| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC AT BALU BANKER COLONY PO DHORI BERMO DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | Rejected-Technical 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | - | Rejected-Technical Bid not be opened as per NIT terms | |
| 3 | Rejected-Technical AT PO PICHHARI DIST BOKARO | - | Rejected-Technical Bid not be opened as per NIT terms |
Tender Value
₹4.8 L
EMD Value
₹6,000
Closing Date
21 Mar 2024, 9:00 amClosed
Staff Officer (EnM)
Office of the General Manager, Dhori Area
Work of (A) Replacement of old and damaged service cable and replacement of PVC pipe and junction box boundary light at CISF camp Raja Bunglow (B) Replacement of old and damaged cable for street lighting at Hindustan Bridge under GM unit, Dhori Area.
2024_CCL_304361_6
GM(D)/SO(EnM)/DA/2023-24/151
Open Tender
Electrical and Maintenance Works
Item Wise
7 days
Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
3 Apr 2024
9 Mar 2024
22 Mar 2024
10 Mar 2024
21 Mar 2024
10 Mar 2024
10 Mar 2024 - 14 Mar 2024
Amount
Part A: At CISF camp Raja Bunglow
Wiring for circuit/sub main witing along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surfacel recessed medium class PVC conduit as required 2x10sqmm + 1x10 sqmm earth wire
Supplying and fixing following sizes of medium class PVC condut along with accessories in sunface / recess including cutting the wall and making good the same in case of recessed condult as required, 25 sqmm
Supplying and fixing damps to 32 amps rating 240 voits, 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection testing and commissioning etc as required
Supplying and fixing following way single pole and neutral, sheet steel MCB distribution bosed,240 volts on surface/recess, complete with tinned copper bulbar, earth bar din bar, detachable gland plate, Including esthling etc as required. (But without MCB/ RCCB/ Isolator)
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.6 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 60metres. 2'x15x845*=1690 ×0.0283•47.82 cft
Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. In layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to S0metres 2'x1'x845'-1690cum x0.0283= 46.12cum
Providing and making steel pole collar with cement concrete (1cement :Scoarse sand :6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of polel pipe not to be deducted) Mutting of pole 1.5' x 1.5' x 2'x 14nos - 157mtr x 0.0283= 4.45cum
Supplying and drawing following Sizes of FRLS PVC Insulated copper conductor, single core cable in the existing surfacel recessed steel / PVC conduit as required. 3x2.5x 8q.mm (Power point)
Repairing of 50 watt LED Light
Driver LED light 50 watt
Opening and fitting of LED light top on pole
Junction box with cover plate,
Part B: At Hindustan Bridge
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and drawing of following sizes FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required 4x1.5sq. mm
Supplying and fixing of following sizes of meduim class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 100A
Supplying and fixing of timer switch 100A, 230V
Supplying and fixing of 32mm dia x 2.00 m long GI pipe medium class bracket for mounting of HPSV/HPMV light fittings
Total impact of GST for the purpose of CTC
M/S KUMAR ENTERPRISES
M/s Saloni Sales
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .