Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹31.1 L+₹2.3 L (8.09%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹32.8 L+₹4.0 L (13.8%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹33.6 L+₹4.8 L (16.5%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹38.6 L+₹9.8 L (33.9%)Rejected-Finance 86 CHAK16 QAZIPURA TANDA RAMPUR UTTAR PRADESH 244925 | RAMPUR | UTTAR PRADESH | 244925 | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | SHREE SHIV SHANKER ENTERPRISE L1 | NOEL ENGINEERS L6 | S S ENTERPRISES L2 | SHRI SAI ENTERPRISES L3 | SUNRISE CONSTRUCTION CO L4 | SHREE JAGDISH FURNITURE CO. L7 | N F ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L fixedin repair Aluminum strip 25x3.15 mm earth continuity conductor or Main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof of high rise bldg or any other indicated and as required by sadles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge. | 1,400 | RM | 90 ₹1,26,000 | 60 ₹84,000 Lowest | 120 ₹1,68,000 | 70 ₹98,000 | 100 ₹1,40,000 | 77 ₹1,07,800 | 80 ₹1,12,000 |
| 2.00 | M&L fixed in repair Copper strip 20x3.15 mm earth continuity conductor or Main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof of high rise bldg and as required by sadles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge. | 600 | RM | 350 ₹2,10,000 | 450 ₹2,70,000 | 200 ₹1,20,000 Lowest | 300 ₹1,80,000 | 300 ₹1,80,000 | 485 ₹2,91,000 | 500 ₹3,00,000 |
| 3.00 | M&L fixed in repair Galvanised iron strip 32x6mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof of high rise bldg and as required by sadles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge. | 1,000 | RM | 60 ₹60,000 Lowest | 160 ₹1,60,000 | 120 ₹1,20,000 | 90 ₹90,000 | 100 ₹1,00,000 | 222 ₹2,22,000 | 140 ₹1,40,000 |
| 4.00 | M&L for repair of Single pointed air termination aluminium rod 12 mm dia 300mm long complete to walls/roof/pipes with suitable clamps of MS bolts and nuts etc required at site, complete all as specified and as directed by Engineer-in-Charge. (MS work will be measured and paid separately). | 200 | Each | 130 ₹26,000 | 150 ₹30,000 | 200 ₹40,000 | 30 ₹6,000 | 10 ₹2,000 Lowest | 111 ₹22,200 | 80 ₹16,000 |
| 5.00 | M&L for repair of Single pointed air termination Copper rod 12 mm dia 300mm long complete to walls/roof/pipes with suitable clamps of MS bolts and nuts etc required at site. Complete all as specified and as directed by Engineer-in-Charge. (MS work will be measured and paid separately). | 50 | Each | 325 ₹16,250 | 350 ₹17,500 | 500 ₹25,000 | 300 ₹15,000 | 200 ₹10,000 Lowest | 777 ₹38,850 | 600 ₹30,000 |
| 6.00 | M & L replacement of 3 core copper conductor of Size 4 Sqmm for obstruction light in over head tank/high rise tower/ bldg including 20mm PVC pipe and sadles etc. not more than distatance of 50 cm between two saddles, complete all as specified and directed by Engineer-in-Charge. | 500 | RM | 62 ₹31,000 Lowest | 150 ₹75,000 | 200 ₹1,00,000 | 120 ₹60,000 | 200 ₹1,00,000 | 205 ₹1,02,500 | 90 ₹45,000 |
| 7.00 | M & L replacement of 3 core copper conductor of Size 6 Sqmm for obstruction light in over head tank/high rise tower/ bldg including 20mm PVC pipe and sadles etc. not more than distatance of 50 cm between two saddles, complete all as specified and directed by Engineer-in-Charge. | 500 | RM | 112 ₹56,000 Lowest | 250 ₹1,25,000 | 250 ₹1,25,000 | 170 ₹85,000 | 250 ₹1,25,000 | 247 ₹1,23,500 | 120 ₹60,000 |
| 8.00 | M&L for copper strip 32x6 mm earth continuity conductor or Main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof of high rise bldg and as required by sadles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge. | 800 | RM | 475 ₹3,80,000 | 850 ₹6,80,000 | 350 ₹2,80,000 Lowest | 725 ₹5,80,000 | 400 ₹3,20,000 | 1,111 ₹8,88,800 | 1,250 ₹10,00,000 |
| 9.00 | Replacement of Gl tubing 40mm bore light grade in trenches/ floor/ fixed along pole for cable/earth strip protection with proper size of clamps nuts and bolts for fixing lighting conductor etc, complete all as specified and directed by the Engineer-in-Charge. | 200 | RM | 275 ₹55,000 | 250 ₹50,000 | 100 ₹20,000 Lowest | 150 ₹30,000 | 400 ₹80,000 | 285 ₹57,000 | 220 ₹44,000 |
| 10.00 | All as per Srl No. 9 above but of size 50mm bore. | 100 | RM | 325 ₹32,500 | 300 ₹30,000 | 200 ₹20,000 | 178.55 ₹17,855 Lowest | 460 ₹46,000 | 310 ₹31,000 | 250 ₹25,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Kameshwar Prasad, IDSE, EE
GE(West), Colaba, Mumbai - 400005
REPAIR/MAINT OF LIGHTING PROTECTION SYSTEM AND OTHER CONNECTED ITEMS OF HIGH RISE BLDG UNDER GE (W) COLABA
2025_MES_727384_1
8112/E8
Open Tender
Civil Works
Item Rate
180 days
GE(West), Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹90,000
10 Oct 2025
22 Aug 2025
22 Sept 2025
22 Aug 2025
20 Sept 2025
6 Sept 2025
Amount
M&L fixedin repair Aluminum strip 25x3.15 mm earth continuity conductor or Main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof of high rise bldg or any other indicated and as required by sadles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge.
M&L fixed in repair Copper strip 20x3.15 mm earth continuity conductor or Main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof of high rise bldg and as required by sadles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge.
M&L fixed in repair Galvanised iron strip 32x6mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof of high rise bldg and as required by sadles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge.
M&L for repair of Single pointed air termination aluminium rod 12 mm dia 300mm long complete to walls/roof/pipes with suitable clamps of MS bolts and nuts etc required at site, complete all as specified and as directed by Engineer-in-Charge. (MS work will be measured and paid separately).
M&L for repair of Single pointed air termination Copper rod 12 mm dia 300mm long complete to walls/roof/pipes with suitable clamps of MS bolts and nuts etc required at site. Complete all as specified and as directed by Engineer-in-Charge. (MS work will be measured and paid separately).
M & L replacement of 3 core copper conductor of Size 4 Sqmm for obstruction light in over head tank/high rise tower/ bldg including 20mm PVC pipe and sadles etc. not more than distatance of 50 cm between two saddles, complete all as specified and directed by Engineer-in-Charge.
M & L replacement of 3 core copper conductor of Size 6 Sqmm for obstruction light in over head tank/high rise tower/ bldg including 20mm PVC pipe and sadles etc. not more than distatance of 50 cm between two saddles, complete all as specified and directed by Engineer-in-Charge.
M&L for copper strip 32x6 mm earth continuity conductor or Main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof of high rise bldg and as required by sadles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge.
Replacement of Gl tubing 40mm bore light grade in trenches/ floor/ fixed along pole for cable/earth strip protection with proper size of clamps nuts and bolts for fixing lighting conductor etc, complete all as specified and directed by the Engineer-in-Charge.
All as per Srl No. 9 above but of size 50mm bore.
Test Point terminal block made of gunmetal or phosphorus bronze size 75X75X25mm drilled and screwed including 03 Nos 8 mm dia long hex head screw, complete all as specified and directed by Engineer-in-Charge.
Replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 mm, thickness not less than 6mm buried directly in ground (earth pit not less than 2.25 mtr deep Below ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead 25 x 3.15 mm dia by means of bolts, nuts, check nuts and washers of GI including PCC pit in PCC 1:2:4 type B-1 angle iron 40x40x3mm frame with pre-cast RCC 1:2:4 type B-1 cover with XPM weight not less than 4kg/sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal, dust and common salt light grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore 5 mtr long and earth wire up to main earthing of pole complete all as shown in Electric Plate No 3 of SSR 2009 Part-I, to achieve earthing resistance within 1 Ohm all as specified and testing on, completion all as specified and directed.
All as per Srl item No. 12 above but using galvanised iron strip 32x6mm upto test point.
M & L for Earthing complete with Copper earth plate electrode 600 x 600 mm, thickness n.less than 6mm buried directly in ground (earth pit not less than 2.25 mtr deep Below ground level) with top edge of the plate n.less than 1.5 mtr below ground level, connected to copper earth lead 25 x 3.15 mm dia by means of bolts, nuts, check nuts and washers of GI including PCC pit in PCC 1:2:4 type B-1 angle iron 40x40x3mm frame with pre-cast RCC 1:2:4 type B-1 cover with XPM weight n.less than 4kg/sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal, dust and common salt light grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore 05 mtr long and earth wire up to main earthing of pole complete all as shown in Electric Plate No 3 of SSR 2009 Part-I, to achieve earthing resistance within 1 Ohm all as specified and testing on, completion all as specified and directed.
S&F Cross arms bracing supports clamps and back plates fabricated from structural steel section including nut, bolts, washers, welded, binding, cold as hot drilling holes for bolts in any shape or size as required painted with two coats of aluminium paint over a coat of red oxide primer after preparation of surface, including taking out old, complete all as specified and directed by the Engineer-in-Charge.
S&F in repair Metal plug clad & socket including MCB SPN 20 Amps, complete all as specified and directed by the Engineer-in-Charge.
M&L for repair galvanised iron strip 25x3.15mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or or buried in ground or drawn in conduit/pipe or fixed to poles in roof of high rise bldg and as required by sadles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge.
M&L of taking down existing aluminum strip 25mmx3.00mm / 32x6mm Gl Strip from the top of bldg /ground (roof down conductor) and keep shape custody (for serviceable strips for re-use ), retrieved, complete all as specified and directed by Engineer-in-Charge.
M&L Making old serviceable strips refined against item no-18 making straight and re-fixing the same in position by wiring screw / gattas /insulators /PCC Block, complete all as specified and directed by Engineer-in-charge.
M&L for Raw salt with mixing in water for existing earthing, complete all as specified and directed by the Engineer-in-Charge.
M&L Funnel suitable for each pit, complete all as specified and directed by the Engineer-in-Charge.
M&L for repair insulator for each strip and fixed arrangement in roof/wall of building for run of strips on it with nuts and bolts, complete all as specified and directed by the Engineer-in-Charge.
M&L dismantling of PCC earth pit chamber and making PCC chamber of size as per electrical plate No 3 of SSR 2009 Part I with PCC (1:2:4) type B1 including RCC cover with suitable handle, complete all as specified and directed by the Engineer-in-Charge.
M&L in replacement of Pit cover, Cl 10mm thick hinged to Cl frame 40x40mm, complete all as specified and directed by the Engineer-in-Charge.
M & L for in replacement of LED Aviation obstruction light 10w over head tanks / Bldg / high mast/Saft pans are as following : (a) Luminaries body : Aviation yellow colored die-cast aluminum alloy housing10 watt. (b) Enclosure : Red colored poly carbonate done secured to housing by 3 Nos screw. (c) Mounting arrangement : 38 mm dia threaded item with lock nets for mounting on pipe above structure. (d) Degree of protection : IP43. (e) GI Pipe 3mtr long with nut bolt clmap and PCC foundation for fixing pipe and light, complete all as specified and directed.
M & L replacement of 2 core copper conductor of Size 2.5 Sqmm for obstruction light in over head tank/high rise tower/ bldg including 20mm pvc pipe and sadles etc. not more than distatance of 50 cm between two saddles, complete all as specified and directed by Engineer-in-Charge.
Material and labour and replacement for Maintenance free Chemical Earthing comprising of 17.2 mm dia molecularly copper bounded 250mm micron on steel electrode 2.5 mtr long each- 03 Nos, earth enhacning soil treatment compound having essential chemical ingradinets such as ionic chemical, dispersion chemical, diffusion chemcial, expansion chemical and bygroscopic chemical to provide stable low resistance for earth terminal to make it maintenance free (25 kg per beg x 3 beg required per set of chmical earthing) HDPE earth pit cover madium duty to withstand 2000 kg load U clamp bolt for connecting copper strp Mimimum size of copper strip 25 X 3 mm-20RM to earth rod and connection, complete all as specified and directed.
M&L sheet metal enclosure 2 way with MCB SPN 16 Amps fixed in high rise bldg, complete all as specified and directed by Engineer-in-Charge.
M&L for replacement in repair refilling of earthing materials charcoal, salt in sufficient quantities at par the satisfaction of Engr - in- Charge for better results in existing earthing, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Sub main wiring, with two run of 2.5 sq mm stranded copper conductor PVC unsheathed FRLSH wire along with 2.5 sq mm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 32 mm dia) for housing the wires including taking down old unserviceable submain with all associated fixtures, complete all as specified and directed by Engineer-in-Charge. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 2.5 sqmm cable and one run of 2.5 sqmm cable with PVC conduite shall be measured as one length.
S&F in repair for wall mounted fan metal body having high speed of sweep size 450 mm, with nuts bolts, fastners including connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement, complete all as specified and directed by Engineer-in-Charge.
Supply, lay in repair trenches, floors, fix on wall/pole, LT UG cable, 1100 volts grade, PVC insulated, with multistranded Copper conductors, armoured with galvanised steel wire or tape, gland, copper lugs etc, of size 10 Sqmm 3 core, confirming to IS specifications suitable for LT panel to motor pump connection including clamp, nut bolt, passing through 20/25mm pipes etc., including cutting of wall / flooring etc with making good sarface, complete all as specified and directed.
S&F in repair monoblock pump 0.5 HP with suitable size sensor for auto cat, with nuts bolts, union, pipe for fixing connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement, complete all as specified and directed.
M&L for Sub main wiring in repair, with two runs of 16 sqmm stranded copper conductor PVC unsheathed FRLSH wire along with 16 sqmm green colour wire as earth continuity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 32 mm dia) for housing the wires from panel / Main DB to house SPN DB, with all associated fixtures, complete all as specified & directed by Engr-in-Charge. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 16 sqmm cable and one run of 16 sqmm cable with PVC conduite shall be measured as one length.
all as per item No. 34 above but 10 Sqmm complete.
S&F in repair shed water proof 2.5 fit x 2.5 fit x 2.5 fit to protect motor from water including 2 fit PCC from ground, 2mm sheet and 50x50x5mm angle iron frame, wooden frame for fixing monoblock pump 0.5 HP and sensor with suitable size locking arrangement, nuts bolts, union, pipe for fixing connecting pump with PVC copper flexible cable and necessary fixing arrangement, complete all as specified and directed.
S S ENTERPRISES (BID ID -3424348)
SHRI SAI ENTERPRISES (BID ID -3425080)
SUNRISE CONSTRUCTION CO (BID ID -3425174)
N F ENTERPRISES (BID ID -3424797)
NOEL ENGINEERS (BID ID -3418293)
SHREE JAGDISH FURNITURE CO. (BID ID -3423044)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .