Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-Finance 135 ROY BAHADUR ROAD BEHALA KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | ₹4.0 L | L1 | Accepted-Finance 1st lowest bidder |
| 2 | L2₹4.0 LRejected-Finance | ₹4.0 L | L2 | Rejected-Finance 2nd lowest bidder |
| 3 | L3₹4.4 LRejected-Finance 447 A DHALITITHA BASIRHAT NORTH 24 PARGANAS PIN 743412 WEST BENGAL | BASIRHAT | NORTH 24 PARGANAS | WEST BENGAL | 743412 | ₹4.4 L | L3 | Rejected-Finance 3rd lowest bidder |
Tender Value
₹5.0 L
EMD Value
₹9,960
Closing Date
28 Jan 2026, 12:00 pmClosed
Exe. Engr.-II, Kol. South Health El. Divn., PWDte
75 D H Road Kidderpore Kol_23
Shifting of Sub-LT Panel from Laundry Block to PGT Hostel with allied Electrical Installation work for construction of Working Women Hostel by demolishing Laundry Block, Garage and kitchen for NTS in the premises of Chittaranjan Seva Sadan COGCH, Kol
2025_WBPWD_977216_1
WBPWD/EE-II/KSHED/Q92/25-26
Open Tender
ELECTRICAL WORKS ORG
30 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,960
O/o Exe. Engr., Kol. South Health El. Divn., PWDte
18 Feb 2026
19 Dec 2025
30 Jan 2026
19 Dec 2025
28 Jan 2026
30 Dec 2025
29 Dec 2025
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Polycab/Havells/RR Kabel) partly in 20mm size PVC rigid conduit 'FR' (Precision make HMS/MMS type) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand/Schneider/Crabtree) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run 8 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Polycab/Havells/RR Kabel) in 20mm size PVC rigid conduit 'FR' (Precision makeHMS/MMS type), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Legrand/Schneider/Crabtree) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.
On Board
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Legrand/Schneider/Crabtree) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Legrand/Schneider/Crabtree) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works (For 2x5A Points)
6 Module
Supply & Fixing 240 V 6 A Modular type switch (Legrand/Schneider/Crabtree) on existing GI Modular type switch board having top cover plate and making necessary connections as required. (For 2x5A Points)
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Legrand/Schneider/Crabtree) , without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For 2x5A Points)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make: Legrand/ ABB/ Schneider /LK]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [Make: Legrand/ ABB/ Schneider/ LK]
Supplying and fixing 240 / 415 V MCB of Breaking capacity lOkA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make: Legrand / ABB /Schneider/LK)
6-32 SP MCB
Distribution wiring in 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Polycab/RR Kabel/Havells) in 20mm size PVC rigid conduit 'FR' (Precision make HMS/MMS type) incl. necy. fittings as required
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supply and Delivery of 4 feet Single LED tube fitting incl. Supply & Delivery of 1 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply and Delivery of 4 feet Twin LED tube fitting incl. Supply & Delivery of 2 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Fixing only single/ twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with "L" type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, "L" type (125mmxl25mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1. 10 mt. length.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (l.5sqmm.) flexible copper wire of 1. 10 mt. length.
Supply & Delivery of 230V, 1-Ph, AC ceiling fan of follwing size incl. all accessories. (Make- Crompton / Usha/ Orient/ Polar) [BEE star ratedl
Sweep Size- 1200 mm (48"), Wattage 55 Watt, R.PM ≤ 380 Air Deliverv ≥210 C.M.M
Supply & Delivery of 220V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTONl [BEE star rated][ISI mark, IP55 rated]
225 mm (9"), 4 Blade, RPM ≤ 1400 , Wattage ≤ 45 Watt, Sound level ≤ 49 dB, Air Displacement (In CFM) ≥ 440
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)
Supply & Fixing 240V, Modular Socket (2 Module) type fanregulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necv. connections etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply & Fixing fan down rod (14 SWG- white MS pipe zinc plated) having 19mm OD 1.8 + / - 0.05 mm thick complete with cutting, making holes for fixing the fan incl. necessary connection wire (2X1.5sqmm cu wire) as per direction of EIC.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
For 23 cm (9") Exhaust fan
Supply of 4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 11OO Volts of following sizes [Make Polycab / RR /KEI/ Havells/Gloster as approved by E.I.C]
4 Core 10 sq. mm
4 core 95 Sq. mm
Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand.
Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
50 mm dia
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying of cable 4core 10sqmm Al Ar. cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supply & Fixing of 14SWG hot dip galvanised/ Powder coated ladder type cable tray [300mm(W)X75mm (H)], Side channel- 50mm15mm, Rung Dimension-35mmX15mm, Rung interval-250mm, Galvanising- Hot dip (As per IS:2629/4759) including S&F of L shape angle supports (40X40X5mm) to be grouted on wall as per direction including necy fixing nut bots etc. as required as per direction of EIC.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 core 10 sq. mm cable
4 core 95 Sq. mm cable
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4 core 10 sq. mm cable
4 core 95 Sq. mm cable
Supply & Delivery of 240V, LED street lights with optic lens and polycarbonate diffuser having following wattage, in white powder coated pressure die cast aluminium housing with IP 66 protection & incl. 10 kV SPD, with glare free uniform illumination with CCT (5700K-6500K) having minimum luminous efficiency of 110 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
S& Fixing of 250V. 25A timer controller for Single phase AC in SS double door 12-way DB enclosure (L&T / ABB / Hager make) with S&F following electrical accessories & front door locking arrangement with all connections by finish- ing the ends of 2 x 2.5 & 1 x 1.5 mm² copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall incl necessary connections as per direction of EIC i) 25A DPMCB (L&T make cat no B20250C) --1 No. ii) 24 Hr programmable Digital dial timer (L&T make cat no 67DDTO)--1No. iii) 3pole power contactor (L&T make cat no MNX22/230V)--1no iv) 6A SP MCB (make Legrand/ Myrius)--1no. v) 25A Auto-Off-Bipass SPDT toggle switch (Appvd reputed make)-1no. vii) LED indication lamp(approved reputed make)--4 no. viii) Outgoing connectror make ELMAX (approved reputed make)-2nos.
Dismantling & refixing the existing LT Cubical Panel (250A TPN Incomming and 6 outgoing switches) carefully by agency tools and trackles and fixing on wall by suitable size fastner nut, bolts etc as required & neccesarry connecton as required as per direction of EIC.
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By TATA-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
Defect Liability Period - 1 One) year after completion of work
Make & model of each and every material to be approved by EIC
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.26 MB
TenderForm.pdf
Tender Documents • 0.69 MB
BOQ_2380891.xls
BOQ • 0.87 MB
Download all tender documents and submit your bid