Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹44.9 L+₹68,973.50 (1.56%)Rejected-Finance 84 B LOWER BURDWAN COMPOUND RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹49.0 L+₹4.8 L (10.9%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted | |
| 4 | Rejected-Technical VILL NUTAN PALLY AMMUNITION ROAD PO PS BUD BUD DIST BURDWAN PIN 713403 WB | BUD BUD | BURDWAN | WEST BENGAL | 713403 | - | Rejected-Technical Doesnt meet the eligibility criteria |
Tender Value
₹49.7 L
EMD Value
₹99,500
Closing Date
21 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_532405_1
8400-820/E8
Open Tender
Civil Works
Works
210 days
PANAGARH
Class D, Cat a (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹99,500
Yes
26 Aug 2022
21 Jun 2022
22 Jul 2022
21 Jun 2022
21 Jul 2022
7 Jul 2022
60 days
Amount
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Surface dressing n.exc 15 cm deep and getting out in soft/loose soil complete all as specified and directed
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n.exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n.exc 10 sqm on plan and getting out complete all as specified and directed
Excavation in trenches in soft/loose soil n.exc 1.5m wide and exc 1.5m but n.exc 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n.exc 10 sqm on plan and getting out complete all as specified and directed
Removing surplus excavated spoil/earth to a distance n.exc 50m and deposited where directed at a level n.exc.1.5m above the starting point complete all as specified and directed.
Returning filling in soft /loose excavated soil including spreading leveling watering and well ramming in layers n.exceeding 25cm and complete all as specified and directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled and blinded with earth and rammed incl watering complete all as specified and directed.
M&L for hardcore of broken stone or boulder of gauge exc 63mm but n.exc 75 mm deposited, spread & leveled in lyers n.exc 15 cm thick watered & rammed to a true surface complete all as specified and directed.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) as foundation and mass filling complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) as in chajjas complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) columns, pillars, piers, posts and struts complete all as specified and directed
M&L for brick work with flyash bricks old size straight or curved on plan to any radius exc 6m mean radius built in CM (1:6) complete all as specified and directed
M&L for half brick work with flyash bricks old size straight or curved on plan to any radius exc 6m mean radius built in CM (1:4) complete all as specified and directed
M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface of concrete complete all as specified and directed
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; n.exc 200mm thick (Horizontal or sloping) for fair finished surface of concrete complete all as specified and directed
Formwork to chullah hoods, chajjas, troughs and similar items including ege for fair finished surface of concrete complete all as specified and directed
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for fair finished surface of concrete complete all as specified and directed
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface of concrete complete all as specified and directed
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel moulded both side Prelam PVC sheet strip of 20mm width stuck inside with solvent cement for stiles prelam PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of both sidePrelam PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing complete all as specified and directed
S&F solid PVC door frame of size 50mmx47mm made out of 5mm single side prelam PVC sheet & edges will be painted to match with prelam sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing complete all as specified and directed.
S&F butt hinges mild steel 100mm long, medium weight, cooled rolled complete all as specified and directed.
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 150mm long extruded aluminium anodized barrel tower bolt of extruded section and fixed complete all as specified and directed.
S&F aluminium alloy,250mm long anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F in repair aluminium anodised tubular towel rail 20mm dia "D" type 60 cm long between flange fixed complete all as specified and directed.
S&F mild steel hat pegs,solid body,125mm to 175mm complete all as specified and directed
M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for TMT steel bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
S&F Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed
S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed
S&F Ball bearing for rolling shutters complete all as specified and directed
Supply and fix Steel windows with side hung shutters (minimum wt. of steel section should be 1.42 kg/M) including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S&F steel ventilators with centre hung shutter (minimum wt. of steel section should be 1.42 kg/M) including two pairs of brasscup pivots, catch spring and pulleywheel, complete dovetailed or welded including pintol hinges, steel handles, etc. as shown with fixed type complete all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) to receive tiles complete all as specified and directed.
M&L for joint free non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 Sqm but n.exc 0.11 sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match the shade using coloured tiles incl 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L for joint free Glazed ceramic coloured tiles in vertical surfaces (450 x 350mm) 7mm/ 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement ot match, with backing coat 10mm thick in CM (1:3) complete all as specified and directed.
M&L for 75 mm thick, Cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate), as in sub base complete all as specified and directed.
M&L for 50mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in flooring finished even and smooth with using extra cement complete all as specified and directed
M&L for rendering 5mm thick in CM (1:3) finished even and smooth with using extra cement complete all as specified and directed
M&L for 75mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection finished even and smooth with out using extra cement complete all as specified and directed
M&L for 15mm thick in CM (1:4) rendering on brick or concrete surfaces finished even and smooth with integral water proofing compound on wall complete all as specified and directed (Note: WPC will be measured and paid seperately)
Supply only intergral water proofing compound (liquid admixture) (Make : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for 15mm thick in cement plaster CM (1:6) on brick or concrete surfaces finished even and smooth without using extra cement on wall complete all as specified and directed
M&L for rendering 5 mm thick in CM (1:3) on ceiling finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for 10mm thick in cement plaster CM (1:4) on brick or concrete surfaces finished even and fair with using water proofing compound complete all as specified and directed
M&L for preparation new surface of roof and applying two coat of polyurethene (PU) acrylic based water proofing liquid compound over & including one coat of self priming primer @one litre per ten sqm with reinforcing fabric sheet as per manufactures instruction to stop leakage /seepage from roof/wall complete all as specified and directed by the Engineer-in-Charge. (Notes- 1.as per description of the items minimum two coats of polyurethene (PU) acrylic based water proofing liquid compound over one coat of primer shall be carried out by the as per manufacture instruction.pl note no price adjustment shall be made,if more coats of (PU)acrlic based water proofing liquid compound & primer are required for roof treatment. 2. quated rate shall be deemed to be included for work in building/structure of any height).
M&L for three coats of white wash as in ceilings on newly plastered surfaces including preperation complete all as specified and directed
M&L for three coats of white wash as on walls on newly plastered surfaces including preperation complete all as specified and directed
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gM&Litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including Preparation of new plastered surfaces complete all as specified and directed (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar).
S&F sheet glass, 4,0 mm thick ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed
S&F sheet glass, 3,0mm thick pin headed quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed
M&L for preparation of new surfaces of steel and applying two coat synthetic enamel paint over a coat of red oxide primer to steel surfaces of any description not otherwise described over 10cm width or girth complete all as specified and directed.
S&F GI pipe medium grade 15 mm dia bore as in walls with all fittings fixed to complete all as specified and directed
S&F GI pipe medium grade 20 mm dia bore as in walls with all fittings fixed to complete all as specified and directed.
S &F 15mm CP angular stop cock with flange complete all as specified and directed
S&F 15 dia fancy type chromium plated bib taps cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe complete all as specified and directed
S&F pillar taps, cast copper alloy, fancy type, chromium plated, screwed down high presure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed
S&F vitreous china squatting pan Orissa pattern of size 580mx440mm wite with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding complete all as specified and directed
S&F PVC valveless syphonic action type flushing cistern 10Ltr capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe complete all as specified and directed
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed
S&F vitreous china wash basin, white, flat back size 550x400mm, incl cutting for and pinning in ends of brackets or erecting stand but excl taps, pvc conections but incl brackets, waste pipe, waste coupling complete all as specified and directed
S&F 500 litre capacity rotational moulded polythylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as per specified in SSR part-I. complete all as specified and directed (Make: Sintex/Polycon/Polyfoam)
S&F PVC ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe of 20mm bore complete all as specified and directed
S&F brass chromium plated shower rose 125 mm size fixed complete all as specified and directed. (Make: Prayag/ Jaquar/ Mark)
S&F PVC grating doom 100 mm dia complete all as specified and directed.
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement of dia of out let 75mm complete all as specified and directed
S&F PVC (SWR) pipes of 75mm dia double socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes of 110 mm dia double socketed, in any length with rubber ring joints laid in floors complete all as specified and directed
S&F PVC (SWR) door bends any radius for 75 mm bore dia complete all as specified and directed.
S&F PVC (SWR) bends any radius for 110 mm bore dia complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in ramp finished even and smooth with out using extra cement and making impression with XPM complete all as specified and directed
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting n.exc 10 cm girth complete all as specified and directed
M&L for plain cement concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) as foundation and mass filling complete all as specified and directed
M&L for brick work with fly ash bricks old size straight or curved on plan to any radius exc 6m mean radius build in CM (1:4) complete all as specified and directed
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping , benching. Hauncing etc finished even and smooth complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for 160mm thick PCC 1:3:6 type C2 Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed
S&F UPVC Eco Drain pipe drainage sewaer system pipe bearing 160mm dia minimun 4mm thick including jointing with coupler, bend, tee as per site requirement complete laid in trenches or floors complete all as specified and directed. (Note: PCC Haunching will be measured and paid seperately)
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required (100mm dia) complete all as specified and directed
Excavation in trenches, n. exc. 1.5m wide and n. exc 1.5m in depth, for foundation, laying of pipes, cables etc. or for shafts , wells, cesspits, manholes, pier holes, etc. n.exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in hard/dense soil complete all as specified and directed
M&L for plain cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregates) as in sub base of floors including finishing the surfaces even and rough to receive the topping layer complete all as specified and directed
M&L precast RCC type B-1 1:2:4 (using 20mm graded stone aggregate) as in cover slab for man hole and similar article with plain face set in cement mortar (1:4) complete all as specified and directed.
Cutting in to existing manhole for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required (200 mm) bore complete all as specified and directed
S&F 25mm bore GI tubing medium grade in trenches/floor / pillar connetion in old or new postion including fittings complete all as specified and directed.
All as per item No 90.00 mentioned here-in-above but 40 mm bore complete all as specified and directed
S&F 25 mm bore dia pipe gun metal globe or gate valves, yoke type, full opening with iron wheel head, screwed both ends heavy duty, ISI marked complete for iron pipes complete all as specified and directed.
S&F ball brass valves, high pressure, with polyethylene float and flynut complete, screwed for iron pipe or brass ferrule for 25mm bore complete including taking down complete all as specified and directed.
Lifting and shifting of existing sewage pump/blowers of any capacity from old location to New equipment room with assembly comlpete all as specified and directed.
Lifting and shifting of existing Panel of any capacity from old location to New equipment room with comlpete connection assembly complete all as specified and directed.
S&F 50mm bore GI tubing medium grade in trenches / Floor / pillar connetion in old or new postion including fittings complete all as specified and directed.
S&F 150mm bore GI tubing medium grade in trenches / Floor / pillar connetion in old or new postion including fittings complete all as specified and directed.
S&F 90mm bore 3 layer PP-R polypropylene randon having thermal stability for hot and cold water supply all PPR plain & brass threaded polypropylene random fitting in trenches / Floor / pillar connetion in old or new postion including fittings complete all as specified and directed.
Cutting, shifting and joining of existing pipe for new connection including all connected fitting complete all as specified and directed
E/M PORTION M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 100.00 mentioned here-in-above but same board with other switches complete all as specified ad directed.
M&L for wiring for 5 Amps socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
M&L for wiring for 15 Amps socket out let on independent Boards controlled by one, one way switch using 4 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed
S&F switch socket combination, 2 in 1 multipurpose 5 pin , (5/6 Amps ) complete all as specified and directed
S&F socket outlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and directed .( For Same Board only)
S&F switch socket combination, 5/16 Amps 5 in 1 flush type controlled by one switch complete all as specified.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
S&F 01x 18 W LED batten light fittings, with T-8 tube, lighting fixture with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed
S&F security light fittings 25 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all directed. (Make - Bajaj/Crompton/Phillips)
S&F lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified and directed
S&F metallic exhaust ventilation fan of sweep 300 mm sweep, 240volt AC, BEE 5 Star rated complete with louver and all asssesories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing connected with rwin core twisted flexible copper conductor (23/0.0076) of size complete all as specified and directed by Engr-in-Charge.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SPN 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F XLPE armoured cable 16 sqmm 4 core,1100 volts grade heavy duty cable passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as specified and directed
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using galvanised iron strip 32×6mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. (Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge , entered in the eath testing register, prepared and to be maintained by the contractor & submited to Concerned JE E/M. (iii) T&P and testing instrument(Meger) to be provided by the contractor at own cost).
UNITED BUILDERS
M/s RAJEN ROY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .