| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC 29 7 KACHERI ROAD NEAR DISTRICT HOSPITAL PRATAPGARH PRATAPGARH UTTAR PRADESH 230001 | PRATAPGARH | UTTAR PRADESH | 230001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹31.0 L+₹1.7 L (5.79%)Rejected-Finance 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹34.3 L+₹5.0 L (17.0%)Rejected-Finance HIG 37 GROUP 38 TAJNAGARI PHASE 1 AGRA 282001 CWE AGRA | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹34.5 L+₹5.2 L (17.7%)Rejected-Finance | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹35.5 L+₹6.2 L (21.2%)Rejected-Finance | L5 | Rejected-Finance Being higher bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
30 Aug 2022, 6:00 pmClosed
GE AF Tech Area Agra
GE AF Tech Area Agra
PETTY ESSENTIAL REPAIRS TO WATER SUPPLY SYSTEM AT 4 AREA MAP ANC UNDER GE AF TECH AREA AT AF STN AGRA
2022_MES_543623_1
82001442/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE AF Tech Area Agra
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE AF Tech Area Agra
₹96,000
Yes
3 Nov 2022
5 Aug 2022
1 Sept 2022
5 Aug 2022
30 Aug 2022
15 Aug 2022
5 Aug 2022 - 8 Aug 2022
Amount
Taking up/down GI/HDPE/PEALPE tubing in any length including fitting from trenches, walls, ceilings for relaying/replacement for the following sizes all as specified and directed :-
(a) 15 mm bore tubing
(b) 20 mm bore tubing
(c) 25 mm bore tubing
(d) 40 mm bore tubing
(e) 50 mm bore tubing
(f) 80mm bore tubing
(g) 100mm bore tubing
M&L for Laying only in trenches GI/HDPE/PEALPE tubing in any length with connections as retrieved from item No 1 here-in-before after cleaning, washing or removing old screw thread as required & providing new fittings, as required, complete all as specified and directed for the following sizes :-
(a) 15 mm bore tubing
(b) 20 mm bore tubing
(c) 25 mm bore tubing
(d) 40 mm bore tubing
(e) 50 mm bore tubing
(f) 80mm bore tubing
(g) 100mm bore tubing
M&L for laying or fixing only, GI/HDPE/PEALPE tubing with connections in any length as retrieved from item No 1 here-in-before, fixed to wall, ceiling or laid in floor after cleaning, washing or removing old screw thread as required & providing new fittings, wherever required, complete all as specified and directed for the following sizes :-
(a) 15 mm bore tubing
(b) 20 mm bore tubing
(c) 25 mm bore tubing
(d) 40 mm bore tubing
(e) 50 mm bore tubing
(f) 80mm bore tubing
(g) 100mm bore tubing
Supply, laying, testing GI tubing medium grade in trenches in any length including required GI fitting complete all as specified and directed for the following bore :-
(a) 15 mm bore tubing
(b) 20 mm bore tubing
(c) 25 mm bore tubing
(d) 40 mm bore tubing
(e) 50 mm bore tubing
(f) 80mm bore tubing
(g) 100mm bore tubing
Supply, fixing, testing GI tubing medium grade on walls/ceiling or laid in floor in any length including GI fitting complete all as specified and directed for the following bore :-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
M&L in for drilling & tapping cast iron mains in position for branch connection of 20mm bore GI pipe with MS clamps including necessary earth work if required etc complete all as specified and directed.
Supply & fixing in renewal gun metal globe gate valve with iron wheel head, screwed both ends ISI marked for the following sizes all as specified & directed :-
(a) 50mm bore
(b) 40 mm bore
(c) 25 mm bore
(d) 20 mm bore
(e) 15 mm bore
S&F in renewal bib tap 15mm bore standard of PTMT any colour screwed for iron pipe and fixed complete all as specified and directed
M&L in renewal for lead joints including spun yarn & taking out old lead by burning etc for the following bore of CI pipe /fittings complete all as specified and directed Note: (i) The quoted rate shall be deemed the necessary earth work (ii) Old taken out lead to be used in making of lead joint
(a) 300 mm bore
(b) 200 mm bore
(c ) 150 mm bore
(d) 100 mm bore
(e) 80 mm bore
Dismantling, opening head of sluice valve, taking out wedge nut/spindle with nut/wedge for replacement and refixing after replacement of Gun metal wedge nut and stainless steel spindle and refacing/regrinding sheet etc for the following size of sluice valve including nuts, bolts, washer, rubber packing and gland complete all as specified and directed.
(a) 300 mm bore
(b) 150 mm bore
(c) 100 mm bore
(d) 80 mm bore
Supply & fixing in renewal of cast iron body sluice valve ISI marked PN 1.6 and conforming to IS 14846 with stainless steel spindle of following sizes :-
(a) 200 mm bore
(b ) 150 mm bore
(c) 100 mm bore
(d) 80 mm bore
M&L in renewal for ‘D’ joints complete with collars, rubber ring, nuts & bolts etc for following bore complete all as specified and directed.
(a) 300 mm bore
(b) 200 mm bore
(c) 150 mm bore
(d) 100 mm bore
(e) 80mm bore
(f) 50 mm bore
Supply and fixing in replacement Wireless water level indicator Digital type with 4 digit 7-segment LED display 12 mm height water level of the tanks in % with resolution of 1.0 % resolution, it receive water level data from transmitter and display in % with reset switch to put off the buzzer sound with fuse protection system on/off switch for Receiver display unit.including water level data transmitter with maintenance free water level sensor including audio/visual alarm for full/low/overflow condition complete with maximum range of signal approx 500 m at arieal distance including necessary connection complete all as specified and as directed.
Supply, install, testing & commissioning water level data transmitter sensor to measure the data signalto multiple transmitter sensor to measure the data signal to multiple transmitter/other repeater to further complete all as specified and directed by Engr in Charge.
Supply & fixing in renewal of non return valve ISI marked including complete fixing accessory of following sizes:-
(a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
Supply,lowering and testing in renewal 32 mm dia high density polythylene column pipe in bore well ISI marked pressure rating PN-10 and with jointing material and HDPE fitting including taking down old U/S HDPE pipe.
Supply & laying in renewal PVC insulated and PVC sheathed copper conductor cable 2.5 Sqmm, 3 core flat for 1100 volts AC including connecting with submersible motor to starter panel complete all as specified and direced.
Taking out submersible pumping set of 1.5/2.0 HP and lowering after repair with replacement of bushes, sleeves, shaft, PVC impeller and rewinding of motor including testing all as specified and directed.
Supply and fixing in renewal wall mounted cubical type panel board with locking arrangement, comprising of starter, condenser, volt meter, indicator lamp, Amp meter, MCB/cut out of suitable capacity for 1.5/2 HP single phase submersible pumping set including fixing arrangement complete all as specified and directed.
Supply & fixing in renewal Cast iron pipes with flanged ends, centrifugally cast, class B, in any length laid in trenches/over head reservoir with Nut bolt and all fitting arrangments of following dia complete all as specified and directed . Note - (a) The subject work is to be carried out upto 21.00 m hight (b) The quoted rate shall be deemed include the cost of all tools and plants (c) The contractor shall provide sefty measure to avoid any incdents during progress of work.
(a) 80 mm dia
(b) 100 mm dia
(c) 150 mm dia
Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc. 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed.
Removal of excavated material to a distance not exc 50 Meter and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed.
M&L for Cutting of cast iron pipe in position for insertion of new tee, caller etc including necessary earth work if required etc complete all as specified and directed for the following bore: -
M & L in renewal for flange joints with rubber sheet 3mm thick, including nuts, bolts complete all as specified and directed etc for the following bore:-
Supply, fixing, jointing & testing in renewal cast iron fittings such as bends (any types radius and angle) tappers, collars, tee , Y junction, plugs, caps and connecting pieces or any other special required at site for the flanged/spigot and socketed pipes upto 150 mm dia complete all as specified and directed.
Supply, fixing, jointing & testing in renewal cast iron fittings such as bends (any types radius and angle) tappers, collars, tee , Y junction, plugs, caps and connecting pieces or any other special required at site for the flanged/spigot and socketed pipes upro 300 mm dia complete all as specified and directed.
Taking up cast iron water mains in any length (including all fittings), with flanged/spigot and socket ends and lead joints including burning out joints and recovering lead for the following cast iron water mains complete all as specified and directed.
(a) 100 mm dia
(b) 150 mm dia
(c) 200 mm dia
(d) 300 mm dia
Relaying of CI/DI pipe of following dia obtained from item No 28 above in any length complete all as specified and directed.
(a) 100 mm dia
(b) 150 mm dia
(c) 200 mm dia
(d) 300 mm dia
M&L for DI pipes ISI marked of make as specified with spigot and socket ends suitable for tyton joints, centrifugally cast, class K-9, in any length coforming to IS: 8329(2000) as per latest amendments, laid in trenches with & including making rubber gasket joints (Tyton joint) and testing on completion complete all as specified and directed for the following sizes:-
(a) 100mm bore
(b) 150mm bore
(c) 200mm bore
(d) 300 mm bore
Taking out U/S submersible pump set including motor from bore well of capacity 1.5HP after disconnecting all electrical connections & supply, fixing, lowering, commissioning & testing submersible pump set of discharge capacity 70 LPM at 57 metre head single phase , 230 volt AC electric driven 2900 RPM of 1.5 HP including necessary wiring from motor to panel etc complete all specified and directed.
S&F in repairs cast iron foot valve, flanged type with flanged, ISI marked, including making flanged joints with & including 3mm thick rubber sheet, nuts & bolts etc of suitable size for following bore complete all as specified and directed.
(a) 80mm bore
(b) 100mm bore
M & L for construction of brick masonry valve pit with sub-class 'B' brick built in cement mortar (1:6), of size (90 x 90 x 90) cm (internal dimension) with one brick thick walling and150 cm x150 cm x 10 cm base foundation with PCC (1:3:6), type C2, cement plastering 10 mm thick with cement mortar (1:4) on internal & exposed surfaces, of brick work with and including MS cover of size 01mtr x 01mtr made out from 3 mm thick MS sheet iwith (40 x 40 x 5) mm angle iron framing & painting the steel surfaces with two coats of synthetic enamel paint (first quality) over a coat of red oxide primer, including necessary excavation and earth work and . demolition of the existing old valve and removal of old dimolished materials and surplus excavated soil to a distance n-exc 50m etc complete all as specified and as directed.
M&L for earthing complete with galvansided steel earth plate electrode 600 x 600 x 6.0mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the ground level, connected to GI strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be finished with 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS bolts & washers as required and connection from earth test point to earth electrode with same GI strip alongwith protection pipe (upto distance of 7.5 mtr) complete all as specified and directed.
M&L for cutting of existing HDPE/ GI pipe of 40/50mm bore for cleaning/ leakage repairing and re-jointing the same in existing position with & including jointing rings and heating process including all necessary excavation & earth work if required and making good the surfaces as per existing complete all as specified and directed.
M&L for cutting of existing HDPE/ GI pipe of 25mm bore for cleaning/ leakage repairing and re-jointing the same in existing position after cleaning /leakage repair with & including jointing rings and heating process including all necessary excavation & earth work if required and making good the surfaces as per existing complete all as specified and directed.
M&L for cutting of existing polyethylene aluminium polyethylene (PE-AL-PE) pressure/ GI pipe of 15/20 mm dia for cleaning/ leakage repairing and re-jointing the same in existing position after cleaning /leakage repair with & including jointing rings and heating process including all necessary excavation & earth work if required and making good the surfaces as per existing complete all as specified and directed.
S&F in repairs HDPE fittings i.e reducer/ tee/ ring suitable for HDPE/ polyethylene aluminium polyethylene (PE-AL-PE) pressure pipe for stoppage of leakage at different locations/ areas including all necessary excavation & earth work if required and making good the surfaces as per existing complete all as specified and directed for the following sizes:-
(a) HDPE Tee 50x 50 X 16-20 mm bore
(b) HDPE tee of 16-20x16-20x12-16mm dia
(c ) HDPE tee of 20-25x20-25x16-20mm dia
(d) Jointing/ copper rings of 20/25mm dia
S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 sq. mm 2 core fixed on wall/ ground etc complete all as specified and directed.
Carryout day to day rectification of water supply complaint such as repair, reconnection and replacement of water supply system in air force station Agra area all as directed by Engr in Charge. Note:- Note: (a) 01 x Pipe fitter and 02 x helper will be detailed by the contractor for attending above complaints on daily basis. Cost of which shall be deemed to be included in quoted rates. (b) Replacement of major items shall be measured and paid under relevant items of this schedule. (c) Pipe fitter and helper so detailed by the contractor will report to MES complaint cell at 0845 hrs morning to receive complaint slip from department and complaints shall be rectified within 08 Hours. If contractor fails to detail above tradesmen a panel recovery@ Rs. 500.00 per day shall be made to contractor and shall be recovered from RAR/Final bill. (d) Repairing upto 06 Complaints at different water supply system with minor fittings/ fixtures materials costing upto Rs 500/- will be considered as one job.
FUTURE Inc.
J P CONTRACTORS AND SUPPLIERS
Balaji Associate
M/s S.M. Construction
RAJEEV CONSTRUCTION
jmd engineers
MUKTA AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .