Loading…
Loading…
Tender Value
₹44.8 L
EMD Value
₹32,500
Closing Date
16 Oct 2026, 3:00 pm
The Superintending Engineer, PWD.,
The Superintending Engineer, PWD., Buildings Construction and Maintenance Circle,Tiruvannamalai-4.
Providing Additional 1 No 26 Person Bed cum Passenger lift to the additional building in the District Headquarters Hospital at Tirukoilur in Kallakurichi District
2026_PWD_709413_1
4/TVM-CLE/26-27/1/ Dt.28.09.2026
Open Tender
Electrical Works
Lump-sum
90 days
Tirukoilur
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹32,500
1 Oct 2026
1 Oct 2026
16 Oct 2026
1 Oct 2026
16 Oct 2026
1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 1 no 26 persons capacity Gearless Bed Cum passenger lift with machine room as per the following Technical specifications.
1.Location: Hospital block 2 Tirukoilur
2.No of lift: 1 No
3.Type of lift: Bed Cum passenger lift (1768 Kgs)
4.Capacity of lift: 26 persons capacity Gearless passenger lift
5.Speed: 1.0 M / Sec
6.Type of drive: Specific variable voltage variable frequency V3F drive with enhanced ride comfort and near zero leveling functions
7.No of floors: 6 (Ground + 5 floors)
8.Total travel: 16.5 mtrs Travel
9.Leveling accuracy: High level accuracy with smooth & jerk free stopping
10. Construction of CAR: 18SWG High qualifty S.S 304 Grade car Neat hairline finish, S.S hand rail, SS floor line finish, Perspex false ceiling, stretcher impact protection.
11. Position of machine: Directly above the lift well.
12. No of landing entrance: one in front (6 Nos)
13. No.of car entrance: one in front only
14.Car entrance door: Power operated V3F drive side opening sliding 18SWG Stainless Steel hair line finish.
15. Landing entrance door: Power operated V3F sliding, opening 18SWG Stainless Steel hair line finish with provision for emergency key.
16. Lift well existing :3000mm x 2400mm
17.Lift pit depth available :1600 mm | 1 | No | - | - |
| 1.01 | 18. Car size (Clear inside):1600mm (wide) x 2400mm (depth)
19. Car clear opening: 1200mm width x 2000mm height
20.Lift machine room available: 4350mm width x 5500mm height
21. Power supply: 400 / 440 3 phase, 50 Cycles / Sec A.C. supply for power and 230 V, 50 Hz, single phase, supply for lighting.
22.Control: Micro processor based simplex selective collective simplex
23. Car fittings: sleek LED light fitting with 300mm sweep cabin fan.
24. Lift well: R.C.C. construction with brick masonry.
25. Indication: UP / DOWN digital direction and position indicator for all landing and in car (25mm Height, seven segment Digital Floor position indicator scrolling type).
26.Emergency Alarm Bell: Battery operated alarm bell to be provided with Automatic charging device
27.Emergency light: Battery operated light to be provided with Automatic charging device
28.Fireman's switch: To be provided at Ground Floor
29. Minor builders work: To be provided by lift contractor.
30. Scaffoldings: To be provided by lift contractor.
31. Sill angles and fascia plates: To be provided by lift contractor.
32. Steel for lift machinery: To be provided by lift contractor.
33. Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by the lift contractor during the guarantee period of one year. | - | - | - | - |
| 1.02 | 34. Automatic Rescue Device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, inverter, under voltage protection system etc., complete with all accessories.
35. Provision for intercom with phone: To be provided by lift contractor 3 points EPABX system at three places vide 1) inside the car 2) Head room 3) at ground floor attender room.
36.Lift license: Preparation of Drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor
37. Floor annunciator with music, included
38.Special features:
a) Infra red door sensor with full height screen
b) Tubular S.S hand rail in cars.
c) Voltage stabilizer for circuit control
d) Stainless steel signal features / fixtures
e) Vendal proof S.S. Button with S.S. cover
f) SS hairline finish door frames for landing doors
g) VF door Register Signal
h) Call register signal
i) Stainless steel fascia plate for car operating panel and landing fixtures
j) Steel ladder for machine room and ladder for lift shaft pit
k) On - off switch for fan and light
l) Over load warning indicator with audio announcement | - | - | - | - |
| 1.03 | m)Fall width half height rear panel mirror
39.Provision of architraves covering all three side up to a width of 300 decorum sheet of plywood with TW frame with aluminium beading architraves should also cover the thickness of still level door frame at the landing and indicator boxes at all landings.
40. Other standard features: Voltage stabilizer for control units, Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, single reduction worm gear, electromagnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limits switch, main suspension ropes counter weights lifting hoist for mounting the machineries.
41. Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period not less than one year.
42. Site testing in accordance with IS 14665 should be carried out at the time of handing over. Necessary spares and tools required for the maintenance for a period of one year
43. Supply operation and maintenance manual with necessary tools for operation. The list of tools required should be detailed by the contractor in a separate sheet duly signed by contractor.
44. Provision of mirror in the lift car
45. All the features for differently abled persons should be included as per the act. | - | - | - | - |
| 2 | GST @ 18% | 1 | No | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
BOQ_852475.xls
BOQ • 0.32 MB
TirukoilurGH_Lift_Cond.pdf
Additional Documents • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .