Loading…
Loading…
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Sept 2026, 6:00 pm
Garrison Engineer (N) Mamun
Garrison Engineer (N) Mamun PIN-145001 (PB)
REPAIR AND MAINT OF E/M INSTALLATION UNDER AGE E/M-I OF GE (N) MAMUN
2026_MES_784833_1
GE(N)/M-40/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (N) Mamun
₹40,000
18 Aug 2026
18 Aug 2026
16 Sept 2026
18 Aug 2026
8 Sept 2026
1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting and taking out LT cable of size up to 300 Sqmm 3.5/4 core from trenches/cable duct/through wall/pole carefully complete all as specifed and directed. (Note: Earth work, sand, bricks will be measured and paid separately). | 415 | RM | - | - |
| 2 | Dismantling and taking down GI Pipe any size/type complete all as specified and directed. | 80 | RM | - | - |
| 3 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth for laying of cables, foundation filling of poles or stays and for rerouting of cables all as spfd and directed. | 20.25 | Cum | - | - |
| 4 | Returning filling, in including spreading , levelling, watering and well ramming in layers not exc 25 cm each all as required. | 10.75 | Cum | - | - |
| 5 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point. | 9.5 | Cum | - | - |
| 6 | Supply, installation testing and commissioning in replacement LT feeder pillar box, outdoor type, floor mounted, made out of CRCA sheet 3.15 mm thick, CPRI approved, conforming to IEC 61439, weather proof,dust and vermin proof, IP -65, powder coated with 8 tank process, with common elecrolytic, sleeve insulated Aluminium bus-bar 300 Amps, 3 phase 4 wire system, 415 volts AC, both sides openable, compartmentalised, double door and locking arrangements for each compartment, prewired with Copper cable not less thatn 1.5 sq mm, provided with danger notice plate, panel mounted on 50x50x6mm angle iron frame with leg 90 cm long, 30 cm embedded and secured in PCC foundation (700x200x300mm -02 Nos). Size of panel shall suitable to accommodate and including the following components :-
(a) MCCB 160 Amps, 4 pole,25 KA, 415 volts, 50 Hz withThermal Magnetic : O/L & S/C protection- 01 No
(b) MCCB 63 Amps, 4 pole,16 KA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 04 Nos
(c) MCB SPN 32 Amps, 16KA, 240 volts, 50 Hz - 01 No
(d) Multifunction function meter (voltage,Amps ) including CTs and LED pilot lamps for phase indication (RYB)- 01 set | 3 | Each | - | - |
| 7 | All as mentioned in item No 6 here in bove but busbar capacity 200 Amps and including the following components:
(a) MCCB 100 Amps, 4 pole,16 KA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 01 No (Incomer)
(b) MCCB 63 Amps, 4 pole,16 KA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 04 Nos
(c) Onload changeover switch, 4 pole,415 volts, 100 Amps-01 No
(d) MCB TPN 32 Amps, 10KA, 415 volts, 50 Hz - 02 Nos
(e) MCB SPN 32 Amps, 10KA, 240 volts, 50 Hz - 03 Nos
(f) Panel mounting socket 3P+N +E 32 Amps with plug top,IP-66 - 01 No
(g) Panel mounting socket 2P+E 32 Amps with plug top,IP-66 - 02 Nos
(h) Multifunction function meter (voltage,Amps ) including CTs and LED pilot lamps for phase indication (RYB)- 01 set | 3 | Each | - | - |
| 8 | All as mentioned in item No 6 here in bove but busbar capacity 200 Amps and including the following components:
(a) MCCB 63 Amps, 4 pole,16 KA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 01 No (Incomer)
(b) MCB TPN 32 Amps, 10KA, 415 volts, 50 Hz - 01 No
(c) MCB SPN 32 Amps, 10KA, 240 volts, 50 Hz - 06 Nos
(d) Panel mounting socket 2P+E 32 Amps with plug top,IP-66 - 04 Nos
(e) Multifunction function meter (voltage,Amps ) including CTs and LED pilot lamps for phase indication (RYB)- 01 set | 2 | Each | - | - |
| 9 | All as mentioned in item No 6 here in bove but busbar capacity 200 Amps and including the following components:
(a) MCCB 100 Amps, 4 pole,25 KA, 415 volts, 50 Hz withThermal Magnetic : O/L & S/C protection- 01 No
(b) MCCB 63 Amps, 4 pole,16 KA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 02 Nos
(c) MCCB 40 Amps, 4 pole,16 KA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 04 Nos
(d) MCB TPN 32 Amps, 10KA, 415 volts, 50 Hz - 01 No
(e) MCB SPN 32 Amps, 16KA, 240 volts, 50 Hz - 01 No
(f) Multifunction function meter (voltage,Amps ) including CTs and LED pilot lamps for phase indication (RYB)- 01 set | 2 | Each | - | - |
| 10 | S&F in replacement MCCB 3 pole 415 volts , fixed type 100 Amps with braking capacity 16 KA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu, including spreadres after taking out old U/S one all as specified and directed. | 3 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tender40.pdf
Tender Documents • 1.02 MB
BOQ_879560.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].