Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹30.4 L+₹77,273.12 (2.61%)Rejected-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹31.4 L+₹1.7 L (5.82%)Rejected-AOC 37 A 19 3 B MADHU NAGAR AGRA UP | AGRA | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹31.8 L+₹2.1 L (7.23%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 5 | L5₹33.2 L+₹3.5 L (11.9%)Rejected-AOC 19 SAINIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | MADHYA PRADESH | 462030 | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Amla
GE AF Amla, Betul Dist 460553 (MP)
Repair/Maintenance of LT Distribution system and connected works at AFS Amla
2023_MES_592589_1
8534/E8 of 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE (AF) Amla
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹60,000
Yes
24 Jul 2023
1 May 2023
29 May 2023
1 May 2023
27 May 2023
15 May 2023
Amount
Taking out carefully PVC insulated sheathed armoured stranded aluminium conductor LT underground cable from trenches/ ducts/ walls etc., including necessary dismantling, demolition and disconnecting cables from existing power line complete all as specified and as directed for the following sizes of cable:- Note :- (i) Earth work excavation, returning filling and disposal shall be measured & paid separately under respective items. (ii) The surface disturbed during dismantling/demolition shall be made good by contractor at his own cost by using 1:2:4 type B1 concrete (or) in CM 1:4 which deemed to be included in the contractor quoted rate.
25 to 70 Sqmm 3.5 Core
95 Sqmm 3.5 Core
Supply lay & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, laid in trenches/passing through pipe/duct or fixed to wall/pole etc., and connecting up complete all as specified and directed for the following size of cable:-
25 Sqmm 4 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
95 Sqmm 3.5 Core Notes for Item No 02. (i) The minor parts such as clamps, screw etc.,, required for fixing cables on wall, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate. (ii) Earth work excavation, returning filling and disposal, protection pipe & joint kit shall be measured & paid separately under respective items.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for laying cables and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0m in depth; for laying cables and getting out in hard/dense soil complete all as specified and directed.
Returning filling in excavated soil including spreading levelling and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed.
Supply and spread dry river washed sand free from foreign material in trenches for cable cushioning all as specified and directed. Note:- For payment purpose only punned thickness of sand will be measured & paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm all as specified and as directed.
Material and labour for Galvanised steel tubing, light grade laid in trenches/ fixed to poles, walls etc as a protection for service cable including removing existing old unserviceable rusted pipe complete all as specified and directed for the following size of pipe:- Make :- Jindal/Tata/Prakash Surya
50mm bore
80 mm bore Notes for item no 9.01 & 9.02:- (i) The minor parts such as clamps, screw etc.,, required for fixing pipe on wall, pole, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate.
Dismantling of old concrete pole/ strut, any size and disposing them away from defence land complete all as specified and directed.
M&L for providing horizontal bore hole of dia upto 120mm below road/hard standing surface for the length upto 10 Metre and inserting GI/PVC pipe into the bore hole as cable protection complete all as specified and as directed. Note:- Cable protection pipe shall be measured and paid separately under relevant item.
Supply & erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.50 metres long) including appllication of two coat of aluminium paint over one coat of red oxide zinc chrome primer above ground level and two coat of bituminous paint below ground level complete all as specified and directed.
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.
Material and labour for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.
Material and labour for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and the like including necessary form work etc, complete all as specified & directed.
Supply and fix in repair junction boxes of size 300mm x 450mm x 170mm with aluminium bus bar rating three phase 150 Amps and neutral 75 Amp, IP 65 having provision for metric knockouts for cable entry upto 70 Sqmm including GI clamps complete all as specified and directed. Make :- HENSEL (Cat No : K-7004) or any equivalent make as approved by GE.
Supply and fix in repair junction boxes of size 205x255x112mm with 4 terminal of rating 32 Amp, IP 65 having provision for metric knockouts for cable entry upto 25 Sqmm including GI clapms 30x4 mm thick, nuts, bolts & washers including two caots of aluminium paints on GI clamps complete all as specified and dirfected. Make :- HENSEL (Cat No : DK-2525G) or any other equivalent make as approved by GE.`
Supply and fix in repair out door type straight through joint heat shrinkable type for LT XLPE/PVC 1100 volt graded cable and connecting the cable including testing on load complete all as specified and directed for the following size of cables :-
LT cable size 3.5/04 x 25 to 50 Sqmm
LT cable size 3.5/04 x 70 to 120 Sqmm
Supply and fix in repairs MCCB 415 volts, 4 pole with thermal magnetic release of the following ratings :-
MCCB 630 Amps, 415 Volts, 4 Pole, Breaking capacity 50 KA.
MCCB 400 Amps, 415 Volts, 4 Pole, Breaking capacity 36 KA.
MCCB 250 Amps, 415 Volts, 4 Pole, Breaking capacity 36 KA
MCCB 200 Amp, 415 Volts, 4 Pole, Breaking capacity 25 KA
MCCB 160 Amps, 415 Volts, 4 Pole, Breaking capacity 16 KA
Taking down old u/s aluminium conductors and M&L for aluminium conductor steel reinforced for overhead line, fix on pole or for jumper connections, fixing to the insulator by means of necessary binding with 14 SWG wire all as specified.
M&L for painting of steel tubular poles 8.5/9.0 mtr with two coats of aluminium paint including painting to cross arms and clamps etc. including preparation of surfaces by scrubbing and cleaning with wire brush all as specified and directed.
Material and labour for marking of pole number with black luminous words on luminous yellow round sticker as per sample complete all as specified and directed.
Material and labour for stay assembly as shown in electrical plate No 1 of SSR part I comprising of 7/3.15 mm galvanised mild steel stranded stay wire of required length fixed to pole with and including FI clamps of size 50x6 mm, bolts, nuts, washers, stay rod of 20 mm dia 2.15 mtrs long, stay bow with nuts bolts washers, galvanised steel plate 230x230x6 mm including loop insulators over all dimensions 140 mm cleearance of hole 25.5 mm complete including taking down old unserviceable stay assembly all as specified and directed.
M&L for plate earthing with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 25 x 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipment’s etc at the other end including 32 mm GI light grade pipe with all fittings from top of electrode to body of equipment fixed with iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 3 of SSR Part-1 including testing earth resistance and submitting test report to AGE E/M by the contractor complete all as specified & directed. Note :- (i) Earthing resistance required in earthing shall less than 1.0 Ohms after completion of work. All earthing shall be tested by the contractor in presence of Engr-in-Charge. Test result shall be recorded and signed by the contractor and Engr – in- Charge. If contractor fail to achieve the above result the same shall be rectified by the contractor without any extra cost to Govt. The earthing result will be required maintaining up to end of defect liability period of one year and if any variation found in earthing result during defect liability period same will be intimated to the contractor by Engg-in-Charge and contractor shall rectify the same. The quoted rates shall be deemed to include for above said provision. (ii) Quoted rates shall be deemed to be included for earth strip with protection pipe up to 7.5 length.
Galvanised iron strip as earth continuity conductor or main earthing lead of size 25 x 4 mm.
Material and labour from cross arms, bracing, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes or bolts, in any shape or size including two coat of aluminium paint over one coat of red oxide paint complete all as specified and as directed.
Labour for cutting/trimming tree branches coming on overhead line LT/HT lines minimum 02 mtr space all round the conductor.
Supply and fix in repairs insulators pin type porcelain, vitreous, white, brown or green including one galvanised MS spindle two galvanised iron washers and one galvanised iron nut 100 mm height 65 mm dia for 1100 volts grade all as specified and directed. Make :- Jaipuria brothers or make approved by GE.
Restraining and stretching of OH line of ACSR conductor of any size including cleaning of insulators and aluminium wire for binding all as directed as following :-
3 phase 3 wire system measured as single run
3 phase 4 wire system measured as single run.
Single phase 2 wire system measured as single run.
Dismantling unserviceable line separators and supply and fix line separators for OH line PVC insulated and PVC nut and bolt hook up/spriral suitable for :-
Single phase 2 wire system measured as single run.
3 phase 4 wire system measured as single run.
Supply, fixing & connecting in repair of PVC insulated twin core 2.5 Sqmm unsheathed multistranded Al conductor complete all as specified.
Supply and fix in repair on pole/wall PVC conduit super quality size 20 mm dia complete all as specified & directed by Engineer-in-Charge.
Taking down, supply and install in repair LT Panel (CPRI approved) 440V AC, outdoor type 3.15 mm CRCA sheet of appropriate size, front double doors, front & back openable dut & vermin proof aluminium main bus bar of 600 Amps 03 Nos alongwith one Neutral bus bar 300 Amps, lifting arrangement/hooks at the tope, wiring with appropriate size of copper cables, MS anngle iron frame size 75x75x6MM thick cable glands brass chromium plated of different sizes suitable for outgoing LT cables complete with following specified items :-
INCOMER (a) MCCB 400 Amps, 4 pole fixed type , breaking capacity 35 KA, microprocessor based release with overload/short circuits and earth fault protection - 01 No (Incomming). (b) Spreader Terminal - 01 No (c) Rotary Handle - 01 No (d) R/Y/B Indication - 03 Nos (e) Digital Ammeter - 01 Nos (f) Digital Volt meter 0-500 Volts - 01 Nos (g) CTs 400/5A - 03 Nos (h) Control 6A SP MCB - 06 Nos (j) Fuse base with link - 03 Nos (k) Surge protection device maximum continuous operating voltage 275 volts short circuit withstand (icc) 35 KA, model No CSH1 50/230(L-N). Make - Mc Layers/Rashan Engineering or equivalent. - 01 Nos
OUTGOING (a) MCCB 160 Amps 04 Poles, breaking capacity 16 KA with thermal magnetic release with over load/short cicuit protection. - 02 Nos (b) Spreader terminals - 02 Nos (c) MCCB 63 Amps 04 Poles, breaking capacity 16 KA with thermal magnetic release with overload/short circuits protection. - 03 Nos (d) Spreader terminals - 03 Nos (e) Rotary Handle - 05 Nos
Taking down, supply and install in repair LT Panel (CPRI approved) 440V AC, outdoor type 3.15 mm CRCA sheet of appropriate size, front double doors, front & back openable dut & vermin proof aluminium main bus bar of 600 Amps 03 Nos alongwith one Neutral bus bar 300 Amps, lifting arrangement/hooks at the tope, wiring with appropriate size of copper cables, MS anngle iron frame size 75x75x6MM thick cable glands brass chromium plated of different sizes suitable for outgoing LT cables complete with following specified items :-
INCOMER (a) MCCB 350 Amps, 4 pole fixed type , breaking capacity 35 KA, microprocessor based release with overload/short circuits and earth fault protection - 01 No (Incomming). (b) Spreader Terminal - 01 No (c) Rotary Handle - 01 No (d) R/Y/B Indication - 03 Nos (e) Digital Ammeter - 01 Nos (f) Digital Volt meter 0-500 Volts - 01 Nos (g) CTs 350/5A - 03 Nos (h) Control 6A SP MCB - 06 Nos (j) Fuse base with link - 03 Nos (k) Surge protection device maximum continuous operating voltage 275 volts short circuit withstand (icc) 35 KA, model No CSH1 50/230(L-N). Make - Mc Layers/Rashan Engineering or equivalent. - 01 Nos
OUTGOING (a) MCCB 100 Amps 04 Poles, breaking capacity 16 KA with thermal magnetic release with over load/short cicuit protection. - 02 Nos (b) Spreader terminals - 02 Nos (c) MCCB 63 Amps 04 Poles, breaking capacity 16 KA with thermal magnetic release with overload/short circuits protection. - 03 Nos (d) Spreader terminals - 03 Nos (e) Rotary Handle - 05 Nos
Taking down, supply and install in repair LT Panel (CPRI approved) 440V AC, outdoor type 3.15 mm CRCA sheet of appropriate size, front double doors, front & back openable dut & vermin proof aluminium main bus bar of 600 Amps 03 Nos alongwith one Neutral bus bar 300 Amps, lifting arrangement/hooks at the tope, wiring with appropriate size of copper cables, MS anngle iron frame size 75x75x6MM thick cable glands brass chromium plated of different sizes suitable for outgoing LT cables complete with following specified items :-
INCOMER (a) MCCB 250 Amps, 4 pole fixed type , breaking capacity 35 KA, microprocessor based release with overload/short circuits and earth fault protection - 01 No (Incomming). (b) Spreader Terminal - 01 No (c) Rotary Handle - 01 No (d) R/Y/B Indication - 03 Nos (e) Digital Ammeter - 01 Nos (f) Digital Volt meter 0-500 Volts - 01 Nos (g) CTs 350/5A - 03 Nos (h) Control 6A SP MCB - 06 Nos (j) Fuse base with link - 03 Nos (k) Surge protection device maximum continuous operating voltage 275 volts short circuit withstand (icc) 35 KA, model No CSH1 50/230(L-N). Make - Mc Layers/Rashan Engineering or equivalent. - 01 Nos
OUTGOING (a) MCCB 100 Amps 04 Poles, breaking capacity 16 KA with thermal magnetic release with over load/short cicuit protection. - 01 Nos (b) Spreader terminals - 02 Nos (c) MCCB 63 Amps 04 Poles, breaking capacity 16 KA with thermal magnetic release with overload/short circuits protection. - 03 Nos (d) Spreader terminals - 03 Nos (e) Rotary Handle - 04 Nos
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Paragon Electrotechnics
M/S J J ENTERPRISES
Vee kay construction
SUNIL ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .