Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹30.6 L+₹10,345 (0.34%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹30.7 L+₹17,606 (0.58%)Rejected-Finance G 124 FLAT NO 4 DILSHAD COLONY DELHI 110095 | SHAHDARA | DELHI | 110095 | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | L4₹36.9 L+₹6.3 L (20.8%)Rejected-Finance | L4 | Rejected-Finance BIDDER NOT LOWEST | |
| 5 | L5₹38.8 L+₹8.3 L (27.1%)Rejected-Finance | L5 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹46.0 L
EMD Value
₹91,920
Closing Date
10 May 2022, 6:00 pmClosed
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
SPECIAL REPAIR FOR RE WIRING OF BLDG NO P 257 P 261 P 266 P 271 P 272 P 283 P 299 OF 2 GARH RIF AND PROVN OF 2 SOLAR WATER HEATING SYSTEM IN JCOS ORS OTHER THAN MARRIED ACCN OF 285 FD WORKSHOP UNDER GE WEST DELHI CANTT 10
2021_MES_492751_2
GE/DW-92/2021-22
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹91,920
27 Jun 2022
13 Apr 2022
12 May 2022
14 Apr 2022
10 May 2022
28 Apr 2022
Amount
Supply, Install, Testing and Commissioning of 'Solar Water Heating System' (Flat Plate Collector type conform to IS 12933 as amended upto date based on indirect transfer of heat of capacity 300 LPD including electrical heating back up with thermostate including all civil wks, frame mounting structure for collector box, frame for support structure for hot water tank and collector with anti corrosive coating,insulated hot water tank ( made with graded stainless steel of cap 1000 ltrs, confirm to IS 1730 grade), temp. gauge ,water meter and connection for heating backup etc complete all as per latest provision and section 26 to 26.11.1(c) of SSR Pt-I 2009 and as dircted . Note: All components, equipments and accessories shall be conforming to latest indian standards as applicable. The installation shall comply with the applicable codes of practice ( wherever such codes of practice issued by the competent authority ) regulations and indian electricity rules and other safety regulations.
S & F 3 layer 15 mm dia Hot PP-R polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV stabilsed and antimicrobial welded having thermal stability for hot & cold water suppy including all PP-R plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors etc. with all fitiings like socket, reducer,bend etc.fixed complete all as specified and directed
M&L for Wiring for circuit/submain wiring alongwith earth wire with 3x6qmm FRLS PVC insulated copper conductor, single core cable through and including PVC rigid conceal conduit of suitable size as required complete all as specified and directed.
S&F single pole enclosure with a two pin and earth plug and socket complete with one double pole 20 Amp MCB complete all as specified and directed.
M&L for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as required the system all as specified in SSR Part I of capacity 1000 ltrs including provn of PVC 20 mm bore float valve and making inlet and outlet pipe connection and all accessories complete all as specified and directed
S&F 25 mm bore GI tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors including making connection with existing pipeline complete all as specified and directed.
S&F 20 mm bore GI tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors including making connection with existing pipeline complete all as specified and directed.
S & F 25 mm Gun-metal gate valves,with iron wheelhead, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F 20 mm Gun-metal gate valves,with iron wheelhead, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F 15 mm Stop valves, cast copper alloy,screwed down,high pressure,with crutch or butterfly handle,screwed bothends for ironpipe or forunions and fixed complete all as specified and directed.
S&F 15mm bore fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
M&L angle iron stand for cold water tank made out of Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets. Note:-Complete stand to fixed on roof properly and Grouting the MS plate of 150 X 150 X10 mm all as directed.
Taking down carefully copper/aluminium point wiring (light/fan socket or power) complete including fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc and removing the material from site including making good the disturbed surface to match with the existing all as specified and directed.
Material and labour for concealed point wiring with PVC insulated unsheathed multistranded colour code copper conductor in PVC conduit with FRLS cable1.5 Sqmm size 1100 volts grade conforming to IS:694 in new GI boxes of 1.6 mm thick including one coat of synthetic enmelled black paint and providing new 3mm thick plastic laminated sheet cover of required colour fixed with brass screws and cup washers including single core stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit all as specified and directed by Engr-in-charge for the following :-(a) One light/fan/Exhaust fan/bell point controlled by one switch.
(b) All as per item No. 14 (a) here in before but for One 5 Amp socket out let independent.
(c) All as per item No. 14 (a) here in before but for One 5 Amp socket out let on same board
Material and Labour for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade conforming to IS:694 in new GI boxes of 1.6 mm thick including one coat of syenthetic enamelled black paint with new 3mm thick plastic laminated sheet cover of required colour fixed with brass screws and cup washers including single core stranded FRLS copper conductor 1.5Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for One 3 Pin socket 15A Indepentent board
S&F switch Piano flush type SP, one way 5 Amps complete all as specified and directed.
S&F switch Piano flush type SP, one way 15 Amps complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5 Amps. complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5 and 15 Amps, flush type complete all as specified and directed.
S&F polycarbonate ceiling rose 3 pin flush type 6 A 250 V AC with ISI mark including ring for jumbo ceiling rose complete all as specified and directed.
S&F electronic fan regulator 0-4 steps step 100 W hum free including 6A socket frame and including connections complete all as specified and directed..
S&F in replacement of 7 Watt LED lamp 6500K, complete all as specified and directed..
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexiblecopper conductor cable of suitable size complete all as specified and directed.
S&F single pole MCB 6 to 32 Amps 240 v, 50 Hz AC suitable for 'B' Series" conforming to IS 8828 of 1996 including taking down old MCB's all as specified.
S&F single pole MCB 40 Amps 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828 of 1996 all as specified. .
S&F of SPN 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity and terminal box suitable upto 63 sqmm cable complete conforming to IS 8828 of 1996 all as specified.
S&F in repair of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in of MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F in repair of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
Taking down sub main wiring off sizes complete all as specified and directed.
S&F submain concealed wiring alongwith earth wire with 2 runs of 6 Sqmm (Main Cable and neutral) and one run of 6 Sqmm as earth wire of multistranded unsheathed colour code FRLS PVC insulated copper conductor, single core cable drawn through and including rigid PVC conduit of size 25 mm dia with all fittings and accessories all as directed.
Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed.
S&F single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
S&F Exhaust fan metallic type ventilating single phase 230/240V of 300mm sweep with Louvre including cutting of holes in a round shape and including fixing the ventilating fan complete all as specified and directed.
S&F Exhaust fan metallic type ventilating single phase 230/240V of 450mm sweep with Louvre including cutting of holes in a round shape and including fixing the ventilating fan complete all as specified and directed.
Taking down existing ceiling fan and deposit in MES Yard complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
S & F in replacement Lamp holder with insulated body with back plate suitable for batten fitting complete all as specified and directed..
S&F of electric storage water heater of capacity 25 ltr BEE 5 star with vtreous enamel coating with all accessories and fittings arrangements and testing after installation complete all as specified and directed.
Supply and fixing PVC Fresh Air exhaust fan 250 mm single phase, 230/240 V With Louvre including cutting of holes in a round shape (Precast piece to be incorporated for smooth and ever finish) and including fixing the exhaust fan complete all as specified.
Deduct Credit: for demolished/dismantled material of (-) Rs 112945.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum.
M/s Adhikari construction co.
sunil traders
Surjit and Sons
M/S GUPTA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .