Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.4 CrAccepted-AOC | ₹11.4 Cr | 1 | Accepted-AOC Being Lowest and Reasonable |
| 2 | 2₹13.0 CrRejected-AOC FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹13.0 Cr | 2 | Rejected-AOC Other than L1 |
| 3 | 3₹14.0 CrRejected-AOC 61 LAALA LAJPAT RAI COLONY BHOPAL M P 462023 | BHOPAL | MADHYA PRADESH | 462023 | ₹14.0 Cr | 3 | Rejected-AOC Other than L1 |
| 4 | 4₹14.1 CrRejected-AOC 15 16 GANGA COLONY KHATIPURA ROAD JAIPUR RAJ 302012 | JAIPUR | JAIPUR | RAJASTHAN | 302012 | ₹14.1 Cr | 4 | Rejected-AOC Other than L1 |
| 5 | 5₹15.0 CrRejected-AOC | ₹15.0 Cr | 5 | Rejected-AOC Other than L1 |
| Sl No | Description | Qty | Unit | BHARATSHAH CONSTRUCTION CO L4 | Horizon Construction L2 | Hariom Projects Pvt Ltd L11 | N. H. Saluji & Associates L10 | Sharda Infratech L9 | M/s L. K. Agarwal L5 | K R TRADERS L8 | MUKUL BUILDERS LLP L6 | SHREE KRISHNA INFRASTRUCTURE L3 | BBG INFRASTRUCTURE PRIVATE LIMITED L7 | M/s. Vasant Constructions L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCH 'A' PART-I TO XI: Note: These schedules are pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only | ||||||||||||||
| 2.00 | Total amount of Sch ‘A’ Part I (Building & Stuctures) | 1 | Lump Sum | 11,35,00,806 ₹11.4 Cr | 10,14,17,070 ₹10.1 Cr | 16,30,00,000 ₹16.3 Cr | 16,53,00,000 ₹16.5 Cr | 13,80,79,408.51 ₹13.8 Cr | 11,90,00,000 ₹11.9 Cr | 13,40,00,000 ₹13.4 Cr | 12,99,82,019 ₹13.0 Cr | 11,25,00,000 ₹11.3 Cr | 13,48,63,125 ₹13.5 Cr | 9,05,00,000 ₹9.1 Cr |
| 3.00 | Total amount of Sch ‘A’ Part II (Internal Water supply) | 1 | Lump Sum | 7,75,525.36 ₹7.8 L | 9,23,244.48 ₹9.2 L | 10,60,000 ₹10.6 L | 12,18,682.71 ₹12.2 L | 6,71,693.76 ₹6.7 L | 10,15,568.93 ₹10.2 L | 8,28,888 ₹8.3 L | 10,19,376 ₹10.2 L | 10,80,000 ₹10.8 L | 9,23,244.48 ₹9.2 L | 9,00,000 ₹9 L |
| 4.00 | Total amount of Sch ‘A’ Part III (Internal Electric Supply) | 1 | Lump Sum | 43,40,367.79 ₹43.4 L | 54,67,813.62 ₹54.7 L | 66,55,000 ₹66.5 L | 68,28,845.33 ₹68.3 L | 71,07,835.73 ₹71.1 L | 57,87,157.06 ₹57.9 L | 52,88,888 ₹52.9 L | 49,27,586 ₹49.3 L | 45,00,000 ₹45 L | 57,87,157.06 ₹57.9 L | 39,00,000 ₹39 L |
| 5.00 | Total amount of Sch 'A' Part-IV (Road, Path & Culverts) | 1 | Lump Sum | 17,99,516.61 ₹18.0 L | 18,82,716.1 ₹18.8 L | 24,65,000 ₹24.6 L | 25,92,160.83 ₹25.9 L | 22,08,674.45 ₹22.1 L | 21,42,281.68 ₹21.4 L | 16,88,888 ₹16.9 L | 24,19,275 ₹24.2 L | 17,10,000 ₹17.1 L | 21,42,281.68 ₹21.4 L | 16,20,000 ₹16.2 L |
| 6.00 | Total amount of Sch ‘A’ Part V (Area Drainage) | 1 | Lump Sum | 19,08,084.24 ₹19.1 L | 18,12,422.68 ₹18.1 L | 23,50,000 ₹23.5 L | 20,51,703.63 ₹20.5 L | 23,41,143.6 ₹23.4 L | 16,41,362.78 ₹16.4 L | 18,88,888 ₹18.9 L | 20,84,925 ₹20.8 L | 16,20,000 ₹16.2 L | 20,51,703.48 ₹20.5 L | 15,20,000 ₹15.2 L |
| 7.00 | Total amount of Sch ‘A’ Part VI (Sewage Disposal) | 1 | Lump Sum | 3,44,094.67 ₹3.4 L | 3,12,962.98 ₹3.1 L | 4,00,000 ₹4 L | 3,92,267.92 ₹3.9 L | 3,98,356.2 ₹4.0 L | 2,75,275.74 ₹2.8 L | 2,88,888 ₹2.9 L | 3,71,607 ₹3.7 L | 3,60,000 ₹3.6 L | 3,44,094.67 ₹3.4 L | 3,35,000 ₹3.4 L |
| 8.00 | Total amount of Sch 'A' Part-VII (Chain Link Fencing & Steel Gate) | 1 | Lump Sum | 3,45,334.67 ₹3.5 L | 3,39,824.55 ₹3.4 L | 4,30,000 ₹4.3 L | 4,49,306.4 ₹4.5 L | 4,47,268.38 ₹4.5 L | 3,34,194.84 ₹3.3 L | 3,28,888 ₹3.3 L | 3,82,494 ₹3.8 L | 3,07,000 ₹3.1 L | 3,71,327.6 ₹3.7 L | 3,10,000 ₹3.1 L |
| 9.00 | Total amount of Sch 'A' Part-VIII (External Water Supply) | 1 | Lump Sum | 10,70,073 ₹10.7 L | 8,72,584.8 ₹8.7 L | 9,85,000 ₹9.8 L | 17,03,556.22 ₹17.0 L | 12,92,584.44 ₹12.9 L | 12,84,087.6 ₹12.8 L | 7,88,888 ₹7.9 L | 11,23,800 ₹11.2 L | 9,90,000 ₹9.9 L | 8,56,058.4 ₹8.6 L | 8,35,000 ₹8.3 L |
| 10.00 | Total amount of Sch 'A' Part-IX (External Electric Supply) | 1 | Lump Sum | 28,76,976.03 ₹28.8 L | 40,77,513.77 ₹40.8 L | 28,50,000 ₹28.5 L | 34,72,212.45 ₹34.7 L | 33,12,193.3 ₹33.1 L | 32,24,197.27 ₹32.2 L | 21,88,888 ₹21.9 L | 32,06,335 ₹32.1 L | 25,20,000 ₹25.2 L | 24,80,151.75 ₹24.8 L | 21,50,000 ₹21.5 L |
Tender Value
₹14.6 Cr
EMD Value
₹10.6 L
Closing Date
24 Jun 2025, 6:00 pmClosed
Chief Engineer Pune Zone
HQ Chief Engineer Pune Zone, Pune - 411001
PROVISION OF 72 DUs ORs MD ACCN (G PLUS 2F) UNDER GE (CENTRAL) PUNE.
2025_MES_707717_1
84602
Open Tender
Civil Works
630 days
Pune
Class S and category a(i), and as per NIT
7 documents required · 7 mandatory
₹3,000
GE (Central) Pune
₹10.6 L
Yes
6 Aug 2025
10 May 2025
1 Jul 2025
10 May 2025
24 Jun 2025
16 Jun 2025
12 May 2025 - 19 May 2025
Amount
SCH 'A' PART-I TO XI: Note: These schedules are pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Total amount of Sch ‘A’ Part I (Building & Stuctures)
Total amount of Sch ‘A’ Part II (Internal Water supply)
Total amount of Sch ‘A’ Part III (Internal Electric Supply)
Total amount of Sch 'A' Part-IV (Road, Path & Culverts)
Total amount of Sch ‘A’ Part V (Area Drainage)
Total amount of Sch ‘A’ Part VI (Sewage Disposal)
Total amount of Sch 'A' Part-VII (Chain Link Fencing & Steel Gate)
Total amount of Sch 'A' Part-VIII (External Water Supply)
Total amount of Sch 'A' Part-IX (External Electric Supply)
Total amount of Sch 'A' Part-X (Rain Water Harvesting)
Total amount of Sch 'A' Part-XI (Site clearance, Excavation and Earthwork)
SCHEDULE 'A' PART-XII (MISC B/R AND E/M WORKS) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only.
S&F 200 mm dia perforated PVC pipe, in any length and in any position, complete all as specified and directed
S&F 250 mm dia perforated PVC pipe, in any length and in any position, complete all as specified and directed
S&F Pillar Cock with aerator 16 mm dia. Make- Cera- Victor F1 015101 or equivalent in makes as per Appendix 'C', complete all as specified and as directed. (Note: Flow of the fixture must be 3.0 litre per minute or less).
S&F Bib cock with wall flange and aerator 16 mm dia of Make - Cera-Victor- F1015151 or equivalent in makes as per Appendix 'C', complete all as specified and as directed. (Note: Flow of the fixture must be 3.0 litre per minute or less).
S&F Two way bib cock with side handle, wall flange and aerator 16 mm dia of Make - Cera - Titanium Model No F1003161 or equivalent in makes as per Appendix 'C', complete all as specified and as directed. (Note: Flow of the fixture must be 3.0 litre per minute or less).
S & F Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) of Make - Cera - F80301 04AB or equivalent in makes as per Appendix 'C', complete all as specified and as directed.
S&F Angular Stop Cock suitable for 15 mm bore of pipe (16 mm outer dia) with Wall Flange, chromium plated valves of Make - Cera -F8040204 or equivalent in makes as per Appendix 'C', complete all as specified and as directed.
S&F Overhead rain shower square, with Shower Arm 180 mm with wall · flange of Make: Cera - F7010501AB and Cera- F7040101 or equivalent in makes as per Appendix 'C', complete all as specified and as directed. (Note: Flow of the fixture must be 3.0 litre per minute or less).
S&F Wall mixer with bend pipe for overhead shower of Make: Cera- F1015401 or equivalent in makes as per Appendix 'C', complete all as specified and as directed. (Note: Flow of the fixture must be 3.0 litre per minute or less).
Supply, install, testing and commissIioning of Silent Diesel Engine Generating Set, 15 KVA (3-Ph), liqid cooled,powered with Engine developing BHP at 1500 RPM, coupled with 415 V, 50 Hz, 3 phase, 0.8 p. f, suitable alternator, 12V Battery with ARAI approved acoustic enclosure & compliance to CPCB-IV+ norms along with MCCB based AMF logic control panel & SMPS battery charger, tools and spares complete all as specified and directed and comprising of the following:-
(a) Engine : Diesel engine, 3 cylinder engine developing required BHP as per manufacturer specifications @ 1500 RPM at pune for prime rating of suitable for 15 KVA alternator and revised editions as applicable standard Totally enclosed, electric star,compression ignition,4 stroke. The engine shall consists of following specifications:- 1. radiator cooled engine 2. Dry type, replaceable paper element air cleaner with restriction indicator 3. Optimized turbocharger 4. lnline fuel pump with A1class mechanical governing 5. Spin on fuel filter 6. Full flow spin on lube oil filter 7. First fill of lube oil and coolant 8. Electrical starter motor with soft start engagement feature 9 Battery charging alternator 10. Suitable capacity of DC battery as per OEM recommendation
(b) Alternator : Alternator rated 15KVA, 0.8 PF, 415 V, 3 Phase ,4 Wire ,4 pole , 50HZ with standard desigh band of voltage regualtion +/- 1% from no load to full load and comprising of following specifications:- 1. Brushless type, Screen protected, Revolving field, Self-excited alternator conforming to IS/IEC 60034-1 2. Better motor starting capability 3. Compact design with sealed bearings for longer life and lesser maintenance 4. Impregnation on all wound components forbetter mechanical strength
(c) Acoustic enclosure: 1. Enclosure shall meet stringent MoEF/ CPCB norms of 75 dBA@1 mtr at 75% load under free field conditions. 2. The acoustic enclosure shall be made of CRCA sheets powder coated in Munsell green shade and a structural/sheet metal base frame painted in black. 3. 11 tank pretreatment process and UV resistant powder coating shall be provided to all parts to withstand extreme environment. 4. High quality noise absorbent and fire-retardant grade 5. Acoustic Insulation material (P.U Foam) shall be complying to IS 8183. 6. Top lifting for easy handling at customer site 7. Air inlet louvers specially designed to operate at rated load 8. Fluid drains for lube oil and fuel 9. External Fuel filling arrangement outside the enclosure
(d) Control panel : Control panel shall be powder coated for weather-proof and longlasting finish. The control panel shall consists of the following parts / controls/safety features:- 1. AMF Functionality 2. Engine Metering : Oil pressure, Engine temperature, Starting battery voltage, Engine running hours, AC Alternator Metering : L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency. kwh, Total & per phase (kw & kVA), PF, Utility Voltage and Freqency 3. Engine Protection : Low lube oil pressure, High/Low coolant temperature, Battery High/Low/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level 4. AC Alternator Protection : Over/Under Voltage, Over/Under Frequency, Loss of AC sensing. Overspeed, Over Current, kW Overload 5. Data Logging: Engine hours, Control hours and upto 5 recent fault codes 6. Configurable glow plug control 7. Sleep mode
(e) Power cables : Uninyvin copper conductor cables between Alternator & Control panel and inside the canopy shall be used.
(f) Exhaust Silencer : Critical Grade Silencer suitably optimized to meet stringent sound emission standards laid down by MoEF/CPCB Fuel System : Flexible Fuel Lines /SS fuel lines/Fuel Pressure Gauge Mounting Arrangement : Engine and alternator are mounted on a common MS fabricated base frame with AVM pads Skid mounted radiator. Base frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection and provision for cleaning.
S&F TV Coaxial Socket 1 module complete all as specified and as directed.
S&F CATV Co-axial Cables Electrolytic Grade solid annealed Copper conductor jelly field, aluminium foiled and aluminium wire braided complete all as specified and as directed.
S&F LED tube lights 4 feet fitting 1x 20W, 220V, aluminium housing body connecting up with and including flexible copper conductor cable of suitable size from ceiling rose to light fittings complete all as specified and as directed.
Supply and fixing LED light fitting 2 feet, 10 watt 220 V AC aluminium housing body including connecting up with and including flexible copper conductor cable of suitable size from ceiling rose to light fittings complete all as specified and as directed.
S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter,·voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm complete including cutting of wall if necessary to fit the fan all as specified and directed
Supply, laying, jointing & testing 100 mm dia Centnfugally cast Ductile Iron pipes class : K-9 with spigot and socket , suitable for Push on rubber joint, with internal cement mortar lining and external metallic coating with finishing layer of black bituminous coating, in any lengths, confirming to IS:8329-2000 including Rubber Gasket & joints laid in trenches/ road/ ducts/ footpath/ on wall/ on floor locations, complete all as specified and as directed.
Supply, laying, jointing Ductile Iron fittings including rubber joint or gaskets (as per fitting requirement) such as bends (any type, radius and angle), heavy duty for spigot & socketed or flanged pipes, tapers any type and radius and angle like straight, bend, increasing, decreasing or double socket etc., tee piece, single branch 'Y' junction or double branch, collar, caps and plugs etc. with internal cement mortar lining, and external zinc and black bitumen coated complete all as specified and directed.
M&L Fly ash brick masonry valve chamber of size 1.10m x 1.10m x 0.90m (internal dimension) with 15 cm thick foundation using PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) over 15cm thick hardcore, 23cm thick brick wall built in cement and sand mortar (1 :4), 10 mm thick internal and external plaster including top of floor in cement and sand mortar 1:3 finished even and smooth, without using extra cement, 6 mm thick MS sheet cover with, 50mm x 50mm x 6mm MS angle frame embeded in PCC 1 :2:4 type B-1 (using 20mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangements & handle made out of 25cm dia MS round bar, hold fasts etc and applying one coat of red oxide primer and two coats of synthetic enamel, paint to all steel surface including complete excavation, refilling and earth wotk in any type of soil and disposal of surplus soil to a distance n.exc 50m complete all as specified and as directed.
S&F Cl swing type Non Return valve flange end of floowing sizes confirming to IS 5312, PN 1.6 with lSI marked· complete with all necessary fittings such as nuts and bolts, washers, rubber gasket for both ends etc complete all as specified and directed
S&F Cl foot valve with Nytrile rubber ball inside complete flange end of following size confirming to IS 4038 lSI marked complete with all necessary fittings such as nuts and bolts, washers , rubber gasket etc complete all as specified and directed
Supply, installing, testing and commissioning factory made LT Panel board Indoor type suitable for 415 volts, 3 phase and neutral 50 HZ AC supply system having bus bar chamber with insulated aluminium busbar of rating 250 Amps -04 Nos (for RYBN) installed on resin/ porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made of 2.0 mm CRCA MS sheet and fixed with 40 x 40 x 6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coatsof red oxide primer, front & back side opening type, with apron for cable entry with single door shutter and locking arrangement (for Water Supply Pumps) including base with 1:2:4 PCC and making good and comprising of the following:-
S&F Pressure switch universal type 100mm to be mounted on 100mm pipe including its installation with necessary tools and drilling to pipe and all necessary connections and set to work complete all as specified and as directed.
S&F Pressure relief spring loaded safety valve of bronze 100 mm dia with all fittings, flanges complete all as specified and as directed.
S&F Rubber mat of 1 meter x 2 meter x 19 mm complete all as specified and directed
M&L DWC pipe of following dia with coupler at every 20 metre interval including laying and placing in positiion in trenches/ at locations as directed for protections of cables including levelling of the area before placing, complete all as specified and directed.
Supply, install, test and commission Step down transformer, OUTDOOR type, and conforming to latest IS 1180 (including ammendments) level 2, 11KV/433V, 50 Hz, delta/star connected, vector group DYN-11, copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating of capacity 250 KVA including bushings on HT & LT, cable box on HT & LT side. The Transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil IS 335 lSI marked filtered & dehydrated oil etc, and the permissible temperature rise shall not be exceed the limits of 40 deg/ 45 deg centigrade for Oil/ winding , complete all as specified and directed and comprising of the following accessories :-
(a) One cable box on primary HV side consisting of 3 Nos porcelain bushings with GM bushing rods complete with GM nuts, washers with cable glands suitable for incoming HT armoured cable. (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with cable glands suitable for reception of outgoing L T armoured cables including provision for connection of earthing to neutral. (c) Oil conservator tank with filter type, drain valve and oil level gauge. (d) Breather with first fill of dehydrating agent (silica gel). (e) Thermometer pocket on tank cover. (f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temperature reading pointer, max temp indicator and resetting with marshaling box. (g) Rating plate with terminal markings. (h) Two earthing terminals on tank/ tank cover to facilitate fixing of 32 x 6 mm Gl earth strip. (j) Oil Level gauge. (k) Oil drain and· filter valves.
Supply, installation, testing and commissioning of factory made, CPR! type tested, outdoor type double door compartmental type Trasformer Panel Board of suitable size, having front and back sides openable with hinged single doors and locking arrangement, IP 54 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of 50mmX50mmX6mm size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with and including PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour with necessary wiring , including fixing lugs, bolts, screws, CT & PT etc. including necessary earth work and excavation, return & refilling, removal, necesary ventilation projection with wire mesh to be provide and all as per manufacturer instruction comprising the following, complete all as specified and directed.
The MAIN LT PANEL shall also comprise of the following: Busbar Chamber: [i] 01 Set (3L + N) of aluminium busbar of rated capacity 630 A, covered with PVC insulated sleeves with colour code including insulator, nuts, bolts, etc, with complete connection. Incoming: [i] 400 A, 415 V, lcs =100% lcu 35/36 KA,four pole adjustable type microprocessor release 50 Hz, MCCB- 01 No [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, WNA, Wh/VAh, etc.- 01 No [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [iv] Digital Voltmeter- 01 No [v] Digital ammeter - 01 No Outgoing: [i] MCCB 200A Ics =100% lcu 4P 415V adjustable type thermal magnetic release with capacity 35/36 KA-02 Nos [ii] MCCB 160A lcs =100% lcu 4P 415V adjustable type thermal magnetic release with capacity 35/36 KA- 01 No [iii] MCB 63A 4P, 25 KA- 01 No
Supply, installation, testing and commissioning of factory made, CPRI type tested, outdoor type double door compartmental type Building LT Panel of suitable size, having front and back sides openable with hinged single doors and locking arrangement, IP 54 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of 50mmX50mmX6mm size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with and including PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour with necessary wiring , including fixing lugs, bolts, screws, CT & PT etc. including necessary earth work and excavation, return & refilling, removal, necesary ventilation projection with wire mesh to be provide and all as per manufacturer instruction comprising the following, complete all as specified and directed.
The MAIN LT PANEL shall also comprise of the following: Busbar Chamber: [i] 01 Set (3L + N) of aluminium busbar of rated capacity 300 A, covered with PVC insulated sleeves with colour code including insulator, nuts, bolts, etc, with complete connection. Incoming: [i] MCCB 200 A, 415 V, lcs =100% lcu 35/36 KA, four pole adjustable type thermal magnetic release 50 Hz- 01 No [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, WNA, Wh/VAh, etc.- 01 No [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [iv] Digital Voltmeter- 01 No [v] Digital ammeter - 01 No Outgoing: [i] MCCB 100A Ics =100% lcu 4P 415V adjustable type thermal magnetic release with capacity 35/36 KA-04 Nos (One spare) [ii] MCB 32A 2P, 10 KA C curve 230 V- 03 Nos
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor type double door compartmental type Building LT Panel of suitable size, having front and back sides openable with hinged single doors and locking arrangement, IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of 50mmX50mmX6mm size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with and including PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour with necessary wiring , including fixing lugs, bolts, screws, CT & PT etc. including necessary earth work and excavation, return & refilling, removal, necesary ventilation projection with wire mesh to be provide and all as per manufacturer instruction comprising the following, complete all as specified and directed.
The MAIN LT PANEL shall also comprise of the following: Busbar Chamber: [i] 01 Set (3L + N) of aluminium busbar of rated capacity 200 A, covered with PVC insulated sleeves with colour code including insulator, nuts, bolts, etc, with complete connection. Incoming: [i] MCCB 80 A, 415 V, lcs =100% lcu 16 KA, four pole with adjustable thermal magnetic release 50 Hz- 01 No [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, WNA, Wh/VAh, etc.- 01 No [iii] Digital Voltmeter- 01 No [iv] Digital ammeter - 01 No Outgoing: [i] Compartment feasable for 13 Nos Meters with prewired connection. [ii] MCB 32A 2P, C Curve10 KA 230 V- 13 Nos
Supply and fixing of Security/ Street light control panel outdoor type made out of 3.15 mm thick CRCA sheet totally enclosed conforming to relevant IS/IEC, CPRI type tested and suitable bus bar including angle iron frame made out of 40x40x 5 mm angle duly powder coated duly grouted with PCC including earthwork if any like excavation, returning and refilling, complete all as specified and as directed comprising the following :- (a) MCCB TPN 63 Amps, 415 Volts, AC, 50 Hz, 10 KA rupturing capacity as incoming- 01 No (b) MCB TPN 40 Amps, 415 Volts, AC, 50 Hz, 10 KA rupturing capacity as outgoing - 02 Nos (c) Power contactor 3 Pole, AC, 3 rating, 40 Amps coil voltage 240 Volts- 02 Nos (d) Digital timer for controlling the contactor, single phase, 230 Volts AC - 01 No (e) MCB SP 06 Amps, 230 Volts, AC, 50 Hz - 03 Nos (f) Switch socket combination multipurpose 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete - 01 No (g) Indicator lamps (RYB) - 01 Set (h) Digital multi functional multi meter for showing Volts/ Amps/PF etc alongwith suitable rating CT coil - 01 Set (j) Control wiring for automatic operation of street lights with by pass arrangement all as specified and as directed. (k) Incoming and outgoing terminals for suitable cable
Supply and Fixing all in one smart integrated solar street light 40 watt with built in Mono Crystalline Solar PV Module Panel, Lithium Ferro phosphate battery, MPPT charge controller, PIP sensor, light having colour temp 6000-6500K, Lumens 4800, 2 days autonomy with dimming profile, including supply and erection of standard tubular pole of 6 m height having base plate of dimensions min 200 x 200 x 12mm, bolt size 4 Nos x 20 mm dia all including necessary brackets, excavation, earthwork, foundation, PCC and foundation bolts (Hold fasts) as per manufacture's design and specifications complete all as specified and as directed.
Supply, installation, testing and commissioning of L T Automatic Power Factor Correction (APFC) Panel outdoor factory made weather, dust and vermin proof IP 54 made up of 3.15mm thick CRCA sheet duly powder coated with metallised poly propylene (MPP} type capacitors bank 125KVAR capacity heavy duty with variable corrections comprising of different stepping (1 X50KVAR, 2 X 25 KVAR, 2X10 KVAR, 1 X 5 KVAR). The panel shall have copper bus bar suitable size 3 phase and neutral (300A bearing capacity each) and comprising of the following:-
(a) MCCB FP 160 Amps microprocessor release 35/36KA -01 No. (b) Heavy duty contactors suitable for frequent operation having current limiting resistors suitable for capacitive switching of variable KVAR correction of superior specifications for (1 X50KVAR, 2 X 25 KVAR, 2X10 KVAR, 1 X 5 KVAR) (c) MCCB/MCBs 'C' curve for backup protection off capacity as required for (1 X50KVAR, 2 X 25 KVAR, 2X10 KVAR, 1 X 5 KVAR) (d) Microprocessor based intelligent APFC relay for controlling variable connection KVAR. (e) Indicating lamp (RYB) LED type with toggle switch-3 sets (f) MPP type of capacity (1 X50KVAR, 2 X 25 KVAR, 2X10 KVAR, 1 X 5 KVAR) heavy duty capacitor bank consisting of suitable no of switching sequence, 3 phase, 415 volts suitable for 10% over voltage & 30% overcurrent having losses less than 0.5 W/KVAR with discharge resistors (g) Suitable Nos & rating of contactors as required. (h) Internal wiring of panel with standard copper cable of suitable size. (j) The design of panel shall be got approved from GE before fabrication. (k) Provision for connection of earth countinuity conductor.
Earth work in excavation upto 1.5 m depth in any kind of soil by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sq.M on plan) including getting out, complete all as specified and as directed
Earth work in excavation exc 1.5 m but not exc 3.0 m in depth in any kind of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sq.M on plan) including getting out, complete as specified and as directed.
Earth work in excavation in any kind of soil by mechanical means (Hydraulic excavator) in foundation trenches or for shafts, walls, cesspits, manholes, pier holes, laying pipes or underground cables or foundation of poles / stay assembly, not exceeding 1.5 m in width or 10 Sq.M on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil, complete all as specified.
Earth work in excavation in ordinary rock by mechanical means (Hydraulic excavator) in foundations trenches or for shafts, walls, cesspits, manholes, pier holes, laying pipes or underground cables or foundation of poles / stay assembly, in road cutting /RCC or PCC floor/sub base etc., not exceeding 1.5 m in width and not exceeding 10 Sq.M on plan and not exceeding 1.5 m in depth, including getting out the excavated rock complete all as specified and as directed.
Earth work in excavation in ordinary rock by mechanical means (Hydraulic excavator) in foundations trenches or for shafts, walls, cesspits, manholes, pier holes, laying pipes or underground cables or foundation of poles / stay assembly, in road cutting /RCC or PCC floor/sub base etc., not exceeding 1.5 m in width and not exceeding 10 Sq.M on plan but exceeding 1.50 m but not exceeding 3.0 m in depth, including getting out the excavated rock complete all as specified and as directed.
M&L Double Wall corrugated 150mm dia class SN8 HDPE pipe including necesary rings/socket/fittings, Laid and Jointed confirming to IS-16098 complete all as specified and as directed.
M&L Double Wall corrugated 200mm dia class SN8 HDPE pipe including necesary rings/socket/fittings, Laid and Jointed confirming to IS-16098 complete all as specified and as directed.
Horizon Construction (BID ID -3332781)
SHREE KRISHNA INFRASTRUCTURE (BID ID -3335442)
BHARATSHAH CONSTRUCTION CO (BID ID -3331789)
M/s L. K. Agarwal (BID ID -3334128)
MUKUL BUILDERS LLP (BID ID -3334033)
BBG INFRASTRUCTURE PRIVATE LIMITED (BID ID -3331990)
K R TRADERS (BID ID -3334184)
Sharda Infratech (BID ID -3333548)
N. H. Saluji & Associates (BID ID -3333261)
Hariom Projects Pvt Ltd (BID ID -3333239)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid