| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹14.4 L+₹42,067 (3.01%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹14.5 L+₹50,760.48 (3.63%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹15.9 L+₹1.9 L (13.7%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
1 Jun 2021, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Outsourcing of resources for operation and management of 11 KV Sub Station of 15 AF Hospital at Air Force Station Jaisalmer
2021_MES_441097_1
8718/GE/E8
Open Tender
Miscellaneous Works
Item Rate
335 days
GE (AF) Jaisalmer
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹40,000
Yes
19 Jun 2021
7 May 2021
3 Jun 2021
7 May 2021
1 Jun 2021
20 May 2021
Amount
Schedule 'A' Part-I General Note as applicable for serial item No 2.00 of BoQ/Sch 'A' Part-I Contractors attention is hereby invited that estimated cost of serial item No. 2.00 is Rs. 8,52,240.00 based on prevailing rates of Schedule of Minimum fair wages. Quoted amount against serial item No. 2.00 is less than the amount the work (Estimated of serial item No. 2.00 of BoQ/Sch 'A' Part-I) then lowest bidder will have to deposit FDR in favour of Accepting Officer within 07 days from financial bid opened difference in Estimated cost & quoted amount of serial item No. 2.00, in case lowest bidder said FDR is not submitted within stipulated period as mentioned above. The contractor shall be banned for 06 month & thier bid will be rejected and financial bid will not be opened for next 06 months. FDR submitted by the contractor within 07 days from financial bid opened and the same will be realesed only after satisfactory proof of payment of deployed person under the respective serial item No. 2.00 of Sch 'A' Part-I.
Outsourcing of services for Manning and Operation of 11 KV Sub Station, 15 AF Hospital (One Skilled Electrician) in three shift of 8 hours each for 24 hours continuous operation every day (including Sunday/Holiday) to maintain sub station in/out side HT/LT Panels/LT Complaints as specified, including daily and weekly check-up, monthly quarterly and half yearly maintenance as per Maint. schedule specified under particular specification with all minor consumable and expendable items and labour and tools for smooth and efficient operation all as specified and directed by Engineer-in-Charge. Note for item No. 2.00 (a) The contractor shall take over all equipment in serviceable condition at the time of commencement of contract and shall hand over in the same state at the time of completion of contract period. Any damage/loss shall be made good by the contractor at the time of completion of contract. GE's decision will be final and binding. (b) Daily cleaning of all Panels, transformers, recording meter readings. (c) Daily cleaning of all rooms viz floor, walls and ceiling fan including internal electrical fixtures.
Notes for Serial item No. 2.00 :- (d) No unauthorized person shall be allowed to enter in sub division. (e) 11 KV Sub Station will be operated 24 hours round the clock including Sunday/Hilidays. (f) All T&P insulating cloths, for operatorss, log-books, instruction board duly laminated for 'DO or "NOT DO" Fire safety instruction board etc. shall be provided by the contractor. (g) During maintenance & operation of 11 KV Sub station, any parts found defective and require to be replaced same will be measured under Schedule 'A' Part-II. The fixing charges shall be deemed included in rates quoted under Sch 'A' Part. (h) Contractor shall be responsible for group insurance for eleven month of manpower deployed by him against the contract. (J) Contractor shall provided proper uniform of the operatior as deployed by him and dress code shall be approved by GE/AGE concerned. (k) Daily attendance register shll be maintained by both contractor and concerened JE and register weekly put up to concerned AGE for the record purpose. (l) Labour deployed by the contractor shall be responsible for complete area cleaing of 11 KV installation inside / outside all as specified and directed by Engr-in-Charge. (m) Fuel for operation of DG Sets shall be supplied by the Department as free for filling only. However storage facilities of fuel and collection of fuel from MES Store shall be provided by the contractor.
Schedule 'A' Part-II Lead Acid Battery, 12 Volt, 26 AH capacity, 25 plates with one year warranty, including initial charging and connecting DC cable, thimbles, nut, bolts etc including disconnecting & taking out old unserviceable battery complete all as specified and directed.
Under voltage (UV) coil, shunt coil and tripping coil of capacity 1600 Amp, 415 volt with rupturing capacity of 50 kA and complete with making all connection including taking down old unserviceable complete all as specified and directed
MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 200 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
Air circuit breaker and replacement of complete internal mechanism of existing Air circuit breaker in existing panel of capacity 1600 Amp, 415 volt grade with rupturing capacity 50 KA complete with making all connection complete all as specified and directed.
Making earthing pit on existing old earthing where pit is completely damaged including cover 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm in lieu of CI cover, PCC 1:3:6 type C2 pit/chamber including all necessary excavation and earth work complete all as directed and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 6mm GI strip including taking down old unserviceable complete all as specified and directed. Note : Nut, bolt and other items included in quoted rate by the tenderer.
Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No. 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 50mm bore GI pipe light grade for earth wire protection fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc including taking down old earth complete all as specified and directed. Note : (i) The unit rate shall be deemed to included for Test point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 25 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
Dry sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Supply, fixing, commissioning and testing of automatic operation of street light switch having lighting control through astronomical calculation of sun rise/sun set time by setting data, time and degree of longitude, latitude without of separate light sensor, enclose in sheet metal enclosed metal out of 14 SWG CRCA sheet duly painted and prewired of suitable size duly fixing of angle iron of suitable size including PCC work if required all as specified comprising of the following:- (a) Timer switchmulti functional Astro D21 Make : Legrand Cat Part No 4126 544 - 02 Nos (b) Power contractor 4 Pole 63 Amps Make : Legrand Cat Part No 4125 57 - 01 Nos (c) Auxillary Changeover switch 6 Amp, 250 Volt AC, Make : Legrand Cat Part No 4062 50 - 01 Nos (d) MCB SP 6 Amp 10 kA, 240 volts, Make : Legrand Cat Part No 4085 87 - 01 Nos (e) MCB 4 Pole 63 Amps, 415 volt, 10 KA, Legrand Cat Part No 4087 02 - 01 Nos (f) Flexy DB 03 row of 14 module IP-43 IK-9 with metal door Legrand Cat Part No 5077 12 - 01 Nos
Supply, laying, jointing and testing 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire two single core cables 10 Sqmm including taking down old unserviceable cable complete all as specified.
Digital type voltmeter 0-500 volts, 3 Phase, 50 Hz including taking down old meter complete all as specified and as directed.
Digital type ammeter 0-200 volts, 3 Phase, 50 Hz including taking down old meter complete all as specified and as directed.
Indicator lamps RYB colours including taking down old lamps complete all as specified and as directed.
Current Trasformer (CT) coils of ratio of 600/05 in repari complete all as specified and as directed.
Socket outlet, 2 in 1, 3 pin, 5/6 Amp, flush type, 240 Volts (ISI Marked) in repair complete all as specified and directed.
Socket outlet 2 in 1, 5 pin, 15 Amps flush type, 240 Volts (ISI Marked) in repair complete all as specified and directed.
Switch piano, flush type, single pole, one way, 6 Amp, 230 Volts (ISI Marked) in repair complete all as specified and directed.
Switch piano, flush type, single pole, one way, 15 Amp, 230 Volts (ISI Marked) in repair complete all as specified and directed.
Supply and fixing stepped type electronic fan regulator, flush type and connecting up, ISI marked, 240 Volts including taking down unserviceable complete all as specified.
Lamp holder angular type, PVC/Polycarbonate type with cord grip cap suitable for batten fiitting including taking down unserviceable complete all as specified.
Surface and wall mounted LED tube light fittings of capacity 20 watt, Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver including taking down old unserviceble LED fittings complete all as specified and directed.
Surface and wall mounted LED tube light fittings of capacity 9 watt, basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver including taking down old unserviceble LED fittings complete all as specified and directed.
Ultra modern designed architectural, LED Recessed full open 2X2 Tile, Glare free uniform illumination with longer life and less maintenance, luminaire of capacity 36 watt which provides soft-light and suitable for armstrong/grid ceiling including taking down old unserviceable LED light fittings complete all as specified and directed.
LED flood light fittings on high mast pole pressue die cast housing with IP 66 protection high resistant tempered glass for protection with 5 KV surge protection applicable for large area lighting with efficient high output emitter LED for better distributioin of capacity 170 Watt (6000K CCT) including taking down old unserviceable LED light fittings complete all as specified and directed.
LED Adore 9 watt base capacity B22, STAR Lamp lumen output 665, color temp 3000K including taking down old lamp complete all as specified and directed.
LED Adore 15 watt base capacity B22, STAR ball Lamp lumen output 1425, color temp 6500K including taking down old lamp complete all as specified and directed.
MCB, TPN, 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
MCB, SPN, 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
MCB, Single Pole, 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
Energy efficient LED street light fittings of Capacity 45 Watt, Aerodynamically designed street light with excellent thermal management in built tilt angle arrangement with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 100 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections including taking down old unserviceable complete all as specified and directed. Note :- Driver should be BIS registered with "R" marking.
JAI ENGINEERING COMPANY
M/s Ramesh & Company
M/s Shree Construction Company
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .