Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.0 LAccepted-AOC | 1 | Accepted-AOC BEING L1 | |
| 2 | 2₹44.8 L+₹4.9 L (12.1%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 2 | Rejected-Finance BEING L2 | |
| 3 | 3₹46.9 L+₹6.9 L (17.2%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | 3 | Rejected-Finance BEING L3 | |
| 4 | 4₹47.7 L+₹7.7 L (19.2%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | 4 | Rejected-Finance BEING L4 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
11 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UDHAMPUR
AF STATION UDHAMPUR
IMPROVEMENT OF ELECTRICAL INFRASTRUCTURE FOR AFNET AT AIR FORCE STATION UDHAMPUR
2023_MES_574368_2
GEAFU-65/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF UDHAMPUR
Refer tender documents
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹90,000
Yes
21 Mar 2023
18 Feb 2023
13 Mar 2023
18 Feb 2023
11 Mar 2023
24 Feb 2023
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in any type of soil including boulder complete all as specified and directed by the Engr-in-Charge.
Returning filling in soils including spreding, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified.
Removing surplus soil to a distance not exceeding 50 meter and sepositing where directed at a level not exceeding 1.5 meter above the starting point.
Dry coarse sand as cushioning to cable 8 cm before laying cable in trenches and 15 cm after laying the cable complete all as specified and as directed. Note : After punning down shall be measured 18 cm.
Supply and laying Brick tiles; common burnt clay building / ducts bricks’ sub-class 'B’ Designation 75 (230mmx115mmx75mm) complete all as specified and directed by Engineer-in-Charge
M & L for cutting of Road and Concrete surfaces upto 1.0 m depth and 500 mm wide for laying of cable / pipe in any type of soil, returning and filling in and spreading, leveling, watering and well ramming in layers not exceeding 25cm thick removal of surplus soil and provision of 150 mm thick PCC type B-1, 1:2:4 with 20mm graded crushed stone aggregate on top layer all as specified and as directed.
GI tube light grade of bore 100 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable complete all as specified and directed by Engr in charge
GI tube light grade of bore 80 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable complete all as specified and directed by E ngr in charge
Supply and fix cable jointing kit for 1100 KV grade cable for end joint complete with Jointing material heat Shrinkable type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1100 KV grade cable for end joint complete with Jointing material heat Shrinkable type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrinkable Lt straight through type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 150 to 185 sqmm,Indoor/Outdoor type complete all as specified and directed.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 185 sqmm x 3.5core confirming to IS-7098 amended upto date complete all as specified and directed by Engineer-Charge.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 95 sqmm x 3.5 core confirming to IS-7098 amended upto date complete all as specified and directed by Engineer-Charge.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 35 sqmm x 3.5 core confirming to IS-7098 amended upto date complete all as specified and directed by Engineer-Charge.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 sqmm x 2 core confirming to IS-7098 amended upto date complete all as specified and directed by Engineer-Charge.
PCC 1:3: 6 type C-2 with using 40 mm graded stone aggregate for making ducting/panels etc with necessary form work complete all as specified and directed
PCC 1:2:4 type B-1 using 20 mm graded stone aggregate for ducting/panels etc including necessary form work complete all as specified and directed.
M&L for repairing of damaged of water pipe line, JFC/OFC cable and HT, LT cable rectification will be responsible of contractor complete all as specified and directed by Engineer-in Charge.
Supply, install, testing and commissioning of silent type Diesel Engine driven generating set of min 125 KVA capacity 3 phase, 4 wire, 415 V, 1500 RPM conforming to relevant IS Codes, AC power supply with power factor 0.8 coupled directly to alternator mounted on a common ed Plate with sturdy design,Bed plate shall be suitable for mounting on anti viberation mounting system, load factor 0.85, complete with integral acoustic enclosure-sound proof canopy (should have silent features as per latest CPCB norms), fuel tank having facility for easy cleaning, Suitable Battery Charging unit incl battery & standard accessories, and at least 2 year warranty. (A) ENGINE : Liquid Cooled, electric Self start, 4 Stroke, min 6 cylinders cold starting, Naturaly aspirated /TCI aspirated( as per manufacturer standard), compression ignition, totally enclosed diesel engine , 1500 RPM suitable for 125 KVA alternator under NTP conditions as per ISO 8528 Part-I capable of taking 10% over load for 1 hours in every 12 hours continues running confirming to IS: 10000/10002/ISO 3046/ BS: 649/ BS: 554 amended up to date, the Engine shall consist of the following :- (i) Dynamically balanced fly wheel or as per manufacturer's standard (ii) Coolant cooling system complete. (iii) Air cleaner as per manufacturer's standard
(iv) Fuel injectors and fuel pump as per manufacturer's standard (v) Electronic governor as per manufacturer's standard to maintain engine speed at all conditions of load (vi) Fuel service tank of minimum 225 Ltr capacity fabricated from MS sheet with, inlet outlet connections, air vent tap,drain plug, Caliberated level indiactor(gauge), MS fuel piping from tank to engine with valves, unions, reducers, flexible hose connections, mounting pedestals, fuel filters incl all as per manufacturer's design (vii) Dry exhaust manifold with suitable exhaust residential grade, Asbestos rope of suitable size shall be provided as per manufacturer desires for silencer to reduce noise level as per CPCB norms (viii) Static Battery charging unit suitable for 180 Ah battery/battery array 12/24 volt having float, trickle and boost charging feature. Charging should be from utility supply/generator supply as directed by Engr in charge. (b) one/two battery of total capacity 180 Ah connected with copper lugs and minimum 50 sqmm cable placed inside the acoustic enclosure. (ix) Gear driven oil pump for lubricating oil, priming of engine bearing, as well as fuel systems as per manufacturer's recommendation (x) Natually aspirated/ turbo charger as per manufacturer's standard
(xi) Lubricaton oil coolers and filters with replaceable elements as per manufacturer's standard (xii) Crank case heater with manufacturer's recommendation. (xiii) All moving parts of the engine shall be mechanically guarded in such a manner that a human finger cannot touch any moving part. (xiv) Radiator as per manufacturer's standard (xv) Engine control panel having digital display complete with :- (aa) Start/stop key switch. (ab) Lubricating oil pressure indication. (ac) Lubricating oil temperature indication. (ad) Water temperature indication. (ae) RPM indication. (af) Engine hours indication. (ag) Battery charging indication. (ah) Low lub oil trip indication. (aj) High water temp indication. (ak) Over speed indication. (xvi) Any other item not included/specified but is a standard design of the manufacturer. (B) ALTERNATOR (i) Alternator of capacity 125 KVA , 1500 RPM, 0.8 lagging power factor, 3Ph, 415 V, 50 Hz, H Class insulated winding, IP-23 protection, Close-direct-coupled,brushles self-excited and self-regulated type, SPDP enclosure, mounted on rigid MS sheet channel base frame, alternator shall be confirming to IS: 13364, IS: 4722,IS 4889 , IEC: 34 and suitable for tropical condition.
(ii) Type : Brushless Self excited self regulated with automatic voltage regulator (electronic type) (iii) Rating : 125 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed : 1500 RPM (v) System : 415 Volt +/- 5 % AC 3 phase 4 wire 50 Hz. (vi) Connection : 4 wire star connected. (vii) Enclosure : Screen protected drip proof. (viii) Ventilation : Self ventilated (ix) Anti friction bearings. (x) AVR output voltage within +/- 1% (xi) Frequency in range 50+/- 3 %. (xii) Over load capacity and duration: 10 % for 1 hour after each 12 hour continuous operation, 50% for 15 sec. (C) Acoustic Encloser: (i) shall have Anti viberation mountings for direct mounting of engine alternator assembly. (ii) should be designed to meet CPCB norms for noise level (75dB at 1 mtr). (iii) Construction shall be such ,it prevnets entry of rain water splashing in to the enclosure and allows quick flow of rain water to ground in event of heavy rains. (iv) suitable no of doors shall be privided for easy servicing and part replacment of DG set. (v) it shall be suitable to be dismantled during overhaul of DG. (vi) It shall be suitable for cable entry upto 3.5 core 185 Sqmm XLPE cable. (vii) Inside of enclosure shall be provided with 2x 12 watt lead lamps cotrolled by 5 amp switch supplied from load side of AMF Panel.
(d) CONTROL PANEL The control panel is to be inside canopy and fabricated out of 1.6 mm thick CRCA sheet cubicle type totally enclosed, powder coated, IP-53 protection, equipped with MCCB/cuircuit breaker of suitable capacity, voltage metering & safety, frequency meter metering & safety, ampere metering & safety, fuel level gauge in % metering , Lub oil pressure metering, high water temp metering, engine RPM metering, Power metering, Power factor metering, set of suitable CTs, toggle switch, indicating LED lamps , incoming and outgoing terminals all as specified by manufacturer and directed by Engr-in-Charge. (a) Following engine shutown and alternator protection provisions shall be provided in control panel: (i) Engine: (aa) Low lubercating oil pressure shutdown. It shall be inoperative during starting and accelerating period of engine. (bb) High coolant temp shutdown. (cc) Engine overspeed shutdown. (ii) Alternator: (aa) overload. (ab) Short circuit. (ac) earth fault. (ad) Over voltage. (b) Monitoring and measuring Facility: (aa) Necessary energy analyser unit for visual monitoring of Mains, Alternator and load E11voltage,current, Frequency, power factor, KWH, KW etc. (bb) Visual monitoring lamp indication for load on DG set, Load on Mains, engine shutdown for overspeed, over load trip, earth fault trip, engin lockout and failure to start, all with audio and visual alarm.
Foundations :- A PCC 1:2:4 M-20 graded foundations of weight 2.5 times the operating weight of genset with enclosure or as recommended by Genset manufacturer OEM/OEA which ever is higher is required to be provided. 300 mm of this foundation height should be above ground level. Length and Breadth of foundations shall be atleast 1 mtr more on all sides than size of enclosures. Design as per recommendation of manufacturer shall be submitted by contractor and get approved before execution of work. Depth of foundation shall be 400 mm. Note :- Rate for foundation shall be included in the quoted rate. Note :- (i) Genset/Engine shall fulfill/confirm to latest CPCB emmission noise norms. The contractor shall produce/issue the certificate from manufacturer wrt. to compliance duly approved from agencies as approved by Govt of India. (ii) Payment shall be released only after receipt necessary of certificate. (iii) Necessary RECD device if required shall be deemed to be included in quoted rate.
Auto Mode :- (i) A line voltage monitor shall monitor supply on each phase when main voltage falls below set voltage (variable between 80 to 95 % of normal value) on any phase, monitor module shall initials start up of engine. To avoid momentary distribution, a time delay of 0-5 second adjustable shall be incompetent. (ii) This attempt starting facility of shall be provided 6 seconds On, 5 seconds off, 6 seconds on, 4 seconds off, 6 seconds on. If at the end of this attempt, the engine does not start, it shall be lodged out of start, a master time shall be provided for this functions. Suitable adjustment times be incorporated which will make it feasible to vary independtly ON & OFF points from 1 to 10 seconds, if alternator does not build up voltage after the first 2 second start as may be further starting attempts will not be made until starting facility is reset. (iii) One the alternator has built up voltage, the ulternator circuit breaker shall close connecting the load to alternator. The load is now supplied by the alternator. (iv) When main supply is restored and is healthy as sensed by the line voltage monitor setting, both for under voltage & unbalance. The system shall be monitered by suitable timer which can be set between 1 to 10 minutes for load to be transfer to mains. Manual Mode :- (i) It shall be feasible to start the DG with push buttons. (ii) This attempt starting facility shall be operarive.
Supply, install, testing and commissioning of silent type Diesel Engine driven generating set of min 15 KVA capacity 3 phase, 4 wire, 415 V, 1500 RPM conforming to relevant IS Codes, AC power supply with power factor 0.8 coupled directly to alternator mounted on a common ed Plate with sturdy design,Bed plate shall be suitable for mounting on anti viberation mounting system, load factor 0.85, complete with integral acoustic enclosure-sound proof canopy (should have silent features as per latest CPCB norms), fuel tank having facility for easy cleaning, Suitable Battery Charging unit incl battery & standard accessories, and at least 2 year warranty. (A) ENGINE : Liquid Cooled, electric Self start, 4 Stroke, min 3 cylinders cold starting, Naturaly aspirated /TCI aspirated( as per manufacturer standard), compression ignition, totally enclosed diesel engine , 1500 RPM suitable for 15 KVA alternator under NTP conditions as per ISO 8528 Part-I capable of taking 10% over load for 1 hours in every 12 hours continues running confirming to IS: 10000/10002/ISO 3046/ BS: 649/ BS: 554 amended up to date, the Engine shall consist of the following :- (i) Dynamically balanced fly wheel or as per manufacturer's standard (ii) Coolant cooling system complete. (iii) Air cleaner as per manufacturer's standard
(iv) Fuel injectors and fuel pump as per manufacturer's standard (v) Electronic governor as per manufacturer's standard to maintain engine speed at all conditions of load (vi) Fuel service tank of minimum 100 Ltr capacity fabricated from MS sheet with, inlet outlet connections, air vent tap,drain plug, Caliberated level indiactor(gauge), MS fuel piping from tank to engine with valves, unions, reducers, flexible hose connections, mounting pedestals, fuel filters incl all as per manufacturer's design (vii) Dry exhaust manifold with suitable exhaust residential grade, Asbestos rope of suitable size shall be provided as per manufacturer desires for silencer to reduce noise level as per CPCB norms (viii) Static Battery charging unit suitable for 90 Ah battery/battery array 12/24 volt having float, trickle and boost charging feature. Charging should be from utility supply/generator supply as directed by Engr in charge. (b) one/two battery of total capacity 88 Ah connected with copper lugs and minimum 50 sqmm cable placed inside the acoustic enclosure. (ix) Gear driven oil pump for lubricating oil, priming of engine bearing, as well as fuel systems as per manufacturer's recommendation (x) Natually aspirated/ turbo charger as per manufacturer's standard
(xi) Lubricaton oil coolers and filters with replaceable elements as per manufacturer's standard (xii) Crank case heater with manufacturer's recommendation. (xiii) All moving parts of the engine shall be mechanically guarded in such a manner that a human finger cannot touch any moving part. (xiv) Radiator as per manufacturer's standard (xv) Engine control panel having digital display complete with :- (aa) Start/stop key switch. (ab) Lubricating oil pressure indication. (ac) Lubricating oil temperature indication. (ad) Water temperature indication. (ae) RPM indication. (af) Engine hours indication. (ag) Battery charging indication. (ah) Low lub oil trip indication. (aj) High water temp indication. (ak) Over speed indication. (xvi) Any other item not included/specified but is a standard design of the manufacturer. (B) ALTERNATOR (i) Alternator of capacity 15 KVA , 1500 RPM, 0.8 lagging power factor, 3Ph, 415 V, 50 Hz, H Class insulated winding, IP-23 protection, Close-direct-coupled,brushles self-excited and self-regulated type, SPDP enclosure, mounted on rigid MS sheet channel base frame, alternator shall be confirming to IS: 13364, IS: 4722,IS 4889 , IEC: 34 and suitable for tropical condition.
(ii) Type : Brushless Self excited self regulated with automatic voltage regulator (electronic type) (iii) Rating : 15 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed : 1500 RPM (v) System : 415 Volt +/- 5 % AC 3 phase 4 wire 50 Hz. (vi) Connection : 4 wire star connected. (vii) Enclosure : Screen protected drip proof. (viii) Ventilation : Self ventilated (ix) Anti friction bearings. (x) AVR output voltage within +/- 1% (xi) Frequency in range 50+/- 3 %. (xii) Over load capacity and duration: 10 % for 1 hour after each 12 hour continuous operation, 50% for 15 sec. (C) Acoustic Encloser: (i) Shall have Anti viberation mountings for direct mounting of engine alternator assembly. (ii) should be designed to meet CPCB norms for noise level (75dB at 1 mtr). (iii) Construction shall be such ,it prevnets entry of rain water splashing in to the enclosure and allows quick flow of rain water to ground in event of heavy rains. (iv) suitable no of doors shall be privided for easy servicing and part replacment of DG set. (v) It shall be suitable to be dismantled during overhaul of DG. (vi) It shall be suitable for cable entry upto 3.5 core 185 Sqmm XLPE cable. (vii) Inside of enclosure shall be provided with 2x 12 watt lead lamps cotrolled by 5 amp switch supplied from load side of AMF Panel.
(d) CONTROL PANEL The control panel is to be inside canopy and fabricated out of 1.6 mm thick CRCA sheet cubicle type totally enclosed, powder coated, IP-53 protection, equipped with MCCB/cuircuit breaker of suitable capacity, voltage metering & safety, frequency meter metering & safety, ampere metering & safety, fuel level gauge in % metering , Lub oil pressure metering, high water temp metering, engine RPM metering, Power metering, Power factor metering, set of suitable CTs, toggle switch, indicating LED lamps , incoming and outgoing terminals all as specified by manufacturer and directed by Engr-in-Charge. (a) Following engine shutown and alternator protection provisions shall be provided in control panel: (i) Engine: (aa) Low lubercating oil pressure shutdown. It shall be inoperative during starting and accelerating period of engine. (bb) High coolant temp shutdown. (cc) Engine overspeed shutdown. (ii) Alternator: (aa) overload. (ab) Short circuit. (ac) earth fault. (ad) Over voltage. (b) Monitoring and measuring Facility: (aa) Necessary energy analyser unit for visual monitoring of Mains, Alternator and load E11voltage,current, Frequency, power factor, KWH, KW etc. (bb) Visual monitoring lamp indication for load on DG set, Load on Mains, engine shutdown for overspeed, over load trip, earth fault trip, engin lockout and failure to start, all with audio and visual alarm.
(e) AMF panel shall be fully enclosed vermin, dust proof powder coated, 1.6mm thick crca sheet having ingress protection IP42 if housed/ integrated inside the acoustic enclosure. If installed outside acoustic enclosure, AMF Panel shall be 3.15 mm thick CRCA outdoor type having ingress protection of IP 54 as per manufacturers standards. Installation cost shall be included in quoted rates. AMF panel shall have facility of manualy transferring load from mains to generator and vice versa.Note : Generator shall have AMF panel as per standard of manufacurer for automatic starting on mains failure Foundations :- A PCC 1:2:4 M-20 graded foundations of weight 2.5 times the operating weight of genset with enclosure or as recommended by Genset manufacturer OEM/OEA which ever is higher is required to be provided. 300 mm of this foundation height should be above ground level. Length and Breadth of foundations shall be atleast 1 mtr more on all sides than size of enclosures. Design as per recommendation of manufacturer shall be submitted by contractor and get approved before execution of work. Depth of foundation shall be 400 mm. Note :- Rate for foundation shall be included in the quoted rate.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with copper earth plate earth electrode 60 cm x 60 cm x 3.15 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8 m below normal ground level connected to and including cupper earthing strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed including taking down old unserviceable.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc, and provision of brass/copper nuts, bolts washers etc wherever required and making jointsas required 20x3 copper strip coplete all as specified and directed by Enginer-in-Charge.
Mild steel powder corrugated black sheets of size 30 cm width as cable duct trays and similar work cut to size holes punched including round headed screqs clout nails or rixet revets and fixed to wood or steel framing with olain 40 mm lap joints with revetted seams including bending or turning up mitered angles etc as required of 3.15 mm thick sheet complete as specified and directed.
Perforated angle of size 40x40x4 mm powder coated for holding cable trays with complete nuts and bolts and washers to match with the colour with cable tray complete all as specifed and directed.
S&F of MCCB Enclosure for Capacity of 250 Amps MCCB 4 pole including fixing the enclosure on the wall with the help of fastner/nut/bolts/washer and cutting chasing to wall, making good the disturbed surfaces to match with the existing specifications, complete all as specified and as directed.Make : Indoasian cat part No 811989 or equivalent as approved by GE.
S&F for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 250 Amps with breaking capacity 35/36 KA complete all as specified and directed. Make :- Standard/Havells/Schneider/ ABB or equivalent as approved by GE.
S&F 250 watt LED flood light, with IP 66 protection, PF>=0.90, lumen efficiency >=110 Lm/Watt, 5700 k luminaire engergy saving, environmental friendly long life with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation incl taking down old one etc complete as specified and directed Make- HPL cat part No HPLLEDFL25060D/Wipro/Crompton or equivalent approved by GE
S&F DWC HDPE tubing 100 mm bore for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note :- (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates.
S&F off LOAD change over switch 415V, 50 Hz in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and directed by Engr-in-Charge. Make :- Indoasian cat part No OFFPO100 or equivalent as approved by Garrison Engineer.
S&F of Automatic Transfer Switch as per Conforms to IEC:60947-1 and IEC:60947-6-1 four pole ,AC -31A,50 Hz, 415 Volts of capacity 100 amps automatic /manual with inbuilt time delay with enclosure complete.make : Havells ,cat part No. IHYFCDE100/standard/equivalent as approval by GE.
DAVINDER SINGH
ANIKET TRADERS
MOHAN LAL AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .