Repair of existing OHSR 75 cum
Repair of existing Pump Chambers size 3.05x3.66 M
Provision for one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressure upto 7 kg.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications complete in all respects has been made in this estimate.
Repair of Electric panel board consisting of electric all appliances such as starter, Main Switch, V.M.,A.M., ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. ,complete in all respects as per Specifications.(For 17.50 Bhp Pumping Machinery)
Repair of exting Pumping Machinery of r 17.50 Bhp complete in all respect
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects. (CSR item 28.90)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & inserting sheet, all carriage complete (with the approval of Engineer-in-charge) Class PN-1 as per ISI (CSR item 28.27(A))
150 mm i/d Sluice Valve flanged
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. (CSR item 28.66 (b))
Size (0.90 x 0.90 mtr)
Repair of leakages in Existing pvc pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects
90 mm o/d pvc pipe
110 mm o/d pvc pipe
Deduct credit of old Sluice valves
Minor repair in existing household connection (by Providing & fixing washer (electric welded) in the 15mm union on existing water connection etc.), Where water connections were installed by consumers, but not as per DWSS specifications.
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 mtr, (2.50+2.00 mtrs)including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d uPVCclamp complete.
New Household Connections proposed On Existing / Replaced Pipeline
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 mtr, (2.50+2.00 mtrs) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d uPVC clamp complete.
New Household Connections on new pipe line
Providing, Laying, fixing & jointing of PVC Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Tranches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including excavation & back filling complete as per specifications for more than 3 mtr street width. (CSR item 28.2,28.13,28.18)
PVC Pipe Line 63mm o/d 6 kgf/sq.cm
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class,premium make such as (Jindal Hisar) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. (CSR item 28.36)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & inserting sheet, all carriage complete (with the approval of Engineer-in-charge) Class PN-1 as per ISI (CSR item 28.27 (A)
80 mm i/d Sluice Valve flanged
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. (CSR item 28.66)
Size (0.60 x 0.60 mtr)
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Connection of new pipe line with existing pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .