mtr area complete all as specified and directed .
Painting of junction box of poles with two coat of synthetic enamelled paint complete all as specified and directed all as directed at site.
Preparation of old painted steel surface and painting of LT panel board / feeder pillar box including scratching the existing burnt and rusted paint and applying newly two coats of synthetic enamelled paint to match the existing upto smooth surface of panels complete all as specified and directed by Engr-in-Charge.
S & F in repair of ACB 4 pole 415 Volt, 50 Hz, 630 Amps ,manual drawout type with microprocessor release all as specified and directed.
S & F in repair of MCCB 4 pole 415 Volt, 50 Hz,125 Amps with breaking capacity 16 KA fixed type all as specified and directed.
S & F in repairt of MCCB 4 pole 415 Volt, 50 Hz,100 Amps with breaking capacity 16 KA fixed type all as specified and directed.
S & F in repair of MCCB 4 pole 415 Volt, 50 Hz,63 Amps with breaking capacity 16 KA fixed type all as specified and directed.
S & F in repair on load changeover switch with sheet steel enclosure, I-O-II 3 phase & neutral,415 V, 50 Hz, 400 A complete all as specified and directed. Make HPL / Havells.
S & F in repair on load changeover switch with sheet steel enclosure,I-O-II 3 phase & neutral,415 V, 50 Hz, 200 A complete all as specified and directed. Make HPL / Havells.
S & F in repair HRC fuse DIN type 125 A, 80KA, 500V.
Supplying, installation, testing & commissioning in replacement Intelligent Addressable Multi-Sensor (Optical Smoke + Heat) detector with base complete all as specified and directed.Make- Simplex.
Periodical maintenance of fire alarm and detection system located at Bldg No. P/63 , P 78 and P /90 of 4 AFSB Varanasi. Scope of work :- (a) Periodical maintenance would including cleaning of all fire Multi-Sensor (Optical Smoke + Heat) detector with air blower checking of parameters of main FACP , Active Repeater Panel ( Local FACP),MCP , response indicator , Addressable Notification Devices (Hooter with Strobe), Supervised Short-Circuit Isolator,SPDT contact based control module, wiring and all other accessories weekly as per pre planned schedule & shall deemed to comprises of cost of trained labour employed for the purpose, T&P used and other petty items such as cotton waste etc. (b) Checking electrical parameter /notifications in FACP observed / report for the same have to submit to Engr-in Charge /JE (E/M) on weekly basis.
Supplying, installation, testing & commissioning in replacement of Intelligent Addressable Double Action Indoor Application Manual Pull Stations / Manual Call Points suitable for wall/column mounting. Make:- Simplex
Supplying, installation, testing & commissioning in replacement of Intelligent Addressable, Supervised Short-Circuit Isolator. The Isolator Monitor Module shall have operating temperature range from 0°C to 49°C and a humidity tolerance of up to 90% RH, Non-Condensing. Make:- Simplex.
Supply and fix in replacement battery of capacity 150 Ah , 12 V suitable for DG sets
Supply and fix in replacement battery of capacity 110 Ah , 12 V suitable for DG sets
Supply and filling distilled water in battery .
M&L for replacement of brass battery terminal suitable for lead acid battery 12 V any AH .
Supplying, installation, testing & commissioning in replacement of Addressable Notification Devices (Hooter with Strobe). Hooter with Strobe unit shall sit directly on addressable NAC (Notification Appliance Circuit) of FACP, fully supervised and powered from FACP. Make:- Simplex.
M &L for Removing the fuel injection pump (FIP) from DG set cap 45 to 320 KVA and carry out servicing and calibration from authorised maker's work shop including replacement of injectors, nozzles, etc. and refitting the same for smooth and efficient functioning all as directed. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set.
Taking down defective self starter and supply and fix in replacement self starter for 75 /100KVA DG set of Kirloskar make.
Supply and fix in replacement AVR ( automatic voltage regulator ) for DG sets 45 KVA to 100 KVA complete all as specified and directed.
Supply and fixing in replacement DG set controller model EMS 926 in control panel of DG Set 100 KVA, Make - CROMPTON GREAVES, duly programmed by manufacturer ,testing and comissioning complete all as specified and directed.
Supply and fixing in replacement VMR suitable for AMF of 320 KVA Kirloskar DG set controller model VMR 3P ,testing and comissioning complete all as specified and directed.
M&L for replacement of power contactor 4 pole ,415 volts, 700 amps coil operating voltage 230 Volt AC, Make-INDOASIAN / L & T model MCX-46 or equivalent as in PS.
M&L for replacement of power contactor 4 pole ,415 volts, 160 amps Make L & T model MCX-32 or equivalent as in PS.
Supplying, installation, testing & commissioning in replacement of Intelligent Addressable Potential-free, Form-C, SPDT contact based control module. Make:- Simplex
M&L for replacement of phase indication light LED type for LT panels in three colours (R,Y,B) complete all as specified and dirtected.
Supply and fix in replacement din rail multifunction digital timer switch Make GIC model 67DDTO complete all as specified and directed.
Supply and fix in replacement Power contactor 4 pole 40 amps Make L & T complete all as specified and directed.
Supply and fix in replacement Power contactor 4 pole 63 amps Make L & T Cat No. MCX 12 model No CS97014 complete all as specified and directed.
M & L for rubber mat (electrical insulation mat) of size 1Mtr X 2 Mtr and for voltage upto 11 KV make - Jyoti or as per PS .
M&L earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth wire 4Sq mm as earthing leads by means of bolts, nuts, check nuts and washers properly jointed as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate 600X600X6.3 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth strip of 32X6 mm as earthing leads by means of bolts, nuts, check nuts and washers beside Welding / brazing at all joints as shown on drawings and including excavation, earth work. GI pipe light grade 40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed.
Supplying & Fixing GI electrode chemical earthing of high conductive, corrosion resistant, CPRI tested maintenance free chemical earthing pit, to achive earth resistance value less than or equal to 2 Ohme, pipe in pipe technology based in which primary conductor (Pipe) having 40 MM dia and secondary conductor having 80 MM dia. The primary conductor is inserted into secondray conductor and spce between secondary and primary conductor of earthing electrode should be filled with crystalline compound. The length of this electrodes is min 3000 MM (3 meters) and earth pit's bore hole should be of dia 200 to 250 mm and min depth 3.50 meters. Length of electrode will be increase with connecting of 32 x 6 mm GI strip extra, and total depth of earthing electrodes should not less than 3.50 meters. Around the earth electrode earth pit bore hole should be backfilled with minimum 50 Kg of ground enhencement compound ERIC ( ERIC Contains mixture of Silica sulphate, Alumina, Iron Oxide, titanium Oxide, Calcium Oxide, Magnesium Oxide,Sodium Oxide, Zink Oxide etc. ). including RCC earthing pit having 450 x 450 CI chamber cover all as directed by Engineer-in-Charge. ( Note : If less than 2 Ohme result has not acheived at site the contractor is responsible to do grid system to achieve the desired result and no extra payment shall be made to the contractor for making grid system.) Make Remedies, Model - RSPL-G803 / MRS agency Model G-80.
Supplying & Fixing Copper electrode chemical earthing of high conductive, corrosion resistant, CPRI tested maintenance free chemical earthing pit, to achive earth resistance value less than or equal to 1 Ohme, pipe in pipe technology based in which primary conductor (Pipe) having 40 MM dia and secondary conductor having 80 MM dia. The primary conductor is inserted into secondray conductor and spce between secondary and primary conductor of earthing electrode should be filled with crystalline compound. The length of this electrodes is min 3000 MM (3 meters) and earth pit's bore hole should be of dia 200 to 250 mm and min depth 3.50 meters. Length of electrode will be increase with connecting of 32 x 6 mm copper strip extra, and total depth of earthing electrodes should not less than 3.50 meters. Around the earth electrode earth pit bore hole should be backfilled with minimum 50 Kg of ground enhencement compound ERIC ( ERIC Contains mixture of Silica sulphate, Alumina, Iron Oxide, titanium Oxide, Calcium Oxide, Magnesium Oxide,Sodium Oxide, Zink Oxide etc. ). including RCC earthing pit having 450 x 450 CI chamber cover all as directed by Engineer-in-Charge. ( Note : If less than 1 Ohme result has not acheived at site the contractor is responsible to do grid system to achieve the desired result and no extra payment shall be made to the contractor for making grid system.) Make Remedies / MRS agency.
M & L for fabrication and installation / errection of sign board (as marker of earth pit ) made out of 3.15 mm thick MS flat iron plate of size 150 mm wide and 250 mm length and shall be welded properly with angle iron support of size 300 X 300 X 4.0 mm thick of length 800 mm in which 300 mm will be embedded in PCC foundation of size 30X30X35 cm depth below ground level with cement concrete of ratio 1:4:6 type B1 using 20 mm graded stone aggregate and slope copping not less than 100 mm above GL including plastering,white washing of masonary surface and two coaats of synthetic enamelled paint of coloure as directed over a coat of red oxide primer on steel surfaces as well as writing following details in capital letters form of 25 mm height and 10 mm width on front side of the steel plate in black colour paint all as specified and directed . (a) Type of earthing (b) Equipment connected.(c) Number of earth pit & earth resistance value. Note :- Flat iron plate will be modified as triangular / circular / rectengular etc. as per sketch / dircted by Engineer - in - Charge but not exceeding the dimentions as given in schedule
Supply & Fix earth continuity conductor or main earthing lead fixed to wall on battten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to pole or any other indicated situatioin for loop earthing etc. as required size 20 X 3 mm copper strip complete all as specified and ditected.
Ditto but size 25 X 4 mm GI strip .
Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M&L for point wiring controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 3.00 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed for following :- (a) One Light/fan point controlled by one switch
(b) One 5 Amps socket point controlled by one 5 Amps switch on same board.
(c) One 5 Amps socket point controlled by one 5 Amps switch on independent board.
(d) One bell point controlled by one 5 Amps bell push.
(e) One light point controlled by two 5 Amps two way switch.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 3.00wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 2 to 7 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
M&L for point wiring controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including PVC casing caping all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. (a) One Light/fan point controlled by one switch
(b) One 5 Amps socket point controlled by one 5 Amps switch on same board.
(c) One 5 Amps socket point controlled by one 5 Amps switch on independent board.
(d) One bell point controlled by one 5 Amps bell push.
One light point controlled by two 5 Amps two way switch.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including PVC casing caping with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 8 to 12 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 5/6 amp, single pole, two way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed.
S&F socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed.
S&F switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed.
S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
S&F only modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed.
S&F only modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed.
S&F only modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F only modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F only switch socket combination multipurpose 5 pin 5/15 Amps
S&F only modular bell push pole 1 way, 1 module, 6 Amp complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F in repairs Call bell ding dong, AC single pole 240 volts complete all as specified and directed.
Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
S&F 22 watt LED light fitting engineering extruded aluminium batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make :- Phillips ,Product SKU : 919515813187.
S&F recess mounting LED luminaire of size 2'x2' white 30 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Philips, Product SKU : RC360B LED36S
S&F recess mounting LED luminaire round shape 12 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make Philips, Product SKU : 59137
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make: Phillips, Product SKU : WT202W LED 10S CW PSU S3 PC
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 25 W LED Bldg security light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Havells Cat No. ENDURA CITYLITEPLAT PLUS SL25WLED 757S ASYBOPC or equivalent iin Bajaj/ Philips/ CG/ WIPRO
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED building security light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Havells Cat No. ENDURA CITYLITEPLAT PLUSSL35WLED 757SASYBOPC or equivalent iin Bajaj/Philips/CG/ WIPRO
S&F lamp LED 18 watt, 240 volts complete all as specified and directed. Make : Phillips, Make: ACE Bright
Taking down carefully old and unserviceable sub main wiring of 2/3 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed.
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 2.50 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 1.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 2.5 sqmm conductor cable, 1 No 1.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for sub main wiring with 2 Nos single core PVC insulated -unsheathed 6.0 Sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 6.0 Sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 Sqmm conductor cable, 1 No. 6.0 Sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F modular type PVC enclosure with a two pin and earth plug and socket 16 Amps complete with one single pole MCB 20/25 Amps capacity complete all as specified and directed. Make: Havells, SKU : DHDPHSN020
Taking down old unserviceable MCCB DBs / MCB DB / Main Switches including MCBs/ MCCBs/ Isolaters, complete all as specified and as directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed. Make: Havelle, SKU - DHDLVDOBGSFE04
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
Taking down Unsv MCCb/MCB of any specification.
S&F MCCB, 4 pole, 63 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCCB, 4 pole, 100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SP, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TPN, 40 to 100 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F only tape insulation, 1100 volts grade 20mm width, 15 mtrs long complete all as specified and directed.
Supply only wire flexible 23/0.0076, twin core twisted, PVC insulated copper stranded conductor complete all as specified and directed.
Supply and fixing in repairs ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) Note : UNSV fans will be deposited to MES Store by Contractor.
S&F in replacement U/S and broken exhaust fan (air freshener) single phase 230/240 volt AC 300mm sweep with louvers, steel body with twisted copper flexible wire 23/0.0076mm including taking down old fan and deposited in MES store complete all as specified and directed. Make: Havells/Bajaj/CG.
Disconnecting, taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans, air circulating fans and pedestal fans etc. of any description, any sweep and from any position/locations for repairs/servicing/numbering, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing, fixing the serviceable parts in position, removing & repair of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging/fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed. Note:- (i) The repair of defective/ nonfunctional parts shall be measured & paid separately as “Supply and fix in repair” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item here-in-after. (iii) The rates for above items are deemed to include transportation charges from E/M store yard to workshop and vice versa.
Taking out & removing old burnt-out winding and rewinding of motor of ceiling fans 1200/1400 mm sweep of any description and rewinding of fan motor with appropriate size super enameled copper wire approx 200 gram including insulating material such as illumines paper, letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of the department for the following Fans:- Make of winding wire: Atlas/Finolex/ Devi Dayal
S&F modular fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
S&F in repair ball bearing No. 6200 to 6203 complete all as specified and directed. Make:-SKF/NRB/NBC/TATA
S&F in repair gun metal bush of any description and size to suit existing motor shaft complete all as specified and directed.
S&F in repair capacitor of capacity 2.5 mfd PVC body complete all as specified and directed. Make:- EPCOS/JYOTI/ USHA
S&F in repair capacitor of capacity 3.15 mfd PVC body complete all as specified and directed. Make:- EPCOS/ JYOTI/ USHA
All as per item No.184 above but rewinding of motor of exhaust fans of 225/250 mm sweep with 170 gram winding wire.
All as per item No. 184 above but rewinding of motor of exhaust fans of 300/400 mm sweep with 200 gram winding wire.
All as per item No. 184 above but rewinding of motor of air circulating fan of 400 mm sweep with 300 gram winding wire.
All as per item No. 184 above but rewinding of motor of pedestal fan of 400 mm sweep with 400 gram winding wire.
All as per item No. 184 above but rewinding of motor of wall mounting fan of 400 mm sweep with 400 gram winding wire.
Supply only in repair complete fan hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed.
Supply only in repair 300mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and directed.
Supply only in repair 900mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and directed.
Supply and fixing in repair fan blade suiatable for 400mm sweep pedestal fan/ Wall mounting fan.
Supply and fixing in repair metal fan blade suiatable for 450mm sweep exhaust fan.
Supply and fixing in repair fan blade suiatable for 300 mm sweep exhaust fan.
Supply and fixing in repair fan blade suiatable for 230 mm sweep exhaust fan.
S & F in replacement Printed Circuit board (PCB) of ceiling fan 1200/1400mm sweep of any Make Havells/Crompton complete all as specified and direcetd by Engr-in-Charge.
Disconnecting, taking down & removing carefully the existing Geyser of any capacity from any position/locations for repairs / fixing the serviceable parts in position, removing & repair of defective/ unserviceable parts, if any, with new parts, reassembling the geyser, hanging/fixing the repaired geysers in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed. Note:- (i) The repair of defective/ nonfunctional parts shall be measured & paid separately as “Supply and fix in repair ” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (iii) The rates for above items are deemed to include transportation charges from E/M store yard to workshop and vice versa.
S&F in repair heating element of 1.5KW any type as per sample ISI marked complete all as specified and directed.
S&F in repair heating element of 2.0KW any type as per sample ISI marked complete all as specified and directed.
Supply and replace complete geyser asseembly as per exisiting sample including rubber washer and nuts & bolts suitable for water heater capacity 25 Ltrs of any make.
M&L for repairing leakage of inner copper tank of geyser (any make) 25/50 litres capacity by brazing including all necessary denting etc complete all as specified and directed
S&F in repair thermostat suitable for 25/50 Ltr geyser complete all as specified and directed.
S&F in replacment PVC pipes of 450mm long best quality, heavy duty for geyser of 15mm dia with brass connecting nuts/couplers complete all as specified and directed.
S&F in replacment indicator lamps red and green colour 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repair stop cocks brass CP 15 mm dia suitable for above geyser ISI Marked.
Supply and fixing in repair PVC insulated copper conductor cable 3 core 6 Sq mm 660/1100 volts grade make Kalinga/Finolex/Rallison.
Supply and fixing in repair of plug top 3 pin 15 Amps.
Supply and fixing in repair safety valve to blow of at high rated temperature having latest ISI marked.
Collecting and transporting of desert coolers from MES store yard/user bldgs to work shop and overhauling of fan motar, oiling to vertical pump including repair of unserviceable bolts and nuts with washers, clamps etc.complete and returning back to MES store yard/user locations complete all as specified and directed.(Note :-Parts except nut bolt & washers to be replaced will be measured and paid separately under respective items)
Supply & Fixing in repair fan motor 1/7 HP or any HP complete set with arm and fan blade etc. ,230 volt,50Hz cycles A/C supply of make Summer Cool/CG /Havells/Bajaj complete in all respect.
Supply & Fixing in repair fan blade as per existing sample and size not exc. of 450 mm sweep suitable for fixing with fan motor fixed in desert coolers.
Supply & Fixing in repair capacitor, 4 / 3.15 +/- 5% mfd rating Asian/Univarsal make .
Supply & Fixing deset cooler's fan speed regulator ( three stage ie low, medium & high speed ) switch with Knob 230 V , AC supply complete all as specified and directed.
Supply & Fixing repair plug top, 5 Amps, 230 Volts, 50 Hz, A/C supply make anchor.
Supply & Fixing repair PVC flexible copper conductor cable three core ,1.5 Sq mm .
Supply & Fixing in repair PVC pipe, heavy duty, best quality of 15mm bore/dia.
Supply & Fixing in repair wood wool pad (set of 3) of good quality for desert cooler complete in all respected.
M & L for preparation of steel surface of desert coolers followed by painting with one coat of synthetic enameled paint complete on metallic surface external and internal complete in all respect as directed by Engr-in-Charge. (a) upto 3000 Cum/Hour capacity
All as per item cbove above but above 4000 cum/hour capacity.
S & F in repair side panels made with 2.0 mm thick MS sheet as per existing size and sample for desert cooler.
S & F in repair bottom tank made with 2.0 mm thick MS sheet as per existing size and sample for desert cooler.
M & L for repair of unserviceable sealed unit (compressor) of water coolers with new sealed unit (recommended by manufactorer) sealed unit make kirloskar/Tecumsha for water cooler make Shri Ram / Usha / Voltas or Blue Star capacity from 150 Ltrs.
All as per item cbove above but capacity 120 Ltrs.
Supply & Fixing in repair relay assembly for water cooler of any capacity & make upto150 Ltrs.
Supply & Fixing in repair Over load protector for water cooler of any capacity & make upto150 Ltrs.
Supply & Fixing in repair Starting capacitor for water cooler of any capacity & make upto150 Ltrs.
Supply & Fixing in repair running capacitor for water cooler of any capacity & make upto150 Ltrs.
Supply & Fixing in repair thermostatic switch for water cooler of any capacity & make upto150 Ltrs.
Supply & Fixing in repair chromium plated push cock, self closing, spring loaded type 15mm dia.
Supply & Fixing in repair drain out PVC pipe, complete with clamp and washers, suitable for fixing in water waste tray (length of pipe 1.50 R.M. approximately)
Supply & Fixing in repair blower motor as per size & sample in water cooler, commissioning and testing complete in all respect.
Repair to water cooler's body/base by cutting of rusted / deteriorated steel sheets and S & F new MS sheet of 1.6 mm thick for body and 3.16 mm thick for base with necessary spots welding including repair of legs as per existing size and applying red oxide primer on new sheet complete all as specified and directed.( Note:- 1. Finishing cost to be applied shall be measured and paid separately 2. Cost of taking down compressor or any other parts and refixing the same deemed to be included in unit rate quoted by contractor.)
M & L preparation of old painted surface of water coolers and applying one coat of super enameled paint by spray painting gun for water coolers any make and size upto 150Ltrs capacity all as specified and directed.
Repairs to water cooler's water storage tank by running contineous welding (gas welding) for prevention of leakage at places as directed by Engineer - in - Charge.
M & L complete servicing of water cooler by cleanning of coils with caustic soda, removal of rust from sheet metal frame, cleaning of tank and cheacking of water connection and fixing in original position complete in all respects.
M & L for gas charging in water cooler by using refrigerant as per standared specific after proper flushing vacuuming detecting leakge,rectification of leakages commissioning and testing for water cooler.
Repair to refrigerators complete by cleaning of system properly with CTC. Charging refrigerant including repair of unserviceable sealed unit (Compressor) of Refrigerator with new sealed unit, recommended by manufacturer Make Kelvinator /Godrej /LG of 308/325 Ltrs capacity.
Supply and fixing in repair of box type relay for any make and capacity upto 310 ltrs refrigerator.
Supply and fixing in repair thermostatic switch for any make and capacity upto 310 ltrs refrigerator.
Supply & fixing in repair of wiring kit suitable for any make refrigerator of 165 to 310 Ltr capacity.
Repair to Deep Freezer complete by cleaning of system properly with CTC. Charging refrigerant including repair of unserviceable sealed unit (Compressor) of deep freezer with new sealed unit, recommended by manufacturer Make Voltas of 320 Ltrs capacity.
Supply & Fixing in repair blower motor as per size & sample in deep freezer, commissioning and testing complete in all respect.
Repair to window / Split type Air conditioner by repair of unserviceable sealed unit i.e.compressor (rotery or hermetic) ,cleaning of system properly with CTC and charging the refrigerant (including cost of refrigerant ) recommended by manufacturer of AC including commissioning and testing complete all as specified and directed by Engr - in - Charge at site for 2 TR Window / Split type AC.
All as per item cbove but 1.5 TR Window/Split for Air Conditioning.
S & F in repair condenser coil as per sample for 1.5 Ton A.C. Note : Charging of refrigerant including cost of refrigerant will be measured and paid separately under respective item.
S & F in repair relay suitable for split type AC / window type AC upto capacity of 2TR.
S & F in repair over load protector suitable for split type AC of 1.5 Ton.
S & F in repair for air conditioners, capacitor 36 / 45 / 50 +6 mfd +/- 5% ,440 V AC .
S & F in repair thermostatic switch suitable for 1.5 / 2 ton AC make Renutrol.
S & F in repalcement fan motor with blade as per size and sample suitable for FCU unit of Split type AC of capacity 1.5 Ton of make LG/Voltas/Blue Star complete all as specified and directed.
S & F in repalcement fan motor with blade as per size and sample suitable for FCU unit of Split type AC of capacity 2.0 Ton of make LG/Voltas/Blue Star complete all as specified and directed.
S & F in repalcement blower fan motor for indoor unit of Split type AC of capacity 1.5 Ton of make LG/Voltas/Blue Star complete all as specified and directed.
S & F in repalcement blower fan motor for indoor unit of Split type AC of capacity 2.0 Ton of make LG/Voltas/Blue Star complete all as specified and directed.
S & F in repalcement fan motor with blade for Window type AC of capacity 1.5 Ton of make LG/Voltas complete all as specified and directed.
M & L for gas charging in split type AC unit 1.5 TR capacity using refrigerant as per standard practice after flushing, vacuuming including detecting leakage, rectification leakage, commissioning and testing complete in all respect.
All as per item cbove but for split type AC unit of 2 TR capacity .
All as per item cbove but for window type AC unit of capacity 1.5 TR capacity .
S & F in repair power PCB as per sample suitable for 1.5/2 TR Split type AC, making connection & testing complete all as specified.
S & F in repair copper connection pipe with union at both ends and with insulation, between FCU unit and indoor unit of length twelve feet for 1.5/2 TR Split type AC, making connection & testing complete all as specified.
S & F in repair insulation on copper tubing suitable for split type AC.
S & F in repair drain hose pipe suitable for 1.5 / 2 TR split type AC.
S & F in repair air filter as per existing size suitable indoor unit of 1.5 TR split type AC.
S & F in repair auto chang over unit with inbuilt timmer (programmable for operation between 01 hour to 24 hrs) having facility to operate alternatively two AC upto capacity 2.0 TR , commissioning and testing complete all as specified.
M & L for complete servicing of Air conditioner window/split type including cleaning of colling coil and condenser by caustic soda solution including removal of dust by using blower/brush to external fins and from beneath assets, cleaning of base tray properly including oil to fan & condenser motor, tightening of all electrical connections with proper alignment including fitments in their locations and repairs of suction & discharge tubes complete in all respects. (Note :-Filling of refrigerant if required or parts to be replaced will be measured and paid separately under respective items)
Repair of voltage stabilizer of capacity 5 KVA/4KVA by carying out rewinding of main transformer, repair of volt meter, relay, timer and IC circuit as required and making functional and testing complete all as specified and directed .
Repair of voltage stabilizer of capacity 2 KVA/1 KVA by carying out rewinding of main transformer, repair of volt meter, relay, timer & IC circuit as required and testing complete all as specified and directed .
Maint repair of reverse osmosis with UV water purifier system five stage having storage capacity 10 Ltrs and flow capacity 15 Ltrs per hour by cleaning supply & fix in repair required parts such as connecting pipe, buster pump, filter element (pre carbon/ UFmembrane/RO inline carbon filter) adapter,UV lamp ,SMPS etc. and making RO complete serviceable & testing complete all as specified and directed for RO of make KENT / Aquafine / Aquasoft.
M/s A.K Construction (BID ID -3328922)
M/S DEEKSHA CONSTRUCTION (BID ID -3327796)
PANDEY TRADERS (BID ID -3329469)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .