| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.7 LAccepted-AOC 10 370 NEAR GEETA MANDIR GAS GODAM ROAD OBRA OBRA SONBHADRA UTTAR PRADESH 231219 INDIA | SONBHADRA | UTTAR PRADESH | 231219 | 1 | Accepted-AOC l1 | |
| 2 | 2₹30.3 L+₹3.7 L (13.7%)Rejected-AOC | 2 | Rejected-AOC l2 | |
| 3 | 3₹33.7 L+₹7.0 L (26.3%)Rejected-AOC PATIALA | PATIALA | 3 | Rejected-AOC l3 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
13 Oct 2021, 10:00 amClosed
Sr Xen Ciivil Mtc P and M Division Patiala
Sr Xen Ciivil Mtc P and M Division Patiala FLAT NO 29 SHAKTI VIHAR PATIALA
special repair to resisdence quarters of D E and F type at 220 kv sUB STATION Mohali 1
2021_POWER_73232_1
89/21-22
Open Tender
Civil Works
Item Rate
180 days
Patiala
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹68,000
Yes
11 Dec 2021
1 Oct 2021
13 Oct 2021
1 Oct 2021
13 Oct 2021
1 Oct 2021
Amount
CSR ITEMS (RATES APPROVED BY CE/ TS PSTCL AFTER IMPLEMENTATION OF GST)
Shuttering for beams LINTELS OF e 14 CSR 9.6
Shuttering for slab E-14 CSR 9.8
Centring and shuttering for parapet,facias and other similar items including edges.CSR 9.10
M-20 conc. In super structure CSR 10.20
First class burnt brick work laid in cement sand mortar 1:5 in super structure above plinth.CSR 11.6
P/f 110 mm UPVC rain water pipe 2.5 Kg/Sqm pressure including jointing during masonary complete for E-14 CSR 13.74
P/f 110 mm UPVC bend for rain water pipe CSR 13.75
40 mm thick conglomerate floor 1:2:4 on CC 1:8:16 100 mm thick on 100mm thick sand or stone filling CSR 14.9
P/f ceremic tiles on wall of 200x300 mm CSR 14.125
P/f non skid tiles of 300x300mm CSR 14.72
12.5 mm thick cement plaster 1:5 CSR 15.10
20 mm thick cement plaster 1:5 CSR 15.21
10 mm thick ceiling plaster 1:3 CSR 15.43
Red meranti super door shutters with 12 mm thick phenol bonded BWP plywood complete fixed in position 35 mm thick CSR 17.10 II (XI)
Bansam Champ wood window shutter in/c hinges,cleats,stops cord etc complete fixed in position for 35 mm thick CSR 17.10 (xxiii)(a) (ii)
Wire gauge Red Merananti super door shutter without spring housed in chowkhat 35 mm thick CSR 17.11 (vii)
Red meranti super cup board shutters with plywood pannels or faced on both side fixed in position exclding cost of handles,bolts etc but including the labour for fixing them.csr 17.12 (vii) (a)
Red meranti super wood cup board chowkhat includinh iron hold fast,iron hinges coners,straps,wooden knobs or handles fixed in position of size 45x60 mm.CSR 17.16 (vii)
Cost of aluminium fittings CSR 17.23 ii
P/F glass panes with nails& putty or wooden strips complete in all respact 4 mm thick CSR 17.26 (b) (ii)
Wrought iro or Mild steel ladders,framed gills,grating,etc. with end bars complete as per CSR 18.4
P/F MS chowkhats of size single rebate CSR 18.24 A
P/F MS chowkhats of size double rebate CSR 18.24 C
Scraping of old white wash/distemper etc 8.31 A
Colour wash 3 coats CSR 16.5
White wash 3 coats CSR 16.3
Applying dry distemper on walls CSR 16.9
Painting two coat with synthetic enamel paint in all shades on old wood work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint.CSR Specification 16.18
Removing of doors and windows
(i) Doors CSR 8.38 I
(ii) windows CSR 8.38 II
Prroviding and fixing glass strips of 4 mm thick CSR 14.105 B
Finsihing walls with exterior decorative snowcem CSR 16.14
Wire gauge on door and windows NS
Conglomate floor 40 mm thick 1:2:4 CSR 14.6
Floating coat of 1.5 mm thick neat cement laid in one operation to the topping CSR 14.4
Disamntling of rcc of existing water tanks (walls only) CSR 8.6 E
Scraping of cement plaster CSR 8.31 C
Loading and unloadng of malba of dismantled CSR 4.1 A
Disposal of dismantled material with in yard area with a lead of 300 rmt CSR 5.1 i
Providing and fixing in position Chinaware European type water closet P trap or S trap (to the approval of the Engineer-in-charge) suite-consisting of 10 ltr. PVC flushing cistern supported on angle iron bracket, short bend 32 mm dia including cost of solid white cover complete in all respect and to the entire satisfaction of engineer in CSR 30.4
Providing and fixing in position best Indian make white ordinary lavatory suites consisting of C.P. brass waste 32mm dia, pair of angle iron bracket with one C.P. brass tap complete.Size 550 mm x 400 mm CSR 30.32 ii
Providing & Fixing in positionplastik moulded frame morror size 550x400 mm complete as per CSR 30.62 a
Providing & fixing in position PVC water storage tanks triple layer make as approves by Engineer-in-Charge including hosting and carriage from store to site of work complete with providing and fixing 15mm or 20mm internal Diametre tanki nipple complete.(Excluding cost of platform).CSR 30.97 (A) ii
p&f in poistion automatic brass ball cock in tanks 20 mm dia CSR 30.96 B ii
P&f in poistion gully trap CSR 30.99 A
P and f SWR upvc soil waste as per IS 13592 of EDC manufacture complete but excluding cost of joint (i) 110 o/d single socket pipe laid csr 30.74 iii B (B)
P and f SWR upvc soil waste as per IS 13592 of EDC manufacture complete but excluding cost of joint (ii) 75 mm dia CSR 30.74 iii (B)(d)
Poviding PVC solvent cement joint to SWR pipe and specials including cost of solvent 110 mm CSR 30.77 c (b)
Poviding PVC solvent cement joint to SWR pipe and specials including cost of solvent 75 mm CSR 30.77c (d)
P and f of SWR upvc special for soil waste pipe as per IS coupler 110 mm dia P trap CSR 30.81(iii) B (ix)
P trap/floor trap 75 mm CSR 30.81 (iii) D (viii)
Cutting chase in brick wall in cement or in floor for embeding pipes 75X75MM CSR 30.85 A
Cutting chase in brick wall in cement or in floor for embeding pipes 150 x 150 CSR 30.85 B
Providing & Fixing in postion 15 mm i/d bib cock of best quality (as approved by the Engineer-in-charge).CSR 30.65 A iii
Providing & Fixing in postion 15 mm i/d stop cock of best quality (as approved by the Engineer-in-charge).CSR 30.66 C
p and f PVC flexible tube connection CSR 30.72 A
Earth work in excavation manually CSR 29.1 (A) i
P&L in trenches and jointing of HDPE pipes having ISI specification complete as per CSR 110 mm dia pipe CSR 29.44 A
Construction of inspection chamber of size 450x450 with RCC cover light duty CSR 29.60 A
P & f UPVC pipe with GI specials as per ISI 4985 (a) 20 mm dia CSR 28.11 A(a)
P & f UPVC pipe with GI specials as per ISI 4985 (b)25 mm dia CSR 28.11 A (b)
P&F Sink CSR 30.47 b
RECESSED CONDUIT PIPE WIRING SYSTEM WITH Paino SWITCHES: Fan Box andElectronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:-
Wiring fan point without fan box in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts (two module). CSR 34.08 A I B
Wiring light point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade. CSR 34.08 A ii
Wiring call-bell point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with bell push and electronic buzzer 230 volts AC (including the cost of bell push, electronic buzzer & powder coated concealed metal box for electronic buzzer).CSR 34.08 A iii
Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade.CSR 34.08 A iv
Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch.CSR 34.08 A vi
PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated single core FRLS copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and erection of pipe or casing.
PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq.mm, 1100volts grade CSR 34.09 ii
PVC insulated copper conductor single core FRLS cable (ISI marked) overall 4 sq.mm, 1100volts grade CSR 34.09 IV
P and f PVC conduit pipe heavy duty complete as per CSR 25 mm dia CSR 34.12 x
Supply and erection of MCB for circuit protection complete as per CSR single core 6 to 32 AMP CSR 34.16A(iii)
MCB double core CSR 34.16 A(Vii)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: CSR 34.17 ii
Extra carriage beyoud 5 km and difference in quarry rates( cheap lending rates)
Cement AOR
Fine sand AOR
Coarse sand AOR
Coarse aggregates 13.2 mm AOR
Coarse aggregates 11.2 mm AOR
BricksAOR
Less scrap of damaged GI pipes AOR
Less scrap of damaged doors and windows AOR
M/s Mukul Kumar Prajapati
The A and T Coop LC Society Ltd Patiala
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .