| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹96.7 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹99.8 L+₹2.8 L (2.93%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹1.0 Cr+₹3.9 L (4.03%)Rejected-Finance | L-3 | Rejected-Finance Being L-3 | |
| 4 | Rejected-Technical BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | - | Rejected-Technical Due to not enlisted in c(vii) category as per NIT and EPF not uploaded | |
| 5 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | Rejected-Technical Due to not enlisted in c(vii) category and scanned copy of DD not uploaded as per NIT |
Tender Value
₹98.5 L
EMD Value
₹1.7 L
Closing Date
18 Nov 2024, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
OUTSOURCING OF SERVICES FOR MANNING AND OPER FOR MAINT OF WATER SUPPLY INSTAL AT TANAJI, SPDC AREA AND SWIMMING POOL AND MAINT OF SWIMMING POOL PUMPS AND MOTORS AND COMPRE REPAIRS TO ELECT MOTOR, PUMPS, AND ALLIED WORKS AS SPECIFIED IN SCOPE OF WORK
2024_MES_680472_1
8884/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹1.7 L
Yes
10 Jan 2025
21 Oct 2024
21 Nov 2024
21 Oct 2024
18 Nov 2024
11 Nov 2024
Amount
Mannual rescue and operation rescue of water supply installation with all connected equipments, supply lines, machineries and electric driven pump set and Chlorine dosing plants of various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced operator/FGM/technician (01 No/Shift) for 02 shifts, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : Tanaji pump house, The details of operation of water supply installations comprising the following items/machinery/fittings:- (i) Operating Mono block centrifugal Pumping set of capacity 7.5 HP - 02 Sets (ii) Operating Chemical dozing system - 01 set
Mannual rescue and operation rescue of water supply installation with all connected equipments, supply lines,Machineries and electric driven pump set of various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced operator/FGM/technician (01 No/Shift) for 03 shifts, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : NAD Firefighting Pump House The details of operation of water supply installations comprising the following items/machinery/fittings:- (i) Operating main electric fire Pumping set of capacity 75 HP - 02 Sets (ii) Operating Jockey fire Pumping set of capacity 15 HP - 01 Sets
Mannual rescue and operation rescue of water distribution sluice valves and firefighting sluice valves of various sizes installed at GE(NW) Mankhurd area for employing valve men on all days including Sunday & Holidays as directed by Engineer-in-Charge for the following locations and shifts:- a) NAD(T) area for fire fighting and water distribution valves - 01 Shift Notes for item No.01 to 03:- (a) Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractor from his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account. (b) Installation shall be manned including Saturdays, Sunday & Holiday. (c) Proper log sheets for running of the pump to be maintained. (d) Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge. (e) Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f) Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing. (g) The contractor shall be responsible to keep the water supply installation neat and clean on every day. (h) All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue. (j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :- (i) Operator - @ Rs 2000 per operation shift per head. (ii) Valve man - @ Rs 1800/- per operation shift per head.
Manual rescue and operation rescue of Electric supply installations round the clock in three shifts including Sunday & holiday by employing one skilled Electrician (having knowledge of HT VCB, HT OCB, Transformers, APFC & LT Panels) in each shift at Main Receiving Station at NAD including operating HT & LT panels, carrying out break down maintenance in transformer, HT,LT Panels cables etc, daily cleaning and upkeep of surrounding area of installation and Maintaning record of daily Break Down & maintenace, Monitoring & Recording of parameters such as Voltage, Current, PF etc Power factor at NAD Depot (Trombay) and Naval Dett (Kalyan/ Ambernath) all as specified and as directed by Engineer-in-Charge. Notes :- (a) All the T&P required for the Manual rescue & Operation rescue of installations shall be provided by the contractor and cost of the same is inclusive of quoted rate (b) Materials required for upkeep of installations such as rooms, dusty cloth for cleaning of plants, buckets, etc shall be always available at the installations for use and shall be deemed to be included in the quoted rates. (c) The Contractor should prepare duty chart on monthly basis and shall be got approved by Engineer-in-Charge. (d) Attendance register shall be submitted to Engineer-in-Charge on Daily basis. (e) Skilled electrician shall have ITI certificate and 5 Year experiance certifcate in HT maintenace. (f) The Contractor shall submit bio-data of the technician and experience on handling HT equipments. The individual will not be permitted to perform duty, if found unfit. (g) In case any operator is missing or absent from duty, a penalty of Rs 2000/- per technician shall be recovered from contrcator and Engineer-in-Charge decision shall be final and binding on this account. (h) Each shift duration shall be 08 Hrs timing as required at the discreation of Engineer-in-Charge, details of shift are as under :- Shifts : 1st shift : 0600 to 1400 hrs, 2nd shift : 1400 to 2000 hrs, 3rd shift : 2000 to 0600 hrs (i) Electrician-@ Rs 2000/- per operation shift per head (ii) Helper - @ Rs 1800/- per operation shift per head. (i) Contribution towards bonus EPF, ESIC the amount is payble only after submission of valid and authentic document in support of having paid the requisite amount to the employed labour.
Mannual rescue and operation rescue of water supply installation with all connected equipments, supply lines, machineries and electric driven pump set and Chlorine dosing plants of various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced operator/technician (01 No/Shift) for 02 shifts, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : SPDC pump house, The details of operation of water supply installations comprising the following items/machinery/fittings:- (i) Operating Mono block centrifugal Pumping set of capacity 40 HP - 02 Sets (ii) Operating Mono block centrifugal Pumping set of capacity 25 HP - 03 Sets (iii) Operating Mono block Pumping set of capacity 5 HP - 02 Sets (iv) Operating DG set 75 KVA - 01 No (v) Operating Chemical dozing system - 01 set
Mannual rescue and operation rescue of Swimming Pool, consisting of following equipments & Electrical Panel boards etc. by employing one FGM (Skilled) Per Shift of 8 hrs for 2 Shifts, 16 Hrs per day, including Sundays & Holidays, Comprising the following works :- (a) Operating Pump sets of any capacity as directed (b) Checking water level in the Swimming Pool. (c) Operating Chlorination/Ionization Plants as directed (d) Maintaining Log Book for Swimming Pool (e) Maintaining record of timing of Swimming Pool operation (f) Operating Sluice/Gate Valves for Supply of water to pool as per the time schedule/requirement. (g) Routine maintenance & cleaning/back washing of filteration plant. (Note : Disinfectant chemicals and other consumable chemicals required for Operation and maintenace of Swimming Pool will be measured and paid separately under relevent item of the schedule) A. EQUIPMENTS : (a) (i) Starter Panel - 01 No (b) Vertical type pressure filter capacity 30000 gallons/ hour - 02 Nos (c) Pump set capacity 20 HP - 03 Nos (d) Suction sweeper complete with Accessories and suction hose along with 2 HP pump set - 01 No. (e) Connecting Valves of various type/sizes.
Mannual rescue and operation rescue of water distribution sluice valves of various sizes installed at GE(NW) Mankhurd area for employing valve men on all days including Sunday & Holidays as directed by Engineer-in-Charge for the following locations and shifts:- a) SPDC area for water distribution. - 01Shift Notes for item No.05 to 07:- (a) Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractor from his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account. (b) Installation shall be manned including Saturdays, Sunday & Holiday. (c) Proper log sheets for running of the pump house & plants to be maintained. (d) Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge. (e) Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f) Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing. (g) The contractor shall be responsible to keep the water supply installation neat and clean on every day. (h) All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue. (j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :- (i) Operator - @ Rs 2000 per operation shift per head. (ii) Valve man - @ Rs 1800/- per operation shift per head.
M&L for repair of angle iron, U shape channel of any size as per site requirement, welding to required shape, including all nuts,bolts,washers etc complete all as specified and directed by engineer-in-charge.
Supply only bleaching powder for treatment of water and other purposes etc complete all as specified and directed.
Supply& fixing in repairs of Chequered plate Fe 410-W(Gde-E- 250)A quality- for cable trenches, ladders including equal angle trench frames, including cutting as per requirement of site, square cut or notched (ordinary and counter sunk) forming holes, without any including providing handles
Supply& fixing in repairs for mild steel work confirming to Fe-290, GdeE-165 in stairs/ladders including stringes, treades, landing, balusters, hand rails etc including applying two coat of paint over one coat of red oxide complete all as specified and directed.
Fabricate supply and fix valve chamber covers made out of suitable size MS angle/MS plate/flat/rod,hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removing existing unserviceable rusted cover all as directed.
M&L for rewinding of electric motor 40 HP 3 phase 50 Hz 415 volt of following capacities complete all as directed and specified as under: (a) Disconnecitng, dismantling existing burnt widning from motor and rewinding complete with super enamled copper winding wire of matching gauge including all insulation material such as PVC insulated sheet, cotton tape sleeves varnish etc. (b) Transporting electric motor including loading/ unloading upto wksp and back to site. (c) Re-installing the same at the orignal locaition with proper alignmenent connecting and testing on load. (d) Replacement 2 Nos ball bearing for each motor of existing size/model. Make- SKF/NBC/TATA. (e) Replacement of winding terminal plate with brass stus,/ nut, bolt washer.
M&L for rewinding of electric motor 25 HP 3 phase 50 Hz 415 volt of following capacities complete all as directed and specified as under: (a) Disconnecitng, dismantling existing burnt widning from motor and rewinding complete with super enamled copper winding wire of matching gauge including all insulation material such as PVC insulated sheet, cotton tape sleeves varnish etc. (b) Transporting electric motor including loading/ unloading upto wksp and back to site. (c) Re-installing the same at the orignal locaition with proper alignmenent connecting and testing on load. (d) Replacement 2 Nos ball bearing for each motor of existing size/model. Make- SKF/NBC/TATA. (e) Replacement of winding terminal plate with brass stus,/ nut, bolt washer. NOTE: Quoted rates shall be deemed to include one year warranty for motors after rewinding and commissioning.
All as per Item No. 14 above but for Motor 20 HP Cap
All as per Item No. 14 above but for Motor 15 HP Cap
All as per Item No. 14 above but for Motor 10 HP Cap
All as per Item No. 14 above but for Motor 7.5/5 HP cap
S & F of Amp meter digital type 0 - 200 amps capacity with suitable type ratio CT size as per existing including taking down the exsting and remove complete all as specified and as directed. Make :- C&S / schneider / AEI / L&T
S & F volt meter digital type 0 - 500 volt including taking down the existing and remove complete all as specified and as directed. Make :- C&S / schneider / AEI / L&T
M & L for preparation of old painted /unpainted surfaces of any description, including taking out of parts / components under painting from any position / location as listed under GE (NW) Mankhurd and applying one coat of epoxy paint (with colour code maintained as per relevant IS) including marking with flow directions (of approved colour) complete all as specified and as directed by Engineer-In-Charge for the following sizes of sluice valves. Make : Asian / Berger / Apex / Nerolac
(a) Sluice valve of 80 mm size complete
(b) Sluice valve of 100 mm size complete
(c) Sluice valve of 150 mm size complete
(d) Sluice valve of 200 mm size complete
M & L for preparation of old painted / unpainted surfaces of any description, including taking out of parts / components under painting from any position / location as listed under GE (NW) Mankhurd and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-In-Charge for the following capacity of electric motor. Make : Asian / Berger / Apex / Nerolac
(a) Electric motor pump set upto 40 HP capacity
(b) Electric motor pump set upto 15 HP capacity
(c) Electric motor pump set upto 10 HP capacity
(d) Electric motor pump set upto 7.5 HP capacity
Material and labour for preparing old painted steel pipe surface such as Rising pipe (Red), Delivery pipe (Blue), Overflow pipe washout pipe (Yellow) etc and applying one coat of synthetic enamel paint for 100 mm bore GI pipe complete all as specified and as directed. Make : Asian / Berger / Apex / Nerolac
All as per item No. 24.00 above but 80 mm bore GI pipe.
M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification.
S&F GI strip size 32 x 6 mm all as directed including welding brazing and taking down of old copper strips as required at site
Fabricate supply and fix valve chamber covers made out of suitable size MS angle/MS plate/flat/rod,hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removing existing unserviceable rusted cover all as directed.
Supply and fix in replacement ladder height 10 feet max, steps on every 01 feet made of angle iron of size 50x65x5 mm thick for sump including taking down old rusted iron ladder complete all as specified and directed.
Supply and Fixing industrial type pressure gauge made out of SS 304 material, SS sipon shall be factory insulated with closed cell elastomeric insulation in tubing form, pressure gauses shall be factory fitted with a ball valve complete, all as specified and directed. Make : FIEBIG / H GURU / BAKER MERCER / DANFOSS
Supply only Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containers complete all as specified and as directed. Make:- 1.Aqufit manufactured by Sree Rayalaseema Hi strength Hypo Ltd. 2. Puri chlor manufactured by Sree Rayalaseema Hi strength Hypo Ltd. / M/s Ravi Enterprises / M/s Potter & Watts (Traditional products). Brands having pan india availability, acceptability & being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. 3. Best available in the market
Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating, Conforming to Type MNX 25 & Cat No - CS94110 of L & T or Equivalentt from Schnider Electric, ABB including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system
All as per item No. 32 above but Contactor Three Pole 415 volts 32 Amps AC 3 Rating Conforming to Type - MNX 32 & Cat no - CS94111 of L & T or equivalent from Schnider Electric, ABB/ C&S
All as per item No. 32 above but Contactor Three Pole 415 volts 40 Amps AC 3 RatingConforming to Type - MNX - 40 & Cat no - CS94190 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No. 32 above but Contactor Three Pole 415 volts 50 Amps AC 3 Rating Conforming to Type -MNX - 50 & Cat no CS-97075 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No. 32 above but Contactor Three Pole 415 volts 70 Amps AC 3 Rating Conforming to Type - MNX - 70 & Cat no - CS-97076 of L & T or equivalent from Schnider Electric/ABB/ C&S
Supply only DECPAC-P (Aluminium based caogulant) packing in 25 kg plastic bags complete.
M & L for repair/servicing /overhauling of split cage Centrifugal pump set by opening end covers, greasing the bearings, for replacing worn out bearing both DE and NDE side of existing size,nut, bolts, gasket, air release valve key, gland stuffing box male/ female set, Rubber bush for the Pump set 40 HP. Note-: Spare part such as bearing, shaft, impeller, bush if required shall be paid under seperate item as supply only.
All as per item No. 38 above but Pump set 25 HP
All as per item No. 38 above but Pump set 10 to 20 HP
All as per item No. 38 above but Pump set 05 to 7.5HP
Material and labour for taking out unserviceable burnt out electric monoblock/centrifugal motor with pump from the foundation of pump capacity 25 HP, 440 Volts, 50 Hz by opening/diconnecting all mechanical and electrical connection and transporting to nearest work shop and rewinding the same by using approved make super enamelled insulation copper wire of suitable insulation class of approriate size after pulling out burnt out copper wires from the sloths of stator including replacement of minor accessories like mica paper, sleeves, glass fibre, bamboo pieces etc inlcuding varnishing/heating at heat chamber suitably and opening the monoblock pump assy for replacement of unserviceable parts maintaince and reassembling all as per existing complete and taking back the whole pump sets to its original location and fixed or placed suitabley including making the electrical and pipe connection including testing to get satisfactory result complete all as specified and as directed. Note: (i) Parts if required for pump shall be measured and paid separately here-in-after under another item as 'supply only.
All as per item No. 42.00 above but For motor 10 HP Capacity
All as per item No. 42.00 above but For motor 40 HP Capacity
All as per item No. 42.00 above but For motor 5 to 7.5 HP Capacity
Supply only Ball bearing 6307 Make-SKF or eqivalant as approved by GE
Supply only Ball bearing 6308 Make-SKF or eqivalant as approved by GE
Supply only Ball bearing 6310 Make-SKF or eqivalant as approved by GE
Supply only gun metal impeller suitable for existing 40 HP pump complete all as specified and as directed.
All as per item No 57.00 above but for pump 25 HP Capacity.
All as per item No 57.00 above but for pump 10 HP Capacity.
Supply only motor bush as of existing size complete all as specified and as directed.
Supply only pump shaft made out of high strength steel material suitable for 40 HP centrifugal pump set complete all as specified and as directed.
All as per item No. 53.00 above but For motor 10 HP Capacity
All as per item No. 53.00 above but For motor 25 HP Capacity
M&L for repair/serviceing /overhauling of following Submersible pump of capacity upto 05 HP set by replacing bushes , impeller thrust bearings, strainer of existing size, nuts and bolts, washers, pump shaft remetalling, grinding, polishing,greasing complete reassembling the pump and testing, complete all as directed.
All as per item No 56.00 above but Submersible pump of capacity upto 7.5/10 HP.
Rewinding of submersible pump set motor by dismantling the pump from the motor taking it to workshop, rewinding the motor with same size of copper enameled winding wire, insulating, varnishing of the same replacement of of bushes and any other spare parts required for smooth functioning of the submersible pump, re-assembling, re-installing at site connecting complete of the Submersible pump of capacity upto 05/7.5 HP
All as per item No. 58.00 above but Submersible pump of capacity upto 10 HP Notes for item No.56 to 59: Cost inclusive for taking up defective submersible pumpset from shallow well/borewells and refixing/lowering of pumpset with suitabile equipments after repair work.
Supply & Fix in repair fully automatic star delta starter suitable for 25 HP, 440 volt, 3 Ph Elect Motor with Single Phase Protection feature conforming to IS -13947 after taking down old unserviceable one anf fixed to the same location by making electrical connection properly complete all as specified and as directed. Cat No: SS91855 of Make-L&T or equivalent to C & S / Schneider
All as per item No. 60 above but for eletrical motor 10 HP, Model MK1 FASD of L& T Make, CAT Pat: SS96254 or equivalent to C & S / Schneider
All as per item No. 60 above but for eletrical motor 40 HP, Model MK1 FASD of L& T Make, CAT Pat: SS94366.
S&F in repairs DOL starter in sheet steel enclosure AC 3 phase 415 volt 50 Hz suitable for 5/7.5HP complete. Make : Havells / Legrand / L&T / Siemens / ABB
Collecting water sample in clean bottle from location as directed for testing of physical test, chemical test, microbiological test as per IS-10500-1991 from NABL approved chemical laboratory and submitting test report complete.
M&L for scraping/cleaning surface of pipe lines of size 40mm to 150mm size and preparation of entire surface and applying one coat of Synthetic enamel paint epoxy coated ( Sea green colour for suction and discharge pipe lines) including writing, marking in stencil all as directed.
M&L for scraping/cleaning surface of pumpset, and preparation of entire surface and applying two coat of Synthetic enamel paint epoxy coated ( grey colour and red colour for fan cowl) all as directed.
Supply and fixing in repair of LED type under water pool light fitting made in stainless steel body having size approx 110mm dia x55mm thick, 6 watt capacity design to operate on 12 volt AC with individual step down transformer mounted over 65mm x65mmx5mm water proof ABS Box individual switching system complete in all resepct making electrical connection including taking down existing unserviceable light/driver and testing all as specified and directed code No LED 6W ION of Exchange or equivalent in approved makes.
Material and labour for cleaning of swimming pool of capacity 800000 ltr including provision of bleaching powder,brushes,bucket, pump etc.complete with draining out of water complete all as specified and directed
Material and labour for cleaning of balancing tank of capacity 100000 ltr including provision of bleaching powder,brushes,bucket, pump etc.complete with draining out of water complete all as specified and directed
Supply and fixing of under water pool light driver suitable for 6-12watt, including taking out of unserviceable light driver and testing all as specified and directed.
Supply and fixing of water proof ABS box of size as per ground requirement for mounting under water pool light driver including taking out old unserviceable box ,making electrical connection and testing complete all as specified and directed.Make-: Austin/Aquastar
Supply and adding Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containers complete all as specified and as directed.Brands having pan india availability, acceptability & being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. Note-: The chemical shall be brought in three lot and period to be procured only before previous batch completed.
Supply and adding Alum lump,grade I quality for treatment of swimming pool water
All as per item No. 73 above but Soda Ash of approved quality.
M&L for taking down old unsv and supply & lay 3 Core 6 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with necessary saddle, clamps, bolts & nuts, all For connection from panel to motor etc All as Directed. Make :- POLYCAB / PLAZA / HAVELLS.
M& L for complete servicing of ozonator unit of capacity 150 gms/hr, oxygen concentrator and panel PCB board comprising four visit in a year (i.e quarterly basis) and one emergency breakdown visit with testing complete all as specified and directed.
M & L for replacement of new mosfets and electronics component same as motherboard, new components from driver card, oxygen pipe with new calibrate flow meter with standard, electrode servicing, ht transformer servicing,new ozone pipe with pump water, cooling pipe connection, program IC replace with new, drier card tunning, venturi setting etc complete all as specified and directed. Note-: (i) Guarantee of performance not less than 3 months shall be submitted by the contractor.
Supply & fix in repair thermal overload relay of range 20-33 A (Manual Reset) complete all as specified and directed ,Make:-Siemens/schneider/L&T
Supply and fix in repair Contactor 3-Pole,suitable capacity as per ground requirement upto 40 HP complete all as specified and directed. Make:-Siemens/schneider/L&T
Supply and fixing water pressure gauge 0 to 14 Kg/Sq cm including clamps, nuts, bolts & washers complete all as specified and as directed..
M&L for earthing complete with GI plate electrode of size 600x600x6mm thick burried directly to ground vertically to a depth not less than 2.25 meter below the ground level connected to GI strip 32x6mm size and earthing lead protected with 40mm bore light grade GI pipe filling around with charcoal dust and salt including excavation returning filling of earth and disposal of surplus soil to a distance not exceeding 50 metre and connected to GI strip by means of nuts, bolts and washers to earth plate, as shown in electrical plate No 3 of SSR Part-I 2010, PCC chamber with making PCC M-10 (Nominal Mix type B-I using 20 mm graded stone aggregate reinforced with 8mm dia mild steel round bar @ 75 mm c/c both ways and 12mm dia mild steel plain bar lifting handle 02 Nos funnels with wire mesh 20 mm dia GI pipe light grade for watering copper lugs with CI frame and testing complete all as specified and directed. Note: GI strip exceeding 7.5m will be measured and paid seperately
Supply and laying , galvanised earth strip 25x4mm fixed on walls or through conduits /pipes etc including necessary fixing acessories complete all as specified and directed.
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 35 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Note : Cable shall be clamped on wall. Make : Polycab / Finolex / Havells / RR Kable
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Note : Cable shall be clamped on wall. Make : Polycab / Finolex / Havells / RR Kable
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core including necessary connection and providing cable lugs as required all as specified. Note : Cable shall be clamped on wall. Make : Polycab / Finolex / Havells / RR Kable
Supply and fixing in replacement of LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection 4 kv surge in built protection complete all as per directed by Engr- in – charge. NOTE-: The Contractor shall furnished 3 year minimum written warranty Clause on LED luminaries from OEM. Make : Bajaj/Crompton/wipro/Jaquar
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 130 x 180 x 77 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel cat part No KF1010B /National/Sintax
S&F sluice valve 80 mm bore, cast iron body, flanged and drilled end, conforming to IS-14846, ISI marked, Class PN 1.6 including all joints with rubber or fibre board, gaskets, bolts and nuts, washers, iron wheel including taking up / down old unserviceable valves from any position and any addition / alteration for fixing required complete all as specified and as directed. Make-: Kartar/ Kirloskar/ Upadhyay
All as per item No. 88 above but 100 mm dia bore complete. Make-: Kartar/ Kirloskar/ Upadhyay
All as per item No. 88 above but 150 mm dia bore complete. Make-: Kartar/ Kirloskar/ Upadhyay
S&F in repairs gunmetal gate or globe valve for 50 mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed. Make :- Kirloskar, Upadhaya , Leader, Zoloto.
All as per item No. 91 above but 40 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto.
All as per item No. 91 above but 25 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto.
All as per item No. 91 above but 20 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto.
Supplying, fixing, jointing and testing non-return valve suitable for GI tubing of size 80 mm bore size, (ISI Marked) both ends flanged and drilled for jointing including two flange joints and jointing material such as nuts, bolts washers rubber packing etc including taking down complete all as specified and as directed. Make :- Kirloskar, Upadhaya , Leader, Zoloto.
All as per item No. 95 above but 50 mm dia bore complete all as specified & directed.
Supply only Bleaching powder grade -I ISI marked having stable available chlorine % by mass minimum 35% as per IS 1065,1971 and packed in 25 Kg bag complete all as specified and directed. Make : Vikram or equivalent as approved by GE.
Maint/Cleaning of Pump house stations inside and out side area and removing of creepers and vegetation raised along with water supply installation including surface dressing around the E/M installation not less then 3 mtr from out side fencing and removing the all waste material from site and Chemical spray inside and out side area of Sub station. Note:- T & P will be arreanged by contractor
M & L for dismantiling the existing valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation D-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including necessary excavation earth work all plastered surfaces of valve chambers complete all as specified and directed by Engr-in-Charge.
Supply & Laying fixing, connecting and testing steel water tubing, medium grade, galvanised, with screwed and socketed joints, in any length, including supply and fixing all fittings, fixed to walls or laid in trenches / floors etc complete all as specified and as directed for the 20 mm bore, ISI marked. Make-: Tata/ Jindal/ BST/ Oswal
All as per item No. 100 above but 25 mm dia bore complete
All as per item No. 100 above but 40 mm dia bore complete
All as per item No. 100 above but 50 mm dia bore complete
All as per item No. 100 above but 80 mm dia bore complete
All as per item No. 100 above but 100 mm dia bore complete
Supply and fix ISI Marked UPVC Pipe size 50 mm nominal dia,pressure pipe Schedule 80 with all connected acessories like UPVC bend,Tees,Unions,Sockets etc for each 3 mtr length of Pipe & solvent to join it all as specified and as directed. Make:Supreme/Dutron/Finolex/Duplon
All as per item No. 106 above but 40 mm dia bore complete
All as per item No. 106 above but 25 mm dia bore complete
Taking down carefully ceiling fan, exhaust fan, wall / pedestal fan of any make and any sweep and dismentaling of blades canopy down rod etc & remove to store for repair. & Refix the same including provision of 3 core 0.5 sq mm copper flexiable cable from ceiling rose to connector. Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE on daily basis to carry out repairs to fan and the defects should be rectified on the same day
M&L of following for Opening of cleaning of slots, Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing complete all as directed by Engineer-in-Charge. Note - Spares such as Bearing, Capacitor, Capacitor Clamp, Rubber insulator will be measured seperately under respective item of this schedule
Ceiling fan 1200 / 1400 mm Sweep.
Exhaust Fan,Pedestal fan,wall fan, table fan 300/400 mm Sweep.
Exhaust Fan, Pedastal fan,wall fan, 450/600 mm Sweep.
Painting only of ceiling fan,exhaust fan,wall fan,pedestal fan for any size and type, sscraping out of old paint filling of cavities with filler preparation of body and cleaning of dust etc Painting by Spray with first Quality Paint including over quot of zinc primer writing of Mes number complete for all as directed :-
Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan,Table fan,Pedestal Fan any Make & any Sweep including dismantling/opening of body, cleaning of body, oiling, greasing & reassembling complete, replacing of split pin, nut , bolts etc and testing Note : Spares shall be measured & paid resperative item of this sch.
Supply only spare parts to be incorporated for repairing fans in respective item of this schedule
Capacitor up to 2.5 Mfd MAKE KELTRON,EPCOS
Capacitor 3.15/ 4 MFD MAKE KELTRON,EPCOS
Capacitor Clamp with Connector As Par Sample
Rubber Insulator sutiable for any type of Ceiling Fan.
Mild steel Down Rod 600 mm Long with Clamp nut bolts & split pin as par sample
Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par sample
Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc mplete 300 mm sweepas par sample
Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc complete380/ 450 mm sweepas par sample
Ball bearing sutiable for any type of fans Make : SKF,TATA,NBC
Mild steel shaft as per sample for any fan
Ceiling Fan Blade suitable for 1200/1400 mm sweep as per sample.
Exhaust Fan Blade suitable for 300 mm sweep as per sample.
Exhaust Fan Blade suitable for 450 mm sweep as per sample.
Pedestal/Wall Fan Blade suitable for 450 mm sweep as per sample.
Pedestal / Wall Fan Blade suitable for 600 mm sweep as per sample.
Supply & Fix Exhaust fan louvers with shutter made of aluminium sheet of 0.5 mm thickness, and frames made out of mild steel, making good the distrubed surfaces in CM 1:4, including scafolding if any required to carry out the work in building of height up to 32 Meters complete in all respects the
Deployment of Technician for Fan checking, Fan Servicing / Safety Hook/ Pin including fixing of safety pin, nut, bolt etc. complete and entry in register duly signed by User/ Occupants.Techniia will Carry scheduled preventative maintenance checks as per details to be given by Site Executive.
M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable piano switch 5 Amps & refixing switch plate and testing complete all as directed. Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day Make - Anchor, Leader, Plaza
M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable fan regulator & refixing switch plate and testing complete all as directed. Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day Make - Anchor, Leader, Plaza
S&F,in repair PVC laminated ISI marked top cover 3 mm including cutting/drilling holes for mounting housing of switches, sockets, etc as per site requirement suitable for following sizes of sunken/TW board. 4”x4” size
All as per Item No. 118 above but 7”x4” size
All as per Item No. 118 above but 8”x6” size
All as per Item No. 118 above but 8”x10” size
All as per Item No. 118 above but 10”x12” size
M & L taking down from position existing defective storage water heater 25 to 50 ltre storage Capacity for carrying out repairs work such as replacing worn out parts and fixing back in position in replacing the necessary nuts and bolts including disconnecting & reconnecting water & electric supply lines, testing, painting with two coats of white synthetic enameled paint by spray paint complete all as specified and directed
Supply only safety valve for geyser chromium plated brass 15 mm dia all as specified and directed Make :- Racold/ Bajaj
Supply only non return valve chromium plated brass 15 mm dia heavy-duty all as specified and directed Make :- Racold/ Bajaj
Supply only indicator lamp for geyser red/green, round/square/rectangle as per site requirement 230 V AC all as specified and directed Make :- Mimic / AE
Supply only heating element 1500 watt threaded or push type as per the existing one suitable for vertical storage water heater of any size all as specified and directed Make :- Racold/ Bajaj
Supply only heating element 2000 watt threaded or push type as per the existing one suitable for vertical storage water heater all as specified and directed Make :- Racold/ Bajaj
Supply only thermostat suitable for storage water heaters 25 to 50 Ltrs capacity adjustable type i.e.. 0 degree centigrade to 80 degree centigrade all as specified and directed Make :- Racold/ Bajaj
Supply and fix only plug top 3 pin 5 Amps capacity Make: Anchor ISI/LeaderISI/RIDER ISI
Supply and fix only plug top 3 pin 15/16 Amps capacity Make: Anchor ISI/LeaderISI/RIDER ISI
Supply and fix in repairs cable flexible 3 core PVC insulated and pvc sheathed with multi stranded copper conductor size of 0.75 sqmm 1100 volts grade all as specified and directed. Make Plaza, Havells
Supply and fix in replacement of copper water tank of 25 Ltrs capacity with and including necessary gasket packing, nuts, bolts, etc complete all as directed by Engr-in-Charge.
Fabricating, supply and fixing in replacement geyser bottom cover duly painted in two halves suitable for vertical type storage water 25/50 Ltrs capacity for geysers of any make as per the existing one all as specified and directed
Supply & Fix in replacement flexible 15 mm dia PVC pipe for cold water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed
Supply & Fix in replacement flexible 15 mm dia PVC pipe for hot water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed
Supply and fixing in repairs Sheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 20 Amps 240 Volts
Darpan Construction (BID ID -3168085)
shubham construction (BID ID -3168177)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .