Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹2.1 L
Closing Date
22 Dec 2025, 3:00 pmClosed
S&T work in connection with Improvement of Model Room at ZRTI, Udaipur.
ZRTI-UD-2025-07~NWR
ZRTI-UD-2025-07
Open
Works - General
9 Months
Udaipur, Rajasthan
₹0
₹2.1 L
22 Dec 2025
27 Nov 2025
8 Dec 2025
Supply of Key Lock Relays (KLCR), 24 V DC, 2F/2B as per RDSO No. IRS:S-46, S-34 &S- 1 23 or latest. Details of ward plates KLCR of all wards manufactured by firm except I and X preferably in equal number are required. Firm shall supply 2 nos. of ward plates extra with each relay in the metallic enclosure. Inspection authority:- For bare relay -RDSO, for key lock housing- consignee Inspection charges:-Borne by Railways Payment Terms:- 100% after supply.
Supply & fixing of KLCR boxes & fixing of KLCR Relays in ASM office. It includes supply 2 of any minor bracket, nuts, bolts, teakwood, sun mica, lock, drilling hole etc as directed by engineer at site. It also includes supply and wiring of push buttons along with LEDs for KLCR circuit. Rly will supply only KLCR relays and contractor has to wire KLCR relays. It includes supply of all the related wiring material. Inspection:Consignee Inspection Charges: None Payment Terms: 100 % after Execution
Supply of Microprocessor based Networkable Analogue Addressable up to 64 nodes 1 Loop Fire Alarm Control panel with LCD display, the panel should be equipped with sufficient nos. of loop as per RDSO Specification No. RDSO/SPN/217/2018 ver 2.0 or latest. Each loop shall have capacity of 127 analogue addressable devices in 1 loop, the panel shall have sufficient nos. of 3 programmable relay control for controlling AHU's, pressurisation fans, ventilation fans at fire pump room, monitoring of fire sprinkler & sealed lead acid batteries sufficient for 24 Hours normal working & then capable of operating the system for 24 Hours during Emergency conditions as required. The panel shall have provision of connectivity of BACNET/ MODBUS/ LONWOK/TCP-IP. The panel shall have dedicated RS232 serial port for direct PC or MODEM connection, optional remote printer as per RDSO Specification No. RDSO/SPN/217/2018 ver 2.0 or latest Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply.
Installation ,Testing and Commissioning of Microprocessor based Networkable Analogue Addressable up to 64 nodes 1 Loop Fire Alarm Control panel with LCD display, the panel 4 should be equipped with sufficient nos. of loop as per RDSO Specification No. RDSO/SPN/217/2018 ver 2.0 or latest. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after commissioning.
Supply of intelligent Analogue Addressable Multi-Sensor type smoke detector with inbuilt fault isolator and integral response indicator with 360 degree viewing angle. Detector shall 5 communicate 3 danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air current. Detector should have unique address for communication and assigned through panel with mounting base as required with the protection category of IP 40. All items as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest. Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply.
Installation, testing and commissioning of intelligent Analogue Addressable Multi- 6 Sensor type smoke detector with inbuilt fault isolator and integral response indicator with 360 degree viewing angle as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest. Inspection: Consignee Inspection Charges:Borne by Railways Payment Terms: 100% after commissioning
Supply of Analogue Addressable Manual Call Point with integral short circuit isolator, 7 Analogue addressable protocol having status LED for alarming & standby mode, Electronically addressed) as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply.
Installation ,Testing and Commissioning of Analogue Addressable Manual Call Point 8 with integral short circuit isolator, Analogue addressable protocol having status LED for alarming & standby mode, Electronically addressed) as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest Inspection: Consignee Inspection Charges: None Payment Terms: 100% after commissioning
Supply of Linear Heat Sensing (LHS) cable as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply.
Installation of Linear Heat sensing (LHS) cable as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution.
Supply of LHS interface module as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest. Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply.
Installation of LHS interface module as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution.
Supply of intelligent Addressable Loop Powered Sounder cum beacon with base inbuilt 13 fault isolator with protection category of IP42 and duly approved as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply.
Installation, testing and commissioning of intelligent Addressable Loop Powered 14 Sounder cum beacon with base inbuilt fault isolator with protection category of IP42 and duly approved as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest Inspection: Consignee Inspection Charges:None Payment Terms: 100% after commissioning.
Supply of Stop Board as per RDSO Drg No 7235/B / Block Section Limit Board/Shunting 15 Limit Board as per RDSO Drg. No. SA2375 (Adv.) . This includes Painting and retro reflective arrangement should be as per SEM. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply.
Supply of Different warning Boards / Calling on Board used for Railway Signalling 16 system as per RDSO Drg. No. SA2380 (Adv). This includes Painting and retro reflective arrangement should be as per SEM. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply.
Fixing of Stop Board, Block section limit Board, Shunting Limit Board, goods warning board , Calling on Board with contractors own material. This excludes supply of Stop Board / Block section limit Board / Goods warning board/Calling on board. The work shall be done as per instruction of Rly Engineer at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation.
Supply of FRLS unarmoured/armouredcable(2Cx1.5 sq.mm) with all accessories for connection of all Fire Alarm devices as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply.
Installation ,Testing and Commissioning of FRLS unarmoured/armouredcable(2Cx1.5 19 sq.mm) with all accessories for connection of all Fire Alarm devices as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest Inspection: Consignee Inspection Charges: None Payment Terms: 100% after commissioning. Unit
B-Schedule 'B' NS items
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CorrigendumofModelRoomWork.pdf
ATTACHMENT
GCCApril2022_1.pdf
ATTACHMENT
ACS1to6ofGCC2022.pdf
ATTACHMENT
ACSNo.7.pdf
ATTACHMENT
ACSNo.8.pdf
ATTACHMENT
ACSNo.9.pdf
ATTACHMENT
ACSNo.10.pdf
ATTACHMENT
ANNEXURE-VVA.pdf
ATTACHMENT
TenderForm_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].