Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.2 LAccepted-AOC | 1 | Accepted-AOC ACCEPTED BY COMPETANT AUTHORITY | |
| 2 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹2.4 L
EMD Value
₹4,781
Closing Date
12 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(E), BSNL, ED Kota
BSNL,Electrical Division, E-10B Exchange campus, Road no-2, IPIA, Kota
Repairing of EI and Fans, shifting, ITC of AC and miscellaneous work in SSA Jhalawar.
2020_BSNL_59020_1
18/20-21/BSNL/ED /KOTA
Open Tender
Electrical Works
Item Rate
30 days
jhalawar
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
AO (Cash), O/o GMTD BSNL, KOTA
₹4,781
24 Nov 2020
3 Oct 2020
14 Oct 2020
3 Oct 2020
12 Oct 2020
3 Oct 2020
90 days
Amount
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm
3 x 1.5 sq. mm
4 x 1.5 sq. mm
5 x 1.5 sq. mm
S/F of 4 module polycarbonate modular surface boxes with suitable size phenolic laminated sheet cover in front i/c one no 6A Celiling rose i/c fixing the same on wall /ceiling etc as reqd.
S/F of following type HRC fuses in existing MV panel i/c removing of exsiting faulty unit etc as reqs.
125A Din type fuse link HN type
63 A cylinderical fuse link HF type
S/F of following size Ceiling fan suitable for operation on 230 Volts ,single phase 50 Hz AC supply complete etc as reqd (without regulator)Make -( Bajaj/Polar /USHA /crompton /havells /orient )
S/F of D type fan hook made of 08 mm (NS)dia MS rod i/c fixing the same on ceiling with 2 pcs.of heavy duty Fasteners (M10x75mm) etc as required.
Supplying and fixing extra down rod of 20 cm length G.I. pipe,15mm dia, heavy gauge including painting etc. as required. (Note:More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying and fixing one module Modular type stepped type electronic fan regulator on the existing modular plate switch box including connections etc. as required.(make Anchor or SS)
S/F of two module Stepped type electronic fan regulator in existing board I/c dismantling of existing faulty regular (if required ) and connection, testing etc. as reqd ( Make -Anchor /havells )
S/F of 19mm dia GI flexible electrical conduit pipe with gland i/c fixing on wall /ceiling /cable tray with metalic shaddle with screw etc as reqd
Making square opening in brick/stone wall for exhaust fan up to 450mm sweep i/c cutting of wall for making suitable size hole ,packing the extra space ,plaster finishing i/c cleaning the space after execution of Work etc as reqd
SITC of 450mm sweep heavy duty exhaust fan with metallic louvers shutter 1400 RPM suitable for work on 230 V Single phase AC Supply ,i/c fixing the same wall surface /grill with suitable clamp i/c connection etc as reqd (Make -Almonard/crompton/Bajaj/USHA).
SITC of 300 sweep metallic exhaust fan with metallic blade ,protective guard ,suitable for work on 230 V Single phase AC Supply ,i/c fixing the same wall surface /grill with suitable clamp i/c connection etc as reqd (Make -Almonard/crompton/Bajaj/USHA).
S/F of 450 mm sweep heavy duty mark II oscillating type Padestal fan with 3 speed control regulator having powder coated guard and aluminium die cast blade ,1440 RPM speed suitable for working on 230 V 50 Hz single phase AC supply & i/c connection etc. complete as required (Almonard /Crompton/Bajaja or SS )
SITC of 1x18/20 Watt LED Box type luminare with CRCA Housing having efficency 100 lumes /watt complete with T-8 LED tube rod in polycarbonate housing , suitable for work on 230 volt 50Hz AC supply i/c connection testing etc complete as required.(Make -Philips /crompton/Havells /Bajaj/Wipro/Surya ).
SITC of 45 Watt Energy Efficient LED type Road Light luminare with pressure die cast aluminum with mid power LED's as light sources & Heat Resistant toughended glass with frame cover and integral electronic driver complete with IP 66 protection ,min.system efficacy 100 lm/Watt., THD<10%, PF>0.95 suitable for work on 140-270 V AC Supply i/c ixing on existing GI bracket / Pole with suitable modificaion of braket (if reqd) and connection with 3 Core 1.5 sqmm PVC insulated PVC Sheathed copper conductor cable from fitting to MCB in MS box through GI Bracket / Pole etc. as reqd. The fixture shall have a corelated color temperature of at least 5000K and a CRI of > 70. The Light system shall be designed for system life 50000 hour i/c removing of existing faulty light etc as reqd . (Make -Philips /crompton/Havells /Bajaj/Wipro )
Supplying of following size of pvc insulated pvc sheathed 1.1 kv grade Aluminium conductor armoured cable confirming to relevant IS-Specification etc complete as reqd. (Make -Polycab/havells/finolex).
2 x 6 Sqmm.
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade of following size on surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
S/F of 20 mm wide PVC cassing capping on wall /roof wit suitalbe screw etc as reqd.
Refilling of exisitng CO2 type 4.5 Kg Capacity Fire Extinguishers of following capacity with CO2 up to desired specified pressure i/c transportation of empty the cylinder to & fro , cleaning, refilling the gas and testing etc. complete as reqd. ( Note - Work shall be carried out only by specialized agency and necessary test certificate for each refilled cylinder is to be submitted).
Refilling of exisitng CO2 type 22.5 Kg Capacity Fire Extinguishers of following capacity with CO2 up to desired specified pressure i/c transportation of empty the cylinder to & fro , cleaning, refilling the gas and testing etc. complete as reqd. ( Note - Work shall be carried out only by specialized agency and necessary test certificate for each refilled cylinder is to be submitted).
S/F of One meter hose pipe with horn for 4.5 kg Co2 type fire extingusher i/c fixing and testing etc as reqd.
S/F of single phase SMC plastic moulded weather proof ,shocked proof ,maitenance free fire retardant meter box of size 250mmx200mm x100mm with viewing window suitable for wall mountung and cable entry from bottom side with side hinges door I/c fixing on wall with suitable fastner i/c connection testing etc as reqd (Make SINTEX or SS).
Dismantling of the existing split /window type AC Unit complete with indoor unit,outdoor unit stand, refrigerant piping,drain pipe,shifting the dismaltled items to a safe place in exchange premises and handing over to the incharge,packing of SPAC wall hole ,making good the damage etc as reqd (Note- Existing refrigerent from working Split AC to be stored in compressor before dismentling for further use at new location).
Transportation of Split /Window AC units with all acessories like indoor ,outdoor unit ,copper pipe ,drain pipe ,partical board as dismentalled from TE Jhalawar to various TE /BTS sites in SSA up to 50 KM i/c. loading,unloading etc. as reqd.
Installation, Testing & Commissioning of the 1.5 TR inverter type Split type AC unit at a specified location as per direction of Engg-In-charge by mounting/fitting Indoor and Outdoor units , making opening in wall, laying and fixing of both liquid and hot gas lines , inter connecting wiring for both indoor outdoor units up to 5 mtrs length and ,interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle , Leak testing entire system ,vacuemising the system ,charging of Refrigerant gas in the unit ,making power supply connections from the power point,and making good the damages etc.as required.
Pdg and Fixing additional 1/4"&5/8" size or size same as supplied by Split AC manufacturer refrigerant copper piping with 3x2.5 sq.mm. PVC Insulated PVC Sheathed copper cable i/c covering of Copper Pipe with polystyrene insulation i/c cutting ,brazing ,jointing,bends, sockets etc as reqd. ( Note- Combined Length shall be measured )
Provision of Top up of R-22/R-32 /410 gas in existing Window A.C /Split A.C units, i/c flushing, testing etc. as required.
S/F of 50 mm dia 2 mm thick PVC pipe on wall / surface for protection of refrigerant pipe of split AC units etc.i/c elbo /bend /socket etc as complete as reqd.
Supplying and fixing of following size of flexible copper cable on surface/ recess, suitable for work on 230 volt, 50 HZ AC supply i/c connection etc as reqd (Make -Polycab/Havells /finolex).
3x2.5 sq mm
3x1.5 sq mm
Closing of existing window in AC plant room to prevent AC leakage by brick masnoary i/c plastering , finishing etc complete as reqd as reqd.
General Servicing of 1.5 /2.0 TR WAC/SAC units at site of different make I/c removing from existing position if reqd., dismantling of faulty parts, cleaning the air filter, cleaning the condenser and evaporator coil with help of caustic soda soap solution, lubrication of moving parts, complete checking, testing and minor faults rectification i/c replacement of knobs/ wiring kit (if required), setting of thermostat, preparing report including tightness of all electrical connections from SP MCB in DB to DP MCB/Plug & socket to TDR to AC unit etc as reqd.
Charging of Refrigerant gas R-22 up to specified pressure(as per manufacturer's recommendation) in following capacity AC units and pressure testing by nitrogen, vaccumisation for 2 hours, purging with gas and testing commissioning of the AC unit etc. as reqd. Note: One job consists of charging of Gas in one compressor i.e.. One complete air conditioning circuit only.
1.5 TR WAC/ Split AC
S/F of 75 mm dia PVC green suction pipe with PVC sprial ribbed on wall / surface for protection of refrigerant pipe of split AC units i/c fixing with suitable MS shaddle etc.as te reqd.
Shifting of Existing all type light fitting /Fire detector from wall /ceiling /false ceiling / AC duct Boxing dismentling from one location with all acesssories i/c ITC on ceiling/wall/flase ceiling i/c connection i/c cleaning of the light fitting as per direction of Engineering -In-charge etc as reqd.
Dismantling the existing MDF partical board return air Boxing of all size & shape from AC plant to corridor -BB room -Transmission room complete by unscrewing , opening the MDF partical board , angle iron supports, then lowering down the same from first floor to ground floor i/c shifting the same to the place inside the exchange premises as directed by Eng.-in-charge.etc as reqd.
Dismantling the existing old GI ducts /plenum of all size & shape of from package plant to all rooms along with damper ,S/A , R/A Grill complete by unscrewing, opening the flanges, supports,hangers, lowering down the same from first floor to ground floor i/c shifting the same to the place inside the exchange premises as directed by Eng.-in-charge.
Pdg. Making opening in stone /brick wall for fresh air i/c cutting of wall for making suitable size opening, packing the extra space ,plaster finishing i/c cleaning the space after execution of Work etc as reqd.
Fixing of existing spare MDF partical board for closeing of existing opening in false ceiling /WAC opening /other opening i/c cutting and fixing with suitable screw as per site requirement etc as reqd.
Dismentling of existing aluminum partation ,doors, fixed glass panes i/c remoing of vertical members fixed in floor with rawal plug and shifting and stacking of sericable material in the same building same floor within 50 meter lead as directed by Engineering-in-charge.
S/F of following MS items to be used for for frame work /Exhaust fan grill I/c Cutting , welding painting etc. as required.
35mm X 35mm X 5mm Angle iron
25mm X 25mm X 3mm Angle iron
1"x1" square MS wire mesh of 18 SWG wire
20 SWG MS Sheet
20x3 mm MS flat
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .