Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC 40004093 BINDU KISAN SINGH WARD NO 4 GUJAR KHEDI SAONER NAGPUR 441107 | NAGPUR | MAHARASHTRA | 441107 | L1 | Accepted-AOC Accepted as techno commercially eligible L1 bidder | |
| 2 | L2₹46.4 L+₹4.0 L (9.44%)Rejected-Finance AT BAGHUABOL CHHAK PO HATATOTA TALCHER ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | L2 | Rejected-Finance Rejected as not being L1 bidder | |
| 3 | L3₹53.9 L+₹11.6 L (27.3%)Rejected-Finance | L3 | Rejected-Finance Rejected as not being L1 bidder |
Tender Value
₹48.9 L
EMD Value
₹61,100
Closing Date
11 Mar 2024, 5:00 pmClosed
Chief Manager ENM TA
Office of Chief Manager ENM TA
Miscellaneous Electrical Works for Anand Vihar, MCL HQ (1st Re-tender)
2024_MCL_302757_1
MCL/SAMB/TA/ENM/2023-24/04 DATED 27/02/2024
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Anand Vihar, MCL HQ
Please refer Tender documents.
4 documents required · 4 mandatory
₹61,100
25 Jun 2024
27 Feb 2024
13 Mar 2024
28 Feb 2024
11 Mar 2024
28 Feb 2024
28 Feb 2024 - 4 Mar 2024
Amount
Supply, Fabrication & comissioning of Indoor type Distribution panel board (size 0.5 mtr X 0.5 mtr x 0.5 mtr) of 16 SWG or higher size supporting with MS angle including the accessories like 4 pole 800 Amp MCCB-01 No. etc as required with MCCB of Havells/L&T/ABB/Schneider or of equivalent reputed make
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm
Supply and fixing of 400Amp changeover with suitably fabricated, painted MS angle on wall/ground as required
Supply and fixing of 630 Amp changeover with suitably fabricated, painted MS angle on wall/ground as required
Supply, Fabrication & comissioning of Distribution panel board (size 2 mtr X 0.5 mtr x 0.5 mtr) of 16 SWG or higher size supporting with MS angle including the accessories like 4 pole 400 Amp MCCB-02 Nos & 630Amp MCCB - 03 nos, etc as required with MCCB of Havells/L&T/ABB/Schneider or of equivalent reputed make.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc Above 95 sq. mm and upto 185 sq. mm
Supply and laying of 300mm internal dia hume pipe
Supply, Fabrication & comissioning of Distribution panel board (size 1.2 mtr X 0.7 mtr x 0.5 mtr ) of 16 SWG or higher size supporting with MS angle including the accessories like 200A Bus Bar - 01 no., etc
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm
Supply, Fabrication & comissioning of Distribution panel board (size 0.7 mtr X 0.5 mtr x 0.5 mtr ) of 16 SWG or higher size supporting with MS angle including the accessories like 12 way MCB DB - 01 no., 32A MCB DP - 03 nos., 63A MCB DP - 01 No., 63A MCB TPN - 01 no., 16A 6 pin Sockets - 03 nos.as required with MCB of Havells/L&T/ABB/Schneider or of equivalent reputed make
Supply and fitting of Copper rod of diameter 25 mm of length 50cm for mounting of lightning arrestor finial
Mounting of copper rod over Concrete structure
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing of M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required
Supply of Fire/sand Bucket of 04 nos. set with suitable bucket stand
Supplying and fixing of Double arm bracket of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying and fixing of four arm bracket of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 120 sq. mm
TOWER SHIFTING
Dismantling of high mast lighting tower along with light fittings, lantern carriage and all other accessories.
Making foundation for High Mast Tower with including exaction for foundation, rod cutting, bending & binding, ut bolting with template & Anchor plate with filling the exacavated protion with supply of all suitable accessories
Transportation and Erection of high mast lghting tower along with Light fittings, lantern carriage and all other accessories
Testing and commissioning of High Mast Lighting Tower
Supply & Erection of GOAB switch 400Amp, triple pole, 11KV grade double break, 3 post insulator per phase, horizontal type
Supply & Erection of DO/HG fuse with post insulator 400Amp, 11 KV grade
Feeder Pillar - Outdoor type
STREET LIGHT POLE
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (Above 8.00 metre and upto 11.00 metre)
Painting of street light pole of 8 to 10 meters height including arm and pole box with one coat of red oxide primer and two or more coat of aluminium paint of reputed make including cost of cleaning of the pole by emery paper and wire brush etc as required
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
Supplying and fixing metal box of 200mm x 150mm x 100mm on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting, terminal block, 10A Kitkat Fuse, Clamp, Cable gland, etc as required.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying, installation, testing and commissioning of Astronomical timer switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. : 3 output (1 output per phase) and suitable for three phase supply
Supply & Fixing of 3 pole, 32A capacity of coil voltage of 220A AC Air Break Contactor
earthing with maintenance free chemical earting elctrode (copper) pipe 50mm dia & 3 mtr in length as secondary electrode with brown bitumin 2 bags of 25 Kg each, with 50 x 5 mm copper flat of 20 mtrs with sufficient number of nuts and bolts
Supply of Motor Protection Relay having Thermal overload, earth fault, single phasing preventer, locked rotor, under current, currrent unbalance, phase sequence reversal facilities of L&T/Schneider/ABB or equivalent reputed make
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/S INDUSTRIAL ENGINEERING WORKS
SATYANARAYAN SAHOO
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .