SE OMC-III DTPS HTPS Kasimpur
Office of the OMC-III DTPS HTPS Kasimpur Aligarh
Maintenance of various C and I System and associated Equipment installed at Boiler, Turbine and BOP area of 2x250 MW Units and 1x110 MW units of HTPS Kasimpur for a period of 02 years, as per scope of work
2024_RVUNL_987250_1
ET-02 OMC-III CIMD-I Hdj DTPS 2024-25
Open Tender
Power/Energy Projects/Products
Fixed-rate
730 days
HTPS Kasimpur Aligarh
As per Tender Specifications
2 documents required · 2 mandatory
₹3,540
SAO CFABO HTPS Kasimpur Aligarh
₹1.1 L
Office of the SE OMC-III DTPS HTPS Kasimpur
17 May 2025
26 Dec 2024
2 May 2025
26 Dec 2024
1 May 2025
26 Dec 2024
26 Dec 2024 - 28 Apr 2025
28 Apr 2025
Amount
Work pertains to 2x250MW, DTPS (Preventive & Breakdown Maintenances)
PART-A Preventive maintenance:-
SAFE FLAME SCANNERS
HEA Igniter
240 VAC/220 VDC solenoid actuators for oil, steam, air & scavenge valve and 240VAC solenoid operated gate
SADC (SECONDARY AIR DAMPER CONTROL)
Gravimetric RC Feeders
Max – DCS System
Pneumatics Actuator
Solenoid valves
POWER CYLINDER
UPS & BATTERY SYSTEM
Field Instruments
Hydrastep and its ckt. (BHEL vision -20M for drum level)
Annunciation system and Unit Control Panel
VMS System
HP Bypass & LP Bypass system
Turbovisory A)Vibration probes B)Differential C) Expansion probes D)Axial shift probes E)Speed sensor
Turbine control A) Turbine interlock and protection B) EHTC
Auxiliaries control A) Auxiliary interlock and protection B) Auto control loops
PART-B Breakdown maintenance:-
SAFE FLAME SCANNERS CALIBRATION
CHECKING OF IGNITOR SPARK TIP /CORNER
Gravimetric RC Feeders Calibration Assistant and Checking
Pneumatics Actuator
Solenoid valves
POWER CYLINDER
Field Instruments
REPLACEMENT OF ELECTRODES IN HYDRASTEP
LIMIT SWITCH MAINTENANCE
ELECTRICAL ACTUATORS/STROKE CONTROLLER
Replacement of vibration probe of VMS
Cable laying as and when required.
Breakdown maintenance fo 0.4 KV modules and closed loop circuit of Soot blower .
Checking, servicing/repairing of Limit Switches, push buttons, ON/OFF contacts and checking of control cable &power cable as and when required.
Overhauling of soot blower motors along with repairing of DE/NDE bearing seat, DE/NDE side motor end covers and key groove on rotor shaft.
Replacement of terminal plate , motor end covers , grease plate and groove key if found damaged.
Servicing/seal kit replacement of power cylinder of HAG & Feeder O/L gate, SADC & Burner tilt.
Servicing/calibration of positioner used in SADC, burner tilt.
Servicing/calibration of I/P used in SADC, burner tilt.
Servicing/calibration of air filter regulator, air lock relay used in SADC, burner tilt.
HP Bypass & LP Bypass system
Work pertain to 1x110 MW, CTPS (Routine , Preventive & Breakdown Maintenances)
Round the clock routine operation, checking, periodic logging, healthiness, safeness of C&I system in reserve condition of 1x110 MW Unit No.#07, Harduaganj Thermal Power Station,under jurisdiction of C&IMD-I, DTPS
Round the clock routine operation, checking, periodic logging, healthiness, safeness of C&I system in reserve condition of 1x110 MW Unit No.#07, Harduaganj Thermal Power Station, under jurisdiction of C&IMD-II, DTPS
Round the clock operation, routine&Preventive maintenance of C&I system in running condition of 1x110 MW Unit No.#07, Harduaganj Thermal Power Station, under jurisdiction of C&IMD-I, DTPS
Round the clock operation, routine&Preventive maintenance of C&I system in running condition of 1x110 MW Unit No.#07, Harduaganj Thermal Power Station, under jurisdiction of C&IMD-II, DTPS
Up-keeping & Cleaning of all the C&I equipment, including floor cleaning of various PLC/ UPS/ AC Rooms of UCR &/ EWS/Lab/ Battery/SWAS/AC Chiller plant & AHU Room Analyzer rooms etc. of 1x110 MW Unit No.#07, H.T.P.S., Kasimpur, as per scope of work under jurisdiction of C&IMD-II, DTPS
Work pertain to Preventive & Breakdown maintenance of Hirel-Hitachi make UPS System for DTPS & CTP
Preventive Maintenance Services, 06 Visits (Four Monthly)/(01 man x 2days/visit) as per scope of work for DTPS for a period of 02 years (Non Comprehensive AMC) related to C&IMD-I&II div.
Preventive Maintenance Services, 06 Visits (Four Monthly)/(01 man x 1days/visit) as per scope of work for CTPS for a period of 02 years (Non Comprehensive AMC) related to C&IMD-I div.
Breakdown Maintenance Services, 04 Visits (as and when required)/(01 man x 1days/visit) as per scope of work for DTPS as per site requirement for a period of 02 years(Non Comprehensive AMC) related to C&IMD-I&II div.
Breakdown Maintenance Services, 02 Visits (as and when required)/(01 man x 1days/visit) as per scope of work for CTPS as per site requirement for a period of 02 years (Non Comprehensive AMC) related to C&IMD-I div.
M/S SANJAY ELECTRONICS (BID ID -4888868)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .