Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹14.7 L+₹1.3 L (9.54%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹14.8 L+₹1.4 L (10.3%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹15.4 L+₹2.0 L (14.7%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹15.6 L+₹2.2 L (16.7%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L5 | Rejected-Finance High Rate |
Tender Value
Refer Docs
EMD Value
₹40,400
Closing Date
29 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (Central) Pune
Garrison Engineer Central Arjun Marg Pune 411001
8223 MAINT REPAIR TO LT ELECTRIC DISTRIBUTION SYSTEM AND ALLIED ITEMS AT AFMC UNDER GE CENTRAL PUNE
2021_MES_435212_1
8223 MAINT REPAIR TO LT ELECTRIC DISTRIBUION SYSTE
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Garrison Engineer (Central) Pune
As per tender
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹40,400
Yes
28 May 2021
8 Apr 2021
1 May 2021
8 Apr 2021
29 Apr 2021
22 Apr 2021
60 days
Amount
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of LT UG cable in soft/loose soil and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soff / loose soil complete all as specified & directed
Removing excavated soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5m above the starting point all as specified & directed.
M & L for Reinforced concrete pipes of dia 150 mm 2 nos half round (each of 1 RM long for bottom and top) including levelling of ground before laying of pipe complete all as specified and directed.
M & L GI Tubes, 'light grade', galvanised, with all fittings laid in trenches of 50mm bore complete all as specified and directed.
All as per item no 5 here-in-before but 80mm bore.
M & L for Cutting of road/hard standing and making good with PCC (1:2:4) type B1using 20mm graded stone aggregate complete all as specified and directed.
Taking down old unserviceable/worn out LT UG Cables of any type and size complete and removing from site all as directed.
Supply and laying in trenches/ducts/ under plinth protoction/ floors/ passing through pipes or fixed on walls, testing and commissionnig of LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminium conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including all jointing/connecting material as required for following sizes of cable:-
2 Core 10 sqmm cable
4 Core 16 sqmm cable
4 core 25 sqmm cable
3.5 core 50 sqmm cable
3.5 core 95 sqmm cable
3.5 core 120 sqmm cable
3.5 core 185 sqmm cable
S & F in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including suspension wire, one twin core cable flat or circular of size 6.0 sqmm complete all as specified and directed.
All as per item No 10 here-in-before but size of cabe 10.0 sqmm.
M & L for cable jointing kit for 1.1 KV grade cable for outdoor, heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of following sizes:-
25 to 50 sqmm
70 to 120 sqmm
150 to 185 sqmm
M & L for MCCB 63 Amps, 16KA, TPN 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down old one all as specified and directed.
All as per item No 13 here-in-before but 125 amps 25KA, TPN 415 volts.
All as per item No 13 here-in-before but 160 amps 25KA, TPN 415 volts.
All as per item No 13 here-in-before but 250 amps 25KA, TPN 415 volts with adjustable thermal and adjustable magnetic setting.
All as per item No 13 here-in-before but 400 amps 36KA, TPN 415 volts with adjustable over load and adjustable short circuit.
All as per item No 13 here-in-before but 63 amps 16KA, TP 415 volts with adjustable thermal and fixed magnetic setting.
All as per item No 13 here-in-before but 100 amps 16KA, TP 415 volts with adjustable thermal and fixed magnetic setting.
All as per item No 13 here-in-before but 200 amps 25KA, TP 415 volts with adjustable thermal and adjustable magnetic setting.
S & F MCB TPN of rated capacity 32 amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified and directed.
All as per item No 21 here-in-before but 63 amps.
M & L for preparing old painted surfaces by scraping and removing old paints rust etc. from LT panel/ feeder pillar box etc and painting with two coats of synthetic enamel paint complete all as specified and directed.
Supply & Fix in replacement of timer switch box fabricated out of 16SWG CRCA sheet with mounting arrangement duly powder coated to be fixed on the ground by means of PCC foundation as required and consisting of following items including taking down US Panel all as directed (a) Timer FM QT -1 Make - 01 No (b) Power contactor 63 Amps - 01 No (c ) MCB 4 Pole 63 Amps 16 KA 415 Volts-01 No (d) Connector 63 A rating 230V -01Nos
Supply & Fix in replacement of timer switch accessories in Street/Security light timer boxes as per following:-
(a) Timer FM QT
(b) Power contactor 63 Amps
(c) MCB 4 Pole 63 Amps 16 KA 415 Volts
Disconnecting and taking down defective street light fittings of any type/capacity/ brand from steel/ RCC pole at 8/9 mtr height, repairing and refixing after replacing all unserviceable parts including internal wiring all as directed. Note : LED Drivers shall be measured and paid separately.
Supply only electronic driver suitable for LED light fitting 35/40 Watt system power of approved make as directed.
Supply only electronic driver suitable for LED light fitting 60-90 Watt system power of approved make as directed.
Supply only electronic driver suitable for LED flood light fitting 120- 150 Watt system power of approved make as directed.
S & F in repairs Indicator lamps Red/Yellow/Blue (set of three) complete all as directed.
Supply and fix new generation, Bollard light cylindrical in shape with opal acrylic diffuser, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution with high power LEDs as light source of cap 9 watts IP 65 protection as per cat part No BGBOL 605 9W LED of Make Bajaj or equivalent in approved makes including taking down old us light fitting.
Supply and fix new generation, post top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution span aluminium landscape luminaire with high power LEDs as light source of cap 25 watts IP 65 protection as per cat part No RUBYPT25WLED757P SYMTOPC of Make Havells or equivalent in approved makes including taking down old us light fitting.
M&L for plate earthing for sub station equipments (Transformer, lightning arrestor and feeder pillar box) complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of equipments etc at the other, earth strip encased in and including 40mm bore GI medium grade pipe with all fittings from top of electrode to body of equipment fixed with and including 40 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work , etc.complete all as specified and shown in electrical plate No 3 of SSR Pt-I. Note : 1. Refilling of the earth pit shall be carried out with black cotton soil. 2. GI strip 32 x 6 mm & GI protection pipe upto 7.5 m length will be measured and paid under this item.
Sparkh Electricals & Works
M R ENTERPRISES
M/S. Niksun Electro-Infra Private Limited
Rama Electricals
Aim Enterprises
Mahindra Electric Stores
SOURABH ENGINEERS
M/S - SUJIT ELECTRICALS
metro electrical services
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .