Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.9 L+₹2.4 L (8.36%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹31.8 L+₹3.3 L (11.5%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹32.3 L+₹3.8 L (13.3%)Rejected-Finance BOOTH NO 119 SECTOR 9 PANCHKULA 134109 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134109 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹33.6 L+₹5.1 L (17.8%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-Finance BEING L5 |
Tender Value
₹38.1 L
EMD Value
₹76,300
Closing Date
5 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PATIALA
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact 01712200082
PROVISION OF ELECTRIC INFRASTRUCTURE UPGRADATION AT MIL STN PATIALA UNDER GE NORTH PATIALA
2024_MES_645294_1
CWE/PAT/T-69/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PATIALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE NORTH PATIALA
₹76,300
7 Jun 2024
6 Mar 2024
8 Apr 2024
6 Mar 2024
5 Apr 2024
22 Mar 2024
6 Mar 2024 - 21 Mar 2024
Amount
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of wall, floor and ceiling etc complete all as specified and directed.
Material & Labour for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete for One light/fan point controlled by one switch 6 amp one way complete all as specified and directed. (Switches and regulators shall be measured and paid for separately.) (Wiring shall be done as per colour code in IS for phase, neutral and earth) (Modular cover plate and metal flush boxes quoted rate is included in Point wiring)
All as per Sl item No 2.00 here-in-before but one 5 Amp socket point on same board but with other switch complete all as specified and directed
All as per Sl item No 2.00 here-in-before but one 5 Amp socket point on independent board but with other switch complete all as specified and directed.
All as per Sl item No 2.00 here-in-before but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLSH cable 1100 volt grade and 2.5 sqmm PVC insulated and unsheathed FRLSH cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed.
Material & Labour for modular switch 1 way 6 A, 1 module complete all as specified and directed.
Material & Labour for modular socket, 6A, 2/3 pin combined, 2 module complete all as specified and directed
Material & Labour for modular switch 16 Amps, 1 module with indicator complete all as specified and directed.
Material & Labour for modular socket 16 Amps, 6 pin, 2 module complete all as specified and directed
Supply & Fix fan regulator step type electronic modular type 2 module complete all as specified and directed
Supply & Fix ceiling rose 65x17mm three terminals complete all as specified and directed
Supply & Fix 4 way door closer DB with 200 amps rated bus bar.complete all as specified and directed
Supply & Fix MCB , TPN, 415 Volt , 100 amp, 25 KA class for fixing in DBs including proper thimble connections complete all as specified and directed. (Note: MCB should be B or C curve)
Material & Labour for for highly efficient LED building/security light 25 watt luminaries new generation energy saving & environment friendly with lens made of pressure die cast aluminium alloy housing with toughened glass with IP-66 of protection class,with high power LEDs as light source, having luminous efficiency should not be less than 110 Luminous per watt with active power factor correction (APFC) electronic gear (Heat shrink for better heat transmission) . It shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be from 120 volt to 270 volt AC and frequency range 50Hz and suitable for an ambient temparature from -10°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5sqmm fitted on pole/building with GI bracket of suitable size including taking down of u/s light fitting of any type/size complete all as specified and directed Engr-in-Charge.
Supply & Fix INDUSTRIAL HIGH BAY LED light of capacity 120 W,The LED make must be of > 100 lumen/watt .The driver must be power factor > 0.95 with short circuit protection, open circuit protection , reverse polarity protection, high voltage protection. the luminaire must have secondary optics with perfectly matched lens for better light control with CMRI approved correleted color temperature(CCT) of Emitting light 5700 K with with die cast aluminium housing with heat resistant toughened glass IP 65 protection complete with control gear box and all accessories require to fix the light on wall/structure/pole like clamps nus, bolts etc.complete all as directed by Engr in Charge
Supply & Fix tube light fitting 20 Watt 4 feet long 230 volts with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable of size 23/0.0076 from ceiling rose LED type complete all as specified and directed. NOTE :- (i) luminous efficiency should not be less than 110 Luminous per watt. (ii) For Item No 14 to 16 :- Make of LED Driver should be same as that of luminaire.
Supply & Fix MCCB DB VTPN 4 WAYdouble door 415 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for ways with IP43 protection complete all as specefied and directed. (Note: MCCB should be B or C curve)
Supply & Fix MCCB , TPN, 415 Volt , 125 amp, 25 KA class for fixing in DBs including proper thimble connections complete all as specified and directed. (Note: MCCB should be B or C curve)
Supply & Fix MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 8 ways with IP43 protection complete all as specefied and directed. (Note: MCB should be B or C curve as defined)
Supply & Fix MCBs 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB under item No 17 & 19 above complete all as specified and directed. (DB will be measured and paid separately under respective items of BOQ :- (a) MCB SPN 40 Amps. 'C' curve
(b) All as per Sl item No 20.00 here-in-before but MCB SP 6 to 32 Amps 'B' curve
(c) All as per Sl item No 20.00 here-in-before but MCB SP 40 to 63 Amps 'C' curve
Material & Labour for sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH, stranded copper conductor cable drawn through metallic concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire including taking out old wiring complete all as specified and directed Note:- (i) Two runs of 6.00 Sqmm FRLSH cable and one run of 6.00sqmm FRLSH copper conductor earth wire, conduit and other accessories will be measured as one unit.
Supply and fixing for sub main wiring Four single core PVC insulated and unsheathed FRLSH cable with 10 Sqmm multistrand copper conductor drawing in PVC concealed conduit with 10 Sqmm 2 run PVC copper conductor FRLSH cable as in earth wire system, complete all as directed. Note1: Cutting chases and cementing work measured and paid seperately. 2 : Four runs of 10 sqmm cable alongwith two run of 10 Sqmm PVC insulated unsheathed FRLSH copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed FRLSH cable with 4 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor FRLSH cable as in earth wire system complete all as directed. Note1: Cutting chases and cementing work measured and paid seperately 2 : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
Supply and fixing for sub main wiring Four single core PVC insulated and unsheathed FRLSH cable with 4 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm 2 run PVC copper conductor FRLSH cable as in earth wire system ,including taking out old wiring complete all as directed. Note1: Cutting chases and cementing work measured and paid seperately. 2 : four runs of 4 sqmm cable alongwith two run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed FRLSH cable with 2.5 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 2.5 Sqmm PVC copper conductor cable as in earth wire system incl taking down old wiring complete all as directed. Note 1: Two runs of 2.5 sqmm cable alongwith one run of 2.5 Sqmm PVC insulated unsheathed FRLSH copper conductor as earth wire, conduit and conduit accessories will be measured as one length. 2.Cutting chases and cementing work measured and paid seperately..
Supply and fixing earth metal plug and socket single pole and neutral with a two pin and earth plug and socket alongwith one single pole MCB of 20 Amp concealed in wall complete all as specified and directed.
Supply and fixing industrial 3 phase metal plug and socket, 3 pole and earth plug and socket alongwith one three pole and neutral MCB of 32 Amp concealed in wall complete all as specified and directed
Material & Labour for in replacement of old/damaged earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6) type C1 chamber, pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe,15mm dia, light grade, 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
Supply & Fix exhaust fan 450mm sweep single phase ac 220 V with steel body,blade and suitable size louvers including taking down old unservicable Exhaust fan and depositing the same to MES STORE compelete all as specified and as directed.
Taking down LED tube light fitting 18/20watt hand over to MES STORE and refixing after neccessary cleaning complete all as specified and directed.
Supply and fixing industrial wall mounted metallic body AIR CIRCULATOR 450 mm sweep, 180 watt motor, single phase ac 220 V including taking down old unservicable air circulator and depositing the same to MES STOREcompelete all as specified and as directed.
Supply , installing, testing and commissioning of outdoor type step down transformer 11000/433 volts (at no load), AC , 3 phase 50 Hz , copper wound type complete with standard fittings, 11 KV 3 phase , LT 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS: 1180, EEL2 of capactiy 400 kVA.core type copper wound,oil immersed, naturally cooled, oil nature,air nature(ONAN) with external cooling tubes/fins delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol DYN-11(Vector group)with neutral brought out on secondary side (LV side ) and having tapping at ±5%HV side to be changed by means of hand operated off load tap changer gear. the maximum temparature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temparature of 40 degree celsius. The transformer shall be IS 1180 marked and shall comprise of the following :- (a) 3 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing,copper rods, nut and washers.(b) One cable box on LT side (secondary side ) consisting of 04 No of porcelain bushing with copper rod , complete with nuts and washers with two numbers cable glands suitable for reception /taking out of XLPE insulated heavy duty armoured cable including glands, joints and jointing material complete. (c) Oil conservator with filter type drain valve and oil level gauge (d) Dehydrating breather with first fills dehydrating agents (silca gel) (e) Explosive vent (f) Thermometer pocket on tank cover (g) One number 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius wth metal guard having max perimeter reading temprature indicator with resisting device for transformer (h) Two earthing terminal on tank cover to facilitate fixing of 32x6 mm GI earth strip for earhting of neutral and body (j) Rating plate and terminal marking plate (k) Oil level gauge (l) Oil drain filter valve (m) Lifting legs (n) Oil filling holes with cap/plug with connecting plate complete (o) Air release plug (p) Four plain solid cost steel detachable rollers (q) Extra bushing for neutral, outside LT cable box for proving independent earthig for neutral (r) First filling new and unused transformer oil IS-335/93(forth version) marked (make -HP/power oil or equivalent as approved by GE) filtered and tested dielectric strength at 2.5 mm air gap between testing electrode asper IS 335. Note: (i) Certification of die electric strength shall be submitted by the cotractor after filling the oil. (ii) Transformer will be inspected by the Rep of Accepting Officer before dispatch in factory premises.
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 and applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
Material and labour in replacement fixing, installation, commissioning and testing of switch Air break, Gang operated with 15 insulator switch Triple pole, mechanicaly operated, mounted on insulator and steel frame, for current rating 400 Amp operating Voltage 11 KV out door, vertical mounted type, complete with locking arrengement, assembly with fuse mount carrier and fuse element of required capacity and isolator suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity as required at site and directed by Engr-in-Charge, with DO fuses assembly and one number operating rod of 25 mm dia bore medium grade GI pipe of suitable length, worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD including nut, bolt, washers including taking down existing unservicable set all as specified and directed.
Supply and fix Lightening arrestor Non Lenear metal oxide type conform to IS 3070 (part I) complete with all fittings transmission classes discharge Capacity 65 KA suitable for 11 KV out door type complete all as specified and directed including taking down the existing LA all as specified and directed.
Supply, laying, jointing and testing in replacement XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 11000 volts earthed grade of size 120 Sq mm 3 Core complete all as directed. (Excavation and earth work shall be measured seperately)
Supply, laying, jointing and testing in replacement XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 500 Sq mm 3.5 Core in trenches/ duct/ floor and pole complete all as directed. (Excavation and earth work shall be measured seperately)
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120Sq mm 3.5 Core in trenches/ duct/ floor and pole complete all as directed.(Excavation and earth work shall be measured seperately)
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95Sq mm 3.5 Core in trenches/ duct/ floor and pole complete all as directed.(Excavation and earth work shall be measured seperately)
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70Sq mm 3.5 Core in trenches/ duct/ floor and pole complete all as directed.(Excavation and earth work shall be measured seperately)
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35Sq mm 3.5 Core in trenches/ duct/ floor and pole complete all as directed.(Excavation and earth work shall be measured seperately)
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25Sq mm 4 Core in trenches/ duct/ floor and pole complete all as directed.(Excavation and earth work shall be measured seperately)
Supply , laying , jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sq mm 4 Core in trenches/ duct/ floor and pole complete all as directed.(Excavation and earth work shall be measured seperately)
Material and labour in replacement Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core x XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed.
Material and labour in replacement Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core x XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed.
Material & Labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.30mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 32x6mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type C-1 with PCC cover and 40mm GI pipe light grade for protection, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.
Material & Labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.30mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 25x4mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type C-1 with PCC cover and 40mm GI pipe light grade for protection, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.
Supply and fixing of GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor, roof or road etc all as specified and directed.
Supply and fixing of GI tubing light grade of 40 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor, roof or road etc all as specified and directed.
Supply,Install, Testing and commissioning of self supporting totally enclosed factory fabricated LT feeder pillar box , made out of 3.15 mm thick MS sheet with projected globe roof for rain water protection ,dust and vermin proof, hinged double door shutters with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip, ventilation louvers, bottom detachable gland plate complete with suitable size zink chromium plated nuts, bolts and washers etc outdoor type cubicle panel board suitable for 3 phase 4 wire ,415 volts 50 hz and 50mm x 50mm x 6 mm angle iron frame ,weather proof ventilated with locking arrangement, including provision of suitable size PCC pedestal for mounting of panel board and comprising the following of size not less than 1.2 m X 1.5 m X 0.45m and including taking down the existing feeder pillar panel board. :- Note Excavation and PCC for grouting/fixing of Panel is including in the quoted rate. (i)Aluminium Bus Bar 63 A supported in suitable size porcelain strand lock with suitable size brass nut, bolt and washers with heat shrinkable colour coded PVC sleaving for three phase and neutral -01 Set (ii)MCB TPN 40 A 16 KA 415 Volts 50 Cycles-01 No (as incoming) (iii)MCB TP 10 A 16 KA 415 Volts 50 Cycles-1 Nos(as outgoing) (v)LED Phase Indication Lamp-03 Nos( R,Y,B) with switch control (vi)Contactor set for 3 pole contactor AC-3 phase 40 A 415 Volts (vii)Electro Mechanical Timer Switch 230V ,6 A-01 Nos (viii)The feeder pillar box shall be mounted on PCC pedestal of size 600 mm X400 mm and 700 mm height (02 Nos for each panel board),with cement concrete 1:2:4 type B1 using 20 mm greaded stone aggregate. (ix) The rate quoted shall be demed to include for the above provisions.
Excavation in trenches soft/loose soil n.exe 1.5 mtr wide and beyond 1.5 mtr deep for laying of cables complete all as specified and directed
Returning filling of layers including spreading, leveling complete all as specified and directed
Removing surplus spoil to a distance not exceeding 50 m and depositing where it is directed complete all as specified and directed.
Material and labour for precast concrete cable covers class class HV, type 1 with peak, size 300mm x 180mm x 40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
Material and labour for precast concrete cable covers class class LV, type 1 with peak, size 250mm x 150mm x 40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
Material and labour sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.) complete all as specified and as directed by Engineer-in-Charge. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).
Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 80 mm bore GI tubing and cable etc complete all as specified and as directed.
Dismantling/Taking down old ACSR conductor from LT pole by opening all connections and taking down complete all as specified & directed by Engr-in-charge
Dismantling/Taking down old Transformer opening all connections & depositing to MES Yard complete all as specified & directed by Engr-in-charge
Material and labour for cutting chases for fixing of PVC conduit for point wiring or sub main wiring including repairing the disturbed surface in cement mortar 1:3 and finishing the surface as per existing finish/ treatment all as specified and directed
R D Bansal
SWAMI ENGINEERS
SHARMA ELECTRICAL ENGINEERS
Jawandha Enterprises
Arneja Builders
m/s s.n. builders
Gurcharan Singh Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .