Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.5 L+₹3.4 L (10.2%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L2 | Rejected-AOC L2 | |
| 3 | L3₹51.5 L+₹18.4 L (55.5%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹46.2 L+₹13.1 L (39.5%)Rejected-AOC 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L4 | Rejected-AOC L4 | |
| 5 | Rejected-Technical RZ 40 PALAM VIHAR DWARKA SECTOR 6 NEW DELHI 75 | NEW DELHI | DELHI | 75 | - | Rejected-Technical Due to not enlisted in reqd category |
Tender Value
₹47.8 L
EMD Value
₹95,600
Closing Date
18 Mar 2020, 6:00 pmClosed
CWE (AF) Tughlakabad
HQ CWE (AF) Tughlakabad
REPAIRS / MAINT OF TRANSFORMER HT/LT CABLE AND BASIC E/M WKS AT TECH AREA AND VAYUSENA VIHAR UNDER GE (AF) TUGHLAKABAD
2020_MES_321238_2
CWE/TKD/TOKEN-21/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Tughlakabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Tughlakabad
₹95,600
Yes
27 May 2020
3 Mar 2020
20 Mar 2020
3 Mar 2020
18 Mar 2020
6 Mar 2020
Amount
Dehydration and filtration of the existing transformer/servo voltage stablizer oil by Dehydration plant to achieve di-electric strength of 40 KV at the gap of 4mm complete all as specified and directed by Engineer-in-charge. Notes:- Dehydration plant shall be brought at site by the contractor and shall also include the following provisions a) Testing of transformer /servo voltage stablizer oil before & after dehydration shall be carried out as directed. b) The Unit of payment under this item shall be per liter of oil meant for all processes to the entire completion of jobs. (c) Contractor will maintain a register of dehydration and filtration of each and every eqpt as per format given by Engr-in-charge and submit the same to Engr-in-charge.
Supply and filling transformer oil for topping up or replacement in different existing transformers outdoor/indoors type of any capacity located and installed at different places and different height complete all as specified and as directed by the Engineer-In-Charge. Make Power oil Note: - The entire quantity of transformer oil shall be procured in one go. The complete material shall be brought at site and then as per requirement oil should be shifted to site. The Purchase Vrs of transfer oil will be verified by AGE personally and certificate for the supply of genuine transformer oil shall be kept on record. Cost of this aspect deemed to be included in the quoted rate
Supply and replacement of dehydrating agents (Silca gel) in transformers of capacity upto 1000KVA transformer outdoor/indoor type complete all as specified and as directed by the Engineer-In-Charge.
M&L for disconnecting/removing of HT/LT cable and earth connections of aluminum/copper wound, 11KV/433 volts, 415/380 volt and 415/220volts of capacity 60-1000 KVA, outdoor/indoor type transformer of any make , draining out of the transformer oil in empty barrels provided by the department and transporting in a store provided by the department at a distance not exceeding 2KM , transporting the unserviceable transformer to a civil workshop approved by Engineer- in- charge (T& P and crane/vehicle to be arranged by the contractor) , opening of the transformer in workshop, , taking out core and coil assembly including HT/LT coil complete, removing tape, paper insulation strips etc gently & carefully, washing/cleaning of the dust, rust and dirt from all metal parts inner/outer surface of transformer including cooling tube, rewinding of LT coil with existing size of copper coil duly insulated with suitable insulation material and re-assembling after suitable repair/replacement of parts transporting back to sub station, installation ,testing and commissioning at site complete all as specified and as directed by the Engineer-In-Charge. Note:- (a) Labour for repair/new parts shall be included in the quoted rates by the contractor except transformer oil, rewinding of LT/HT coil will be paid separately under respective items. and taking out of the following old defective part from existing transformer of capacity 60 KVA to 1000 KVA of any make (for the transformer mentioned under items No 4 here-in-above) and in lieu providing new parts in the above tansformer complete all as specified and as directed by the Engr-in-charge for the followings.
Replacement of LT leg coil in copper winding with insulation varnishing and baking coil assembly
Replacement of HT leg coil in copper winding with insulation varnishing and baking coil assembly NOTE:for srl item No-04- (i) Transformer will be repaired from approved manufacturer. (ii) Transformer will be repair after prior approval of CWE (AF) TKD.
Supply and replacement of LT bushing (Brass stud and bolts with porcelian insulator) suitable size to fixed the transformer capacity range 60 to 400 KVA including replacement of gasket , cable glands, etc to make the transformer leak proof complete all as specified and as directed by Engr-in-charge
All as per item ser No 5 here-in-before but suitable for 500 KVA to 1000 KVA transformer
Supply only ceramic bushing and Gasket on LT side of transformer of following capacities (Make : Mysore Potteries/BHEL :-
60 KVA to 400 KVA
500 to 1000 KVA
All as per item No 7 here-in-before, but on HT side of transformer of following capacites :-
60 KVA to 400 KVA
500 to 1000 KVA
M&L for Painting of transformer after cleaning the body surface of transformer by rubbing with emery Paper to remove oil stains, dust etc and applying two coat of snthetic enamel paint by spray painting including preparation of surfaces capacity of transformer of following capacity complete all as specified and as directed by Engr-in-Charge
60 KVA to 400 KVA
500 to 1000 KVA
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified and as directed by the Engineer-In-Charge
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by the Engineer-In-Charge.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed by the Engineer-In-Charge.
M&L for sand cushioning (dry sand) to underground cable for cable protection laid in trenches / in existing cable ducts complete all as specified and as directed by the Engineer-In-Charge. Note: For payment point of view, compacted thickness of sand shall be measured.
Supply & laying in reinforcement PCC cable covers, class-HV type-I, flat, size 300x180x40mm complete all as specified and as directed by the Engineer-In-Charge.
M&L for brick laying with subclass 'B' bricks well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified and as directed by the Engineer-In-Charge
M&L in replacement of cable XLPE insulated screened PVC bedded, galvanized steel wire armored, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of sizes 240 sqmm 3 core complete all as specified and directed by the Engineer-in-Charge.
M&L in replacement of cable XLPE insulated screened PVC bedded, galvanized steel wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of the following sizes complete all as specified and directed by the Engineer-in-Charge
185 sqmm 3.5 core
240 sqmm 3.5 core
120 sqmm 3.5 core
Supply & fixing cable jointing kit and testing complete for 11 kv grade cable for Indoor termination hot shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq mm to 185 sqmm complete all as specified and directed. . Make 3M/Denson/Raychem
All as per item No 18 but of size 240 sqmm to 300 sqmm
All as per item No 18 here-in-before but of size 50 sqmm to 95 sqmm
S & F, testing and commissioning heat shrinkable straight through Jointing Kit suitable for LT Cable of size 25 sq mm to 50 sq mm , 3.5 core, Make- Denson/Reychom/M seal
S & Fixing testing and commissioning heat shrinkable straight through Jointing Kit suitable for LT Cable of size 70 sq mm to 150 sq mm , 3.5 core, Make- Denson/Reychom/M Seal
S & Fixing testing and commissioning heat shrinkable straight through Jointing Kit suitable for LT Cable of size 150 sq mm to 300 sq mm , 3.5 core, Make- Denson/Reychom/M Seal
M&L for cutting of Hardstanding/road by mannual method upto150mm deep for inserting GI pipe for cable protection complete including ready mix concreate and making good distrubed surface complete all as specified and as directed by Engr-in-Charge.
M & L for galvanised pipe of dia 100 mm, 'light grade' with all fitting,laid in trenches for passing of cable etc. complete all as specified and directed by Engr-in-charge.Make:- Jindal/BST/TATA
M & L for replacement of potential transformer (voltage transformer) 11 KV/ 110 V, dry type , complete with winding, indoor resin cast & ration 11 KV/rt3/110/rt3/class 0.5-3,burden 50 VA-50 VA including conecting and testing complete all as specified and directed by Engg - in - Charge.
Supply and installation, testing & commissioning with HT panel phase indoor resin cast CT of ranging 15 Amp to 150 Amp/5-5A as per each feeder requiredclass 1.0/5P10, burden 15 VA-15VA including conecting and testing complete all as specified and directed by Engg- in- charge.
M & L for supply, installation and testing for Earthing complete with galvanised steel earth plate electrode 60×60Cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to but using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 shown in SSR Part-I connected to earthing test point complete all as specified or indicated including testing on completion complete all as specified and directed by Engr-in-charge.
S&F in replacement Energy saving 150 Watt envoirmental friendly, long life, exclusive innovative die cast aluminium IP-65 flood light in LT pole with high power LEDs as light source, suitable for heighlighting architectural features complete with all electrical accessories all as specified by EIC Make: C&S Cat Part No LTE F150WHPLED or equivalent in Bajaj/Phillips/Havells
M & L for excavation by trenchless boaring technology for holes under road pavement, hardstanding using ultra sound technique and engaging necessary machine including HDPE pipe ISI marked of dia 100 mm suitable for .4 Mpa working pressure complete all as specified and directed by Eng-in-charge. Note: HDPE pipe and marking good the disturbed surface shall deemed to be included in rate quoted by contractor.
Dismantling and taking out old UNSV pole any type,and M & L for steel tubular pole swaged type 410 SP-55 (11.0 metres long) complete with CI base and finial including necessary excavation, earth work, PCC and coping and painting to new pole with one coat of red oxide primer and two coat synthetic enamel paint silver colour complete all as specified and directed by Engr-in-charge.Note - Excavation, PCC work 1:2:4 type B-1 using 20 mm graded stone aggregate, erection of pole and coping is deemed to be included in quoted rate by the contractor). Make of pole- Bansal pole/Kolkata pole/Kanpur pole or eqvt
S&F in replacement PVC looping boxes of size 300 x200x150 mm, factory made, consisting of 2.00 mm thick PVC sheet and aluminium bus bar 3 phase, 4 wire system of capacity 200 Amp, and proper locking arrangement and opening for incoming and outgoing cable complete all as specified and directed by Engg-in-charge. Make:- Syntex
S&F in replacement, LED street light fitting of capacity 60 watt, cool white, complete with drivers and all accessories & making all necessary connection complete all as specified and directed Make- Cat part no : LHETBXU7PA6J060 or equivalent in Surya/Bajaj/Halonix/Havells
Supply and fixing PVC insulated and sheathed circular flexible copper conductor 1100 volts, of size 6 sqmm 4 core conforming to ISI mark. Make Kalinga/Havells/Finolex
Taking out old u/s contactor from existing AMF panel and S & F 3 pole power contactor 3 pole with AC coil MNX 630 A, AC-3 duty rating at 415 V, 50 HZ 375 KW ,Ith amp 1000 type CH7 630 T. Make : havells/Seimens/ L & T
Flint India
Parveen Builders
Neeraj Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .