Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAdmitted-Finance | ₹27.9 L | L1 | Admitted-Finance |
| 2 | L2₹40.5 L+₹12.6 L (45.0%)Admitted-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹40.5 L+₹12.6 L (45.0%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | - | - | Rejected-Technical The firm is having balance value of work more than five times of its upper tendering limit as per latest WLR and firm has submitted solvency and working capital certificate more than one year old. |
| Sl No | Description | Qty | Unit | Commercial Traders L2 | YANSHIKA SECURITY SERVICES L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft/loose soil not exc 1.50 m wide and not exc. 1.5 m depth and getting out for taking out/laying cable, pole & stay etc including taking out old precast concrete cover complete all as specified and directed by Engineer-in-Charge.. | 205.74 | CUM | 85 ₹17,487.9 Lowest | 85 ₹17,487.9 Lowest |
| 2.00 | Returning, filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge. | 143.2 | CUM | 20 ₹2,864 Lowest | 25 ₹3,580 |
| 3.00 | Removal of excavated surplus soil to a distance not exc. 50 mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. | 15.91 | CUM | 25 ₹397.75 Lowest | 25 ₹397.75 Lowest |
| 4.00 | Material & Labour for sand cushioning to underground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) and after punning down sand cushioning will be 18 cm complete all as specified and directed by Engineer-in-Charge.
Note : 18 cm punned thickness only will be considered for payment purpose. | 41.14 | CUM | 250 ₹10,285 | 199 ₹8,186.86 Lowest |
| 5.00 | Material & Labour for precast concrete cable cover class HV type 1, flat size 300mmx180mmx40mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. | 1,700 | Each | 21 ₹35,700 | 4 ₹6,800 Lowest |
| 6.00 | Re-Laying only old but serviceable precast concrete cable cover class HV type, flat size 300 mm X 180 mm X 40 mm in trenches for cable protection with cable cover retrieved from srl No 1 here in before complete all as specified and directed by Engineer-in-Charge. | 700 | Each | 1 ₹700 Lowest | 1 ₹700 Lowest |
| 7.00 | Supply, laying testing and commissioning in replacement of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with stranded aluminium conductor, 11000 volts, grade of size of cable 300 sqmm 3 core suitable for earthed system including taking out unserviceable cable as in trenches /passing through pipes/ on poles, etc complete all as specified and directed by Engineer-in-Charge.
Note :- ( Excavation & Earth work, Sand cushioning and precast concrete cable cover shall be measured and paid separately under relevant items of Sch. ‘A’). | 85 | RM | 2,450 ₹2,08,250 | 800 ₹68,000 Lowest |
| 8.00 | All as per item No 7.00 here in before but size 240 sqmm 3 core complete all as specified and directed by Engineer-in-Charge. | 100 | RM | 2,200 ₹2,20,000 | 650 ₹65,000 Lowest |
| 9.00 | All as per item No 7.00 here in before but size 185 sqmm 3 core complete all as specified and directed by Engineer-in-Charge. | 100 | RM | 1,650 ₹1,65,000 | 499 ₹49,900 Lowest |
| 10.00 | All as per item No 7.00 here in before but size 120 sqmm 3 core complete all as specified and directed by Engineer-in-Charge. | 150 | RM | 1,200 ₹1,80,000 | 425 ₹63,750 Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Aug 2026, 6:00 pmClosed
CWE (AF) Palam
CWE (AF) Palam, Delhi Cantt-10
REPAIR MAINTENANCE OF DISTRIBUTION TRANSFORMERS, HT VCBS, RING MAIN UNIT, HT CABLES AND CONNECTED ITEMS AT PINTO PARK AND TECH AREA UNDER GE (AF) PALAM, DELHI CANTT-10
2026_MES_776066_1
CWE/PM/N-17/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Palam
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE (AF) Subroto Park
₹60,000
Yes
17 Sept 2026
2 Jul 2026
10 Aug 2026
2 Jul 2026
3 Aug 2026
20 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches in soft/loose soil not exc 1.50 m wide and not exc. 1.5 m depth and getting out for taking out/laying cable, pole & stay etc including taking out old precast concrete cover complete all as specified and directed by Engineer-in-Charge.. | 205.74 | CUM | - | - |
| 2 | Returning, filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge. | 143.2 | CUM | - | - |
| 3 | Removal of excavated surplus soil to a distance not exc. 50 mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. | 15.91 | CUM | - | - |
| 4 | Material & Labour for sand cushioning to underground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) and after punning down sand cushioning will be 18 cm complete all as specified and directed by Engineer-in-Charge.
Note : 18 cm thick only will be considered for payment purpose. | 41.14 | CUM | - | - |
| 5 | Material & Labour for precast concrete cover class HV type 1, flat size 300mmx180mmx40mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. | 1,700 | Each | - | - |
| 6 | Re-Laying only old but serviceable precast concrete cover class HV type, flat size 300 mm X 180 mm X 40 mm in trenches for cable protection with cable cover retrieved from srl No 1 here in before complete all as specified and directed by Engineer-in-Charge. | 700 | Each | - | - |
| 7 | Supply, laying testing and commissioning in replacement of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with stranded aluminium conductor, 11000 volts, grade of size of cable 300 sqmm 3 core suitable for earthed system including taking out unserviceable cable as in trenches /passing through pipes/ on poles, etc complete all as specified and directed by Engineer-in-Charge.
Note :- ( Excavation & Earth work, Sand cushioning and precast concrete cover shall be measured and paid separately under relevant items of Sch. ‘A’). | 85 | RM | - | - |
| 8 | All as per item No 7.00 here in before but size 240 sqmm 3 core complete all as specified and directed by Engineer-in-Charge. | 100 | RM | - | - |
| 9 | All as per item No 7.00 here in before but size 185 sqmm 3 core complete all as specified and directed by Engineer-in-Charge. | 100 | RM | - | - |
| 10 | All as per item No 7.00 here in before but size 120 sqmm 3 core complete all as specified and directed by Engineer-in-Charge. | 150 | RM | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.18 MB
Tender17.pdf
Tender Documents • 0.70 MB
Credit17.pdf
Tender Documents • 0.09 MB
BOQ_869046.xls
BOQ • 0.30 MB
corrgN17.pdf
PDF • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .