Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
11 Sept 2026, 2:00 pm
Additional Chief Executive Officer Z P Satara
Additional Chief Executive Officer Z P Satara
BEAUTIFICATION OF MANDIR PREMISES, CONSTRUCTION OF BHOJANKAKSH, PROTECTION WALL, MALE AND FEMALE TOILET BATH UNIT, VAHANTALAND ELECTRIFICATION AT GHATAIDEVI DEVSTHAN GHATVAN TALDIST-SATARA
2026_SATAR_1329243_1
work/North/L-6/B-varg/12/26
Open Tender
Civil Works
Percentage
365 days
BEAUTIFICATION OF MANDIR PREMISES, CONSTRUCTION O
OPEN
11 documents required · 11 mandatory
₹10,000
₹2.1 L
Additional Chief Executive Officer Z P Satara
18 Aug 2026
18 Aug 2026
14 Sept 2026
18 Aug 2026
11 Sept 2026
18 Aug 2026
1 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. By Mechanical Means. Item / Page No : 11 / 23 Specification No : MORTH-301 Spec. Page No : 45-53 Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge. | |||||
| 2 | Providing soling using 80 milimetre size trap metal in 15 centimetre layer including filling voids with crushed sand / grit, ramming, watering, excetra complete.
Item / Page No : 40 / 157
Additional Specifications : The work shall be carried out as per instructions of Engineer in-charge. | - | Cubic Metre | 1 | - |
| 3Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND). Item / Page No : 1 / 175 Specification No : Bd.E.1 Spec. Page No : 287-288 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | |||||
| 4 | Providing and laying in situ cement concrete M-20 with tremix treatment for 100 milimetre thickness for flooring with groove cutting of 4 milimetre wide 20 milimetre deep with necessary refilling with bitumen, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 30 / 216
Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Square Metre | 1 | - |
| 5Providing and fixing heavy duty inter locking concrete rubber mould glossy paving blocks of 60 milimetre thickness of having a strength of 400 kilogram per square centimetre of approved quality and shape on a bed of crushed sand of 25 milimetre to 30 milimetre thick including striking joints and cleaning excetra complete.(using 100 per cent crushed sand), excetra complete. Item / Page No : 53 / 219 Specification No : Bd.M-12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. | |||||
| 6 | Providing and laying Cast in situ / Ready Mix cement concrete M-15 of trap / granite / quartzite / gneiss metal for steps including steel centering, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 4 / 175
Specification No : Bd.E.2, B-7
Spec. Page No : 288, 38-40
Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Cubic Metre | 1 | ₹1 |
| 7 | Providing and fixing 50 milimetre diameter and 1.5 milimetre thick stainless steel hand railing in stainless steel 304 grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For Ground Floor)
Item / Page No : 111 / 379
Additional Specifications : The work shall be done as per instructions of Engineer in charge. | - | Running Metre | 1 | - |
| 8Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:6. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | |||||
| 9 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 7 / 209
Specification No : Bd.L.4
Spec. Page No : 368
Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Square Metre | 1 | - |
| 10Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. Item / Page No : 37 / 157 Specification No : Bd.A.11 Spec. Page No : 263-264 | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.72 MB
B1ghataidevi.pdf
Tender Documents • 5.99 MB
BOQ_2275664.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].