Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹34.5 L+₹1.0 L (3.01%)Rejected-Finance AT VINDHANE POST DIGHODE TAL PANVEL DIST RAIGAD | RAIGAD | MAHARASHTRA | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹35.2 L+₹1.7 L (5.13%)Rejected-Finance | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹37.7 L+₹4.2 L (12.5%)Rejected-Finance | L4 | Rejected-Finance HIGHER | |
| 5 | L5₹40.0 L+₹6.5 L (19.3%)Rejected-Finance | L5 | Rejected-Finance HIGHER |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
21 Nov 2022, 6:00 pmClosed
GE Amritsar
GE Amritsar Pin 143001
SPECIAL REPAIR TO BUILDING NO P-26 FAMILY WARD AT MH, BUILDING NO P/41C OF MDC AND BATHROOM AND TOILETS OF OTM ACCN BUILDING NO DD-5 AND DD-6 AT OLD AMRITSAR CANTT
2022_MES_555458_2
GE/ASR-55/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE Amritsar
Class D Category a i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹96,000
28 Oct 2024
1 Nov 2022
22 Nov 2022
1 Nov 2022
21 Nov 2022
8 Nov 2022
Amount
Taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water etc ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:6 finishing even and smooth without using extra cement ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4 finishing even and smooth without using extra cement ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in CM 1:3 finishing even and smooth without using extra cement ; Complete all as specified and as directed by Engineer-in-Charge.
Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc. ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:4 ; Complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No 6 above but except bricks (old dismantled serviceable bricks obtained from Srl item No 5 shall be reused after necessary cleaning of mortar).
Material and Labour for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, in half brick thick walls and built in CM 1:4 ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for applying two coats of whitewash on wall including preperation of newly plastered surfaces ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for applying one coat of whitewash on wall including preperation of old decorated surfaces ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for applying two coats of whitewash on ceiling including preperation of newly plastered surfaces ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour preparation of newly plastered surface of wall and applying two coats cement base paint over a coat of primer to match the existing treatment ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour preparation of old decorated surfaces of wall and applying one coat cement base paint ; Complete all as specified and as directed by Engineer-in-Charge.
Taking down Chowkats or frames from the opening of size not exceeding 1.5 sqm each with shutters ( without taking off shutters from the frames) ; Complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No 14 above but size of opening exceeding 1.5 Sqmtr but not exceeding 4 Sqmtr
Material and Labour for Box type steel window made of ERW tube P- section of size 60 mm x 25 mm double rebated outer frame, comprises glazed skelton & gauzed shutter of ERW tube P-Section size 50mm x 20mm with one/two Nos openable leaf for each shutter consisting of two Nos Sashbar of T-section 20 x 3 mm welded to frame with one No verticle mullion of ERW box type T Section of size 60mm x 25mm and FI 2mm thick welded/screwed to frame for fixing of glass including fittings and fixture like as Handle, Tower Bolt, Stopper, Cleat, Pintal hinges, holdfast etc as given below all as shown on drg No CEJZ/TD-1020/08 Sh 1/3 to 3/3 dt 01 May 2008 ; Complete all as specified and as directed by Engineer-in-Charge. (a) Hold fast 150mm long of 12mm x 3mm MS flat - 4 Nos per Window.(b) Handle of Z section 20mm x 25mm, 100mm long- 01 No per leaf.(c) MS tower bolt 150mm long - 02 Nos/leaf.(d) Z Section stopper 20mm x 25mm, 100mm long - 01 No per leaf.(e) Cleat 55mm long of hollow square 15mmx12mm - 02 Nos per leaf.(f) MS pintol hinges size 75mmx12mm - 2 Nos per leaf Note :- Sheet glass, wire mesh and painting shall be measured and paid sperately.
Material and Labour for Box type steel ventilator made of ERW tube P-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and FI 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as Stopper, Cleat, Pintal hinges, holdfast etc all as shown on drg No CEJZ/TD1019/08 sheet 1/3 to 3/3 dt 01 May 2008 ; Complete all as specified and as directed by Engineer-in-Charge. NOTE:-Sheet glass and painting shall be measured and paid Separately.
Supply and Fixing pressed steel frames 1.25mm thick for door size of frame 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate and tarring to inner surface (surface in contact with concrete/brick surface) of chowkats and hinges ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) in bed blocks for hold fast & similar work etc ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Solid PVC Door Frame of Size 50mm x 47mm made out of 5mm plain colour PVC Sheet reinforced with MS Square tube in opening as per specification and drawing ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing 27 to 30 mm thick (Rajshri brand) factory made solid PVC moulded Door shutter(With wood free EPS) with 2,3 or 6 raised panel design with 2mm thick moulded PVC Sheet on the front face and 2mm plain colour PVC Sheet on back face, fixing in frame at site as per specification and drawing ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing framed work as door, chowkhats, and Grill gates of angle frame work fixed with Nut & bolt to wall or other section complete drilling or fixing welding be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also festering and fixing ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for two coats of synthetic enamel painting on steel surfaces of any description over 10 cm in width or girth not otherwise described above priming coat of red oxide including prepration of previously untreated surfaces ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for one coat of synthetic enamel painting on steel surfaces of any description over 10 cm in width or girth not otherwise described including prepration of previously untreated surfaces ; Complete all as specified and as directed by Engineer-in-Charge.
Labour for Hacking out old broken glass panes of any thickness description from wooden frame or stone concrete or steel frame,or brick surrounds, glazed with putty or fixed with beads and prepared to receive new glas panes ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or with flat iron ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or with flat iron ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing clear glass, 3mm thick ordinary quality, in any shape, not exceeding 0.50 sqm in each pane including and glazing with oil putty ; Complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No 28 above but figured glass pin head type & glazing with oil putty.
Supply and Fixing 300mm long Aluminium alloy, Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Aluminium, anodised, barrel tower bolts 150mm of extruded section and fixed ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing 150mm long Aluminium handles, cast type anodised ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing stainless steel butt Hinges, 100mm size, medium weight, cold rolled mild steel ; Complete all as specified and as directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing non skid ceramic light coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing glazed ceramic coloured tiles 450x300mmx6mm thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in CM 1:4 on brick surface ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repair vitreous China Squatting pan 'Orrisa' pattren size 580x440mm white with integral foot rest and PVC(SWR) 'P' trap 110/110mm bore ; Complete all as specified and as directed by Engineer-in-Charge. Note:-Rate of supply for Flushing cistern, flush pipe, seat cover etc have been taken separately.
Supply and Fixing of Vitreous china wash down water closet pan( pedestal pattern), white ; Complete all as specified and as directed by Engineer-in-Charge. Note:-Rate of supply for Flushing cistern, flush pipe, seat cover etc have been taken separately.
Supply and Fixing in repair 10 Ltr capacity PVC valveless symphonic action type flushing cistern white low level with ball valve flote handle including bracket and flush pipe of polythylene of low or high density or PVC,32mm dia ; Complete all as specified and as directed by Engineer-in-Charge.
Supply only Plastic water closet seat,white/ivory,closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (Toilet Seat Cover) ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repairs PVC Jet spray suitable for EWC ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repairs vitreous China wash basin white,flat back size550x400mm including PTMT waste coupling 32mm bore,waste PVC pipe complete, CP brass Pillar Tap 15mm bore ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repairs glass shelve assembly 60cm in oval shape consisting 5.5mm to 8mm thick glass including CP guard railing with double rail ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing PVC connection 15mm size with PTMT nuts of length 600mm ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing vitreous china urinal half stall type with CP spreader white incl CP waste coupling with grating and union fordischarge pipe, including providing and fixing plug, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement fixing with brackets, flush pipe, grating and union for discharge pipe ; Complete all as specified and as directed by Engineer-in-Charge.
Dismantling water tanks and Supply & Fixing rotational moulded polythene water storage tanks of 1000 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-1 including Ball valves high pressure PTMT with epoxy coated Aluminium rod & High density plastic ball screwed for iron pipe and fixed to GI pipe of 20mm bore ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing 15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing 20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repair 15mm bore Concealed type stop cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repair 15mm bore type angle cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repair of brass cromium brass plated fancy type bib taps 15 mm bore long nose screwed down screwed for iron pipe or for brass ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing PVC waste pipe32mm dia fixed to WHB/Urinals ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repairs 100mm dia CP grating with or without hole type ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repairs CP brass towel rail of 20mm dia and 600mm long ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in repairs 125mm CP shower rose fancy type with CP arm ; Complete all as specified and as directed by Engineer-in-Charge.
Taking down eaves gutters and rain water pipes ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc., including cleaning or refixing or removal to store , measured overall as fixed along the centre line over fittings and accessories ; Complete all as specified and as directed by Engineer-in-Charge.
Dismantling of cast iron drain pipes of 75mm/100mm bore, jointed in cement mortar and taking out of trenches or from walls, if required ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing 110mm bore PVC(SWR) pipes single socketed in any length fixed to walls with dash true nut and bolt at every 2mtr length including) including all fittings ; Complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No 59 above but laid in trenches.
Supply and Fixing 75mm bore PVC(SWR) pipes single socketed in any length fixed to walls with dash true nut and bolt at every 2mtr length including) including all fittings ; Complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No 61 above but laid in trenches.
Supply and Fixing 110mm PVC (SWR) bends any radius with access door ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing 75mm PVC (SWR) bends any radius with access door ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing 75mm PVC floor trap ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for RCC 1:1/1/2:3 type B0 (using 12.50 mm graded stone aggregate) for repairs of Chajjas, Fins, fascias and Parapets etc including necessary form work upto ( average thickness 50mm), scaffoldings , applying two coats of finishes to match with existing surfaces including demolition of existing RCC work ; Complete all as specified and as directed by Engineer-in-Charge.
Dismantling Brick tiles or terracing tiles, single layer on roofs ; Complete all as specified and as directed by Engineer-in-Charge.
Demolition mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in padding concrete fair finish avg 50mm thick, roof kerbs or mud stops, rounded or chamfered on edges and like including weathering slight rounded and throating ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces etc ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing (minimum) 3mm thick APP film based poly meric membrance minimum weighing 3Kg per Sqm reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application over entire roof area with over lapping 100mm to either sides and sealed in after cleaning down the roof by brooms ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 40mm thick brick tiles, laid on and including 15 mm thick cement mortar 1:6 and joints grouted and pointed flush in CM 1:3 mixed with 5% crude oil by weight of cement ; Complete all as specified and as directed by Engineer-in-Charge.
All as per Srl Item No. 72 here-in-before but except brick tiles. Note:-Old serviceable tiles shall be reused.
Demolition of cement Concrete in sunken floors exc 15cm thick ( above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4 with water proofing compound @2% weight of cement and, finishing even and smooth without using extra cement ; Complete all as specified and as directed by Engineer-in-Charge.(WPC shall be measured and paid separatly).
Supply only integral water proofing compound.
Material and Labour for Cement concrete 1:7:12 type F-2 (using 40mm graded brick aggregates) as in foundations, filling and mass concrete ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregates) as in sunken portion ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for cleaning of dust & dirt , Removal of all loose existing bituminous material or with chipper & applying heat torch gun to get smooth plain finished surface. Repair all joints & cracks with Highly Elastic bituminous Cold applied Putty-Tarplast- having penetration after setting upto 8mm & confirming to IS 1580:1991. Any annular space between drain pipe and concrete should be filled with mortar admixed with Shali SBR latex of STP Ltd. Making necessary Gola 75x75 mm with rich cement mortar admixed with ShaliSBR latex of STP Ltd at the interface of horizontal & Vertical junctions ; Complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness ( below or above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 50mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate as in plinth protection Finishing fair and even ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing 40mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for three coats of white wash on plaster surface of ceiling including prepration of surface ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for applying two coats of weather proof exterior emulsion paint of shade as approved by on walls over and including one coat of cement primer after preparation of surfaces ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for applying average 1 mm thick wall putty after complete removal of existing treatment on wall, ceiling, on old decorated surfaces or newly plastered surfaces ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour preparation of newly plastered surface of wall and applying two coats of oil bound distemper with necessary putty filling ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing powder coated aluminium frame for doors ,windows, ventilators with one or more rebates including joining cleats for fixing complete all as specified and directed by Engineer-In-Charge.( Min. thickness of powder coating 50 micron)
Supply and Fixing aluminum anodized powder coated door with member of shutter size 100x40mm for vertical style and TOP rail, lock rail 150x40mm and bottom rail 200x40mm with one rebates including anodized snap beading, rubber, bush and packing aluminum hard ware such handle 200mm, mortice lock, hinges, tower bolt 200mm aluminium and 5.00 mm thick Frosted glass (the thickness of all members of aluminium not less than 1.5 mm and hydraulic floor door spring double action regulated with stainless steel cover governing point hinges of bars heavy duty and mortice lock 4 levers ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing aluminium powder coated shutter (for window ) withn style top and botton rail kof section 44 x 44mm of 14 guage thick side hung type without sashbar including 5mm thick glass panes with 50 micron thick black sheet and necessary jointing cleats rubber beading aluminium anodised snap beading screws aluminium anodised fitting such as peg stay 150mm long but hinges 100mm, tower bolt 10mm and handle etc ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 140mm ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing door closer hydraulically regulated, (Alminium die cast body) designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing extruded Aluminium alloy handles fabricated type size 125mm ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing 25mm dia stainless steel Curtain rods/ rails, with brackets, stops, rollers, finials, 1 pair of decorative knobs for each curtain rod.including taking down ; Complete all as specified and as directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust , etc. and Brushing neat cement slurry with 3.0 Kg of cement per Sqm ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour, For priming the concrete surface with tarfelt LM or equivalent make approved by GE mixed with portable water in ratio of 1:1 and apply @400 qms per sqm (As per surface condition). Apply fist coat of tarfelt LM or equivalent make approved by GE having elongation 200% confirming to ASTM-C-412 & having crack bridging of 8 mm confirming to ASTM-c-836 with tensile strength after 7 day 0.50mm confirming to ASTM-C-412 with no lay geotex of 45 GSM/fibe mesh simultaneously and paste it properly with overlap of 50mm.Allow the fist coat to dry for 10 to 12 Hrs.Apply second coat cured fist coat with consumption @700 gms etc ; Complete all as specified and as directed by Engineer-in-Charge.
Labour for Filling in floors using surplus excavated soil Spreading and levelling in layers n exc. 25 cm thick and rammed including watering ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface in broken boulder ; Complete all as specified and as directed by Engineer-in-Charge.
Dismantling RCC purlins in suspended works ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for RCC 1:2:4 using 20 mm graded stone aggregates as in lintel beams ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for reinforced Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in chajjas, facia and the like ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Mild steel TMT bars 5mm to 8mm dia as strips, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Fair finished flat Form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports etc ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Fair finished flat Form work to chajjas and similar items including edges ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 75mm thick Cement concrete type D-2 , 1:4:8 (40 mm graded aggregate) as in sub base of floor. ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Machine pressed coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigments over and including 25mm thick sand cushioning ; Complete all as specified and as directed by Engineer-in-Charge.
Dismantling boarding , any description , fixed in any position with screws ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing GI frame work for seameless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws as 450mm centre to centr/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre and Material and Labour for Non asbestos fibre cement boards 6 mm thick in false ceilingi n ceiling fixed with screw as per manufacturers instructions including preparation of new surfaces & applying two coat of OBD on ceiling over chalk whitening with and including GI hangers of 6mm dia (upto 1.2m length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hpld fasteners 12.5mm dia 40mm long ; Complete all as specified and as directed by Engineer-in-Charge.
Dismantling Asbestos cement ( corrugated, semicorrugated ,etc.) sheets in roof coverings ; Complete all as specified and as directed by Engineer-in-Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing mild steel Gde Fe-410-W as in roof trusses,post , (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee,angle,channel, hollow tube or flat sections) including distance pieces , cleats etc including welding of joint ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour Cement concrete type C-2, 1:3:6 using 40mm graded agregate as in foundations, filling and mass concrete complete ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Excavating in post holes( or similar holes) in soft/loose soil each n exc 0.5 cu.m. getting out and removing surplus soil to a distance n.exc 50 m and making good surface ; Complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5m wide and n exc 1.5 m depth; for foundation, etc. or for shafts, wells, cesspits, manholes,pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/ loose soil ; Complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for removing exc soil material not exceeding 100 m and depositing where directed at at level not exc 1.5mt above the starting point ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for plain cement concrete( 1:3:6) type C-2 using 40mm graded stone aggregate as in surface channel and drains ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for sub class B bricks (old size) laid on edge on floor straight or curved on plan exceeding . 6 metre radius bedded and jointed in CM 1:6 and pointed in CM 1:3 ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for flush pointing to brick wall of drains in CM (1:3) ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Extra for forming fair finised drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds mitred/stopped ends etc ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for applying two coats of white wash on wall including preperation of newly plastered surfaces ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Cement concrete (1:2:4), type B-0 using 12.5mm graded stone aggregate as in benching, kerbs, mud stop, rounded or chamfered on edges including form work ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping orizontal face of groove with cement mortar 1:3 ; Complete all as specified and as directed by Engineer-in-Charge.
Dismantling water tanks Exc 250 Ltr & not exceeding 500Ltr and Supply and Fixing rotational moulded polythene, triple layers, water storage tank 500 Ltr capacity, closed top, cylindrical, hoisted and fixed in position including Supply and Fixing 20mm bore PTMT ball valve epoxy coated minium weight 210gms with aluminium rod ; Complete all as specified and as directed by Engineer-in-Charge.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc ; Complete all as specified and as directed by Engineer-in-Charge.
Taking up or down existing steel water tubing, 15mm bore alongwith connections fixed/laid in any situation, ; Complete all as specified and as directed by Engineer-in-Charge.
Taking up or down existing steel water tubing, 20mm bore alongwith connections fixed/laid in any situation, ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Galvanised iron steel water tubing, 15mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Galvanised iron steel water tubing, 20mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors ; Complete all as specified and as directed by Engineer-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc ; Complete all as Specified and as directed by Engineer-in-Charge.
Material and Labour for Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded, copper conductor in and including non-metalic PVC conduit incl accessories totally concealed in wall, ceiling/roof etc., with modular metal flush boxes of suitable size & modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade, multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as Specified and as directed by Engineer-in-Charge. (a) One light point/Fan point controlled by one switch NOTE: Cost of modular metal flush boxes with a coat of synthetic enamel paint over a coat of red oxide to steel surface to avoid rust, concealed in wall with suitable white cover plate for mounting switch/sockets, regulator, bell push etc and Cost of cutting chases & making good to distrubed surface with cement mortar, if required any shall be deemed to be included in the quoted rate (a) One light point/Fan point controlled by one switch
Material and Labour for Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded, copper conductor in and including non-metalic PVC conduit incl accessories totally concealed in wall, ceiling/roof etc., with modular metal flush boxes of suitable size & modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade, multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as Specified and as directed by Engineer-in-Charge. (a) One 5 Amps outlet point on same board with other switches/sockets NOTE: Cost of modular metal flush boxes with a coat of synthetic enamel paint over a coat of red oxide to steel surface to avoid rust, concealed in wall with suitable white cover plate for mounting switch/sockets, regulator, bell push etc and Cost of cutting chases & making good to distrubed surface with cement mortar, if required any shall be deemed to be included in the quoted rate
Material and Labour for Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded, copper conductor in and including non-metalic PVC conduit incl accessories totally concealed in wall, ceiling/roof etc., with modular metal flush boxes of suitable size & modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade, multistranded single core green colour copper conductor for earth continuity connected to earth dolly all as directed (a) One 3 pin 5 Amps socket outlet on independent board. NOTE: Cost of modular metal flush boxes with a coat of synthetic enamel paint over a coat of red oxide to steel surface to avoid rust, concealed in wall with suitable white cover plate for mounting switch/sockets, regulator, bell push etc and Cost of cutting chases & making good to distrubed surface with cement mortar, if required any shall be deemed to be included in the quoted rate
Material and Labour for Point wiring complete with 4.0 sqmm FRLS cable single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded, copper conductor in and including non-metalic PVC conduit incl accessories totally concealed in wall, ceiling/roof etc., with modular metal flush boxes of suitable size & modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 4.0 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade, multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as Specified and as directed by Engineer-in-Charge. (a) one 3 pin socket outlet,15 Amps on independent board. NOTE: Cost of modular metal flush boxes with a coat of synthetic enamel paint over a coat of red oxide to steel surface to avoid rust, concealed in wall with suitable white cover plate for mounting switch/sockets, regulator, bell push etc and Cost of cutting chases & making good to distrubed surface with cement mortar, if required any shall be deemed to be included in the quoted rate
Supply and fix switch piano one way 5 A, SP, 230 Volts ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and fix Socket outlet 2 in 1, 3 pin 5 Amps Flush type ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and fix Switch outlet 2 in 1, 3 pin15 Amps Flush type ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing modular switch 1 way 6A, 240 volts, 1 module ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing modular switch 1 way 16A, 240 volts, 1 module complete ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing modular fan step regulator, 2 module, 240 Volts, 50 Hz, suitable for ceiling fan of any sweep ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing modular socket, 6A, 240 volts, 3 pin combined 2 module, ISI marked flush type ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing modular socket, 6A/16A, 240 volts, 2/3 pin combined 2 module flush type ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65x50 mm three terminal ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing Lamp holder angular type, PVC/Polycarbonate type with back plate suitable for batten fittings ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing fan rod not less than 4' long including clamps, hooks, holdfasteners etc ; Complete all as Specified and as directed by Engineer-in-Charge.
Material and Labour for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, SPN 12 way, 240 volts grade with 200 Amps insulated rated bus bar, earth bar IP- 43 & IK-09, door earthing flush to wall, including testing suitable for fixing MCB SPN, SP etc, including taking down existing unserviceable one and removing from site ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing MCB of SP 5 to 32 Amps current carrying capacity, 240V, 10KA 'C' curve, ISI marked, fixed in the MCB DB complete conforming to IS/IEC-60898-1 2002 with connection testing and commissioning including taking down old unsv one from the site ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing MCB of SPN 32 Amps current carrying capacity, 240V, 10KA 'C' curve, ISI marked, fixed in the MCB DB complete conforming to IS/IEC-60898-1 2002 with connection testing and commissioning including taking down old unsv one from the site ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing MCB double pole,240 volts,40 to 63 Ampere , rupturing capacity 10 KA, 'C' cureve type ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, double sided connection, holder including LED tube light connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose, including taking down existing unserviceable one and removing from site ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing LED roadway luminaries 35 Watt, 230 V AC outdoor type with epoxy black powder coated sheet, high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket of suitable size with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete incl connecting wire with flexible PVC insulated copper cables from ceiling rose to fitting complete and testing, including taking down existing unsv one and removing from site ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size ; Complete all as Specified and as directed by Engineer-in-Charge.
Taking down carefully existing serviceable Ceiling fan/Wall mounted fan, ceiling cable end, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rod after rewiring including clamps, hooks, holdfasteners etc and connecting up, including making electric connection from ceiling rose or connector to fan ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and laying or fixing or passing through and including GI pipe, 1100 volts grade heavy duty stranded conductor cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated 16 sqmm 2 core nominal cross section in service connections ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and fix wall/ceing mounting LED 18 Watt PC Diffuser tube light fitting complet with all aceesories 1x18W LED suitable for domestic application 240Volts 50HZ including one tube rode and internally pre-wired with 1.5 sqmm twin twisted flexible copper conductor and ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of security light fitting LED 36 Watt aluminum pressure dia cast housing with touched glass cover IP-66 protection Including suitable size and accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal including taking down old CFL security light fitting ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing energy saving new generation 10 watt LED, 6000k bulk head luminaire with opal diffuser light fitting complete with all acessories and connection ; Complete all as Specified and as directed by Engineer-in-Charge.
Material and Labour for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 3 runs of 4 sqmm single core multistranded copper conductor PVC insulated cables as neutral continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly including taking down all sub main wiring ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and fixing sub main wiring with 2 runs of 4.0 sqmm single core, multi-stranded PVC insulated, FRLS unsheathed cable 1100 Volts grade with copper conductor drawn through and including concealed non metalic PVC conduit, medium grade, ISI marked, suitable size with conduit fittings and accessories concealed in wall/ceiling/floor including 1 run of 4.0 Sqmm multistranded PVC insulated FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly incl taking down old unsv one from site ; Complete all as Specified and as directed by Engineer-in-Charge. NOTE: Two runs of 4.0 sqmm copper cable and one run of 4.0 sqmm copper cable alongwith non metallic PVC conduit/conduit accessories will be measured as one unit length
Supply and Fixing GI bracket light grade GI Pipe 1.2 mtr Length for fixing of street light fitting 36/40 Watt including connection ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing Sheet matal enclosure for DB's (Double Door type) when MCB's to be used sinble pole and neutral, 4 way with 200 ampere rated bus bar,240 volts fixed sunk/flush to the wall with IP-43 AND IK-09 protection ; Complete all as Specified and as directed by Engineer-in-Charge.
Supply and Fixing exhaust fan 300 mm sweep including cutting of wall /window/lowers and fixing arrangement ; Complete all as Specified and as directed by Engineer-in-Charge.
Material and Labour for Earthing complete in replacement with galvanised iron mild steel earth plate electrode 60 cm x 60 cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth of not less than 1.5 m below normal ground level, connected to glavanised earth lead of GI wire of size 4mm dia by means of GI Bolts, Nuts, check nuts & washers and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 25mm dia from earth plate to Panel/DBs and water pipe 20mm dia GI medium grade from top of the earth electrode raised upto a level of 50cm above ground level, MS funnel with wire mesh embeded in earthing pit of size 30x30x30cm in PCC (1:3:6) type C-1 incl exposed surfaces smoth finished with 15mm thick cement mortar (1:6), RCC pre-cast (1:2:4 type B-1) cover slab of 40mm thick with 2 Nos. MS handles of 12mm dia suitable for carrying of pit cover, Angle iron frame made out of 40x40x4mm angle iron for 30x30mm PCC pit for holding the pit cover including providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/loose soil, returning, refilling and removing of surplus soil to a distance n. exc. 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 ; Complete all as Specified and as directed by Engineer-in-Charge. NOTE: (a) Cost of excavation, earth work, watering pipe, test point, MS Funnel with wire mesh and PCC pit with cover will be deemed to be included in the quoted rate. No extra cost shall be paid to the contractor against these items. (b) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor & no extra cost will be given to the contractor.
Sai Construction Co.
M/s. M Company
m/s. gopal krishan
B.J.CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .