GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
MAINTENANCE AND REPAIR TO CERTAIN MISCELLANEOUS EM ITEMS AND ALLIED WORKS RELATED TO EXTERNAL WATER SUPPLY AND EXTERNAL ELECTRIC SUPPLY AT AFS SAMBRA
2023_MES_632376_1
8824/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Sambra
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE AF Sambra
₹54,980
Yes
31 Jan 2024
12 Dec 2023
13 Jan 2024
12 Dec 2023
11 Jan 2024
29 Dec 2023
Amount
M & L Disconnecting and taking down of FRP tank of capacity 150litres of dosing system, complete removal of existing treatment of old painted steel surfaces of heavy duty mild steel fabricated frame/stand, applying two coats of yellow colour synthetic enamel paint over a coat of red oxide primer and refixing back FRP tank on its original position complete all as specified and as directed.
S & F in repair PVC Level Gauge for 150 Ltrs FRP Tank of dosing system complete all as specified and as directed.
M & L Dismantling the 0.5HP Dosing pump set from Dosing system by disconnecting carefully and dismantling, opening complete pump set, cleaning, replacing of unserviceable parts such as gun metal bushes, rubber packing, M S Nut, Bolts, rubber coupling (spider), Air valve and other worn out parts etc and re-assembling, installing back on original position, testing for smooth running complete all as specified and as directed.
S&F in repair agiator having stainless steel sweep blade duly FRP coated in Chemical Dosing Sysyem complete all as specified and as directed.
M & L mixing of Crystal Alum to Water Treatment Plant (WTP) complete all as specified and directed. Note : (i) Tenderer shall employ suitable employee to mix chemical to water daily 40 to 50kg as per requirement. (ii) Tenderer shall keep/maintain minimum 15days stock of chemical.
S & F in repairs pressure gauge with isolating valve and siphon 0-7Kgf range with 40mm dia premium quality material body to withstand pressure rating as per site requirement complete all as directed
S & F in repair Water tubing 15 mm dia Unplasticised PVC pipes, of pressure rating 10 kgf/sqcm laid on floors all as specified and directed.
S & F in repair gun metal globe / gate valve with iron wheel based screwed both ends for iron pipe 15 mm dia complete all as specified and directed.
S & F in repair Direct -on- Line(DOL) Motor Starter for 0.75HP Motor set including contactor, over load relay & connected wiring etc complete all as specified and as directed.
M&L Mild steel angle, channels or tee sections, fixed independently, without connection plate, etc grade Fe 410 including necessary drilled holes, welded together all as specified and as directed.
M & L Pre-cast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in solid block masonary exc 10cm in width and setting in CM 1:6 all as specified and as directed.
M & L mixing HI strength calcium based chlorine granular (calcium Hypochlorite ) Ca (CIO)2 (minimum chlorine content 65-70%) for water treatment packing in 45 Kg plastic drums stacked in the Water Treatment Plant (WTP), P/H No 2, P/H No 4, P/H No 5 and P/H No 6 complete all as specified and directed. Note : (i) Tenderer shall employ suitable employee to mix chemical to water daily 12 to 15kg as per requirement. (ii) Tenderer shall keep/maintain minimum 15days stock of chemical always.
Supply , install, testing and commissioning of LT feeder pillar box, CPRI Approved, AC 415 Volts , 50 HZ, 3 Phase 4 wire of suitable size for accomodating the following accessories, totally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands, structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 40X40X3 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated, complete all as specified
BUSBAR :- (i) Aluminium bus bar 200 Amps, 415 Volt , supported on non hygroscopic fibres, studs and brass screws for mounting -04 Nos INCOMER (a) Supply and fixing MCCB of 4 pole of capacity 125 amps with breaking capacity of 16 KA adjustable thermal and magnetic setting - 01 Nos INDICATING DEVICES (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B set of 3 - 01 No (b) Supply and Fixing Digital Metering Unit with ammeter, Voltmeter and Phase Indicator - 01 No Each OUTGOING FEEDERS (a) Supply and fixing MCCB of 4 pole of capacity 63 amps with breaking capacity of 10 KA adjustable thermal and magnetic setting - 01 Nos (b) Supply and fixing MCCB of 4 pole of capacity 32 amps with breaking capacity of 10 KA adjustable thermal and magnetic setting - 02 Nos
Dismantling and taking down unserviceable street light, HPMV/HPSV/MH/LED fitting from the pole/High mast pole/Building including disconnecting the cable connections and refixing the same on pole and connecting up, testing complete after necessary repairs to fitting and replacing chokes, capacitors, ignitors, lamp, lamp holders, drivers, connectors etc. wherever required for HPMV/HPSV/MH/LED lamp fittings of 25W/30W/45W/70W/100W/150W/250W all as directed
S & F bracket for street light fitting made out of 40 mm dia light grade GI tubing bend to required shape 1.5 m long including necessary GI clamps, nuts bolts and washers and fixing to the pole complete including taking down old rusted bracket including un-serviceable GI clamps, nut & bolts from the pole as directed.
S & F FRP junction box of size 295 mm x 255 mm x 160 mm with self locking arrangement comprising of one No MCB SP 06 Amps with suitable din chanel, 4 way 32Amps PVC connector fixed to pole with Flat iron clamps of size 25x4 mm, nuts and bolts and connecting the incoming and out going cables, including taking down old existing unserviceable junction box all as specified & as directed.
S & F Power contactor 3 pole 32 Amps rated capacity, 50 cycles 220/240 volts, including Incoming & outgoing wiring with copper conductor of 10 sq mm size with suitable copper lugs and taking down the existing unserviceable contactor complete all as specified & directed.
S & F PLUTO PRO LED Flood light fittings 200 Watt, presure die cast aluminium housing, toughened glass and high power LEDs, secondary lenses with IP 66 protection including Surge Protection Devices 10 KV, Heat resistant, resistant TRS cable, 6000-6500K cool white colour complete with all accessories & necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etc including taking down old unserviceable fitting all as specified & directed.
S&F PLUTO PRO LED Flood light fittings 150 Watt with presure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection including SPD 10 KV complete with all accessories & all necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etc all as specified & directed including taking down old US Fitting.
S & F ROVER PRO LED Flood light fittings 100 Watt with presure die cast aluminium housing, toughened glass and high power LEDs, secondary lenses, IP 66 protection, surge protector device 10 KV, with all accessories & necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etc including taking down old unserviceable fitting all as specified & directed.
S & F SURROUND ULTRA high efficiency round highbay of 150 wattage, PDC housing, luminiare shall have effacacy upto 130 Lm/Watt, IP 66 protection & all necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etc including taking down old unserviceable fitting all as specified & directed.
S & F ROVER PRO LED Flood light fittings 50 Watt with presure die cast aluminium housing, toughened glass, high power LEDs, secondary lenses, IP 66 protection, surge protector device 10 KV with all accessories & necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etc including taking down old unserviceable fitting all as specified & directed.
Taking down LED light fittings of any capacity from pole, dismantling & removing the carbon from existing cable and refixing back on the pole all as specified & directed.
Dismantling and taking out existing unserviceable disconnected cables of following sizes from its existing location :-
2 core 10 sqmm
2 core 16 sqmm
4 Core16 Sqmm
4 core 25 sqmm
3.5 core 50 sqmm
M & L L T under ground XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade in trenches / passing through pipes of following cross-sectional area :-
2 core 10 sqmm
2 core 16 sqmm
4 Core16 Sqmm
4 core 25 sqmm
3.5 core 50 sqmm
S & F Double walled corrugated HDPE Pipe IS-16205, size inner dia 63 mm, outer dia 75 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler with rubber rings, pipe joint lubricant with all fittings as required at site complete all as specified and as directed
S & F double walled corrugated HDPE Pipe IS-16205, size outer dia 40 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler with rubber rings,pipe joint lubricant with all fittings as required at site complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying cables and getting out in hard / dense soil for laying cable/erecting poles all as specified & directed
All as per item No 29 here-in-before but exceeding 1.5 m deep and not exceeding 3.0 m deep.
Returning and filling in soil including spreading leveling watering and well ramming in layers not exceeding 25cm all as specified & directed
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified & directed
M & L Galvanised Iron tubing, light grade, 40 mm dia for cable protection including taking down the unserviceable tubing all as specified & directed
M & L PVC insulated flat twin core sheathed 6 sqmm stranded aluminium conductor 1.1 KV grade cable including taking down old unserviceable cable all as specified & directed
M & L for PVC insulated flat twin core sheathed 10 sqmm stranded aluminium conductor 1.1 KV grade cable including taking down old unserviceable cable all as specified & directed
M & L for PVC insulated flat twin core sheathed 16 sqmm stranded aluminium conductor 1.1 KV grade cable including taking down old unserviceable cable all as specified & directed
M&L Aluminium ladscape luminaries for diffused lighting with high power LED 8 watt, Bamboo-IP-66 new generation, energy saving, environmental freindly, long life aesthetically designed including neccassary excavation and PCC foundation for erecting bollard as per manufacture recomendation including taking down old unserviceable fitting all as specified & directed
M & L Pre-stressed concrete pole 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 complete all as specified and directed including taking down old unserviceable fitting all as specified & directed.
M & L Plain cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation filling for poles complete all as specified.
M&L Plain cement concrete 1:2:4 type B-2 using 40 mm graded crushed stone aggregate) coping for poles complete all as specified including breaking the old coping for laying cable all as specified and directed.
S & F street light fitting ASTRA NEO LED 25 watt, pressure die cast housing, toughened glass and high power LEDs with secondary optics, IP-66 protection including necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etc including taking down Old unserviceable fitting all as specified and directed
S & F Street light fitting ASTRA NEO LED 45 watt, pressure die cast housing,toughened glass,high power LEDs with secondary optics, IP-66 protection including necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etc including taking down Old unserviceable fitting all as specified and directed.
M & L Cutting the tar macadam road / hard standings for laying cable and excavating not exceeding 0.45m wide and 0.6m in depth and getting out including filing back and finishing it with 200mm rthick PCC 1:4:8 type D-2 complete all as specified and directed.
S & F Driver for LED light fitting of following specification complete all as specified and directed:-
25 W LED Driver
45 W LED Driver
50 W LED Driver
100 W LED Driver
200 W LED Driver
250 W LED Driver
Material and labour chemical earthing pit of suitable size with copper earth plate of size 900 mm x 600 mm x 5 mm thick burried directly in ground vertically to a depth not less than 4 metre below ground level with top edge of plate at a depth not less than 2.95 metre below nominal ground level with a bottom layer MgSO4 of 100 mm thick or 100kg whichever is more, earth plate surrounded with graphite powder, vegetable soil mixture, charcoal 250kg and salt crystal 200 kg around and 150 mm above the plate and MgSO4 100 mm thick or 100kg whichever is more at top layer and the remaining portion filled with excavated earth and connected with copper strip 32mm x 6mm duly brazed and by means of bolts, nuts and washers of copper upto 7.5 metre length with G I pipe light grade of suitable dia not less than 40 mm for earth strip protection and connected to earthing test point,
GI pipe medium grade 25mm bore for watering with funnel and wire mesh complete including provision of earth pit with necessary earth work, PCC 1:2:4 type B1 chamber, Cast iron frame with hinged pit cover of size 12” x 12” having not less than 7 kilogram of weight , testing on completion complete all as specified & directed
Supply, install, testing and commissioning of floor mounted LT feedar pillar box, AC, 415 Volts, 50 HZ, 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs, hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated, complete all as specified and directed :- NOTE:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires.
BUSBAR :- (a) Electronic aluminium bus bar 600 Amps, supported on non hygroscopic fibres and GI screws for mounting -04 Nos MPP-H CAPACITOR :- (a) S & F capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 Volts, 50 Hz System for permissible non-linear load 15% of 5 KVAR capacity - 01 No (a) S & F capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 Volts, 50 Hz System for permissible non-linear load 15% of 10 KVAR capacity - 01 No
Supply, install, testing and commissioning of floor mounted LT feedar pillar board AC 415 Volts, 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs, hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated, complete all as specified and directed :- NOTE:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires.
OUTGOING FEEDERS (a) S & F MCCB 4 pole, 415 Volts of breaking capacity 16 KA, 32 Amps with Adjustable type - 02 Nos (b) S & F MCCB 4 pole, 415 Volts of breaking capacity 16 KA, 25 Amps with Adjustable type - 02 Nos (c) S & F MCB SPN, C Curve, 240 Volts of breaking capacity 10 KA, 32 Amps - 02 Nos
Supply , install, testing and commissioning of LT feeder pillar box, in repairs, CPRI Approved AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 40X40X3 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified
BUSBAR :- (i) Aluminium bus bar 200 Amps, 415 Volt , supported on non hygroscopic fibres, studs and brass screws for mounting -04 Nos INCOMER (a) Supply and fixing MCCB of 4 pole of capacity 100 amps with breaking capacity of 16 KA adjustable thermal and magnetic setting - 01 Nos (Make - L&T / Havells / Snider)
INDICATING DEVICES (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B set of 3 - 01 Nos (b) Supply and Fixing Digital Metering Unit with ammeter, Voltmeter and Phase Indicator - 01 No Each OUTGOING FEEDERS (a) Supply and fixing MCCB of 4 pole of capacity 63 amps with breaking capacity of 10 KA adjustable thermal and magnetic setting - 01 Nos (Make - L&T / Havells / Snider) (b) Supply and fixing MCCB of 4 pole of capacity 32 amps with breaking capacity of 10 KA adjustable thermal and magnetic setting - 02 Nos (Make - L&T / Havells / Snider)
Material & Labour for mixing of Poly Aluminium Chloride (PAC) for Water Treatment at Swimming Pool, STP South & North complete all as specified and directed. Note : (i) Tenderer shall employ suitable employee to mix chemical to water daily 30 to 40kg as per requirement. (ii) Tenderer shall keep/maintain minimum 15days stock of chemical.
M/s PRATAP VIJAYSINGHRAO DESAI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .