Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹33.3 L+₹2.4 L (7.93%)Rejected-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹33.9 L+₹3.0 L (9.79%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹34.9 L+₹4.1 L (13.1%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹35.9 L+₹5.0 L (16.3%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹34 L
EMD Value
₹74,000
Closing Date
24 Jun 2020, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI-400088
SPL REP TO CABLE CHANNEL TRAY AT TS MAHUL REPLACEMENT OF BTY FOR 60 KVA UPS AT TS MAHUL PROVN OF HIGH MAST LIGHT AT THANE AND PROVN OF ADDN POWER SUP AND ALLIED WORKS AT NCN AND COMCEN AT INS TANAJI MANKHURD UNDER GE (NW) MANKHURD
2020_MES_334482_1
8972/E8
Open Tender
Civil Works
Item Rate
180 days
GE(NW) MANKHURD
AS PER NIT AND TENDER PAGES
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹74,000
Yes
4 Jul 2020
16 Mar 2020
26 Jun 2020
16 Mar 2020
24 Jun 2020
15 Apr 2020
16 Mar 2020 - 30 Mar 2020
Amount
Notes : (i)The contractor should be in possession of valid electrical license to execute electrical works. (ii) Supervisor for execution of electrical works/ electrical component of works employed by the contractor shall possesses supervisor certificate of competency issued by concerned State Government/ Union Territory and the worker/ tradesmen for execution of electrical works/ electrical component of works shall hold necessary permit issued by concerned State Government/ Union Territory. Demolition of cement concrete (reinforce) of any description and in any position not otherwise specifically provided for and removing the debris out side Md land complete all as specified and directed.
M&L reinforced cement concrete type B-1, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area in exc 250 Sq cm and n exc 400 sqcm, with or without chamfered angles and flat, splayed, rounded or mitred tops and fixed complete all as specified and directed
M&L precast cement concrete type B-1 (1:2:4) (using 20mm graded aggregate) set in CM (1:4) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain with plain fair faces, including chamfers weatherings throating etc. and setting in mortar with joints to match complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in hard/dense soils, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
M&L for TMT bar 10 mm dia and over, cut to length,bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality etc complete all as specified and directed.
Ditto but 5 mm over upto and including 10 mm dia in stirrups, spacers and binders etc complete all as specified and directed.
S&F FI 50x4mm bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintel hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps,plate washers and similar small articles conforming to Fe 290-0 Gde E -165 etc complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut ,n exc 5cm long, 5 to 10mm dia of neck complete all as specified and directed.
M&L preparation of new steel surface of any description n.exc 10cm in width or girth and applying 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed.
M&L preparation of new plastered/RCC surfaces and applying three coats of white wash etc complete all as specified and directed.
M&L plain cement concrete in foundations filling and mass concrete Type C-2 1:3:6 (40mm graded aggregates) complete all as specified and directed.
Supply and fix in replacement battery heavy duty 12 Volts 120 AH maintenance free Suitable for online UPS 60KVA capacity complete all as specified and directed. Make : Exide / Amron / Cummins
Supply and fix battery terminal, and cable(copper conductor) of Size not less than 50sqmm single wire heavy duty, suitable for 120AH 12 V battery, as fixed in repairs complete all as specified and directed.
Sppply, errection and commissioning of high tensile steel (confirming to BS-EN10 025 Grade S 355) asymmetrical High Mast lighting system of 16 meter Height in two section of bottom dia 410 mm x 4mm thick and top dia 150 mm x 3mm thick provisioned with suitable size of door opening. The High Mast Pole shall Confirm to Cat No BHMRL16D of Bajaj / Crompton /Phillips, including the following : - (a) Provision of pully system at top to accomodate ropes & electric cables, Provision of 06 Nos luminaries carriage made of ERW steel pipes designed to act as cable conduit with cable entry holes, luminaries fixing arms, junction box mounting bracket, carriage buffer arrangements. (b) Motorised & manual operating double drum winch raising & lowering system with, 1 No 1 HP motor, two continous 6 mm dia stain less steel wire rope, 5 core 2.5 Sqmm EPR insulated, PVC sheathed trailing power cables, junction box, multi core cables from junction box to individual luminairie all as per recommandation of OEM (c) 25 mm thick base plate with 8 Nos of 30 mm dia & 850 mm long anchor bolts with nuts (d) 6 Nos - LED Flood light 350 Watts, with pressure die cast housing IP 65 protection, the fitting shall conform to cat no BJFL 350 W LED of Bajaj or equivalent in Philips/ Crompton (e) 01 Nos Integral aviation LED light 30 Watt of make Bajaj / Phillips / Crompton comprising of aluminium housing with polycarbonate enclosure. (f) Counter weight as recommended by OEM for asymmetrical arrangement of lights. (g) Pole foundation drawing shall be as per OEM for High mast to suit Wind speed as per IS 875 Part III: 1987 including form work, excavation in any strata, refilling, removal, PCC foundation and RCC footing and column as per the following specification:- (i) PCC base with PCC 1:4:8 , type D2 using 40 mm graded aggregate (ii) RCC M 20 footing using 10mm TMT bar @ 200 mm c/c both way (iii) RCC M 20 column using 24 Nos - 12 mm TMT bar (vert) and 10 mm dia stirrups @ 150 mm c/c (h) 01 No- LT Feeder panel, cubical out door type, factory fabricated from 3 mm thick CRCA sheet outdoor type of suitable size to accomadate all accessories / fittings, incommers, outgoings, bus-bars, other components/ parts etc. The cubicle shall be of free standing type with frame made of angle iron . A detachable predrilled mild steel gland plate of thickness not less than 3 mm thick powder coated shall be used at the bottom for entry of armoured cable of adequate size with glands. The panel shall comprise of the following i) MCB 32 Amps - 1 Nos ii) Single Dial Time Switch - 1 No iii) Three Pole MCB Contactor - 1 Set iv) Power Tool Control including 2 No 09 Amps Contactor v) Lower & Raise Push Buttons vi) Connectors for Incoming & Outgoing Cables vii) Internal wiring & any acessoroies recommended by OEM for the smooth operation of the High Mast Lighting System Note - 1. The contractor shall submit drawings & specification of OEM and shall be got approved before procurement. 2. Tha High Mast and LED light fittings shall be used of same make only.
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 mtr depth for laying of underground cable, erection of poles etc n.exc 10 sqm on plan. and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class LV ISI Marked, type-I, flat size 250mm x 150mm x 40mm complete all as specified and directed.
M & L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply & Lay XLPE insulated, armoured heavy duty 1100 volt grade electric LT UG cable with multistranded aluminium conductor of size 16 Sqmm 4 Core laid in trenches/along the wall/pole including making all connections complete all as specified and directed.
M&L for cutting existing road/hard standing not exc 30 cm x 50 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed
S& F GI steel tubing medium grade 40mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm as earthing lead by means of nuts bolt check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering, filling with charcoal dust and comman salt in alternate layers, funnel with wiremesh necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 3 of MES SSR Pt-I and testing on completion.
Supply & Fix MCCB DB TPN 4 Way double door prewired suitable for Triple Pole 63 A incomer MCCB with the following acessories, a) MCCB TP 63 A 25 KA 415 Volt - 1 Nos b) Bus bar, Din rail , Neutral link
M&L for MCB TPN, 240 volt, 63 Amps, 10 KA, C Curve,
M&L for MCB SPN, 240 volt, 63 Amps, 10 KA, C Curve,
M&L for MCB SP, 240 volt, 40 to 63 Amps, 10 KA, C Curve,
S&F single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified and directed.
M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade ISI marked drawn in through PVC casing caping with and including PVC insulated 4 Sqmm single core single stranded copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid as one unit.
Supply and Laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 120 Sqmm 3.5 core in trenches, along the wall including necessary connection and providing cable lugs, Saddles, cable gland etc as required complete all as specified and directed.
Supply and fix MCCB FP 100 Amps 415 Volt 35 KA with and including CRCA powder coated enclosure with front openable door, wall mounted type with provision for cable entry suitable for upto 120 sqmm x 3.5 Core cable including necessary grouting in wall with nuts, bolts/ fastener, washer etc all as specified and directed
M & L for point wiring with PVC insulated unsheathed 1100 Volts grade single core FRLS multistranded copper conductor cable 2.5 Sqmm ISI marked drawn in and including casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories and earth continuity conductor cable of 2.5 Sqmm size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified for 3 pin 15A socket multipurpose on independent board complete all as specified and directed.
Supply & Fix switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and directed.
Supply, fixing, testing and commissioning Hi wall, 2 Ton Split type Air Conditioner, 5 Star Rated electric driven fitted with hermetically sealed compressor, condenser with alloy coil, wall mounting bracket, remote controller, suitable for operation on 230 Volts 50 HZ, single phase AC supply, including provison of copper tubes of suitable size as required at site all as specified and directed. Make :- Hitachi RAU518EUDA / Voltas/Blue Star / Carrier / Daikin
M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
Dismantling of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head conductor and removing unserviceable pole from site complete all as specified and directed.
Supply and erection of steel tubular swaged pole 9.00 metres long designation 410-SP-31 complete with cast iron base plate, finial taper plug, bolts, nuts and screws etc including and numbering of poles with white paint on black paint base and stripping with black paint (100 mm each stripe) 3 Nos at equal distance from bottom (above PCC coping) upto a height of 1200 mm complete all as specified and directed. [Note :- Earth work and concrete foundation shall be measured and paid seperately under relevant items of BOQ).
S&F in repair street light bracket made out of 50mm dia GI light grade tubing not less than 1.2 mtr long bend to shape including pole clamps made out of 50 x 6 FI and nut, bolts and washers complete all as specified and directed.
Supply, laying or fixing in repair 40mm bore galvanised iron tubing, light grade with all fittings for passing of cables laying in trenches, pole coping etc. including all fixing accessories complete all as specified and as directed.
Supply & fix in repair 3 core 1.5 Sqmm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt cable for interconnection of cable looping box to Street Light Fitting complete all as specified and directed.
Supply and fix in repair of FRP looping box of size 300x250x120 mm with connector, MCB 6 Amps, Din Rail, including GI clamps made out of GI flat of size 25mm X 3 mm channel and necessary nut, bolts and washer including making connections complete all as specified and directed. Make - National / Hensel /Universal
Earthing complete with galvanised steel earth plate electrode size 60cm x 60cmx 6mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earth lead 4mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth wire protected by galvanised iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC 1:3:6 type C-1(using 20 mm graded stone aggregate), pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 3 of MES Schedule Part- I and testing on completion complete all as specified and directed.
Supply and fix in repair street light fittings in street light poles the fitting shall be of Edge LED type 60 Watts (Warm White) complete with and including drivers, pressure die cast aluminium housing, prewired complete as per cat part No BRTFG 60W LED V3 WW of Bajaj or equivalent in Havells / Crompton complete all as specified and directed. Note : A sum of Rs 37,670.00 towards sch of credit shall be deducted to arrive the contract sum.
joshua construction
Shree Ayyappa Engineering
cooltech engineering services
DHARMESH ENTERPRISES
Atharva Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .