Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.0 LAccepted-AOC | ₹9.0 L | 1 | Accepted-AOC L1 |
| 2 | 2₹10.0 L+₹98,508 (10.9%)Rejected-AOC | ₹10.0 L+₹98,508 (10.9%) | 2 | Rejected-AOC L2 |
Tender Value
₹8.3 L
EMD Value
₹16,660
Closing Date
27 Jan 2023, 12:00 pmClosed
Executive Engineer, PHE Division KKR
Executive Engineer, PHE Division KKR
Supplying of pH meter, Spectrophotometer, Quartz Cuvette, Ionic Strength Adjuster etc. for Sub Division Lab Pehowa at PHE Division Kurukshetra and all other works contingent thereto.
2022_HRY_248637_3
WQMS Activity 2022-23 Water Quality Monitoring Sur
Open Tender
Civil Works
Supply
60 days
Executive Engineer, PHE Division KKR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹16,660
Yes
17 May 2024
18 Jan 2023
27 Jan 2023
18 Jan 2023
27 Jan 2023
18 Jan 2023
Amount
N.S.Items
pH meter Purpose: It is an instrument that is used to measure acidity/alkali nity of a solution. Eutech, WTW (Xylem), Oakton, Metrohm, ELICO pH Range - 0 to 14.00 pH; Batteries: 4 x 1.5 V alkalimanganese batteries, type AA; Operational life: Up to 800 h without / 100 h with illumination. Resolution/Accuracy 0.001 pH/± 0.005 pH; Operational life: Up to 800 h without / 100 h with illumination; Operation Temp - 0°C-100°C ORP Range ± 2500 mV; USB interface- USB B (device), data output; Admissible relative humidity- Yearly mean: < 75 %, 30 days/year: 95 %, Other days: 85 % "Resolution 0.1 (± 1200.0mV) / 1 mV (beyond); EMCEC directive 2004/108/EC 1.5 Lakh (with 5 years AMC) Equipment Specification Public Health Engineering Department 5 EN 61326-1; Dimension: 240 x 190 x 80 mm; Weight 0.8 kg" 1.2 ± 0.2 (± 199.9 mV) /± 2 mV (beyond) Temp range 0.0 to 100.00 C (32.0 to 212.00 F) Resolution/Accuracy 0.1 0 C (0.1 0 F)/±0.3 ºC / ±0.5 ºF (0 to 70 ºC) ATC Yes (0 to 100 0 ºC) Buffer Options USA: pH 1.68, 4.01, 7.00, 10.01,12.45 NIST pH 1.68, 4.01, 6.86, 9.18 ,12.45 No. of pH Calibration Points 5points Built-in Electrode Arm Yes Memory 100 data sets Electrode Included ECFC7252101B, single junction pH electrode. Temp Probe Included LCD DISPLAY CUSTOM dual-display LCD(5.6X7.5cm) Power Requirements Included, 100 /240VAC SMPS Power Adapter with US/UK/EUR/Japan plug ,9V,6W, CENTRE (with 2 years AMC)
UV-VIS dual beam Spectrophotometer DR-600 (benchtop) Hach Purpose: used in applications such as determining the concentration of analyte in solution by measuring the absorbance at a dual wavelength. Advantage: Better performance than single beam spectrophoto meter Disadvantage : More expensive than single beam spectrophoto meter"The Spectrophotometer will be dual beam (viz. UVVisible) operation and with the reference cell position for kinetics application. It will mandatorily have an 8- cell carousel. The spectrophotometer must have room-light resistance, allowing lid-open operation for improved speed and convenience. The Spectrophotometer will have option of automated cell changers and cell holders, sipper, and fiber optic probes for measurements outside of the sample compartment. It must accommodate high throughput measurements and temperature control. The Spectrophotometer will have following features: i. Spectrophotometer will be Double Beam (UVVisible)/Reference Cell ii. It is will have High resolution touchscreen user interface. The spectrophotometer must be capable of operating through computer also. iii. There will be 8-position cell changer with switchable turret iv. It will have onboard methods, reporting and data export v. It is capable of open-lid operation. vi. There will be room light resistance. vii. It will have sipper(optional) viii. It must have optional facility for 4-position cell changer (long path cells) and Peltier-thermostat single cell holder (20 °C - 60 °C) Specifications: Detector Type Dual Silicon Photodiodes Display 7-inch colour touchscreen, high definition, 800 × 1280 pixels Photometric Accuracy Instrument ±0.002A at 0.5A ±0.004A at 1.0A ±0.008A at 2.0A Wavelength Accuracy ±0.5 nm Baseline Flatness ±0.002A Compartments 8-position cell changer (standard) Drift (At 500 nm after 1-hour warmup) 5 years typical, 3 years guaranteed) Noise (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm Optical Design Double Beam Photometric Display -3A to +5A Photometric Range –2A to +3.5A Photometric Repeatability ±0.001A at 1A measured at 1.0A at 546 nm Spectral Bandwidth 2 nm Stray Light < 1.0%T 198 nm (KCl), < ±0.2 nmWavelength Scan Speed Slow, medium, and fast - up to 1600 nm/min Computer operation: The spectrophotometer can be operated from compatible computer and software. Computer and operational software to run Spectrophotometer will be a part of the spectrophotometer. Connections Single USB-A supports flash memory devices for method and data storage Warranty 3 years (with 5 years AMC)
quartz cuvette for spectrophotometer
Ionic Strength adjuster for fluoride (TISAB III)
R K Traders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .