Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-Finance | L1 | Accepted-Finance Lowest Rate | |
| 2 | L2₹9.3 L+₹37,830 (4.24%)Rejected-Finance D BLOCK MUNSHI PULIYA NEAR PNB BANK OLD PICNIC SPOT ROAD INDIRA NAGAR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-Finance Higher Rate |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
2 Apr 2022, 11:00 amClosed
Superintending Engineer
Superintending Engineer, U.P.State construction and Infrastructure Development Corporation Ltd., Lekhraj Market-1st, IIIrd floor Indira Nagar Lucknow
Labour Charges for Internal Electrification work of Auditorium Building of U.P. Sanskrit Sansthan New Hydrabad,Lucknow.(Balance work)
2022_SCIDC_681553_1
544/E.E./E-TENDER/2021-22
Open Tender
Electrical Works
Item Rate
90 days
Lucknow
Labour Charges for Internal Electrification work of Auditorium Building of U.P. Sanskrit Sansthan New Hydrabad,Lucknow.(Balance work)
2 documents required · 2 mandatory
₹780
UPSCIDCo.ltd.
₹18,000
7 Apr 2022
25 Mar 2022
2 Apr 2022
25 Mar 2022
2 Apr 2022
25 Mar 2022
Amount
Labour Charges For Internal Electrification For Electrical & A.C. Work
Labour Charges for Fixing of submains with two number 6 sq.mm FRLSH PVC insulated 1100 Volt grade multistrand single core copper conductor cable in 25 mm dia heavy duty (2 mm thick) PVC conduit with one no. 4 sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. complete in all respect.
Labour Charges for Fixing of submains with 4 number 6 sq.mm FRLSH PVC insulated 1100 Volt grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2 mm thick) PVC conduit with 2 nos. 4 sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. complete in all respect.
Labour Charges for Fixing of single light wall bracket on matching M.D.F.E.G. Board base.
Labour Charges for Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 6 sq.mm x 2 core.
16 sq.mm x 2 core.
16 sq.mm x 4 core.
35 sqmm x 3½ core.
120 sq.mm x 3½ core.
400 sq.mm x 3½ core.
Labour Charges for Fixing of 7 mtr. G.I. octagonal pole of (top dia 70 mm, bottom dia 130 mm & base plate 12 mm thik) having 3 mm thikness with single arms bracket(1 mtr. Length) complete in all respect with making of RCC foundation as per PWD Norms.
Labour Charges for Fixing of 32 mm x 6 mm G.I. Strip from earth electrode directly in the ground as required complete in all respect.
Labour Charges for burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50 mm, inner Dia 25, terminal Dia 12 mm, outer G.I. pipe of 16 swg and inner G.I. pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25 mm x 3mm G.I. strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Labour Charges for Fixing of factory fabricated and wired metal clad dust and vermin proof floor mounting M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN ACB (65 KA, 4 pole Elect. deaw out, Micor processer Release IPR2) and TPN MCCB's (Four pole 36 KA with thermal magnatic release) switches complete with cable gland, Lugs PVC tape nut bolt etc.complete in all respects. Outdoor Type .Incoming - 1250 Amp ACB = 1 No. Outgoing - 630 Amp MCCB = 2 Nos. 400 Amp MCCB = 1 No.
Labour Charges for Fixing of factory fabricated and wired metal clad dust and vermin proof floor mounting M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four pole 36 KA with thermal magnatic release) switches complete with cable gland, Lugs PVC tape nut bolt etc.complete in all respects. Outdoor TypeIncoming - 630 Amp MCCB = 1 No. Outgoing - 200 Amp MCCB = 1 No. 100 Amp MCCB = 5 Nos
Incoming - 630 Amp MCCB = 1 No. Outgoing - 200 Amp MCCB = 4 Nos.
Incoming - 200 Amp MCCB = 1 No. Outgoing - 63 Amp MCCB = 4 Nos.
Labour Charges for Erection and testing of ceiling/Wall Fan and regulator etc. complete in all respect.
Labour Charges for Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts, nuts and washers etc. complete in all respect.
Labour Charges for Fixing of Fire extinguisher, ABC Type 6.00 Kg. capacity (ISI marked IS: 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Labour Charges for Fixing of Co2 type Fire extinguisher, 4.5 Kg. capacity (ISI marked IS: 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Labour Charges for Fixing of fire bucket, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chined and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.
Labour Charges for Fixing of shock treatment chart (Prescribed under I.E Rule) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work.
Labour Charges for Fixing of 1800 mm x 900 mm x 12 mm thick chequered rubber matting of tested quality.
Labour Charges for Fixing of Power plug with 20A/250 volt flush type modular switch and 5 pin 20A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for completion of work.
Labour Charges for Laying of submain with two number 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit with 1 nos. 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduite complete in all respect including matching colour wash.
Labour Charges for Fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.
Labour Charges for Fixing of recess/Surface/Pendent mounting round 10 watt to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Cat AAA
Labour Charges for Fixing of recess mounting round 15 watt to 18 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respect. Cat AAA
Labour Charges for Fixing of 36 watt to 46 watt indoor recess mounting LED Square Fitting with support of Hanging system.
Labour Charges for Fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 1 x 22 watt suitable for upto 1 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect.
Labour Charges for Fixing of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 watt. Confirming to IP 66 and above Protection complete in all respect. Cat-AAA on G.I. pole.
Labour Charges for Fixing of decorative 40 to 45 watt LED Post top indirect light luminaire having Pressure die cast aluminium body and clear glass with driver set confirming to IP 65 and above protection complete in all respect. Cat-AAA on Gate.
Labour Charges for Fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 170 to 200 watt. Confirming to IP 66 protection complete in all respect. Cat AAA on G.I. pole.
Labour Charges for Fixing of Mirror Light
Labour Charges for Fixing of Fan Sheet of Backelite
Labour Charges for Fixing of LED Bulb 9/12 watt ISI
Labour Charges for Fixing of 63 mm dia x 3.0 Mtr. long G.I. pole with foundation.
Labour Charges for Fixing of G.I. wire 8 SWG.
Labour Charges for Fixing of exhaust fan luvers 12”dia
Labour Charges for Fixing of factory fabricated and wired metal clad dust and vermin proof floor mounting M.S. Channel Base with bottom and top cable entreis Electrical control panel with making of required foundation. Incoming – 63 Amp MC CB = 1 No. Outgoing – 40 Amp DPMCB = 6 Nos.
Labour Charges For Wiring for 2 Nos. Lift
Labour Charges For Wiring point for light with 1.5 Sq. mm FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire drawn inside. continuity wire, Modular type switch & ceiling rose/angle/ batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect. with Modular Box & Cover plate.
Labour Charges For Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit, Modular type switch & ceiling rose on 3 mm. thick backelite sheet etc. complete in all respect with Modular Box & Cover plate.
Labour Charges For Wiring point for plug with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit, Modular type switch & socket etc. complete in all respect with Modular Box & Cover plate.
Labour Charges For submains with two number 4 sq.mm FRLSH PVC insulated 1100 Volt grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit with one no. 2.5 sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. complete in all respect.
Labour Charges For Fixing of 63 Amp 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect. Cat-B
Labour Charges For Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.35 sqmm x 3½ core.
Labour Charges For Laying of 25 mm x 3 mm G.I. Strip from earth electrode directly in the ground as required complete in all respect.
Labour Charges For Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50 mm, inner Dia 25, terminal Dia 12 mm, outer G.I. pipe of 16 swg and inner G.I. pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25 mm x 3mm G.I. strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Labour Charges For Fixing of 6 Amp. To 32 Amp. SPMCB (10 KA) Cat-B
Labour Charges For Fixing of 63 Amp. DP MCB (10 KA) Cat.-B
Labour Charges For Fixing of surface/flush mounting 12 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. Cat-B
Labour Charges For Fixing of Power plug with 20A/250 volt flush type modular switch and 5 pin 20A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for completion of work.
Labour Charges For Fixing of hexagonal/Round G.P. fan box of approved make made up 1.0 mm thick ISI Marked G.P. sheet spot welded four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S. bar x 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting along with supply of all material, labour, T&P etc. required for proper completion of work.
Supply and wiring of submain with two number 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit with 1 nos. 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduite complete in all respect including matching colour wash.
Labour Charges For Fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 1 x 22 watt suitable for upto 1 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect. 2420 system lumens, 1101m/watt, PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Tube with aluminium heat sink 5 year warrantee Cat AAA
Labour Charges For Fixing of water tight oblong bulkhead Fitting ordirnary
Labour Charges For Fixing of LED Bulb 12 watt ISI
Labour Charges For Fixing of 5 Amp Plug & Switch with Modular box, sheet etc.
Labour Charges For Fixing of light duites exhaust fan 12" dia Bajaj / Usha / Cromption make.
Labour Charges For Fixing of exhaust fan luvers 12”dia or 18"dia
Labour Charges For Fixing of Wall Fan 16" Usha / Crompton/Bajaj make
Labour Charges For Lighting Arrester
Labour Charges For Fixing of horizontal air termination (roof conductor) of 25 mm x 3 mm G.I. Strip G.I. clamp on surface.
Labour Charges For Fixing of vertical air termination final rod comprising of 300 mm long x 25 mm dia. Copper rod with G.I. material etc. complete in all respect.
Labour Charges For Fixing of vertical down conductor of 32 mm x 6 mm G.I. strip etc. on approved clamps on surface for lightning conductor.
Labour Charges For burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000 mm, Outer pipe 76 mm inner Dia 38 mm, terminal Dia 12 mm, outer G.I. pipe of 16 swg and inner G.I. pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing.
G.S.T. Will be paid extra as applicable.
SANJAY ELECTRIC COMPANY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .