Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 CrAccepted-AOC | ₹48.4 Cr Quoted ₹50.2 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹50.3 CrRejected-AOC | ₹50.3 Cr | L2 | Rejected-AOC Rejected |
| 3 | L3₹51.6 CrRejected-AOC | ₹51.6 Cr | L3 | Rejected-AOC Rejected |
| 4 | L4₹54.4 CrRejected-AOC | ₹54.4 Cr | L4 | Rejected-AOC Rejected |
| 5 | L5₹56.8 CrRejected-AOC GYAMDU HOUSE OLD ROAD SHANAM LEH LADHAKH UT PIN 194101 | LEH LADAKH | LADAKH | 194101 | ₹56.8 Cr | L5 | Rejected-AOC Rejected |
Tender Value
₹49 Cr
EMD Value
₹15 L
Closing Date
8 Jan 2022, 6:00 pmClosed
Chief Engineer Lucknow Zone
Chief Engineer Lucknow Zone 17 Cariappa Road Lucknow-226002
PROVISION OF CERTAIN KLP ACCN AT LUCKN
2021_MES_491075_1
CELZ/LKO/T-36 OF 2021-22
Open Tender
Civil Works
900 days
Lucknow
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹3,000
Yes
GE (Project) Lucknow
₹15 L
Yes
26 Feb 2022
29 Nov 2021
10 Jan 2022
29 Nov 2021
8 Jan 2022
3 Jan 2022
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply)
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Road, Path Culvert & Hard Standing)
Total amount of Sch 'A' Part VI (Area Drainage)
Total amount of Sch 'A' Part VII (Compound Wall, Fencing, Gate & Barricading)
Total amount of Sch 'A' Part VIII (Sewage Disposal)
Total amount of Sch 'A' Part IX (Lightening Protection)
Total amount of Sch 'A' Part X (Conduit for Telephone/TV)
Total amount of Sch 'A' Part XI (Solar Water Heater)
Total amount of Sch 'A' Part XII (External Water Supply)
Total amount of Sch 'A' Part XIII (External Electrification)
Total amount of Sch 'A' Part XIV (Rain water harvesting)
Total amount of Sch 'A' Part XV (Arboriculture)
Total amount of Sch 'A' Part XVI (Dismantling/Demolition)
Total amount of Sch 'A' Part XVII (FOOT BALL GROUND, VOLLEY BALL GROUND, BASKET BALL GROUND, HOCKEY GROUND, OPEN BADMINTON COURT, PARADE GROUND, DHOBI GHAT & FIRE POINT)
Sch 'A' Part - XVIII (Miscellaneous Items) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
INTERNAL ELECTRIFICATION M&L for Point wiring complete for One light/Fan/Exhaust Fan point controlled by one switch with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insulated and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for one bell/buzzer point controlled by one push button on the same board with other switches, with PVC insulated and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One light point controlled by two way switches with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete with PVC insulated and unsheathed, FRLS cable 2.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia PVC conduit concealed in wall and MS conduit in roof/floor slab & ceiling, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty pipe shall be used without any extra cost.
M&L for Point wiring complete for one light / fan / exhaust fan controlled by one modular switch with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed. Note :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for one 5 Pin 5 Amp modular socket outlet point on an indpt with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed. Note :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for one bell / buzzer point controlled by one modular bell push button on the same board with other switches with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed. Note :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for one 5 Pin 15 Amp modular socket outlet point on an indpt board with PVC insulated and unsheathed FRLS cable 2.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 2.5 Sqmm(nominal area) PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed. Note :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One light point modular controlled by two way switches with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling,and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed. Note :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost.
M&L for Modular Switch flush type 5/6 Amps single pole Two way complete all as specified and directed.
M&L for Modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed.
M&L for Modular switch 1 way 16A, 1 module, 240 Volts complete all as specified and directed.
M&L for Modular socket 6 A, 5 Pin combined 2 module complete all as specified and directed.
M&L for Modular socket 6/16 A, 5 Pin combined 2 module complete all as specified and directed.
M&L for Modular bell push one module flush type 5 complete all as specified and directed.
M&L for Modular Fan step regulator, 120W 2 module as required complete all as specified and directed.
M&L for Blanking plate for one module complete all as specified and directed.
M&L for Modular type 20 Amps power unit for controllig power equipments including power socket and 20 Amp SP MCB complete all as specified and directed by Engineer-In- Charge. Make:Havells cat part No-AHL0202504 or technocommercially equivalent in SIEMENS.
S & F of AC three phase static energy meter of accuracy class 1.0,3x240 Volt,50 Hz with backlit LCD display of rating 10-60 A (Measures & displays kWh,VI,kW,PF,Hz,last month history of kWh & MD in kW) with special features like TOD,Tamper logging,optical communication port & display in absence of power with transparent hinge type box complete all as specified and directed.
S&F of AC single phase static energy meter of Accuracy class 1.0 ,240 V with backlit LCD display of rating 5-30 A and with 1 push button(measures & display Kwh,kvah,VI,PF,Frequency,KW,KVA,six months history of energy & MD IN kw & kva with transparent hinge type box complete .
M&L for LED light fitting of 10 to 20 watt spot bed light adjustable type wth all fixing arrangement fixed on wall complete all as specified and directed.
M&L for New generation, post top, energy saving LED 40 WATT, aesthetically designed with symmetric light distribution including minimum half meter pole of suitable size dia grouted in PCC and cable connection by means of 3 core 1.5 sqmm copper conductor complete all as specified and directed. Make: BGCT W4LED of BAJAJ, WW or equivalent model of makes mentioned in Appendix 'D'.
S&F of Exhaust Fan high quality engineering plastic, resistant to colour change with anti- statio properties (ventil air) 200 mm sweep with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from celling rose to exhaust fan motor complete all as specified and directed. Make- Havells Model -Ventil Air -DX White or equivalent model of makes mentioned in Appendix 'D'.
S&F of Exhaust Fan high quality mettalic body, resistant to colour change 450 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from celling rose to exhaust fan motor complete all as specified and directed. Make- Bajaj model No Supreme Dlx or equivalent model of makes mentioned in Appendix 'D'.
S&F of Exhaust Fan high quality mettalic body, resistant to colour change with anti- statio properties (ventil air) 300 mm sweep 60 watt ,1380 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from celling rose to exhaust fan motor complete all as specified and directed. Make- Baja model-Freshee MK II or equivalent model of makes mentioned in Appendix 'D'.
S&F of Heavy duty metal body air circulator wall fan 400 mm sweep complete all as specified and directed. Make BAJAJ Model -ESTEEM or equivalent model of makes mentioned in Appendix 'D'.
S&F of Energy saving pressure die-cast aluminium IP 66 roadway luminaire with high power 25 WATT LED with a nominal system output of 85 lum/watt(min) with PF not less than 0.9 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia/suitable dia light grade bend to shape security light fitting with necessary MS clamps 35/40 mm wide and 6 mm in thickness in suitable length not more than 30 CM and Max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminium paint including nuts, bolts and washers complete all as specified and directed. Make: Philips cat part No BRP022 P LED 25 CW SLE S1 PSU GR P4210 or equivalent model of makes mentioned in Appendix 'D'.
S&F of Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with Minimum 8 Watt & Maximum 11 Watt LED warm white in colour with a nominal system output of 120 lum/watt(min) with PF not less than 0.9 complete all as specified and directed.
S&F of Ceiling fan 1200 mm sweep single phase 230V AC, ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including provn of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 mtr long for connection complete all as specified and directed. Make: Bajaj model Electra 50 or equivalent model of makes mentioned in Appendix 'D'.
S&F of MCB 6-32 Amps 3 pole,240V/415 V,50 Hz ,AC with breaking capacity 10 KA ,complete all as specified and directed.
S&F of MCCB 3 pole,415 V ,AC fixed thermal & fixed magnetic setting 63 amps with breaking capacity 10 KA . Ics=100% complete all as specified and directed.
S&F of MCCB 3 pole,415 V ,AC fixed thermal & fixed magnetic setting 100 amps with breaking capacity 10 KA . Ics=100% complete all as specified and directed.
S&F of MCCB 3 pole,415 V ,AC fixed thermal & fixed magnetic setting 125 amps with breaking capacity 10 KA . Ics=100% complete all as specified and directed.
S&F of MCCB 3 pole,415 V ,AC fixed thermal & fixed magnetic setting 200 amps with breaking capacity 35 KA Ics=100% complete all as specified and directed.
S&F of MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCCB and with enclosure blank plates for unused way suitable for 4 ways complete all as specified and directed.
S&F of MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCCB and with enclosure blank plates for unused way suitable for 6 ways complete all as specified and directed.
S&F of MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.
S&F of MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 6 way complete all as specified and directed.
S&F of MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 8 way complete all as specified and directed.
S&F of MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and directed.
S&F of MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 16 way complete all as specified and directed.
S&F of MCB single pole 6 Amps to 32 Amps rating 'B' Series,10 KA 240 Volts,AC complete all as specified and directed.
S&F of MCB single pole 40 Amps to 63 Amps rating 'B' Series,10 KA 240 Volts,AC complete all as specified and directed.
S&F of MCB single pole and nutral 10 Amps to 32 Amps rating 'B' Series,10 KA 240 Volts,AC complete all as specified and directed.
S&F of MCB single pole and nutral 40 Amps rating 'B' Series, 10 KA, 240 Volts, AC complete all as specified and directed.
M&L for Submain wiring with two single core 4 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including 4 sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit.
M&L for Submain wiring with two core 6 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including one 4 sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Two single core 6 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.00 mm dia galvanised iron or steel wire complete all as specifed and directed.
S&F of Glaze wall light decorative wall mounting fixture in durable plastic gold finish including 0.5 watt green and red LED lamp complete all as specified and directed. Make: Havells cat part No-LHFOECE1TZ1B014 or equivalent model of makes mentioned in Appendix 'D'.
Supply and fix pressure die cast aluminium housing LED flood light of 30 watt having lumen output not less than 120 lumen per watt cvomplete all as specified and directed. Make: Havells Cat Part No. JETA NEO LHEPBFUEIN6W030/Philips Cat Part No. BVP120LED 35 CW FG S1 PSU GR or equivalent model of makes mentioned in Appendix 'D'.
S&F of Energy saving sleek and light weight LED batten with high brightness 20 watt LED rod retrofit type with a nominal system output of 85 lim/watt(min) with PF not less than 0.9 providing homogenous illumination, suitable for surface mounting with 4000K integrated high efficiency LED drive>85% non corrosive complete. Make-HAVELLS cat part No LUMLINE PLUS 20W or equivalent model of makes mentioned in Appendix 'D'.
Supply and fixing LED light fitting 9/10 Watt (min 120 lumen/watt), 230 volts, 2 feet, energy efficient type, ceiling/wall mounting Box type fitting with epoxy powder coated CRCA sheet housing with reflector cover channel LED Tube rode with Batten, complete with all accessories internally prewired including PVC insulated three core 23/0.0076 copper cable from ceiling rose to tube light fitting complete all as specified and directed.
Supply and fixing circular slim surface LED Decorative Wall mounting of 12 watts with LED bulb 12 watts complete Polycarbonate housing, globe type glass protection with high transmitivity non yellowing PMMA diffuser for better light output of 120 lumen/watt(min) with PF not less than 0.9 complete as specified and directed.
INTERNAL WATER SUPPLY S&F of CP wall mixer of size 15mm, 3 in 1 with hand shower complete all as specified and directed.
S&F of Health faucet (1.5m tube) with hook (hand spray) with CP body , complete all as specified and directed.
EXTERNAL WATER SUPPLY Construction of fly ash brick masonry valve pit chamber of size 1050 mm X 1050 mm X 1050 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Drilling /Boring hole under existing road for laying GI pipe of dia 80/100 mm as per required depth complete all as specified and directed.
Disconnecting and taking up or down old existing GI tubing of bore 100mm and connections of any description/grade and in any position in trenches/under floors/on walls etc including connected fittings/ accessories all as directed and specified.
Disconnecting and taking up or down old existing Gl tubing of bore 200mm and connections of any description/grade and in any position in trenches/under floors/on walls etc including connected fittings/ accessories all as directed and specified.
Laying only old GI water tubing of size 100mm bore and connections of any description/any grade and in any position obtained from taking downon new route in trenches with using new fittings i.e. bends/Tee/ sockets/ reducers/elbow etc. including cutting/making new threads at the ends of old pipes all as specified and directed:
Laying only old GI water tubing of size 200mm bore and connections of any description/any grade and in any position obtained from taking downon new route in trenches with using new fittings i.e. bends/Tee/ sockets/ reducers/elbow etc. including cutting/making new threads at the ends of old pipes all as specified and directed:
M&L for Ductile iron pipe of size 150 mm dia socketed and spygot ,class ''K-7'' and laid in trenches including rubber gasket joints etc complete all as specified and directed.
M&L for Ductile iron pipe of size 100 mm dia socketed and spygot ,class ''K-7'' and laid in trenches including rubber gasket joints etc complete all as specified and directed.
M&L for Ductile iron pipe of size 80 mm dia socketed and spygot ,class ''K-7'' and laid in trenches including rubber gasket joints etc complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY : Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-55, 11 mtr long, all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply installation, commissioning and testing of transformer copper wound step down 400 KVA out door type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed naturally cooled, delta connected on HV side and star connected in LV side in accordance with vector symbol DY-II with neutral brought out on secondary side and having tapping in step of ± 2 ½ %, ± 5% and ± 7 ½ % to be changed by mean of hand operated OFF load tap changing gear including first fill of transformer oil as per IS-335, and including all fittings/accessories as specified in SSR Part I and as per latest IS-1180-2014 or energy efficient level-3 , trannsformer should have cable box on LT side and exposed brass bushings on HT side, oil temprature gauge,dehydrating breather with first fill of dehydrating agent, oil conservator tank, explosion vent, rating and terminal marking plate, oil level gauge, oil drain and filter valve, providing independent earthings terminals for neutral and body ,PCC foundation complete in all respect and all other standard accessories etc all as specified and directed. The transformer shall be complete in all respect and all other standard accessories etc all as specified with following accessories consisting as per details mentioned in Annexure - A to BOQ. NOTE :- (i) Annexure- A to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order. (iii)Transformer shall be platform mounted as per TD No 699 (Amedment of TD Drg No 699) , chain link fencing around land of size 5125mm x 5125mm x 2000mm(Height) to be provided around the transformer foundation with gate as per TD in lieu of MS flat circular bar and the rates quoted against this item shall be deemed to include for this provision. (iv) The contractor shall arrange factory visit as detailed by accepting officer to check the above transformer.
Supply, laying, jointing, testing and commissioning of HT XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium stranded conductor 11 KV 'Earthed' grade conforming to IS 7098 (Part II) through pipes/ducts/trenches/under floor/under road of size 95 Sqmm 3 core complete all as specified and directed. Make: Havells/Gloster/Polycabs
HT pin type insulator porcelain vitreous white, brown or green including one galvanised mild steel spindle, two GI washer and one GI nut of size 150 mm height, 150 mm dia for 11000 Volt grade complete all as specified and directed.
Lightning arrestor non linear resistor type or expulsion type conforming to IS-3070 (Part-I) complete line discharge or transmission class - 2 nominal discharge current 10 KA & high discharge 100 KA assembly suitable for 11 KV incl all clamps, nuts, bolts & washers and connecting to earth with 32x6 mm size GI strip complete all as specified and directed.
Supply installation, commissioning and testing of switch air break gang operated HT 11 KV triple pole with 12 Nos insulator of 200 amp rating with drop out fuse assembly with fuse carrier, fuse element mounted on insulator and steel frame mechanically (horizontally), vertically operated with operating rod of 25 mm bore medium grade GI pipe of suitable length, worked from ground level and with locking arrangement flat iron clamp of size 50 mm x 6 mm including MS channel of suitable size and length for fixing GOD/DO including bolts, nuts, and washers etc. complete all as specified and directed. Note:- MS work shall be measured and paid separately.
Supplying, fixing, jointing and testing cable jointing kit for 11 KV (earthed) grade cable for straight through cold shrink type joint complete with jointing materials and accessories suitable for HT XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed.
Supplying, fixing, jointing and testing cable jointing kit for 11 KV (earthed) grade cable for outdoor termination cold shrink type joint complete with jointing materials and accessories suitable for HT XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed.
Supply and fixing energy saving pressure die-cast aluminium IP 66 roadway luminaire with high power 70 to 75 watt LED with a nominal system output of 120 lumen/watt(min) with PF not less than 0.9 as light source with toughened glass including two core flexible copper wire of 1.5 sqmm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5m in length and made out of GI tubing 32/40 mm dia/suitable dia light grade bend to shape security light fitting with necessary MS clamp 25mm wide and 6mm in thickness in suitable length not more than 30CM and main length of pipe 1.5 mtr long with one code of anti-corrosive primer and two coats aluminium paint including nuts, bolts and washers complete all as specified and directed. Make:- Philips cat part No BRP032LED 70 CW MR PSU GR DX/Bajaj Cat Part No BRTFG 75W LED 1” or equivalent model of makes mentioned in Appendix 'D'. .
S&F of MS junction box of size 250x200x150 mm made out of MS sheet 16 gauge, duly powder coated ( inside / out side ) complete including MCB SP 0 6 Amp with 4 Nos Aluminium bus bars of 25 mm x 3 mm size, fixed on porcelain support with hinged cover & locking arrangement fixed to electric pole by means of clamps of MS flat iron 25 x 5mm with bolts & nuts complete including electric connection with copper wire of size 1.5 sqmm 2 single core from MS junction to each fitting complete all as specified & directed.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 300 Sqmm 3.5 core complete all as specified and directed. Make: Havells/Gloster/Polycabs.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 240 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 185 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 150 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 95 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 70 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 50 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 35 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 25 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 16 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 16 Sqmm 2 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 4 core complete all as specified and directed. Make: Havells/Gloster/Polycabs.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 2 core complete all as specified and directed. Make: Havells/Gloster/Polycabs.
Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Earthing strip beyond 7.5m shall be measured and paid separately.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick,latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc (For Transformer) and comprising of the following accessories consisting as per details mentioned in Annexure - B to BOQ. NOTE :- (i) Annexure- B to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick/latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc, ( For PANEL No1.) and comprising of the following accessories consisting as per details mentioned in Annexure - C to BOQ. NOTE :- (i) Annexure- C to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick,latest CPRI approved thick duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc( For Panel 2) and comprising of the following accessories consisting as per details mentioned in Annexure - D to BOQ. NOTE :- (i) Annexure- D to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick , latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc and comprising of the following accessories consisting as per details mentioned in Annexure - E to BOQ. NOTE :- (i) Annexure- E to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick , latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc and comprising of the following accessories consisting as per details mentioned in Annexure - F to BOQ. NOTE :- (i) Annexure- F to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick , latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc and comprising of the following accessories consisting as per details mentioned in Annexure - G to BOQ. NOTE :- (i) Annexure- G to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick , latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc and comprising of the following accessories consisting as per details mentioned in Annexure - H to BOQ. NOTE :- (i) Annexure-H to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply and fixing Intefral LED Solar Street light single piece Die-Cast Aluminium Housing reliable & robust construction, minimum system dfficancy of 175 Lm/W and total system lumen min 3000 Lm, System wattage 12V DC, 18 Watts (+/-5%), SMD LEDs with PMMA Lens plant, External built proper heat sinks and UV stabilized polycarbonate cover IP65 & life of LED Luminaire engine should be 50000 hrs along with built in high efficiency MPPT charge controller & driver along with LiFePo4 battey chemistry with cpacity of 256 Wh 7 high efficiency reliable PV Module suitable for even harsh conditions, CCT>5700K, CRI 70. Solar panel module capacity 12V, 35W peak. The fixture should have designed for street light application and should have flexible angle of mounting from 0-15 degree adjustable, Arm & Pole min 6 mtr hight Mount for diverse geographical condition. Factory configured LED's load and PIR Sensor dimming for optimum of autonomy uses upto 24 hrs. Dimming profile should be as from dusk - first 05 hours sensor enabled, next 05 hrs sensor disabled with fixed at 30% brightnessm asnd next till dawn sensor enabled. System should have smart self-diagnostic feature for indicating battery charging, cut off and fault if any. Company logo shall be engraved to avoid any distrusts and complete system should have minimum warranteeof 36 months, Standards Compliance : IEC60598-2-3, IEC 62109-1, EN 50530, IEC 61547, CISPR 15, IEC 62133, IC 61960, UL 1642, & IEC 61730-1,2 & IEC 61215. UPPWD AAA Catefory approval also required. Make - Philips model no BRP710LED20CWMRS1 12VLFPSOLARIN WITH SENSOR or equivalent model of makes mentioned in Appendix 'D'.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine with and including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Relaying old serviceable LT cable of any size complete all as specified and directed. Note: Earth work and sand cushioning will be paid separatel in related items..
Cast iron route indicator of 100 mm dia mark for HT line 11 KV UG cable fixed on 2 fit long MS angle 25x3 mm bend to shape including connected etc & PCC work painting with one coat of red oxide primer and two coat of red paint before fixings complete all as specified and directed.
LIGHTENING PROTECTION : Earthing for machinery, equipments transformer body, transformer neutral, LT feeder pillar box complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not 1ess than 2. 25 mtr below normal GL with the top edge of the plate not less than 1.5 mtr below the ground level connected by GI strip of size 32 x 6 mm thick soldered and revetted to earth plate. Complete with watering pipe 20 mm bore GI pipe (light grade) and chamber PCC (1:4:8) type D2 using 40 mm grade stone aggregate, coping shall be PCC (1:3:6) type C-1 using 20 mm graded stone aggregate and RCC (1:2:4) type B1 using 20 mm graded stone aggregate pit cover 50 mm thick reinforced with 8mm tor MS bar at 80 mm c/c both way including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No . 3 of SSR part and as specified including earth plate packed all sides with charcoal dust, common salt and testing complete including GI sheet funnel, wire mesh etc complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Protection insulator for fixing of aluminium strip complete all as specified and directed.
REFRIGERATOR/ WATER COOLER/ DESERT COOLER/SOLAR WATER HEATER : Refrigerator of capacity 192 liter to 210 liter , electric driven, single phase, 230 volt, AC, 50 Hz including plug top 15 Amps and necessary electric connection complete all as specified and directed.
Refrigerator of capacity 250 upto 330 liter, electric driven, single phase, 230 volt, AC, 50 Hz including plug top 15 Amps and necessary electric connection complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully Stainless steel, electric driven single phase having storage capacity 80 Ltrs & and nominal cooling capacity 40 Ltrs per hour including connection by means of water pipe line, inlet and outlet, PVC pipe connection with brass coupling, nuts at both ends and other necessary fittings including necessary electric connection with and including plug top 15 Amps from voltage stabilizer to water cooler complete all as specified and directed.
Supply & fixing desert cooler electric driven (single phase) PVC front grill, regulator, horizontal and vertical adjustable PVC grill, three side fince type cabinet of min thickness 1.6mm with handle and on/off switch having nominal air flow of capacity 4000 Cum/hour, including water pipe connection with PVC pipe connection having brass coupling nuts at the ends including fixing angle of 32x6mm and PVC float valve and other necessary fittings and electric plug connection with and including plug top 5 Amps complete al as specified and directed. Make of sheet - Jindal/Tata/SAIL Make of Cooler - Champion/Usha/Havells/Crompton
S&F of Voltage stabilizer of capacity 1.0 KVA for automatic operation, single phase naturally air cooled indoor type and designed for input voltage between 170 Volt to 250 Volt with output voltage stabilized at 230 Volts with accuracy of +/- 2.5 % complete all as specified and directed.
S&F of Voltage stabilizer of capacity 5.0 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input voltage between 170 Volt to 250 Volt with output voltage stabilized at 230 Volts with accuracy of +/- 2.5 % complete all as specified and directed.
Supply and install of solar water heating system consisting of flat plate collector box fabricated from aluminium extruded partition by means of gas welding or brazing leak proof fully insulated with glass wool (48 Kg/Cum) with supporting structure duly paint with synthetic enamel black paint over a coat of zinc chromate Red Oxide primer provided with absorber made from copper sheet and copper tubes with protective coating complete with header grommet, storage tank made from stainless steel sheet of minium 20 SWG thickness with puff insulation of minium 50mm girth outer including of 55-26 SWG brass socket and nipple fully insulated with glass wool with cold and hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming of IS-12933 & 12976 with necessary wiring fixed on and including required size PCC platform, cold water tank & make up water tank of capacity 300 liter per day capable to supply hot water at 60 degree celsius complete with 2 kw electric backup including PVC storage water tank three layer of capacity 500 litre for cold water of solar water heater with built up steel stage made of 25x3 mm angle frame of sufficient height complete all as specified and directed.
Supply and install of solar water heating system consisting of flat plate collector box fabricated from aluminium extruded partition by means of gas welding or brazing leak proof fully insulated with glass wool (48 Kg/Cum) with supporting structure duly paint with synthetic enamel black paint over a coat of zinc chromate Red Oxide primer provided with absorber made from copper sheet and copper tubes with protective coating complete with header grommet, storage tank made from stainless steel sheet of minium 20 SWG thickness with puff insulation of minium 50mm girth outer including of 55-26 SWG brass socket and nipple fully insulated with glass wool with cold and hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming of IS-12933 & 12976 with necessary wiring fixed on and including required size PCC platform, cold water tank & make up water tank of capacity 200 liter per day capable to supply hot water at 60 degree celsius complete with 2 kw electric backup including PVC storage water tank three layer of capacity 500 litre for cold water of solar water heater with built up steel stage made of 25x3 mm angle frame of sufficient height complete all as specified and directed.
Supply and install of solar water heating system consisting of flat plate collector box fabricated from aluminium extruded partition by means of gas welding or brazing leak proof fully insulated with glass wool (48 Kg/Cum) with supporting structure duly paint with synthetic enamel black paint over a coat of zinc chromate Red Oxide primer provided with absorber made from copper sheet and copper tubes with protective coating complete with header grommet, storage tank made from stainless steel sheet of minium 20 SWG thickness with puff insulation of minium 50mm girth outer including of 55-26 SWG brass socket and nipple fully insulated with glass wool with cold and hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming of IS-12933 & 12976 with necessary wiring fixed on and including required size PCC platform, cold water tank & make up water tank of capacity 100 liter per day capable to supply hot water at 60 degree celsius complete with 2 kw electric backup including PVC storage water tank three layer of capacity 200 litre for cold water of solar water heater with built up steel stage made of 25x3 mm angle frame of sufficient height complete all as specified and directed.
RAIN WATER HARVESTING (E/M Part) M&L for Plain PVC Pipe, 100 mm dia bore as per IS 12818 including lowering and jointing complete all as specified and directed.
M&L for Screened PVC Pipe 100 mm dia bore as per IS 12818 including lowering and jointing complete all as specified and directed.
Boring 200 mm dia size bore through any kind of soil/ strata by direct rotary method up to and including 90 mtr depth complete all as specified and directed.
Reaming of bore upto 300 mm ( only for recharge well) pilot bore in any kind of soil/ strata including hard stone/boulder by means of direct rotary method complete all as specified and directed.
M & L for Pea Gravel packing of size 06 to 10mm for trail bore of size to be designed by the contractor natural shape brought direct from river bed and packing around the casing pipe to entire depth upto ground level complete all as specified and directed.
Development of bore wells by means of high velocity jetting together with air compressor having capacity not less than 100 PSI for pumping out mud/ dirty water complete all as specified and directed.
M&L for PVC end cap for 100 mm bore pipe complete all as specified and directed.
M&L for Plain PVC bend 87.5 degree for 100 mm bore pipe, with nylon wiremesh for to covering one end complete all as specified and directed.
M&L for Piezometer (Steel Tape 25 mm wide and 50 meter long with plumb) complete all as specified and directed..
BORE WELL : Drilling vertical bore 200 mm dia, from 0 to 60 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.
Drilling vertical bore 200 mm dia, exceeding 60 Mtr but not exceeding 200 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.
Drilling vertical bore 200 mm dia, exceeding 200 Mtr but not exceeding 300 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.
Drilling vertical bore 200 mm dia, exceeding 300 Mtr but not exceeding 480 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 675 mm/525mm , from 0 to 75 Mtr deep below ground level of reaming 675 mm size including all works pertain to boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 525 mm, exceeding 75 Mtr but not exceeding 200 Mtr deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 525 mm, exceeding 200 Mtr but not exceeding 300 Mtr deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 525 mm, exceeding 300 Mtr but not exceeding 480 Mtr deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed.
M&L for Mild steel sheet casing plain ERW casing pipe 350 mm bore, 8 mm thickness, conforming to IS: 4270 -2001, ISI marked, lowering and fixing in position upto required depth in all strata cut into different length including cutting, welding pipe jointed and welded coupler rings through out circumference of the pipe and coupler rings both side as in bore wells complete all as specified and directed. NOTE :- (i) Length of each pipe shall not be less than 2.4 metre except where pipe length required is less than 2.4 meters. (ii) Welding shall be done through out the circumference of the pipe and coupler rings both side.
M&L for Mild steel sheet casing ERW pipe 200 mm bore, 8 mm thickness conforming to IS: 4270 -2001, ISI marked complete and lowering and fixing in position cut into different length including cutting, welding pipe, jointed and welded coupler rings throughout the circumference of after reducing socket 350mm x 200mm bore complete all as specified and directed. Note:- Reducing socket shall be measured and paid seperately.
M&L for V-Strainer (Johnson screen pipe) of size 200 mm bore of thickness 8mm and maximum length of stainer 3 mtr long/ 6 mtr long low carbon galvanised steel, plain beveled ends in built welding slots of size 0.75 mm wide uniformly distributed on surfaces and fixed in position cut into different length including cutting, welding pipe, jointed and welded coupler rings throughout the circumference of pipe complete all as specified and directed.
M&L for Mild steel reducing socket of size 350 mm x 200 mm including welding MS strip of size 40 x 6 mm (02 Nos) on each joint extended 100 mm on each side complete all as specified and directed. Note:- The wall thickness of the Socket side shall not be less than 7.04 mm.
M&L for Well cap of 350 mm dia and 8 mm thick size on top of the pipes with locking arrangement complete all as specified and directed.
M&L for Mild steel bail plug 200 mm size, 10 mm thick of 1 mtr long with MS rod 25 mm dia size welded to it at bottom bail hook complete all as specified and directed.
M&L for Pea gravel of size 3 mm to 6 mm size of approved quality as order to pack around the casing/ slotted pipes in bore well to entire depth upto ground level complete all as specified and directed.
M&L for MS flat iron (Two nos) 150 mm x 16 mm thick size clamp for holding with 350 mm bore housing pipe including casting PCC block of size 1200 mm x 1000 mm x 1000 mm in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate including 150 mm bore MS pipe two Nos each 1.5 Mtr long with cap plug and cap top for feeding pea gravel for each bore well complete all as specified and directed.
M&L for Mild Steel black column pipe 3 mtr long heavy duty 150 mm bore wall thickness 5.4 mm both end flanged with heavy duty MS flange not less than 16 mm thick screwed and welded inside and outside. The flange end making surface shall be made smooth including welding of 04 strip of 5.0 mm thick 25 mm wide and 50 mm long covering pipe and both end flanged having 08 Nos predrilled hole not less than 16 mm including rubber gasket, nut bolts and washer. Pipe shall be duly painted with anti-corrosive paint complete all as specified and directed.
M&L for Strata sample box with glass cover 3 mm thick having internal dimension 1000 mm x 600 mm x 100 mm made out of 20 mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various starta met in boring including strata chart in duplicate complete all as specified and directed.
Electric logging in pilot bore for precise delination of granular zones as also the quality of ground water including report interpretation complete all as specified and directed. Note : Electric logging shall be carried out by any approved Govt Agency.
Chemical and bacteriological testing of sample from approved laborateory to ensure potability of water complete all as specified and directed.
Mild Steel centering guide made out of 40x6 mm and 150 mm length MS flat iron complete all as specified and directed. (Centring guide as contained in IS 2800 Part-I of 1991).
Tail piece made out of MS pipe of size 100 mm X 150 mm, 01 mtr long of wall thickness 5.4 mm both end flanged with suitable MS flange with 08 Nos pre-drilled holes of size 16 mm and welded with 04 Nos strip made out of MS plate of size 5.4 mm thick 25 mm wide and 50 mm long and flanged end pipe shall be duly painted out side only complete all as specified and directed.
S&F of Reflex valve (NRV) both end flanged of size 150 mm (ISI marked) with out by pass arrangement including jointing material, commissioning and testing complete all as specified and directed.
S&F of Cast iron sluice valve of size 150 mm heavy duty both ends flanged class PN 1.6, ISI marked with high tensile brass spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3 mm thick rubber gasket joints etc complete all as specified and directed.
Supply and laying of Submersible cable PVC insulated and PVC sheathed copper conductor of size 16 Sqmm 3 core 1100 volts grade, flat cable conforming to IS 694-1977 including jointing with jointing materials and connections complete all as specified and directed.
Spply installation and testing of granular chlorination dosing pump 0-100 PSI , gear motored having output 2 GDP to 40 GDP , 230 volt , 50Hz ,44 RPM , self priming , NRV,,non metalic PVC connection pipe with connecting nuts , ferrules with all accessories including 100 ltr FRP tank with 50 Kg granuals etc complete all as specified and directed.
M&L for Pressure gauge 150 mm dia of scale 0 to 7 Kg/ Cm2 with flat iron clamp of size 25X3 mm and 15 mm dia socket complete all as directed.
Supply, installation, testing and commissioning of Submersible Pump set with bronze impeller, directly coupled with motor, cast iron body pump, bronze diffusor suitable for 250mm/ 350mm bore hole tube well, water lubricated against total head 90 mtr and discharge 1150 LPM operated on AC 3 Phase 415 Volt minimum motor capacity 30 HP elect supply with and including submersible cable of size 16 sq mm 3 core, two length 5.0 mtr length all as specified and directed.
Development tube well by compressed air with minimum pressure of 10 kg/sqcm and minimum 450 CFM air compressor until sand free colour potable water up to 10 ppm is obtained to get maximum yield and discharge of bore well all as in IS 11189, Para 4.3 complete all as specified and directed. Note:- Compressor, pump, pipe and other allied items will be arranged by contractor and no extra payment will be made by the Dept.
Developing tube wells by over pumping for tube well complete after development by compressor and water shall be used only after receipt of satisfactory test result as per IS, complete all as specified and directed. Note:- (i) Over pumping will be carried out by pumping the water at higher capacity i.e. not less than 50% above the yield of bore well. (ii) Cost of arranging pump and compressor is deemed to be included in the unit rate quoted.
ROAD, PATH, CULVERT & HARD STANDING S & F Round pipe delinators with acrylic reflectors of make 'ROAD STAR' (Gogia Plastics) model No/ Cat part No GRD-100P/Sinor Infrastructure/Dark eye/H2 Safety India/ Green Lite including fixing complete all as specified and directed..
Providing & fixing of Stimsonite Model C-80 ,,Sinor Infrastructure/Dark eye/H2 Safety India/ Green Lite 'Cat Eye' in size of width not exceeding 130mm and height not exceeding 20mm made of strong engineering high impact resistant polymer with electronic welded lenses for retro reflective in dry and wet weather condition with bituminous adhesive along the road complete all as specified and directed.
Providing & laying 2.5 mm thick hot applied thermoplastic road marking material in uniform thickness with glass beads as per clause 803 of MOST specification . The work includes cleaning of road surfaces, heating the material within the specified temperature complete all as specified and as directed.
M&L for Retro reflective sign board made of 2mm thick aluminium sheet, fully covered with high intensity grade retro-reflctive sheeting conforming to ASMT-49601 of blue colour and letter & symbols of white colour shall be made with same high intensity grade retro-reflective aluminium sub shade on both sides of size 1000mm x 750mm rectangular shape including frame work with Stainless steel hollow tube 25mm x 25mm complete all as spefied & directed including following items :- (i) Excavation in post holes n exc 0.50 Cum including RFR and removed in soft/loose soil. (ii) PCC 1:4:8 type D-2 as in foundation filling for grouting the pipe. (iii) PCC 1:2:4 type B-2 as in plinth of size0.45m x 0.45m x 0.30m including three coats of white wash. (iv) MS hollow pipes of 50mm x 50mm vertical members including welding of 40x5mm FI of 300mm long one Nos of fastner/hold fast at bottom of hollow pipe including necessary arrangement for fixing the retro-reflective sign board total length of hollow pipe 1.80m above GL and 0.60m below GL including two coats of synthetic enamel paint over one coat of zinc chrome primer on exposed steel surfaces.
ARBORICULTURE Supply of green live healthy trees/plants of Asoka plant 2 to 3 feet height and planting the same including excavating the pit of size 600 x 600 x 600 mm for planting of tree/plants, removing of rubbish, kanker etc from the excavated soil and mixing with farm yard manure 0.10 cum per pit and chemical @ 30 ml per pit etc. and refilling the same in the pit and planting the plants/trees etc complete including providing the support of bamboo stick for straightening of the plant and making base around the plant with soil for watering and removal surplus soil to a distance n.exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point etc complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Juniper plant 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Cycus plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Revenala plant 1 to 2 feet height paid separately)
Ditto all as per srl no. 19.59 here-in-before but Sacacas Asoka plant 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Tabeberia chrysanthar plant 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Thevelia pereviana (yellow) 2 to 3 feet heightcomplete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Thevelia pereviana (white) 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Thevelia pereviana (pink) 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Calliatenon citrilnos plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Arjun tree 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Bottle brush plant 3 to 4 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Royal palm 4 to 5 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but X mass tree 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Guava plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Mango (Hibreed) plant 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Awla plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Nimboo (Hibreed) plant 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Rat ki rani plant 1.5 to 2 feet complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Brunfelsia plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Crape myrtle 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Duranta 8 to 10 inches height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Plumeria acutifolia 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Sagwan plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Neem plant1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Bouganvillaes All colors plant1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Ditto all as per srl no. 19.59 here-in-before but Amaltash (cassica fistula) plant1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)
Supply and planting of Arancsiria cookeie plant 2 to 3 feet height in earthen pot of 10" along with necessary earth work and manure complete all as specified and directed.
Supply and planting of Chinese fan plam 2 to 3 feet height in earthen pot of 10" along with necessary earth work and manure complete all as specified and directed.
Supply and planting of copper pod plant 2 to 3 feet height in earthen pot of 10" along with necessary earth work and manure complete all as specified and directed.
Supply and planting of Golden dew drop 8 to 10 inches height in earthen pot of 10" along with necessary earth work and manure complete all as specified and directed.
Supply and planting of Ixponica 8 to 10 inches height in earthen pot of 10" along with necessary earth work and manure complete all as specified and directed.
Surface excavation n.exc 30 cm and avg 10 cm and getting out soft/loose soil, Supplying and laying good quality of approved earth mixed with ganga sand (both equal part) for cultivation purpose, 10cm spread thick ness in true level surface including mixing good quality of approved organic manure @ 0.30 cum/10 sqm and chemical 0.10 Ltrs / per sqm all as specified and supply and plantation of Redis cantia (red) 4 to 6 inches carpet grass including watering and removal surplus soil to a distance n.exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point etc complete all as specified and directed. Note : Farm yard manure and chemical to be measured and paid separately.
Surface excavation n.exc 30 cm and avg 10 cm and getting out soft/loose soil, Supplying and laying good quality of approved earth mixed with ganga sand (both equal part) for cultivation purpose, 10cm spread thick ness in true level surface including mixing good quality of approved organic manure @ 0.30 cum/10 sqm and chemical 0.10 Ltrs / per sqm all as specified and supply and plantation of wediha triobata ground cover carpet grass including watering and removal surplus soil to a distance n.exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point etc complete all as specified and directed. Note : Farm yard manure and chemical to be measured and paid separately.
Flexible PVC pipes of 20mm dia including reducer connections for gate valve of 25 mm dia bore & ten numbers water sprinklers all as specified and directed (Gate valve catered separately)
MS circular flat iron tree guard 60cm dia and 1.50m height above ground level made of 3 No 25 mm x 25 mm x 3 mm angle iron verticle 2.0 m long 3 No 25 mm x 3mm flat iron ring 60 cm dia and 1.55 m welded mess 100 mm x 100 mm size of 3.4 mm thick wire bolted together with 8 mm dia 30 cm long S bolt and nuts incl welding etc and painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply only Farm yard Manure for putting in the plant beds complete all as specified and directed.
Supply only Neem cake for putting in the plant beds complete all as specified and directed.
Supply only DAP for putting in the plant beds complete all as specified and directed.
Supply only Furodong for putting in the plant beds complete all as specified and directed.
Supply only Urea for putting in the plant beds complete all as specified and directed.
Supply only Chloropyriphos emulsion concentration 20% EC comforming to IS 3944 for putting in the plant beds complete all as specified and directed.
Supply and stacking good earth at site incl royalty and carriage up to with all lead and left complete all as specified and directed. (good earth qtys measured in stacks, will be reduced by 20% for payment)
Providing, supplying and laying of DWC pipe, Class-SN8 Structured Wall polyethelene Piping systems of 150mm internal dia (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application confirming to IS:16098-2013 including all materials, labours, T&P required for proper completion of work complete all as directed and specified.
Providing, supplying and laying of DWC pipe, Class-SN8 Structured Wall polyethelene Piping systems of 200mm internal dia (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application confirming to IS:16098-2013 including all materials, labours, T&P required for proper completion of work complete all as directed and specified.
Providing, supplying and laying of DWC pipe, Class-SN8 Structured Wall polyethelene Piping systems of 300mm internal dia (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application confirming to IS:16098-2013 including all materials, labours, T&P required for proper completion of work complete all as directed and specified.
Flame proof LED light fittings capacity 36/40 watt complete all as specified and approved.
M & L for point wiring complete for one 5 Pin 6 Amp modular socket outlet point on same board with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia Steel conduit medium grade concealed in wall and Steel conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed ” Note :- In case of roof / ceiling heavy duty Steel Conduit shall be used without any extra cost.
Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI strip 32 x 6 mm as earth electrode bolted or riveted to earth plate at one end and connected to equipment at another end.GI earth strip encased in and including 50 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe, PCC (1:2:4) type B-1 (using 20 mm dia graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:2:4) type B-1 duly reinforced with MS TMT bars 8 mm dia @ 100 c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no. 3 of SSR part I complete all as specified and directed and testing on completion. Note:- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department
Granular class-B type bed to DWC pipe including packing under and haunching against the sides of pipes after they are laid & tested with local sand complete all as specified and directed.
SOLAR PV SYSTEM Supply and installed solar Photo -Voltaic plant for roof top complete of capacity 1X20 KWp without battery backup and on Grid system with following items:-
Mono Crystalline Solar PV Modules 335/340 Wp - IEC 61215, IEC 61730, IEC 61701 (Safety) with inbuilt necessary electronics, Aluminum Frame, 3.5-4.0MM Low Iron Tempered Glass, RFID Tag and Positive Power Tolerance >1%. suitable Nos of Solar Panel for 20 Kwp, Capacity including module mounting structure of Mild Steel hot dipped galvanised (80 Micrones) Structure with Tilt Solar Array, design based on wind speed - 170 Km/Hr as per IS 2062-1992 and IS 4759 standards. Fastener SS type Load on Terrace should be less than 50 Kg/Sqm.
DC MCB DB , Type 2 DC SPD, Transparent Casing IP67 Box for Surge Protection Devices and MCCB Protection for Additional Protection to Invertor.
Inverter/PCU suitable for 20 KWp load - Transformer less inverter with Dual MPPT Technology capable of Peak Efficiency as 98.2%, with IP 65 Outdoor Protection, built in Data Logger, built in DC Switch and strictly as per latest IS, BIS, IEC Standards with inverter earthing of GI Strip/Copper Wire. and Inverter Canopy of Powder Coated Standard Design Inverter canopy for Dust and Weather Protection.
AC MCB DB (Inbuilt Disconnect MCB), Type 2 AC SPD Transparent Casing IP67 Box with Surge Protection Devices and MCCB Protection for Additional Protection to Inverter
Wire and Cables - Appropriate wires of 10 Sqmm multistandard copper cable in heavy duty PVC Conduit not less than 25mm for connecting AC/DC eqpts including MC4 Connectors
Earthing - Earthing for machinery, equipment’s complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2. 25 mtr below normal GL with the top edge of the plate not less than 1.5 mtr below the ground level connected by GI strip of size 32x6 mm thick soldered and reverted to earth plate - 03 Nos.
Lightening arrestor - Lightening arrestor to cover approx 200 M - Dia.
NET Meter 3 phase, 440V including suitable poly carbonate transparent cover.
Cable Lugs, HDPE, Flexible Pipe, Cable Tray and Support other necessary equipment’s should be confirming to latest ISI, IEC Standards.
Makes: Solar PV Moduls - (Waaree/Vikram/Pixon/Adani/Renewsys) Module Mounting Structure - (TATA/Jindal/SAIL) Inverter/PCU - (ABB/Simens/Hitachi) DC/AC Cables - Polycab/Havells/Gloster/Gemscab Industries Ltd ACDB/DCDB/AC & DC Surge Protection - Legard/ABB/L&T NET Meter 3 phase - Secure/L&T/BCH/HPL Note - Solar Panel to be fixed on roof of the Single living Accn of 12 Hav and 64 OR ('B' Block No 01)
SOLAR PV SYSTEM Supply and installed solar Photo -Voltaic plant for roof top complete of capacity 1X15 KWp without battery backup and on Grid system with (the following items:-
Mono Crystalline Solar PV Modules 335/340 Wp - IEC 61215, IEC 61730, IEC 61701 (Safety) with inbuilt necessary electronics, Aluminum Frame, 3.5-4.0MM Low Iron Tempered Glass, RFID Tag and Positive Power Tolerance >1%. suitable Nos of Solar Panel for 15 Kwp, Capacity including module mounting structure of Mild Steel hot dipped galvanised (80 Micrones) structure with Tilt Solar Array, design based on wind speed - 170 Km/Hr as per IS 2062-1992 and IS 4759 standards. Fastner SS type Load on Terrace should be less than 50 Kg/Sqm.
DC MCB DB , Type 2 DC SPD, (d) AC Transparent Casing IP67 Box for Surge Protection Devices and MCCB Protection for Additional Protection to Invertor.
Inverter/PCU suitable for 15 KWp load - Transformer less inverter with Dual MPPT Technology capable of Peak Efficiency as 98.2%, with IP 65 Outdoor Protection, built in Data Logger, built in DC Switch and strictly as per latest IS, BIS, IEC Standards with inverter earthing of GI Strip/Copper Wire. and Inverter Canopy of Powder Coated Standard Design Inverter canopy for Dust and Weather Protection.
AC MCB DB (Inbuilt Disconnect MCB), Type 2 AC SPD Transparent Casing IP67 Box with Surge Protection Devices and MCCB Protection for Additional Protection to Inverter
Wire and Cables - Appropriate wires of 10 Sqmm multistandard copper cable in heavy duty PVC Conduit not less than 25mm for connecting AC/DC eqpts including MC4 Connectors
Earthing - Earthing for machinery, equipment’s complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2. 25 mtr below normal GL with the top edge of the plate not less than 1.5 mtr below the ground level connected by GI strip of size 32x6 mm thick soldered and reverted to earth plate - 03 Nos
Lightening arrestor - Lightening arrestor to cover approx 200 M - Dia.
NET Meter 3 phase, 440V including suitable poly carbonate transparent cover
Cable Lugs, HDPE, Flexible Pipe, Cable Tray and Support other necessary equipment’s should be confirming to latest ISI, IEC Standards.
Makes: Solar PV Moduls - (Waaree/Vikram/Pixon/Adani/Renewsys) Module Mounting Structure - (TATA/Jindal/SAIL) Inverter/PCU - (ABB/Simens/Hitachi) DC/AC Cables - Polycab/Havells/Gloster/Gemscab Industries Ltd ACDB/DCDB/AC & DC Surge Protection - Legard/ABB/L&T NET Meter 3 phase - Secure/L&T/BCH/HPL Note -Solar Panel to be fixed on roof of the Single living Accn of 10 Hav and 72 OR ('A' Block), Single living Accn of 12 Hav and 64 OR ('B' Block no 03) and Single living Accn of 10 Hav and 65 OR ('C' Block)
TREES CUTTING AND DISPOSAL Cutting of trees girth of tree exceeding 30 cm and not exceeding 100 mm girth including cutting of trunk and branches and Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, and removing of material from the work site and clearing site complete all as specified and directed. Note : Srl No 1 to 101 only of clause 35 of particulaer specification shall covered under this item..
Cutting of trees girth of tree exceeding 100 cm and not exceeding 150 mm girth including cutting of trunk and branches and Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, and removing of material from the work site and clearing site complete all as specified and directed. Note : Srl No 102 to 145 only of clause 35 of particulaer specification shall covered under this item..
Cutting of trees girth of tree exceeding 150 cm and not exceeding 200 mm girth including cutting of trunk and branches and Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, and removing of material from the work site and clearing site complete all as specified and directed. Note : Srl No 146 to 169 only of clause 35 of particulaer specification shall covered under this item..
Cutting of trees girth of tree exceeding 200 cm and not exceeding 250 mm girth including cutting of trunk and branches and Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, and removing of material from the work site and clearing site complete all as specified and directed. Note : Srl No 170 to 191 only of clause 35 of particulaer specification shall covered under this item..
Cutting of trees girth of tree exceeding 250 cm and not exceeding 300 mm girth including cutting of trunk and branches and Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, and removing of material from the work site and clearing site complete all as specified and directed. Note : Srl No 192 to 198 only of clause 35 of particulaer specification shall covered under this item..
Cutting of trees girth of tree exceeding 300 cm and not exceeding 450 mm girth including cutting of trunk and branches and Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, and removing of material from the work site and clearing site complete all as specified and directed. Note : Srl No 199 to 201 only of clause 35 of particulaer specification shall covered under this item..
Supply, assembling and grouting complete basket ball pole set(Pair) made out of 150mm dia heavy duty pipe, board of fiber glass board size 1.80mx1.05mx18mm thick with angle iron 35x35x5mm frame and Dunkin rings with Net etc complete all as per standard specifications and directed.
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on same board, with PVC insulated and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
MANGLA AMIT BUILDERS PVT LTD
ENGINEER CONSTRUCTION PVT. LTD.
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
Taru Enterprises Pvt Ltd
surendra infrastructure pvt ltd
GANGA INFRABUILD PVT LTD
SAWHNEY BUILDWELL LLP
RAGHUSONS INFRA ENGINEERING PVT. LTD
Agarwal Jagdish Construction Company Pvt. Ltd.
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
Komal Buildcon Pvt. Ltd.
Som Projects Pvt Ltd
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid