Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹22.9 L
EMD Value
₹45,800
Closing Date
21 Jun 2022, 4:00 pmClosed
Executive Engineer
office of the Ex.Engineer OM KPDCL Division Pulwama
a) Installation of 100 KVA Substation at Ganie Mohallah Aglar(Achgoze) b) Installation of 63 KVA Substation at Qureshi Colony Litter Under PRI Grants 2022-23
2022_PDD_172849_1
OM/PUL/44 of 2022 dated 07-06-2022
Open Tender
Electrical Works
Item Rate
30 days
OM Division KPDCL Pulwama
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,500
Executive Engineer OM Division(KPDCL) Pulwama
₹45,800
24 Jun 2022
7 Jun 2022
22 Jun 2022
7 Jun 2022
21 Jun 2022
7 Jun 2022
Amount
Supply,Installation,Testing & Commissioning (SITC) of 11/0.433kV, 3-phase,100KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV Cable Box having detachable Aluminium Gland plate including carriage/Loading/Unloading of transformer. fresh Transformer should have arrangement for vertical Take off
Supply,Installation,Testing & Commissioning (SITC) of 11/0.433kV, 3-phase,63KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV Cable Box having detachable Aluminium Gland plate including carriage/Loading/Unloading of transformer. fresh Transformer should have arrangement for vertical Take off
SITC of 9 Mtr. Long Pole(ST-410 SP33) along with carriage to site and Loading/Unloading
SITC of 08 Mtr. Long Poles (ST-410 SP15) along with carriage to site and Loading/Unloading
SITC of ACSR 50 sq. mm. Conductor including carriage to site and loading/unloading including site/route clearance along with providing & fixing of Aluminium jointing sleeves at joints.
SITC of G.I Channel/Angle/Flat iron for cross,braces of sizes including clamps and GI Nut Bolts
SITC of 35 mm² AB (HT) Cable (3x35+1x70 mm²) XLPE(11 kV, 3C + Earth)
SITC of Heat Shrinkable Outdoor Cable Termination Kit
Providing and fixing of Suspension/Tension Clamp with eye hook
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC of 11 kV Horn Gap Fuse Set 3 Phase 200A
SITC of 11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
SITC of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
SITC of 185 mm2 Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type including thimbles
SITC of LT Distribution box for 63KVA DTR's with 4 pole MCCB of reqirred ratings(100 Amp. adjustable) for incommer & Outgoing circuits ,(36KA short circuit current Breaking Capacity) of standard quality viz. Havells along with busbars as per drawing
SITC of LT Distribution box for 100KVA DTR's with 4 pole MCCB of reqirred ratings(160 Amp. adjustable) for incommer & Outgoing circuits ,(36KA short circuit current Breaking Capacity) of standard quality viz. Havells along with busbars as per drawing
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
SITC LT Shackles(90X75mm) along with muckhi clamps of G.I flat iron 50X8mm with requirred nut/bolts & washers.
Providing and fixing Danger Plates with Clamps for HT Poles
Supply & Painting of Poles Red Oxide(2-coats)
Supply & Painting of Poles Aluminium Paint(2-coats)
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm as per REC Standard
providing and fixing of anti-climbing devices with clamps for HT Poles
Cement bottoming of poles 1:2:4 mix as per REC standards 0.5cum /pole
Cement bottoming of poles 1:2:4 mix as per REC standards 0.45cum /pole
computerized site plan of work's depicting complete details of works along with land marks on 12X18 inch good quality paper sheet
identification of assets by way of marking of ST poles with Black paint at a height of 2.4 meters from ground level with clear mentioning of name of scheme ,implementation agency (JKPDD),year of work (2022-23) and pole No.
Pre ,during and post GEO tagged photographs of size not less than 8x6 inches on good quality photopaper (along with soft copy ).
M/S T N S ASSOCIATES
AQUARIUSGROUPOFENGINEERS
GH RASOOL WANI
SAPNA TRADERS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .