Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
8 Jun 2020, 5:00 pmClosed
Raja Nagender Singh
XEN(E) Gurugram
Pdg. special repair to E.I. in boys hostel Govt. Polytechnic Manesar in Gurugram district.
2020_HRY_128405_1
Pdg. special repair to E.I. in boys hostel Govt.
Open Tender
Electrical Works
Works
90 days
XEN(E) Gurugram
Refer DNIT
3 documents required · 3 mandatory
₹1,000
Executive Engineer,Electrical Division
₹15,000
8 Apr 2021
14 May 2020
9 Jun 2020
14 May 2020
8 Jun 2020
14 May 2020
Amount
Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections.15 amp.to 60 amp. 415 V ,10 KA 3-phase.
100 amp.to 220 amp.415 V,10 KA 3-phase.
Supply and erection of blanking sheet in existing distribution board.
Supply and erection of miniature circuit breaker/ isolator 240/415 V in the existing distribution board including making necessary connection.Miniature circuit breakers of 9 KA breaking capacity.SP MCB of 6 amp. to 32 amp.
SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp.
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp.
Supply and erection of Fittings and Accessories.Call bell 220 / 230 volts A.C. bakelite with double coil.
Bakelite angle / straight button holder large size.
erection only of 1x40 watts or 2x40 watts 1220 mm long /1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
Extra for using salt and charcoal / coke for pipe earth electrode as required.
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required .
Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material.
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections,digging and refiling of trenches. 120 Sq. mm 3.5 Core Ard. Cable .
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections . 16 Sq. mm 2 Core Ard. Cable .
70 Sq. mm 3.5 Core Ard. Cable .
120 Sq. mm 3 Core Ard. Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. 120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core
Wiring in existing conduit pipe(Recessed) for electrical points.wiring only in 1.5 sq.mm PVC insulated copper conductor cable in existing conduit pipe and MS boxes covered with 5 mm thick bakelite sheet including cost of switch, wall socket, ceiling rose etc.Fan Point Medium Point .
Long Point .
Light point Short Point
Medium Point .
Long Point .
Twin control light point with 2 way 5 amp. single pole switchLong point.
Call bell pointLong point
3 pin 5 amp. plug point including earthing the 3rd. pin etc.Short point.
Long point.
3 pin 15 amp. plug point including earthing the 3rd. pin etc. with 4 sq mm PVC insulated copper conductor cable. Long point.
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe.Cable size 1.5 sq.mm(3/ 0.81 mm)
Cable size 4.0 sq.mm(7/ 0.85 mm)
Cable size 10.0 sq.mm(7/ 1.05 mm)
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work.4 way TP&N (Horizontal) (8 + 12)
8 way TP&N (Horizontal) (8 +24)
Supply and erection of M.S Saddles and clamps on wall/RCC parapit for fixing the under ground cable at a distance of .60 metre centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .