| Sl No | Description | Qty | Unit | SRI BALAJI ENTERPRISES L1 | SSK ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00SITC of 11 KV indoor Resin Cast dual ratio current transformer of the following specification in existing RMG panel as per the requirement of TANGEDCO i/c obtaining test certificate from MRT, removal of existing old CT's and arranging shut down by co ordinating with the TNEB i/c alteration of bus bars etc as required for Reduction of CMD from 870 KVA to 630 KVA etc. as reqd. (Both metering & protection core shall be in single unit) | |||||
| 1.10CT for Metering Core :CT Ratio: 40/5 A, class 0.2s, Burden 5VA | |||||
| 1.20CT for Protection Core : Protection Core :- ratio 40/5A, 5P20, Burden 15VA | |||||
| 1.30 | All the above | 3 | Each | 1,48,500 ₹1.8 L | 1,62,000 ₹1.9 L |
| 2.00SITC of 11 KV , indoor 3 phase Resin Cast Potential transformer of the following specification in existing RMG panel along 11 KV HT fuse -3 nos suitable for existing RMG panel as per the requirement of TANDEDCO i/c obtaining test certificates from MRT, removal of old PT's and interconnections and modification of bus bars if required etc as reqd. | |||||
| 2.10 | PT Ratio :11KV/√3/110V/√3, Class:0.2, Burden :15VA | 1 | Each | 63,000 ₹74,340 | 65,000 ₹76,700 |
| 3.00Note: 1. CT & PT shall be of above specifications, suitable to existing HT panel and shall be of TANGEDCO approved make 2. Co-ordination for shut down & other activities such as testing of CT/PT and submission of reports. Liaisoning etc are to be carried out by the firm without any extra cost | |||||
Tender Value
₹2.5 L
EMD Value
₹5,027
Closing Date
22 Dec 2025, 3:00 pmClosed
EET
EET, BSNL ECII Kellys Chennai
Operation and Comprehensive maintenance of transformer Substation and EA sets in Haddows Road Chennai TE SW Replacement of CT and PT for MD reduction
2025_BSNL_259095_1
NIT No 72/EE-T/EC-II/CH/2025-26
Open Tender
Electrical Works
30 days
Haddows road Chennai
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL Chennai Telephones
₹5,027
24 Dec 2025
15 Dec 2025
23 Dec 2025
15 Dec 2025
22 Dec 2025
15 Dec 2025
15 Dec 2025 - 22 Dec 2025
SITC of 11 KV indoor Resin Cast dual ratio current transformer of the following specification in existing RMG panel as per the requirement of TANGEDCO i/c obtaining test certificate from MRT, removal of existing old CT's and arranging shut down by co ordinating with the TNEB i/c alteration of bus bars etc as required for Reduction of CMD from 870 KVA to 630 KVA etc. as reqd. (Both metering & protection core shall be in single unit)
CT for Metering Core :CT Ratio: 40/5 A, class 0.2s, Burden 5VA
CT for Protection Core : Protection Core :- ratio 40/5A, 5P20, Burden 15VA
All the above
SITC of 11 KV , indoor 3 phase Resin Cast Potential transformer of the following specification in existing RMG panel along 11 KV HT fuse -3 nos suitable for existing RMG panel as per the requirement of TANDEDCO i/c obtaining test certificates from MRT, removal of old PT's and interconnections and modification of bus bars if required etc as reqd.
PT Ratio :11KV/√3/110V/√3, Class:0.2, Burden :15VA
Note: 1. CT & PT shall be of above specifications, suitable to existing HT panel and shall be of TANGEDCO approved make 2. Co-ordination for shut down & other activities such as testing of CT/PT and submission of reports. Liaisoning etc are to be carried out by the firm without any extra cost
SSK ELECTRICALS (BID ID -946354)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.20 MB
BOQ_299340.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid