Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹27.0 L+₹2.6 L (10.8%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹27.6 L+₹3.3 L (13.5%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹28.9 L+₹4.6 L (18.8%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹29.2 L+₹4.9 L (20.0%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹48.3 L
EMD Value
₹96,560
Closing Date
31 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I KANPUR
GE I Kanpur Cariappa Road Cantt Kanpur 208004
COMPREHENSIVE MAINT PETTY REPAIR OF INTERNAL ELECTRICAL COMPLAINTS IN OTM UNIT CANTT AREA UNDER GE I KANPUR
2022_MES_500510_1
GE(I)/KAN/T-66 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Kanpur Cantt
Class D category b i
7 documents required · 7 mandatory
₹500
GE I KANPUR
₹96,560
Yes
14 Mar 2022
10 Jan 2022
7 Feb 2022
10 Jan 2022
31 Jan 2022
24 Jan 2022
60 days
Amount
Attending complaints fo checking and replaceing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. attending minor repair(s) such as testing, connectins, fittings, nut, bolts, screws etc to emergent complaints i.e no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electical system of main building/block and making continuous electric supply including carrying out minor repairs etc.. required to make the system in order/*functional with insualtion tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-in-Charge. Notes :- This item is applicable only where no store is required. 1. The site for attending complaints are 17 Kumaon,157 LT AD,90 Fd wkshp,944 Wkshp,12 Assam,09 Sikhlai,Bde HQ and offr mess. Contractor shall provide minimum one tradesmen (electrician) for each site to attend the complaint in all working days between 0830 hrs to 1700 Hrs including holiday and Sunday. 2. Contractor shall ensure the security passess for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the electicians with necessary tools bag shall always remain present at complaint cell to attend the Complaints. 4. A recovery of Rs 500/- for not attending the complaint upto 04 hours and after 04 hours Rs 1000/- shall be recovered from the contractor due 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7. The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid seperately as S&F here in after.
Supply and fix in replacement cable PVC insulated unsheathed with flexible multistranded copper conductor of size 0.75 Sqmm.
All as per item No 2 above but size 1.5 Sqmm.
All as per item No 2 above but size 2.5 Sqmm.
All as per item No 2 above but size 4 Sqmm.
All as per item No 2 above but size 6 Sqmm.
All as per item No 2 above but size 10 Sqmm.
S&F for switch piano flush button single pole one way 5 amps 240 volts
S&F Switch piano flush button single pole one way 15 amps 230 Volts
S&F for socket 5 amps 5 pin flush type, 230 volts.
S&F for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts
S&F for bell push flush button single pole one way 5 amps 240 volts.
S&F for electric bell heahy dutyding dong,buzzer type AC 230 volts single pole complete and all as specified.
S&F for switch modular type single pole one way 1 module 6 amps 240 volts.
S&F Switch modular type one way 1 module 16 amps 230 Volts.
S&F for socket 6 amps modular type 2/3 pin combined 2 module , 230 volts as per sample.
S&F for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts. as per sample..
S & F modular white cover plate with frame 2/3 module all as specified and directed. as per sample.
S & F modular white cover plate with frame 4 module all as specified and directedas per sample.
S & F modular white cover plate with frame 6 module all as specified and directed as per sample.
S & F imodular white cover plate with frame 8 module all as specified and directedas per sample.
S & F modular white cover plate with frame 12 module all as specified and directed.as per sample.
S&F for ceiling rose surface bakelite 3 terminals
S & F Lamp holder insulated body with back plate for dome batten fittings.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed by engineer-in-charge.
Supply and fixing in replacement modular regulator as per sample all as required or directed by engineer-in-charge.
Supply & fix in replacement Choke eletronic 36/40 watts 230 volts with white engineering sleeker white engineering plastic housing all as required or directed by engineer-in-charge.
S&F Tube rod 4', 1x 36/40 Watt 240 Volts all as directed by Engr-in-Charge.
Supply and fixing in replacement spring loaded rotary type bipin holder suitable for tube light fittings 4' x 28/36/40 watt all as required at site or directed
Supply and fixing in replacement plug top 3 pin 16 amps AC 240 Volts all as directed by Engr-in-Charge.
Supply and fixing in replacement plug top 3 pin 6 amps AC 240 Volts all as directed by Engr-in-Charge.
Supply & fix in replacement hylem sheet cover 3 mm thick of size 7"x4" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box.
All as per item No-32 above but of size 8"x10" .
All as per item No-32 above but of size 11"x9".
All as per item No-32 above but of size 13"x11" .
S&F in repair sunken box size 8"x10" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
S&F in repair sunken box size 7"x4" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
Supply and fix LED batten luminaire surface mounted aluminium housing, 4 feet system wattage of 20/22 Watts with lifetime of not less than 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, , surge protection 3KV in CM, IP-20n Protected, meets LED IS specifications, Class-1, Short circuit and over circuit protection, voltage range-150 to 270 Vots AC, System effiency at luminaire lelvel > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixe complete all as pecified and directed by Engr-in-charge. Note:- All the above mentioned specifications will be verifed through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures.
S & F in replacement of LED post top lantern 35/40 Watt warm white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP-65 protection fixing with proper arrangements and making electrical connection complete all as spfd.
S & F in replacement of LED post top globestarmade up of unbreakable polycarcarbonate suitable for mounting on gate with led bulb 12 W with proper arrangements and making electrical connection complete all as spfd. Make :Surya Cat Part No SLE PT 12W-GS250 or equivalent in Wipro/Bajaj/havells
Supply and fix LED batten luminaire surface mounted aluminium housing,, 2 feet system wattage of 10 Watts with lifetime of not less than 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, , surge protection 3KV in CM, IP-20n Protected, meets LED IS specifications, Class-1, Short circuit and over circuit protection, voltage range-150 to 270 Vots AC, System effiency at luminaire lelvel > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixe complete all as pecified and directed by Engr-in-charge. Note:- All the above mentioned specifications will be verifed through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures.
S&F in replacement of LED light fitting recess mounted 36 Watt, 1' x 4' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection with making electrical connection with three core copper wire to ceiling rose properly all as directed.
S&F in replacement of LED light fitting recess mounted 31/32 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making making electrical connection with making electrical connection with three core copper wire to ceiling rose properly all as directed.
Supply and fixing 10W surface mounted IP65 Bulkhead with system efficiency of 100LM/Watt LED bulk head shall be made up of Die cast Aluminium housing for better heat decapitation.P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
M&L for single pole and neutral enclosure with a top pin earth plug and socket complete with one SP MCB 25 Amps 240 volts complete all as specified and directed.
M&L for RCCB Ac type Double pole 240 volts 63 amps,ISI/CE marked as per IS/IEC 12640, Degree of protection IP 20, rated conditional short-circuit, Inc 10 KA, 35 sqmm terminal, biconnect terminals, frequecncy 50 Hz, operating Voltage 240V/415V AC with 100 mA sensitivity complete all as specified and directed.. Make: Hager/Havells/ Indo Asian/L&T
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection with acrylic cover single phase 240 volts 4 way, including suitable size copper bus bar and neutral link of make Legrand or equivalent of make Havells/L&T fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection with acrylic cover single phase 240 volts 8 way, including suitable size copper bus bar and neutral link of make Legrand or equivalent of make Havells/L&T fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 KA using thimbles of required size.
M&L MCB single pole & neutral 240 volts 32 amps,with rupturing capacity 10 KA using thimbles of required size.
M&L MCB single pole & neutral 240 volts 63 amps,with rupturing capacity 10 KA using thimbles of required size.
Supply and fix in replacement of LED Wall Security light 25 Watt IP 66 Energy saving & environmental friendly long life pressure die-cast aluminium housing for better heat decapitation efficiency not less than of 100LM/Wat ,P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as spfd.
S & F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, confirming to cat pt No 607913 of Legrand or equivalent of make Havells complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
S & F switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal with complete with plastic box all as specifid and directed
S & F switch socket combination 2 in 1, 3 pin,15 Amp flush type universal with complete complete with plastic box all as specifid and directed
S & F Switch socket combination 2in 1, 5 A flush types all as specifid and directed
S & F Switch socket combination 2in 1, 15 A flush types all as specifid and directed
S & F of led Bulb of 09 Watt cool day light eco friendly energy efficient all as specified and directed by Engr In Charge.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
S & F of LED Bollard flare fitted with low glare diffuser light 12 W with suitable pcc foundation and making all electric connection all as specified and directed.
S & F of LED polycarbonate T8 with in built driver with metal heat sink double sided connection 20 Wwith suitable and making all electric connection all as specified and directed.
Supply and laying to wall or poles or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor 10 sq. mm nominal cross section twin core for service connections all as required and directed.
All as per srl item No 62 but cable of size 6 Sqmm 2 core.
All as per srl item No 62 but cable of size 16 Sqmm 2 core.
YS CONSTRUCTION
Preetpowercontrol
M/S G S Gupta and Sons
SUSHMANAND ENGINEERING WORKS
M/s A S Electrical
PAWAN COOL CORPORATION
Kumar Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .