| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | ₹19.9 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹21.6 L+₹1.8 L (8.91%)Rejected-Finance | ₹21.6 L+₹1.8 L (8.91%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹21.9 L+₹2.1 L (10.3%)Rejected-Finance VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | ₹21.9 L+₹2.1 L (10.3%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹22.6 L+₹2.7 L (13.7%)Rejected-Finance | ₹22.6 L+₹2.7 L (13.7%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹22.8 L+₹3.0 L (14.9%)Rejected-Finance D 9 NETAJI NAGAR KANTATOLI COLONY RANCHI 834001 | RANCHI | RANCHI | JHARKHAND | 834001 | ₹22.8 L+₹3.0 L (14.9%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹24.2 L
EMD Value
₹48,500
Closing Date
7 Mar 2023, 6:00 pmClosed
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT P.O. HOTWAR RANCHI - 834012
PROVN OF STATION LPG STORE WITH MASTIC FLOORING IN ASC BN AT DIPATOLI POCKET OF RANCHI MIL STATION
2023_MES_581055_1
8000/1873/E8
Open Tender
Civil Works
Item Rate
120 days
Deepatoli
Class E, Category a(i)
8 documents required · 8 mandatory
₹500
Yes
GE Dipatoli
₹48,500
Yes
3 Apr 2023
15 Feb 2023
9 Mar 2023
15 Feb 2023
7 Mar 2023
1 Mar 2023
Amount
Surface dressing n exc 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed
Returning/filling in layer n'exc 25 cm thick including spreading, levelling watering well ramming etc, complete all as specified and directed
Removing excavated soil to distance exc 1.5m but n'exc 5.0 Km and deposited complete all as specified and directed.
M&L PCC (1:4:8) type D-2 using 40mm graded stone agg as in fdn filling mass concrete, complete all as specified and directed
M&L Reinforced cement concrete in design mix M-25 (using 20mm graded aggregates) as in foundations, including rafts, footings, plinth beams etc complete all as specified and directed.
M&L Reinforced cement concrete in design mix M-25 (using 20mm graded aggregates) as in columns, pillars piers, posts and struts etc complete all as specified and directed.
M&L Reinforced cement concrete in design mix M-25 (using 20mm graded aggregates) as in chajjas etc complete all as specified and directed.
M&L Reinforced cement concrete in design mix M-25 (using 20mm graded aggregates) as in beam, cantilevers, bressummers, lintel over 1.5m span etc complete all as specified and directed.
M&L formwork to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits of foundation and plinth beam, and similar work, vertical or batter work fair finished flat surface of concrete complete all as specified and directed.
M&L formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished square, rectangular or polygonal and complete all as specified and directed
M&L formwork to chullah hoods, chajjas, trughs and similar items in cluding edges rough finished surfaces of flat concrete and complete all as specified and directed
M&L formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves incuding supports, overhangs, etc also splays between floors and beams etc rough finished flat surfaces of concrete and complete all as specified and directed
S&F mild steel bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 09mm dia or securing with clips, complete all as specified and directed
Ditto as item No 14 above, but dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, old size bricks built in CM (1:6), complete all as specified and directed
M&L 15mm thick plastering on wall concrete surfaces in CM (1:6) finished even and smooth w/o using extra cement, complete all as specified and directed
M&L 15mm thick rendering in CM (1:4) on brick/concrete surface, finished the surface even and fair with using wpc. (wpc shall be measured and paid seperetely), complete all as specified and directed
Supply only integral water proofing compound, complete all as specified and directed
M&L hard core of gauge n'exc 63 mm of broken bricks deposited spread and leveled in layers n. exc 15cm thick, watered and rammed to a true surface, complete all as specified and directed
M&L for 50 micron polythene film laid on floor, complete all as specified and directed
M&L for spreading and levelling of sand in layers n. exc 25 cm thick over sub base, complete all as specified and directed
M&L cement concrete 75mm thick as in sub base of floor type C2 (1:3:6) using 40mm graded stone aggregate, complete all as specified and directed
M&L 75mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/footpath, complete all as specified and directed
M&L for preparation of new surfaces and applying three coats of white wash on wall including cornices etc complete all as specified and directed
M&L preparing new surface on walls and applying two coats of cement based paint over one coat of primer on external walls, complete all as specified and directed
S&F framed work as in door or gates of angle or other section with gusset plates rails, braces etc. Complete, drilled for fixing of steel sheeting or other covering. Door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging, also fastening and fixing complete all as specified and directed
S&F 0.80mm thick mild steel plain black sheet in steel gates and similar works cut to size, holes, punched including round heade screws, clout nails or revets and fixed to steel framing with plain 40mm lap joints with reveted or welded seams, including bending or turning up etc, complete all as specified and directed
S&F Steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed.
S&F Sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 sqm in each pane 3mm thick complete all as specified and directed
M&L mild steel works as in framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes and similar works conforming to Fe-290, Gde-E165 etc complete all as specified and directed
M&L PCC (1:2:4) type B1 20mm grade aggregate as in padding, hold fasts/filling of chowkhats or similar work complete all as specified and directed
M&L preparing new surface of steel any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, complete all as specified and directed
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M-40 grade, complete all as specified and directed.
Forming square grooves in plaster n.exc 12mm deep and n exc 15mm on face complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, complete all as specified and directed
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
M&L 100mm thick mastic flooring in four layers as per IS 13026 1991 for LPG Store, complete all as specified and directed
S&F Pressure die cast aluminum alloy housing LED street light fitting 60 Watt comprises of pressure die cast Aluminium housing & having system efficiency 110 lumens/Watt i.e 6670 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree, Input voltage working range is 140 Vac to 270 Vac, Brand name should be emoboised, Potted Driver is used with 4KV internal & external 5KV Potted surge protection, Short Circuit Protection, Open Circuit Protection, High & low voltage protection, fixture should withstand high & low voltage protection, fixture should withstand high voltage upto 440 v for 8 hr, IP66 Protected, THD<10%,CRI>70CCT 5700+/-300K, PF>0.9, Driver efficiency>85%,LM79 report require from NABL Accediated lab complete all as specified and directed
Supply and fix in replacement post top lantern cast aluminium spigot, spun aluminium canopy with clear acrylic cover with 20 Watt LED lamp including all accessories such as Bracket, GI Pipe and prewired, complete all as specified and directed
Supply and fix 1.5 Sqmm, single core Two runs PVC insulated and unsheathed FR cable 1100 Volts grade with multistranded copper conductor and one run of 1.5 Sqmm cable for common earth dolly drawn through heavy duty PVC conduit for street light pole including connection from kiosk box to street light fittings, complete all as specified and directed.
Supply and fixing in replacement of street light cable junction box of size 155x155x100 mm with terminals fixing on pole with 25x4 mm aluminium strip clamp with nut, bolts and washer etc, complete all as specified and directed
Supply only MCB SP 06 to 32 Amp 10 KA, 'C' curve 230 Volt complete all as specified and directed
LT Panel Board of size 300x300x100mm with 4 bus bar of capacity 100 Amps incoming MCCB 63 Amps, complete all as specified and directed
M&L Steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 Meters long), complete all as specified and directed
Supply, laying, jointing, testing and commissioning XLPE insulated, armoured, heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 25 sqmm 4 core connected with aluminium lugs connected by cramping tools complete all as specified and directed Note : Excavation and earth work will be measured and paid separately.
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
M&L for trenchless boring under road crossings/foot paths by manual / Boring machine complete all as specified and directed
Supply and fix in replacement of 50 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc, complete all as specified and directed
M&L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 32 x 6 mm 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts & washers, testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part-I filling with charcoal dust and common salt, including necessary excavation and earth work in any type of soil, perforated watering pipeof size 15 mm dia, funnel with wire mesh, earth strip protection pipe light grade PCC chamber (1:3:6) type C1 (for even finish on both the faces) and RCC cover (1:2:4) Type B1, 450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc, complete all as specified and directed Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate.
S&F GI earth strip (32x6) mm strip with and including necessary clamps, nut bolts laid in ground complete all as specified and directed.
M/S SHAMBHU SHARAN SINGH
M/S KAMLESHWAR SINGH
M/s R R MUKHERJEE & CO
M/s Kundu Enterprises
M/S OMANIA ENTERPRISES
Balaji Construction And Company
ashiyana electrical company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .