Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16.6 LAdmitted-Finance NOT SPECIFIED | -40.57% | ₹16.6 L | L1 | Admitted-Finance |
| 2 | L2₹22.1 LAdmitted-Finance SHAHDARA | DELHI | 110095 | -21.09% | ₹22.1 L | L2 | Admitted-Finance |
Tender Value
₹28.0 L
EMD Value
₹55,996
Closing Date
11 Feb 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (E) PWD EMD SOUTH WEST
O/o Executive Engineer (E) PWD EMD South West Brar Square near Delhi Cantt Metro Station New Delhi
Repairing of High Mast and replacement of LED fittings and detection of cable fault
2026_PWD_286220_1
102/EE(E)/ PWD EMD South West/2025-26
Open Tender
Electrical Works
30 days
works
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹55,996
11 Feb 2026
4 Feb 2026
11 Feb 2026
4 Feb 2026
11 Feb 2026
4 Feb 2026
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000 - 4 - 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK - 10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Detecting of calbe faults in existing LT cables through cable fault locating machine, using the thumping method, a thumper set to thump repeatedly and then walking along the cable route to hear the thumping sound. The higher the DC voltage applied, the louder will be the resulting thump for relatively shorter cables.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp / support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
SITC of 255 Amp Four Pole 2 No. + 2 NC Power Contactor in the existing panel i/c connection cable and thimbling etc complete as required.
SITC of 32 Amp Three Pole (ML-2 or equivalent) Power Contactor in the existing panel i/c connection cable and thimbling etc complete as required.
SITC of Digital Type Timer in the existing panel i/c connection cable and thimbling etc complete as required.
Supplying, Installation, Testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high performance, regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
Supply, installing, testing & commissioning of Reverse Osmosis Purification System with capacity of 50 LPH operating on Single Phase 100 - 250 V AC, 50-60 Hz for providing clean, safe & pure drinking water, multi- Stage Purification Process, Auto flusing of membranes ensures the water purifiers clean themselves from time to time, to maintain good hygiene. Makes water both chemically and micro- biologically potable by reducing hardness, TDS. Heavy metal contaminants and water –borne pathogenic microtganisms, outer body ABS Food Grade Plastic & CRCA Steel, Purified Water recovery minimum 50%, complete connection etc. as required.
SITC of stainless steel self contained drinking water cooler of following specification i/c providing and fixing angle iron frame work made out of 35mm x 35 mm x 6 mm thick angle iron of suitable dimension, making water Intel, outlet and overflow pipe connection etc. complete as reqd. a) Cooling capacity : 150 Ltr/ hour b) Power supply: 230 +/- 10%, 50 Hz Single Phase AC c) Storage capacity : 150 Ltr. d) 1 No. Silt blockers All CPVC pipe connection Between RO to Water cooler and Main outlet of water connections are included in the scope of work
Cutting of hard rock/road/ PCC/Paver Block for laying of UG cable with the help of hilty/ hammer etc. i/c making good by laying in position cement concrete 1:2:4: (1 Cement :2 coars sand : 4 graded stone ) of size 0.2 B x 0.2 D mtr etc. as required.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 50 sq. mm
3½ X 70 sq. mm
3½ X 95 sq. mm
3½ X 120 sq. mm
3½ X 240 sq. mm
Supplying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade aluminium armoured cable of following size etc complete as required.
3½ X 70 sq. mm
3½ X 95 sq. mm
3½ X 120 sq. mm
3½ X 240 sq. mm
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:. :
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape
Providing and fixing of 3 mm phenolic laminated sheets of suitable size on the wall to cover the existing steel conduits fixed on the surface of the walls i/c providing and fixing of 2nd class teak wood wooden moulded beading frames with iron screws, plugs and priming coat on unexposed surface. Due to these surface-mounted conduits, the corridor area looks very untidy, for an aesthetic appearance, the conduits are being covered with phenolic sheet with the help of a wooden frame around them, including drilling, screwing, and painting, etc., at the office of the SDM, Kirby Place etc. complete as required.
Fabrication, Supplying and fixing of wiremesh frame work made out of 40 mmx40mm x5mm thick Angle iron having 40x6mm flat strip & wiremesh 6 swg dia m.s wire with 25mmx75mm space in between mesh & top covered for rain protection by 16 SWG MS Sheet and making main door gate having suitable locking arrangement with godown lock (Frame size shall not be more than 60 cm x 90 cm) i/c grouting with cement concrete & primer and spray painting with super synthetic enamel paint of approved colour quality with heavy duty Godown lock etc as reqd.
Replacement of old unserviceable of the following accessories on the existing high mast suitable for fixing luminaires complete with U clamp of both the ends and of 30 Mtr pole i/c connections, testing, commissioning etc. i/c complete with greasing the pinions, making required holes to fix the same etc complete as required.
Lowering & lifting of 20/30 Mtr High Mast
S S Wire Rope (6 MM)
Fabrication, Designing, Supplying & Fixing of High Mast Ring on the existing 30 mtr High Mast built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding for the installation of High Mast fittings i/c making hole for the fixing of flood light fittings with suitable size nut bolt and washers i/c dismantling the existing demage baracket as per existing design of brackets etc complete as required and as per approved by Engineer-In-Charge. (Similiar type as per existing pole)
Credit for old unserviceable and dismantle material
Wire Rope
Assorted size Aluminium Cable
Assorted size HPSV fittings
Assorted size Timer/Contactor
Assorted size water cooler
Assorted size RO
Old rusted ms angle iron / tube / pipe
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.99 MB
BOQ_378846.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid